• Title/Summary/Keyword: Chest Radiography

Search Result 369, Processing Time 0.026 seconds

Optimal Exposure Conditions according to Detector Type in Chest Digital Radiography (디지털흉부X선촬영에서 검출기 방식에 따른 최적의 노출조건)

  • Lee, Won-Jeong
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.213-221
    • /
    • 2015
  • The aim of this study was to set up the optimal exposure condition according to detector type considering image quality (IQ) with radiation dose in chest digital radiography. We used three detector type such as flat-panel detector (FP) and computed radiography (CR), and charge-coupled device (CCD). Entrance surface dose (ESD) was measured at each exposure condition combined tube voltage with tube current using dosimeter, after attaching on human phantom, it was repeated 3 times. Phantom images were evaluated independently by three chest radiologists after blinding image informations. Standard exposure condition using each institution was 117 kVp-AEC at FP and 117 kVp-8 mAs at CR, and 117 kVp-8 mAs at CCD. Statistical analysis was performed by One way ANOVA (Dunnett T3 test) using SPSS ver. 19.0. In FP, IQ scores were not significant difference between 102 kVp-4 mAs and 117 kVp-AEC (28.4 vs. 31.1, p=1.000), even though ESD was decreased up to 50% ($62.3{\mu}Gy$ vs. $125.1{\mu}Gy$). In CR, ESD was greatly decreased from 117 kVp-8 mAs to 90 kVp-8 mAs without significant difference of IQ score (p=1.000, 24.6 vs. 19.5). In CCD, IQ score of 117 kVp-8 mAs was similar with 109 kVp-8 mAs (29.6 vs. 29.0), with decreasing from $320.8{\mu}Gy$ to $284.7{\mu}Gy$ (about 11%). We conclude that optimal x-ray exposure condition for chest digital radiography is 102 kVp-4 mAs in FP and 90 kVp-8 mAs in CR, and 109 kVp-8 mAs in CCD.

The Distribution and Patient Care in Radiography for Emergency Outpatients (응급환자의 방사선영상검사 분포 및 Patient Care)

  • Lee, Hwan-Hyung;Kang, Won-Han
    • Journal of radiological science and technology
    • /
    • v.19 no.1
    • /
    • pp.55-74
    • /
    • 1996
  • This study was carried out to improve service efficiency and to cope with a emergency situation in emergency radiography, through analysis of the radiographic distribution and literature cited about emergency care. Data collection of radiographic distribution was surveyed for 761 emergency outpatients who visit during JAN, 1994 at ER of the general hospital in Pusan city. The results is as follows: Emergency radiography rate of simple radiography was 61.1 %, special radiography 2.5 %, CT 12.6 %, and ultrasonography 6.7 %. In simple radiography rate, a high rate was distributed on male(63.6 %), thoracicsurgery part(90.0%), admission patient(74.9 %), and long stayed patient at ER. In special raiography rate, a high rate was observed in urologic part(28.6%), and in CT rate, observed neurosurgery part(49.2 %) and neurologic part(36.7%). Ultrasonography rate was high for female(8.8 %) and internal medicine part(15.9 %). There are distributed regional radiography rate in radiographic type that chest(55.3 %) is high in the simple radiography, urinary system(1.2%) in the special study, and brain(40.0 %) in the CT. Regional radiography rate according to diagnostic department also was showed highly for head(64.6%) in neurosurgery, chest(90.0%) in thoracic-surgery, abdomen(58.0%) in general-surgery, spine (40.0% ) in neuro-surgery, and pelvis(15.9%), upper extrimity(20.5%), and lower extrimity(31.8%) in orthopedic-surgery each. Mean radiographic case number per patient of simple radiography was sinificant on sex, age, transfer relation in both total and radiographic patients(p<0.05). Mean radiographic case number was highly distributed on male(2.2 case number) in sex, on thirties(2.7) in age, transfered patient(2.7) in patient type, and on neurosurgery(3.4) in diagnostic charged part. Total radiographic case number in regional part was highly distributed on chest(499 case number). Considering the above results, emergency radiographer should take care of the elder patient in emergency radiography and get hold of injury mechanism to decrease possible secondary injury during radiography. Because of high radiography rate of urinary system in special study, radiographer should know well about dealing with contrastmedia administration and related instrument. All radiographer who take charge emergency patient should cope with a emergency situation during radiography, Because head trauma patients is very important in patient care, especilly in CT at night, charged doctor should be always silted with CT room and monitoring-patient. Radiography was reqested by many diagnostic department in ER. Considering that rate of simple radiography is high, special room for emergency radiography should be established in ER area, and the radiographer of this room should be stationed radiologic technician who is career and can implement emergency patient care.

