• 제목/요약/키워드: Chest Radiography

검색결과 369건 처리시간 0.031초

한냉글로불린혈증 환자에서 발생한 급성호흡곤란증후군 1예 (A Case of Cryoglobulinemia-induced Acute Respiratory Distress Syndrome)

  • 김병규;심재정;정기환;신정호;이승헌;공희상;김제형;박상면;신철;인광호;강경호;유세화
    • Tuberculosis and Respiratory Diseases
    • /
    • 제51권2호
    • /
    • pp.155-160
    • /
    • 2001
  • 한냉글로불린혈증에 의한 급성호흡곤란증후군은 극히 드문 것으로 보고되었다. 저자 등은 B형 간염을 가진 환자에서, 한냉글로불린혈증과 그에 인한 급성호흡곤란 증후군이 발생한 1예를 경험하였기에 보고하는 바이다.

  • PDF

Digital Radiography 환경하에서 일반촬영시 적정 노출조건에 따른 CR과 DDR의 Image Quality 비교 (The Comparison of Image Quality between Computed Radiography(CR) and Direct Digital Radiography(DDR) which Follows the Proper Exposure Conditions in General Photographing under the Digital Radiography(DR))

  • 김진배;강충환;강성진;박수인;박종원;김영수;김승식
    • 대한디지털의료영상학회논문지
    • /
    • 제5권1호
    • /
    • pp.64-77
    • /
    • 2002
  • DR은 방사선과 뿐만 아니라 병원전체의 생산성 및 업무의 효율성에서 중요한 요소로 자리잡아가고 있다. DR환경은 CR보다 다양한 Parameter를 가지고 있어 양질의 의료서비스 제공이 가능하다. 현재 각 병원의 방사선과는 Film-Screen system에서 Full-PACS를 통한 DR 환경으로 변화하고 있다. Full-PACS를 사용하고 있는 본원에서는 DR환경에서의 일반촬영 System중 CR과 DDR의 최적노출조건과 그에 따른 Image quality가 어떻게 표현되는 지 알아보고자 본 연구에 임하게 되었다. 본 실험을 통하여 CR과 DDR의 Image quality는 같은 노출조건 하에서는 DDR이 더욱 우수하다는 것을 알 수 있었다. 그리고 DDR system에서도 AEC를 사용했을 때의 Image에 대한 점수가 사용하지 않았을 때보다 조금 더 높은 것을 알 수 있다. 특히 Skull, Chest부분에서는 DDR의 AEC기능이 Image quality를 향상시키는데 유용함을 간접적으로 알 수 있었다. (AEC기능이란 피사체를 통과한 X선을 Detector내에 있는 Ion chamber를 이용하여 전리전류를 검출하는 기구로서 적정농도 도달 시 X선의 조사를 제어하도록 되어있다.) 이 기능은 다양한 피사체의 두께에 따른 노출조건을 고려하지 않아도 적정농도를 나타낼 수 있기 때문에 보다 손쉬운 촬영이 이루어질 수 있다. 이 실험결과로 좋은 Image quality를 얻기 위해서는 적절한 노출조건의 선정이 중요함을 알 수 있었다. 앞으로도 무한한 발전 가능성이 있는 DDR system에 대한 연구가 좀 더 필요하겠다.

  • PDF

Digital Radiography(DR)에서 검출기의 X선 조건에 따른 흡수선량 및 영상화질 변화에 관한 연구 (Study on the Change of Absorbed Dose and Image Quality according to X-ray Condition of Detector in Digital Radiography(DR))

