• Title/Summary/Keyword: Chemoport

Search Result 11, Processing Time 0.027 seconds

Catheter Embolism during Chemoport Removal (Chemoport 제거 중 발생한 카테터 색전증)

  • Song, Ki-Byung;Nam, So-Hyun;Kim, Dae-Yeon;Kim, Seong-Chul;Kim, Young-Hwue;Kim, In-Koo
    • Advances in pediatric surgery
    • /
    • v.12 no.2
    • /
    • pp.238-243
    • /
    • 2006
  • Chemoport is widely used in pediatric surgery field. But various complications can occur during the process of insertion or removal of chemoport. Surgeons must be familiar with the treatment of these complications. We had one catheter cuts off during chemoport removal, become a catheter embolism. Interventional radiologic removal was successful. Verifying the length of removed catheter and careful observation of the catheter tip during removal procedure is important to prevent the possibility of catheter embolus. Radiologic intervention was accessible to remove the retained catheter.

  • PDF

Vertebral Venous Congestion That May Mimic Vertebral Metastasis on Contrast-Enhanced Chest Computed Tomography in Chemoport Inserted Patients

  • Jeong In Shin;Choong Guen Chee;Min A Yoon;Hye Won Chung;Min Hee Lee;Sang Hoon Lee
    • Korean Journal of Radiology
    • /
    • v.25 no.1
    • /
    • pp.62-73
    • /
    • 2024
  • Objective: This study aimed to determine the prevalence of vertebral venous congestion (VVC) in patients with chemoport insertion, evaluate the imaging characteristics of nodular VVC, and identify the factors associated with VVC. Materials and Methods: This retrospective single-center study was based on follow-up contrast-enhanced chest computed tomography (CT) of 1412 adult patients who underwent chemoport insertion between January 2016 and December 2016. The prevalence of venous stenosis, reflux, and VVC were evaluated. The imaging features of nodular VVC, including specific locations within the vertebral body, were analyzed. To identify the factors associated with VVC, patients with VVC were compared with a subset of patients without VVC who had been followed up for > 3 years without developing VVC after chemoport insertion. Toward this, a multivariable logistic regression analysis was performed. Results: After excluding 333 patients, 1079 were analyzed (mean age ± standard deviation, 62.3 ± 11.6 years; 540 females). The prevalence of VVC was 5.8% (63/1079), with all patients (63/63) demonstrating vertebral venous reflux and 67% (42/63) with innominate vein stenosis. The median interval between chemoport insertion and VVC was 515 days (interquartile range, 204-881 days). The prevalence of nodular VVC was 1.5% (16/1079), with a mean size of 5.9 ± 3.1 mm and attenuation of 784 ± 162 HU. Nodular VVC tended to be located subcortically. Forty-four patients with VVC underwent CT examinations with contrast injections in both arms; the VVC disappeared in 70% (31/44) when the contrast was injected in the arm contralateral to the chemoport site. Bevacizumab use was independently associated with VVC (odds ratio, 3.45; P < 0.001). Conclusion: The prevalence of VVC and nodular VVC was low in patients who underwent chemoport insertion. Nodular VVC was always accompanied by vertebral venous reflux and tended to be located subcortically. To avoid VVC, contrast injection in the arm contralateral to the chemoport site is preferred.

The study of thermal change by chemoport in radiofrequency hyperthermia (고주파 온열치료시 케모포트의 열적 변화 연구)