  • PDF

The Clinical Value about Pulmonary Tuberculosis of Indirect Chest Radiography in Physical Examination for Conscription (징병 신체 검사시 집단 흉부 간접 방사선 촬영의 폐결핵 관련한 진단적 유용성)

  • Park, Sung Bin;Choi, Byeong-Kyoo;Ha, Keun Woo;Seo, Joon Beom
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.4
    • /
    • pp.356-360
    • /
    • 2005
  • Background : This study examined the clinical utility of using indirect chest radiography during a physical examination of new conscripts for determine the presence of pulmonary tuberculosis. Methods : Over an eight-month period, this study examined 25386 people who underwent a physical examination after conscription. The abnormal findings on mass miniature radiography were followed-up using direct chest radiography. The positive predictive value of mass miniature radiography and direct chest radiography was compared. The incidence, degree of infiltration and clinical outcome of active pulmonary tuberculosis were also evaluated during a follow-up examination. Results : The positive rate of mass miniature radiography was 1.19% (n=302). Various lesions were identified: Parenchymal lesions (n=109), mediastinal lesions (n=6), cardiovascular lesions (n=45), pleural lesions (n=49), bony lesions (n=90) and miscellaneous lesions (n=7). The incidence of active pulmonary tuberculosis by mass miniature radiography was 0.26% (n=67). The first diagnosis was made in 50 people; active pulmonary tuberculosis (n=42), pneumonia (n=1), a mediastinal mass (n=1), a rib fracture (n=2) and a pneumothorax (n=4). Most cases of active pulmonary tuberculosis were mildly infiltrated and either improved or were cured by the follow-up examination. Conclusion : Although mass miniature radiography in a physical examination after conscription has limitations, but it is a useful means for detecting the presence of early disease, particularly in active pulmonary tuberculosis.

The Effect of X-ray Tube Potential on the Image Quality of Digital Chest Radiography with an Amorphus Silicon Flat Panel Detectors (비정질 평판형 측정기를 이용한 디지털 흉부 방사선 영상에서의 효과적인 관전압 선택)

  • Kim, Jung-Min;Im, Eun-Kyung
    • Journal of radiological science and technology
    • /
    • v.28 no.4
    • /
    • pp.273-277
    • /
    • 2005
  • The rapid development in digital acquisition technology in radiography has not been accompanied by information regarding optimum radiolographic technique for use with an amorphus silicon flat panel detector. The purpose of our study was to compared image quality and radiation dose of an amorphus silicon flat panel detectors for digital chest radiography. All examinations were performed by using an amorphus silicon flat panel detector. Chest radiographs of an chest phantom were obtained with peak kilovoltage values of $60{\sim}150kVp$. Published data on the effect of x-ray beam energy on image quality and patient dose when using an amorphus silicon flat panel detector. It is important that radiographers are aware of optimum kVp selection for an amorphus silicon flat panel detector system, particularly for the commonly performed chest examination.

  • PDF

A Study of the Patient Dose in Chest Radiography (흉부(胸部) X선검사시(線檢査時) 환자(患者)의 피폭선양(被曝線量)에 대(對)한 연구(硏究))

  • Kim, Chang-Kyun
    • Journal of radiological science and technology
    • /
    • v.13 no.1
    • /
    • pp.3-9
    • /
    • 1990
  • A study was carried out to investigate the technical factors and the patient dose (entrance and absorbed dose) in chest P-A radiography based on the 86 hospitals in Seoul from July 1 to July 30, 1989. As a result of this study, main finding were as follow : 1. 51.2% of the surveyed hospitals made use of $60{\sim}69\;kVp$ as tube voltage in chest radiography 2. The majority of the surveyed(88.3%) have the use of $6{\sim}20\;mAs$ as tube current-time. 3. Percentage absorbed doses in patient were showed more than 90 percent in every tube voltage. 4. Object densities were all much the same in all tube voltages. 5. 48.8% of surveyed entrance doses ranged from $100\;{\mu}Sv$ to $190\;{mu}Sv$, and the mean dose was $158\;{\mu}Sv$.

