• Title/Summary/Keyword: Chest CT scan

Search Result 302, Processing Time 0.027 seconds

Capillary Hemangioma in the Posterior Mediastinum -A case report- (후종격동에 발생한 모세혈관상 혈관종 -1예 보고-)

  • Yang, Joo-Min;Chung, Won-Sang;Kang, Jung-Ho;Kim, Young-Hak;Kim, Hyuck;Jang, Ki-Seok;Park, Moon-Hyang
    • Journal of Chest Surgery
    • /
    • v.37 no.5
    • /
    • pp.460-463
    • /
    • 2004
  • Hemangiomas of mediastinum are rare lesions comprising less than 0.5% of all mediastinal masses. Posterior mediastinal hemangiomas are less common than anterior mediastinal. A 21 year old female was refered to our hospital because of abnormal mediastinal shadow in simple chest X-ray. Chest CT scan and T-spine MRI revealed a posterior mediastinal dumbbell-shaped mass with extradural extension. Surgical excision was performed and pathologic diagnosis was confirmed as 3${\times}$4${\times}$2 cm sized capillary hemangioma.

Small Animal PET Imaging Study of 68Ga-BAPEN (68Ga-BAPEN 소동물 PET영상 연구)

  • Kim, Ji-Who;Lee, Jae-Sung;Yang, Bo-Yeun;Kim, Su-Jin;Kim, Joong-Hyun;Jeong, Jae-Min;Lee, Dong-Soo
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.172-177
    • /
    • 2011
  • The purpose of this study was to analyze $^{68}Ga$-BAPEN dynamic PET image in rat myocardium to evaluate potential of this radiotracer as a perfusion imaging agent. Animal PET/CT scan was done in 9 rats during 120 minutes. Especially we synthesized $^{68}Ga$-BAPEN with kit which is simple and low cost method. PET images showed the in vivo dynamic distribution of $^{68}Ga$-BAPEN in the chest region of rats. Initially $^{68}Ga$-BAPEN PET images showed aorta and liver activities and a few minutes later, $^{68}Ga$-BAPEN moved to myocardium. Regions of interest were drawn on myocardium, liver, lung and blood pool. Time-activity curves showed significant uptake of $^{68}Ga$-BAPEN in myocardium. The contrast ratios of myocardial to blood pool, lung and liver at 60 minutes after injection were 1.66, 2.82 and 0.60. To estimate accurate kinetic parameters, 60 minutes after injection was required to PET scan as myocardium image contrast ratios reached to constant values. As a result, $^{68}Ga$-BAPEN would be suitable radiotracer for PET which can applied to diagnosis of myocardial perfusion diseases after further preclinical and clinical investigations.

Influences of Anesthetics in term of Computed Tomography Bronchial Lumen to Pulmonary Artery Diameter Ratio in Beagle Dogs (비글견의 컴퓨터단층영상에서 기관내강과 폐동맥 직경비율의 마취제에 따른 영향평가)

  • Lim, Jong-su;Hwang, Tae-sung;Yoon, Young-min;Jung, Dong-in;Yeon, Seong-chan;Lee, Hee-chun
    • Journal of Veterinary Clinics
    • /
    • v.33 no.1
    • /
    • pp.6-9
    • /
    • 2016
  • Bronchoarterial (BA) ratio is a commonly used criterion to define airway dilatation despite the lack of normative human and animals. The objective of our study was to compare the range of normal bronchial to accompanying arterial diameter ratio with previous reports on CT scan of the thorax in dogs and assess influence anesthetics on BA ratio in dogs. Dogs undergoing multidetector CT scan of the chest for nonpulmonary conditions at a single center were prospectively identified. High-resolution reconstruction was performed on those included and both airway lumen and vessel diameters were measured in the lobar bronchi of the left cranial (cranial and caudal parts), right cranial, right middle, left caudal, and right caudal lung lobes. Eight dog were included; Mean of the mean BA ratios was $1.43{\pm}0.24$ (95% CI = 1.36 - 1.50) in inhalation anesthetic group. In propofol group, the mean of the mean BA ratios was $1.13{\pm}0.29$ (95% CI = 1.04 - 1.22). In medetomidine group, the mean of the mean BA ratios was $0.89{\pm}0.19$ (95% CI = 0.83 - 0.95). Comparing individual lobes within anesthetic category, there was no signicant difference in mean BA ratio between lung lobes or between dog according to inhalation, propofol, and medetomidine group (P = 0.630, P = 0.878, and P = 0.508, respectively). The BA ratio in these clinically normal dogs was consistent and may be a useful tool in evaluating for bronchiectasis on CT images. However, some different criteria for bronchiectasis were applied by the anesthetic methods.