  • Lee, seung hoon;Lee, sun young;Gim, yang soo;Kwak, Keun tak;Yang, myung sik;Cha, seok yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.97-106
    • /
    • 2015
  • Purpose : This study evaluate the thermal changes caused by use of the chemoport for drug administration and blood sampling during radiofrequency hyperthermia. Materials and Methods : 20cm size of the electrode radio frequency hyperthermia (EHY-2000, Oncotherm KFT, Hungary) was used. The materials of the chemoport in our hospital from currently being used therapy are plastics, metal-containing epoxy and titanium that were made of the diameter 20 cm, height 20 cm insertion of the self-made cylindrical Agar phantom to measure the temperature. Thermoscope(TM-100, Oncotherm Kft, Hungary) and Sim4Life (Ver2.0, Zurich, Switzerland) was compared to the actual measured temperature. Each of the electrode measurement position is the central axis and the central axis side 1.5 cm, 0 cm(surface), 0.5 cm, 1.8 cm, 2.8 cm in depth was respectively measured. The measured temperature is $24.5{\sim}25.5^{\circ}C$, humidity is 30% ~ 32%. In five-minute intervals to measure the output power of 100W, 60 min. Results : In the electrode central axis 2.8 cm depth, the maximum temperature of the case with the unused of the chemoport, plastic, epoxy and titanium were respectively $39.51^{\circ}C$, $39.11^{\circ}C$, $38.81^{\circ}C$, $40.64^{\circ}C$, simulated experimental data were $42.20^{\circ}C$, $41.50^{\circ}C$, $40.70^{\circ}C$, $42.50^{\circ}C$. And in the central axis electrode side 1.5 cm depth 2.8 cm, mesured data were $39.37^{\circ}C$, $39.32^{\circ}C$, $39.20^{\circ}C$, $39.46^{\circ}C$, the simulated experimental data were $42.00^{\circ}C$, $41.80^{\circ}C$, $41.20^{\circ}C$, $42.30^{\circ}C$. Conclusion : The thermal variations were caused by radiofrequency electromagnetic field surrounding the chemoport showed lower than in the case of unused in non-conductive plastic material and epoxy material, the titanum chemoport that made of conductor materials showed a slight differences. This is due to the metal contents in the chemoport and the geometry of the chemoport. And because it uses a low radio frequency bandwidth of the used equipment. That is, although use of the chemoport in this study do not significantly affect the surrounding tissue. That is, because the thermal change is insignificant, it is suggested that the hazard of the chemoport used in this study doesn't need to be considered.

  • PDF

Interventional Treatment of Chemical Pleuritis and Hemothorax Caused by Iatrogenic Internal Jugular Vein Perforation after Central Venous Port System Implantation: A Case Report (중심정맥포트 삽입 후 의인성 속목정맥 천공에 의한 화학적 늑막염과 혈흉의 중재적 치료: 증례 보고)

  • Do Woo Kim;Young Hwan Kim;Ung Rae Kang
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.6
    • /
    • pp.1459-1465
    • /
    • 2020
  • The perforation of the intrathoracic internal jugular vein during the placement of an implantable central venous chemoport is a rare complication that is manifested by hemothorax or hemorrhagic shock. Furthermore, inappropriate instillation of a chemotherapeutic agent in the chemoport can cause chemical pleuritis, and the diagnosis of these complications prior to the instillation of chemotherapeutic agents and open thoracic surgery is mandatory. We report a patient with chemical pleuritis and hemothorax following an inappropriate instillation of a chemotherapeutic agent, through the perforated right internal jugular vein after placement of an implantable central venous chemoport. Treatment by embolization using coils and N-butyl cyanoacrylate, after percutaneous drainage, was successful.

Compared the Causes of Problematic Chemo-Ports According to the Types of Chemo-Ports(Valved, vs. Non-Valved) (Valve포트와 Non-Valved포트 사용에 따른 문제점의 비교 분석)

  • You, In-Gyu;Lim, Cheong-Hwan;Han, Beom-Hee;Jung, Hong-Ryang;Joo, Yeong-Cheol
    • Journal of radiological science and technology
    • /
    • v.34 no.1
    • /
    • pp.35-41
    • /
    • 2011
  • Total implanted central venous port (TIAP, Chemoport) is widely used in oncology patients because it does not require external dressing and restricts patient activity. Chemoport only requires monthly flushes of heparinized saline to keep the patency of the catheter and probably less prone to infectious complications than tunneled catheter. Despite the extensive use of permanent central venous access in oncology patients, there are only few reports about clinical experience of the Groshong catheter. The purpose of this study is to compare the complication rate between the traditional open-ended (non-valved) chemoports and valved chemoports (Groshong catheter connected to TIAP). During 5 years (Jan 2006 to May 2010), 438 patients received chemoport insertion procedure in our interventional radiology department. Among them 30 patients was referred to our department for problematic chemoports. We compared the cause of problematic chemoports between two types of chemoports (valved, vs. non-valved). Valved chemoports had higher referral rates than non-valved chemoports. When there is a need to insert valved port, different method of insertion and maintenance procedure seems to be necessary. More than 20 ml of flusing with heparinized saline after blood sampling could be a good suggestion. Adequate care of chemoport is essential for long patency. Also following the guideline from the manufacturing company is necessary.