  • 황준호;정재호;김현수;이경배
    • 한국콘텐츠학회논문지
    • /
    • 제17권9호
    • /
    • pp.99-106
    • /
    • 2017
  • 본 연구는 진단용 검출기가 결함이 발생하는 경우 환자의 방사선 피폭과 영상의 화질에 영향을 줄 수 있다는 점에 착안하여 실험을 진행하였고 선량분석을 통해 검출기 성능을 신호 대 잡음비와 대조도 대 잡음비로 평가하였다. 선량계, 조직등가팬텀을 이용해 흡수선량과 신호 대 잡음비, 대조도 대 잡음비를 측정하였다. 실험방법은 팬텀 후면에 부착하여 나온 선량 값과 검출기 뒤에 부착한 선량 값이 일치하는지를 비교하였고 두개부 흉부 복부의 조건을 각각 75 kVp 25 mAs, 110 kVp에 8 mAs, 80 kVp에 20mAs로 설정하고 검사하였다. 그 결과 검출기의 뒤쪽에 부착한 선량값은 0.004 mGy, 0.006 mGy, 0.003 mGy로 나타났고, 팬텀 후면은 0.006 mGy, 0.016 mGy, 0.017 mGy로 차이가 있었다. 두 값을 일치시키기 위해서 조건이 증가하였고 신호 대 잡음비와 대조도 대 잡음비는 88.32, 88.10, 4.09, 1.63, 87.94, 79.97에서 93.87, 93.75, 4.91, 4.03, 92.02, 84.92로 증가하였다. 본 연구를 통해 검출기가 노후화 되는 경우 기기의 수명단축과 환자의 선량증가의 원인이 되었으며 또한 영상화질의 개선효과도 미비하다는 것을 알 수 있었다.

디지털 흉부 측와위 후전방향 검사 시 Ion chamber조합 설정과 관전압 변화에 따른 장기선량 및 화질 평가 (Evaluation on Organ Dose and Image Quality by Changing kVp and Ion Chamber Combination while Taking Digital Chest Lateral Decubitus PA Projection)

  • 이진수;박형후
    • 한국콘텐츠학회논문지
    • /
    • 제15권1호
    • /
    • pp.316-323
    • /
    • 2015
  • 본 연구는 디지털 흉부 측와위 후전방향 검사 시 Ion chamber 설정과 관전압 변화에 따른 피폭선량과 변조전달함수를 측정하여 최적의 진단 영상을 획득하고 환자의 피폭선량을 최소화하는 방안에 대하여 제안하고자 하였다. 실험은 디지털 검출기를 이용하여 흉부 측와위 검사법 중 우측 측와위 상태를 가정하여 Ion chamber를 7가지 조합으로 설정하고, 관전압 변화(100, 110, 120, 130 kVp)에 따라 각 5회씩 촬영하여 표면선량을 측정한 후 평균값을 산출하였다. 실험에서 얻어진 표면선량 값을 몬테카를로 시뮬레이션 프로그램 인 PCXMC에 입력하여 장기선량 및 유효선량을 각각 산출하였고, 영상의 화질을 비교하기 위하여 MTF로 물리적 화질 평가를 하였다. 그 결과 관전압이 높을수록 표면선량이 감소하였으며, Ion chamber 변화에 따른 장기선량과 유효선량은 2번 Ion chamber 설정 시 가장 낮게 나타났으며, 1번 Ion chamber 설정 시 가장 높게 나타났다. MTF 결과는 관전압 120 kVp, 2번 Ion chamber를 설정 시 가장 우수하게 나타났다. 따라서 DR을 이용한 흉부 우측 측와위 촬영 시 화질의 저하 없이 피폭선량을 효과적으로 감소시키며 우수한 영상을 획득할 수 있는 최적의 조합은 관전압 120 kVp와 2번 Ion chamber를 설정하는 것이다.