Evaluation of the Image Quality According to the Pre-set Method in PET/CT Image (PET/CT 영상 획득 시 사전설정법 차이에 따른 영상 질 평가)

  • Park, Sun-Myung;Lee, Hyuk;Hong, Gun-Chul;Chung, Eun-Kyung;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.41-46
    • /
    • 2011
  • Purpose: The result of exam using an imaging device is very closely related with the image quality. Moreover, this image quality can be changed according to the condition of image acquisition and evaluation method. In this study, we evaluated the image quality according to the difference of pre-set method in PET/CT image. Materials & Methods: PET/CT Discovery STe16 (GE Healthcare, Milwaukee, USA), Chest PET phantom (Experiment 1) and 94 NEMA phantom (Experiment 2) were used. Phantom were filled with $^{18}F$-FDG maintaining hot sphere and background ratio to 4:1. In the case of experiment 1, we set the radio activity concentration on 3.5, 6.0, 8.6 kBq/mL. In the case of experiment 2, we set the radio activity concentration on 3.3, 5.5, 7.7, 9.9, 12.1, 16.5 kBq/mL. All experiments were performed with the time-set method for 2 minutes 30 seconds per frame and the count-set method with one hundred million counts in 3D mode after CT transmission scan. For the evaluation of the image quality, we compared each results by using the NECR and SNR. Results: In the experiment 1, both the NECR and SNR were increased as radioactivity concentration getting increased. The NECR was shown as 53.7, 66.9, 91.4. and SNR was shown as 7.9, 10.0, 11.7. Both the NECR and SNR were increased in time-set method. But the count-set method's pattern was not similar with the time-set method. The NECR was shown as 53.8, 69.1, 97.8, and SNR was shown as 14.1, 14.7 14.4. The SNR was not increased in count-set method. In experiment 2, results of both the NECR and SNR were shown as 45.1, 70.6, 95.3, 115.6, 134.6, 162.2 and 7.1, 8.8, 10.6, 11.5, 12.7, 14.0. These results were shown similar patten with the experiment 1. Moreover, when the count-set method was applied, the NECR was shown as 42.1, 67.3, 92.1, 112.2, 130.7, 158.7, and SNR was shown as 15.2, 15.9, 15.6, 15.4, 15.5, 14.9. The NECR was increased but SNR was not shown same pattern. Conclusion: Increment of administered radioactivity improves the quality of image unconcerned with the pre-set method. However, NECR was not influenced by increment of total acquisition counts through simple increasing scan duration without increment of administered activity. In case of count-set method, the SNR was shown similar value despite of increment of radioactivity. So, the administered activity is more important than the scan duration. And we have to consider that evaluation of image quality using only SNR may not be appropriate.

  • PDF

The Consideration of nuclear medicine technologist's occupational dose from patient who are undergoing 18F-FDG Whole body PET/CT : Aspect of specific characteristic of patient and contact time with patient (18F-FDG Whole Body PET/CT 수검자의 거리별 선량 변화에 따른 방사선 작업종사자의 유효선량 고찰: 환자 고유특성 및 응대시간 측면)

  • Kim, Sunghwan;Ryu, Jaekwang;Ko, Hyunsoo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.67-75
    • /
    • 2018
  • Purpose The purpose of this study is to investigate and analyze the external dose rates of $^{18}F-FDG$ Whole Body PET/CT patients by distance, and to identify the main factors that contribute to the reduction of radiation dose by checking the cumulative doses of nuclear medicine technologist(NMT). Materials and Methods After completion of the $^{18}F-FDG$ Whole Body PET/CT scan($75.4{\pm}3.3min$), the external dose rates of 106 patients were measured at a distance of 0, 10, 30, 50, and 100 cm from the chest. Gender, age, BMI(Body Mass Index), fasting time, diabetes mellitus, radiopharmaceutical injection information, creatine value were collected to analyze individual factors that could affect external dose rates from a patient's perspective. From the perspective of NMT, personal pocket dosimeters were worn on the chest to record accumulated dose of NMT who performed the injection task($T_1$, $T_2$ and $T_3$) and scan task($T_4$, $T_5$ and $T_6$). In addition, patient contact time with NMT was measured and analyzed. Results External dose rates from the patient for each distance were calculated as $246.9{\pm}37.6$, $129.9{\pm}16.7$, $61.2{\pm}9.1$, $34.4{\pm}5.9$, and $13.1{\pm}2.4{\mu}Sv/hr$ respectively. On the patient's aspect, there was a significant difference in the proximity of gender, BMI, Injection dose and creatine value, but the difference decreased as the distance increased. In case of dialysis patient, external dose rates for each distance were exceptionally higher than other patients. On the NMT aspect, the doses received from patients were 0.70, 1.09, $0.55{\mu}Sv/person$ for performing the injection task($T_1$, $T_2$, and $T_3$), and were 1.25, 0.82, $1.23{\mu}Sv/person$ for performing the scan task($T_4$, $T_5$, $T_6$). Conclusion we found that maintaining proper distance with patient and reducing contact time with patient had a significant effect on accumulated doses. Considering those points, efforts such as sufficient water intake and encourage of urination, maintaining the proper distance between the NMT and the patient(at least 100 cm), and reducing the contact time should be done for reducing dose rates not only patient but also NMT.