Two Cases of Fractured and Embolized Implanted Central Venous Chemoports in Lung Cancer (폐암환자에서 발생한 피하매몰 중심정맥포트 골절 및 색전증 2예)

  • Ju, Jin Yung;Cho, Jae Yeong;Lim, Jung Hwan;Cho, Gye Jung;Chae, Dong Ryeol;Oh, In Jae;Kim, Kyu Sik;Kim, Yu Il;Lim, Sung Chul;Kim, Young Chul;Song, Sang Yoon;Na, Kook Ju;Kim, Yun Hyun;Kim, Jae Kyu
    • Tuberculosis and Respiratory Diseases
    • /
    • v.63 no.5
    • /
    • pp.449-453
    • /
    • 2007
  • Totally implanted central venous access devices for chemotherapy (chemoport) are being used increasingly in lung cancer patients. Vascular catheters are associated with various complications including infection, thrombosis as well as spontaneous fractures and embolization of the catheter, which is known as 'pinch-off syndrome'. 'Pinch-off syndrome' refers to the compression of a subclavian central venous catheter between the clavicle and first rib resulting in an intermittent or permanent obstruction, which can lead to tears, transection, or embolization. We report two cases of fractured and embolized implanted subclavian venous catheters in which the fragments were removed percutaneously. A 62-year-old man presented with back pain with a duration of a few weeks. The chest radiograph revealed complete transsection and embolization of the catheter into the right atrium. In addition, a 47-year-old woman with a chemoport had a grade 3 pinch-off sign in a chest radiograph demonstrating complete transsection and embolization of the catheter into the pulmonary artery. Both cases were managed by retrieving the embolized distal fragment percutaneously and removing the proximal section of the catheter.

Bloodstream Infections in Children with Cancer between 2005 and 2008 in a Single Center (2005-2008년 단일 기관의 소아 혈액 종양 환자에서의 균혈증 양상: 소아 혈액 종양 환자에서의 균혈증)

  • Kim, Ji Hye;Kim, Hyung Jin;Lim, Yeon Jung;Lee, Young Ho;Oh, Sung Hee
    • Pediatric Infection and Vaccine
    • /
    • v.17 no.1
    • /
    • pp.36-48
    • /
    • 2010
  • Purpose : In children on anticancer chemotherapy, bloodstream infections (BSIs) are a major cause of morbidity and mortality. We investigated febrile episodes and bloodstream infections in pediatric cancer patients to guide proper selection of empiric antibiotics for febrile pediatric hemato-oncologic patients. Methods : All febrile episodes treated in the division of hematology-oncology, the department of pediatrics, Hanyang University Hospital, between July 2005 and June 2008 were reviewed. Episodes with and without bloodstream infections were compared. Results : Forty cases (18.9%, 25 patients) of BSI occurred in 212 febrile episodes (63 patients). Thirty-seven cases (23.6%, 22 patients) of BSI occurred in 157 febrile episodes with neutropenia (54 patients). Microorganisms identified in BSI corresponded to 23 gram-positive bacteria (51.2%), 20 gram-negative bacteria (44.5%), and 2 fungi (4.4%). Rates of BSI between those who had received umbilical cord blood transplantation and those who had received transplantation from other source were significantly different (55.0% vs. 7.7%, P =0.001). No differences in mortality rate were observed among organisms in BSI patients. For febrile episodes the rate of BSI was higher among those with Chemoport than those with Hickman catheter (P =0.029) and gram-positive pathogens were more likely to be associated with Chemoport (P =0.001). Conclusion : The study showed the rate of BSI, distribution of pathogens with regard to neutropenia, transplantation, central venous catheters, and antimicrobial susceptibility of pathogens in order to help guide in the choice of optimal empiric antibiotics in pediatric febrile neutropenic hemato-oncologic patients.