자동노출제어장치 유·무에 따른 흉부 후·전방향 검사 시 관전압 변화에 따른 선량 및 영상평가 (Dose and Image Evaluation according to Changes in Tube Voltage during Chest X-ray Examination according to Automatic Exposure Control)

  • 주영철;홍동희
    • 한국방사선학회논문지
    • /
    • 제16권7호
    • /
    • pp.871-877
    • /
    • 2022
  • 본 연구는 흉부 방사선검사 시 AEC의 잘못된 사용으로 환자에게 가해지는 피폭선량 및 영상판독의 문제점을 개선하고자 연구를 진행하였다. 검사조건으로 AEC를 이용한 경우와 AEC를 사용하지 않은 경우로 구분하여 영상을 획득 하였으며 0.6 mAs를 고정시키고 110, 100, 90, 80 kVp의 조건으로 촬영하였다. 연구 결과 without AEC 110 kVp가 with AEC보다 선량은 1.17% 감소하였고 100 kVp에서는 17.2% 감소, 90 kVp에서는 30.19% 감소, 80 kVp에서는 46.45% 감소하였다. 폐와 기관, 심장에서 SNR의 평균값의 차이는 with AEC와 without AEC 110 kVp에서 관전압 변화에 따른 통계적인 수치에서는 유의한 차이가 있었으나 실제영상에서 화질의 차이는 미비하였다. 동일한 관전압에서 AEC를 적용하지 않은 경우 특히 without AEC 100kVp에서는 with AEC와 유사한 화질을 유지하면서 선량을 17.2% 감소시킬 수 있었다. 그러므로 흉부 방사선 검사 시 AEC 조건에 의존하기보다 적절한 관전압 선택으로 선량을 낮추면서 검사하는데 조건을 고려해 보아야 할 것으로 사료된다.

류마티스 관절염 환자에서 Adalimumab 사용 후 발생한 사르코이드증 1예 (Sarcoidosis Induced by Adalimumab in Rheumatoid Arthritis)

  • 이승호;김사일;송준석;김태형;손장원;김상헌;윤호주;김태환;신동호;박성수;곽현정
    • Tuberculosis and Respiratory Diseases
    • /
    • 제71권6호
    • /
    • pp.464-469
    • /
    • 2011
  • Adalimumab is a full human monoclonal antibody that inhibits tumor necrosis factor-alpha (TNF-${\alpha}$). This has recently been shown to be effective in the treatment of rheumatoid arthritis (RA), ankylosing spondylitis, and other conditions. Sacoidosis is known to be the target for adalimumab but we describe a patient who has developed sarcoidosis with lung involvement during adalimumab therapy for RA. A 48-year-old woman, who was treated with adalimumab for 5 months, was admitted because of chronic cough and both hilar lymphadenopathy on chest radiography. Chest computed tomography revealed the enlargement of multiple lymph nodes in the right supraclavicular, subcarinal, both hilar and right axillary area. She was diagnosed with sarcoidosis based on the biopsy of supraclavicular lymph node, skin and lung through video-associated thoracoscopic surgery, which was non-caseating epitheloid cell granuloma and excluded from a similar disease. She was treated for sarcoidosis with prednisolone and methotrexate instead of adalimumab.

Prevalence of Latent Tuberculosis Infection among Medical Students in South Korea

  • Jung, Da Ho;Jo, Kyung-Wook;Shim, Tae Sun
    • Tuberculosis and Respiratory Diseases
    • /
    • 제73권4호
    • /
    • pp.219-223
    • /
    • 2012
  • Background: We investigated the prevalence of latent tuberculosis infection (LTBI) among medical students in South Korea. Methods: Students from one medical school, who were in second- or third-year classes before clerkship course, were enrolled for three consecutive years in the study. A standard questionnaire was given to each participant, and tuberculin skin test (TST), QuantiFERON-TB GOLD In-Tube (QFT-GIT) assay, and chest radiography were performed. Results: A total of 153 participants were enrolled in the study. The mean age of the subjects was $21.9{\pm}0.9$ years, 105 (68.6%) were male, and 132 (86.3%) had been vaccinated with Bacille Calmette-Gu$\acute{e}$rin (BCG). Four students (2.6%) had a history of contact with tuberculosis (TB) patients during medical practice. No abnormal chest radiograph findings were found for any of the subjects. Of the 153 subjects, 23 (15.0%) tested positive for the TST, and 8 (5.2%) tested positive for the QFT-GIT. The agreement between the two tests was determined to be 0.34 using kappa coefficients. Of the four students who had a history of contact with TB patients, only one subject tested positive for both tests, and the other three students tested negative for both tests. Conclusion: A low prevalence of LTBI was found among medical students before clerkship course in South Korea.