  • PDF

General Radiography Usage and Exposure Dose of Korean Elderly: Based on Data from Aged Patients in 2016 (한국 노인의 일반촬영 이용량 및 피폭선량: 2016년 고령환자데이터 기반)

  • Gil, Jong-Won;Yoo, Se-Jong;Lee, Won-Jeong
    • Journal of radiological science and technology
    • /
    • v.44 no.5
    • /
    • pp.495-502
    • /
    • 2021
  • This study aims to provide basic data for elderly health insurance policy and medical radiation safety management by analyzing the general radiography usage and exposure dose of the elderly in Korea. The effective dose for each general radiography was calculated using the ALARA-GR program for 260 general radiography codes selected from 'National Health Insurance Care Benefit Cost'. The usage of general radiography was analyzed in the 2016 elderly patient data of the Health Insurance Review and Assessment Service, and the effective dose for each general radiography was applied. The general radiography usage and exposure dose per person aged 65 years and over was 6.47 cases and 0.56 mSv. Females showed higher value than males as 7.15 cases and 0.66 mSv(p<.001). By age, those between 75 and 79 showed the highest number as 6.97 cases and 0.62 mSv(p<.001). Those who were supported by Medical Aid showed higher value than those who were insured by National Health Insurance as 8.82 cases and 0.76 mSv(p<.001). In addition, the ratio by radiography was in the order of Chest 20.85%, Knee Joint 15.58%, and L-spine 14.67%, and the exposure dose was L-spine 29.40%, Chest 15.82%, Abdomen 7.97%, and Entire Spine 7.20%. General radiography, which is widely used due to the high frequency of diseases in the elderly population should be taken into consideration when establishing health insurance policies. In addition, it is necessary to check whether the general radiography with high exposure dose is performed as a routine examination without considering medical necessity.

The Usefulness of Magnification of the Heart Shadow in Chest Radiography (흉부 촬영시 심음영 확대에 따른 유용성에 관한 연구)

  • Park, Eun-Gyung;Lee, Kun-Young;Jung, Young-Tae;Dong, Kyung-Rae;Ji, Youn-Sang
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.119-125
    • /
    • 2010
  • In order to demonstrate the value of long-distance radiography, we have studied how distance affects images in chest frontal radiography and compared short-distance and long-distance images in chest lateral radiography. Cardiothoracic ratio(CTR %) of 50 patients with no disease in the chest(10 each at the age of 20~60) were evaluated in Supine AP(100 cm), Sitting AP(100 cm), Sitting AP(180 cm), and Erect PA(180 cm). In lateral radiography, we evaluated and compared left lateral radiography(100 cm and 180 cm) of the patients based on the horizontal maximum of the heart. The average value of CTR(%) were 0.48 in Erect PA(180 cm), 0.52 in Supine AP(100 cm), 0.50 in Sitting AP(100 cm), 0.49 in Sitting AP(180 cm), which were Supine AP(100 cm) > Sitting AP(100 cm) > Sitting AP(180 cm) > Erect PA(180 cm). The average value of Maximum transverse diameter of left of the cardiac(MLD), which showed how much axis of spine was slanted to the left, was 90.67 mm in Erect PA(180 cm), 103.92 mm in Supine AP(100 cm), 93.54 mm in Sitting(100 cm), 89.84 mm in Sitting AP(180 cm), 58.11 mm in the minimum value and 118.79 mm in the maximum value. The average value of Maximum transverse diameter of right side of the cardiac(MRD), which suggested how much axis of spine was slanted to the right, was 47.18 mm in Erect PA(180 cm), 48.12 mm in Supine AP(100 cm), 44.98 mm in Sitting AP(180 cm), and the minimum value 26.84 mm and the maximum value 65.30 mm. There was no standard method to calculate; therefore, the horizontal maximum of the heart was used for lateral radiography. The average value was 121.07 mm in 100 cm and 109.76 mm in 180 cm. Sitting AP(180 cm) among the types was closest to C-PA(180 cm). As a result, during C-AP radiography, long-distance radiography lessened shadow of the heart more than that of short distance, Sitting position more than Supine position.