Fracture of an Implantable Central Catheter Due to Pinch Off Syndrome (Pinch off 증후군에 의한 피하매몰형 중심정맥도관의 절단)

  • Yun, Ju-Sik;Oh, Sang-Gi;Song, Sang-Yun
    • Journal of Chest Surgery
    • /
    • v.41 no.4
    • /
    • pp.504-507
    • /
    • 2008
  • Implantable central venous catheters (Chemoport) are increasingly being used for vascular access, parenteral nutrition and administering chemotherapeutic agents. As with most invasive procedures, central venous catheterization is associated with numerous potential complications such as infection, thoromboembolism and occlusion. A rare but serous complication is the catheter fracture. We present here three cases of catheter fracture as a consequence of Pinch off syndrome, and we include a review of the relevant literature.

Central Venous Access for Chemoterapy in Patients with Malignant Disease (항암 화학요법을 받는 환자들에서의 중심정맥삽관술)

  • Kim, Uk-Seong;Kim, Gi-Bong
    • Journal of Chest Surgery
    • /
    • v.26 no.6
    • /
    • pp.483-487
    • /
    • 1993
  • From July 1990 to August 1992,78 Hickman catheters and 22 chemoports were inserted in 98 patients for chemotherapy.We analyzed the clinical data of these patients. The results were as follows: 1]Mean age of patients was 42.8$\pm$1.6[SE] years 2]Male to female ratio was 1.09:1 3]The diseases of the cases were leukemia[66] ,lymphoma[8], stomach cancer[8],uterine cervix cancer[5],ovarian cancer[4],lung cancer[3],aplastic anemia[2],maxillary gland cancer[1],pancreas cancer[1],malignant mesothelioma[1] and multiple myeloma[1] 4]Mean values of preoperative WBC counts,platelet counts,PT and APTT were 31,500$\pm$ 8,132[SE]/mm,104,000$\pm$ 12,200 [SE]/mm,82$\pm$ 1.9[SE]% and 32$\pm$ 0.8[SE] sec,respectively. 5]The average duration of catheter uses was 121.7$\pm$ 17.3[SE]days. 6]The complications were subcutaneous tunnel bleeding or hematoma[2],exit site or subcutaneous tunnel infection[2] and catheter related septicemia[1]. 7]The causes of catheter removal were patient`s death or hopeless discharge[22],completion of treatment[6],subcutaneus hematoma or bleeding[2],exit site or subcutaneous tunnel infection[2] and catheter related septicemia[1].So,we concluded that Hickman catheter and chemoport were useful vascular access for chemotherapy in patients with malignant diseases, with low rate of complication and longterm duration.

  • PDF

The Experience of One Day Surgery in Pediatric Patients (소아 환자의 당일 수술 경험)

  • Nam, So-Hyun;Kim, Dae-Yeon;Kim, Seong-Chul;Gwak, Mi-Jeung;Lee, Dong-Myung;Kim, In-Koo
    • Advances in pediatric surgery
    • /
    • v.12 no.2
    • /
    • pp.147-154
    • /
    • 2006
  • One day surgery in children has been practiced for last 10 years in this institution. This study is to examine its safety and effectiveness for patients younger than 15 years old treated at the Department of Pediatric Surgery, Asan Medical Center, from September. 1996 to December, 2005. A total of 3,709 patients, 37 % of the total pediatric operations, are included in this retrospective study. The most prevalent ages were between 1 and 3 years olds (1,199 patients). Twenty patients were younger than 6 months, and they all had one day surgery safely. Operations were herniorrhaphy in 3,126 patients,followed by excisional biopsy, chemoport removal, and OK 432 injection. There were 12 cases (0.32 %) of unplanned admissions, 7 occurred within 6 months of one day surgery. Perioperative fever was the most common cause of admission in 4 cases. The related conditions of unplanned admission were bleeding in 2 cases and radical surgery in 2. One day surgery in this institution was easily accessible and safe. This is to the result of appropriate selection of patients, cooperation with anesthesiologists, adequate control of postoperative pain, and home care programs.

  • PDF