Management of Idiopathic Interstitial Pneumonia Treated only with Traditional Korean Medicine: a Case Report

  • Kang, Ji-Young;Han, Jong-Min;Kim, Jun-Young;Jung, In-Chul;Kang, Wee-Chang;Oh, Young-Seon;Lee, Jin-Woo;Park, Yang-Chun
    • 대한한의학회지
    • /
    • 제35권4호
    • /
    • pp.104-109
    • /
    • 2014
  • Objectives: To present the case of a 76-year-old man diagnosed with idiopathic interstitial pneumonias (IIPs) treated exclusively with traditional Korean medicine (TKM). Methods: The patient was treated with the revised Sasammaekmundong-tang (rSMT), acupuncture, and pharmacopuncture from September 2013 to May 2014 in our outpatient clinic. We prescribed rSMT three times a day for 4 months. Acupuncture and pharmacopuncture were performed twice a week for 9 months. To evaluate therapeutic efficacy, we recorded the patient's chief complaints at each visit, and pulmonary function test was performed at intervals of three months. Chest radiography and chest computed tomography were performed before and after treatment, respectively. Results: During the course of the treatment, dyspnea, cough, sputum, and overall pulmonary function improved. Conclusions: We suggest that traditional Korean medicine (TKM) for IIPs patients might be effective in the control of the main symptoms of IIPs and in the recovery of respiratory function.

고관전압 흉부촬영의 가상결절을 이용한 ROC평가 (Evaluation of ROC Curve in High Kilovoltage Technique Using Simulated Nodules on Chest)

  • 안진신;장명미;정경모;정환;임정기;김종효
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제15권2호
    • /
    • pp.25-30
    • /
    • 1992
  • With transmitted dose through chest which has the problem of wide variations in absorption, simple film/screen combination method makes it diffucult to image lung field, mediastinum and retrocardiac areas. In order to overcome this, it is very common to use the high kilovoltage technique in diminishing the differences between high and low contrast. We have been adopting this method at department of diagnostic radiology, Seoul National University Hospital. To compare the image of it with that of low kilovoltage technique, we did radiographic tests using beans on the skin. We marked off into three anatomical categories such as lungs, mediastinum and near diaphragm, then attached a bean on a marked area at random. In order to compare with high and low, we took a radiography of high($120{\sim}140\;kVp$) and low($70{\sim}90\;kVp$) kilovoltage tehchniques, respectively at the same time. We have done experiments 320 cases. We evaluated the results of test in response to sensitivity(true positive) and specificity(true negative). In evaluating, we gave them points from 1 to 5 according to true or false. With given points by a radiologist having much experiences, we could acquire the percentage of sensitivity and specificity. The percentage made us to get the schematic table of ROC curve of those two methods. Consequently, high kilovoltage technique appeared 18% better than low kilovoltage technique for detecting beans with our apparatus.

  • PDF

일반 X-선 촬영에서의 환자피폭선량에 관한 조사연구 (Patient Dose for Diagnostic Radiological Procedures in Korea)

  • 김유현;최종학;김성수;이창엽;이영배;김철민
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.59-63
    • /
    • 2004
  • IAEA에서 제공한 선량기준은 서양 사람을 기준으로 개발된 것이어서 우리 한국 사람에게는 맞지 않고, 상대적으로 우리나라의 환자선량은 적으리라 예상된다. 따라서 선량기준을 따로 개발해야할 필요가 있다. 그래서 본 연구팀은 병원협회에 등록되어 있는 종합병원 278개를 대상으로 환자 피폭에 대한 설문조사를 실시하였다. 설문회수율은 57.9%였으며 각 병원에서의 촬영조건을 기초로 NDD법을 이용하여 환자 피폭선량을 계산하였고 설문지를 분석한 결과를 보고한다.

  • PDF