Analysis of Mediatinal Lymph Nodes with Internal Low Density on Contrast Enhanced CT Scan (조영종강 전산화단층촬영상 내부 저밀도 음영을 보이는 종격동 림프절의 분석)

  • Ryu, Young-Hoon;Choe, Kyu-Ok;Hong, Yong-Kook;Kim, Sung-Kyu;Chang, Joon;Lee, Won-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.2
    • /
    • pp.264-279
    • /
    • 1997
  • Background : To analyze the morphologic characteristics of low density lymph node in etiologic differentiation of lymphadenopathy, emphasizing the different features between tuberculosis and lung cancer, on contrast enhanced CT scan. Method : A total of 64 patients who showed low density lymph nodes on chest CT scan were analyzed. Primary causes were tuberculosis (n=28), lung cancer (n=27), malignant lymphoma (n=5) and metastasis from extrathoracic malignancies (n=4). CT scan was performed with 10mm slice thickness and 7 characteristic features were evaluated : location, size, presence or absence of the nonnecrotic lymph node, calcification, perinodal fat obliteration, thickness and evenness of the enhancing rim. Results : In patients with tuberculous lymphadenopathy, lymph nodes with uneven (68.0%) and thick (62.1%) enhancing rim were more common than lung cancer (p<0.05). Low density lymph nodes with less than 1 cm in size were found only in tuberculous lymphadenopathy(n=10). In 48.2% of patients with lung cancer, more than 1 nonnecrotic enlarged lymph node were coexisted, whereas 21.4% in patients with tuberculous lymphadenopathy(p=0.06). However, the size, location and calcification were not statistically significant between tuberculous lymphadenopathy and lung cancer. Conclusion : Tuberculous lymphadenopathy is strongly suggested when enhancing rim of enlarged lymph nodes is uneven and thick, when the coexisting nonnecrotic lymph nodes are few in number and when central low density is encountered in normal sized lymph nodes.

  • PDF

Study of External Radiation Expose Dose on Hands of Nuclear Medicine Workers (핵의학 종사자에서 손 부위의 외부 피폭선량 연구)

  • Park, Jun-Chul;Pyo, Sung-Jae
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.141-149
    • /
    • 2012
  • The aims of this study are to assess external radiation exposed doses of body and hands of nuclear medicine workers who handle radiation sources, and to measure radiation exposed doses of the hands induced by a whole body bone scan with high frequency and handling a radioactive sources like $^{99m}Tc$-HDP and $^{18}F$-FDG in the PET/CT examination. Skillful workers, who directly dispense and inject from radiation sources, were asked to wear a TLD on the chest and ring finger. Then, radiation exposed dose and duration exposed from daily radiation sources for each section were measured by using a pocket dosimeter for the accumulated external doses and the absorbed dose to the hands. In the survey of four medical institutions in Incheon Metropolitan City, only one of four institutions has a radiation dosimeter for local area like hands. Most of institutions uses radiation shielding devices for the purpose of protecting the body trunk, not local area. Even some institutions were revealed not to use such a shielding device. The exposed doses on the hands of nuclear medicine workers who directly handles radioactive sources were approximately twice as much as those on the body. The radiation exposure level for each section of the whole body bone scan with high frequency and that of the PET/CT examination showed that radiation doses were revealed in decreasing order of synthesis of radioactive medicine and installation to a dispensing container, dispensing, administering and transferring. Furthermore, there were statistically significant differences of radiation exposure doses of the hands before and after wearing a syringe shielder in administration of a radioactive sources. In this study, although it did not reach the permissible effective dose for nuclear medicine, the occupational workers were exposed by relatively higher dose level than the non-occupational workers. Therefore, the workers, who closely exposed to radioactive sources should be in compliance with safety management regulations, and take actions to maximally reduce locally exposed dose to hands monitoring with ring TLD.