  • PDF

Evaluation of Unexposed Images after Erasure of Image Plate from CR System (CR 시스템에서 IP 잠상의 소거 후 Unexposed Image의 평가)

  • Lim, Bo-Yeon;Park, Hye-Suk;Kim, Ju-Hye;Park, Kwang-Hyun;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.199-207
    • /
    • 2009
  • It is important to initialize Image Plate (IP) completely for removing residual latent image by sodium lamp for reliability and repeatability of computed radiography (CR) system. The purpose of this study was to evaluate latent images of computed radiography (CR) images respect to delay time after erasure of foregone latent image and its effect, and erasure level. Erasure thoroughness for CR acceptance test from American Association of Physicist in Medicine (AAPM) Report 93 (2006) was also evaluated. Measurements were made on a CR (Agfa CR 25; Agfa, BELGIUM) system. Chest postero-anterior (PA), Hand PA, L-spine lateral radiographs were chosen for evaluation. Chest phantom (3D-torso; CIRS, USA) was used for Chest PA and L-spine lateral radiography. For Hand PA radiography, projections was done without phantom. Except Hand PA radiographs, noise was increased with delay time, and ghost image was appeared on overexposed area. Effect of delay after erasure on latent image was not seen on naked eye, but standard deviation (SD) of pixel value on overexposed area was relatively higher than that of other areas. On Hand PA and Chest PA radiographs, noise were not occurred by adjustment of erasure level. On L-spine lateral images at lower erasure level than standard level, noise including ghost image were occurred because of high tube current. Erasure thoroughness of CR system in our department was to be proved by these evaluation. The results of this study could be used as a baseline for IP initialization and reliability of CR images.

  • PDF

Assessment of Effective Dose for General Radiography of Adults Based on Diagnostic Reference Level(DRL) by Using PCXMC Program (진단참고준위(DRL)를 기준으로 PCXMC 프로그램을 이용한 성인의 일반촬영 부위별 유효선량 평가)

  • Jeong, Hee-Cheol;Lee, SamYol
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.807-812
    • /
    • 2018
  • In this study, we investigated the conditions used in setting the recommendation level of general radiography diagnostic reference and tried to evaluate the effective dose and biological evaluation using PCXMC v2.0 program. As a result based on the effective dose of male in ICRP 60, the highest Pelvis AP was 0.794 mSv. The lowest Chest PA was 0.050 mSv. In the case of ICRP 103, the highest T-Spine AP was 0.906 mSv The lowest Chest PA was 0.052 mSv. For 40 years old male and female adults, effective doses of general radiography were evaluated and even if the medical exposures are not subject to the limit of dose, efforts should be made to reduce the medical exposures of the people by keeping the dose below the recommended amount in order to minimize the probable effect of radiation hazard.

A Survey on Medical Radiation Dose by the Radiographic Conditions of Chest (흉부 X선촬영 조건에 따르는 의료피폭에 관한 조사연구)

  • Huh, Joon;Kim, Sun-Soo;Park, Jun-Chul
    • Journal of radiological science and technology
    • /
    • v.15 no.1
    • /
    • pp.79-87
    • /
    • 1992
  • It is a matter of common knowledge that madical radiation is most accented for of radiation is doses applied to the whole of people, and of them the radation dose by radiography diagnosis is mainly prevalent. In applying X-rays to a certain man for radiography diagnosis a radiologyist will have to have an absolute sense of mission concerning the reduction and prevention of the patient's radiation dose as the radiologyist obligation. Accordingly, the radiography conditions of the patient's chest employed 197 medical facilites were surveyed and skin dose was computated by the IPH Bit system and examined. As a result, it was shown that the average skin dose was $288\;{\mu}Sv$, its minimum value was $1600\;{\mu}Sv$, which was over 32 times its minimum value. This shows that the appropriate radiography method has not been applied at applying X-ray to the patient. It comes from the performance of X-ray equipment, the choice of auxiliary equipment materials etc. But the most important thing is to master the appropriate radiography condition, and therefore this point will have to be kept in mind.

  • PDF