Evaluation of Lymph Node Staging of Chest CT in NSCLCa (비소세포 폐암의 임파절 병기판정에 대한 흉부 전산화 단층 촬영의 효용성 연구)

  • Sung, Sook-Whan;Kim, Young-Tae;Kim, Doo-Sang;Kim, Joo-Hyun;Lim, Jung-Ki
    • Journal of Chest Surgery
    • /
    • v.31 no.3
    • /
    • pp.271-278
    • /
    • 1998
  • In order to access the value of computed tomography in mediastinal LN staging of NSCLCa, 581 LN stations of 77 patients were selected from 552 patients who were diagnosed as Lung Ca and operated in Seoul National University Hospital from 1992 to 1995. The selection criteria were as follows ; the patients 1) whose preoperative chest CTs were available; 2) underwent curative resection (lobectomy or more) with complete lymph node dissection; 3) whose final pathologic diagnosis were proven to be non-small cell lung cancer. We adopted Receiver Operating Characteristic curve method to determine a proper size criterion for diagnosing malignant mediastinal adenopathy. From curve analysis, we decided the size criterion of lymph node to 1 cm in their short axis. Using this size criterion, it's sensitivity was 43.9%, specificity was 87.4%, and accuracy was 83.1%. Eventhough we couldn't determine the precise size criterion for the adenoca, it seemed that shorter than 1 cm size criterion should be applied in that particular cell type. Lymph node stations associated with the tuberculosis or bronchiectasis tend to be overestimated in nodal staging and have relatively high false positive rate. The low sensitivity of CT scan suggest that radical and complete dissection or precise mediastinal lymph node evaluation through the surgical approach is mandatory.

  • PDF

Three cases of Pulmonary Epithelioid Hemangioendothelioma (폐 유상피 혈관내피종 3예)

  • Lee, Seung-Hyun;Seo, Chang-Gyun;Park, Sun-Hyo;Kim, Kyung-Chan;Kim, Min-Soo;Han, Seung-Beom;Kwon, Kun-Young;Jeon, Young-June
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.1
    • /
    • pp.56-65
    • /
    • 2002
  • A pulmonary epithelioid hemangioendothelioma (PEH) is a rare tumor with a vascular origin. A PEH can arise in many organ systems, such as the lung, liver, bone and soft tissues. It is a borderline malignancy but the clinical course is usually benign. In this report, we describe three cases of PEH. Case 1, a 61-year-old man, had nonspecific chest discomfort and the chest X-ray showed a solitary lung nodule. This nodule was diagnosed by an open lung biopsy. The pathologic findings including abundant necrosis, mitosis and hyperchromatic and pleomorphic nuclei, indicated a malignancy. The electron microscopic study showed Weibel-Palade bodies and the immunohistochemical stain for CD31 showed a positive reaction in the tumor cells, and linear staining along the vascular lumina. Case 2, a 34-year-old man, was admitted for an evaluation of multiple small nodules, incidentally detected a screening chest X-ray. The nodules were diagnosed by a immunohistochemical stain for the factor VIII-related antigen. Case 3, a 34-year-old woman, complained of left pleuritic chest pain. A simple chest film and the chest CT scan revealed multiple bilateral nodules and a left pleural effusion. An immunohistochemical stain for the factor VIII-related antigen was used to diagnose the nodules. Forth-one months after the diagnosis, she died of pulmonary insufficiency.

Pulmonary Nodular Lymphoid Hyperplasia in a 33-Year-Old Woman

  • Park, Ji Ye;Park, Seong Yong;Haam, Seokjin;Jung, Joonho;Koh, Young Wha
    • Journal of Chest Surgery
    • /
    • v.51 no.2
    • /
    • pp.133-137
    • /
    • 2018
  • Pulmonary nodular lymphoid hyperplasia is a reactive lymphoproliferative disease. It is very rare, which means that many aspects of the disease are unknown or have not been proven. Pulmonary nodular lymphoid hyperplasia can be symptomatic or asymptomatic, progressive or not, and solitary or multiple, and a surgical approach is the current treatment of choice. We present a case of pulmonary nodular lymphoid hyperplasia that was visualized as multiple ground glass opacities on a computed tomography (C T) scan, and observed for 1 year because the patient was pregnant. Over this period, the number and extent of the opacities progressed, but no symptoms were reported. A surgical biopsy was done and some remaining lesions regressed on follow-up CT scans, while others progressed, without any appearance of symptoms.