• Title/Summary/Keyword: Chemiluminescence intensity

Search Result 69, Processing Time 0.02 seconds

Selective determination of mercury (II) ion in aqueous solution by chemiluminescence method (화학발광법에 의한 수용액 중의 선택적 수은(II) 이온 정량)

  • Kim, Kyung-Min;Jang, Taek-Gyun;Kim, Young-Ho;Oh, Sang-Huyb;Lee, Sang-Hak
    • Analytical Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.243-248
    • /
    • 2011
  • A selective determination method of mercury (II) ion in aqueous solution by luminol-based chemiluminescence system (luminol CL system) has been developed. Determination of metal ions such as copper (II), iron (III), chromium (III) ion in solution by the luminol CL system using its catalytic role in the reaction of luminol and hydrogen peroxide has been reported by several groups. In this study, the catalytic activity of mercury (II) ion in the reaction of luminol and hydrogen peroxide was observed by the enhanced CL intensity of the luminol CL system. Based on this phenomenon, experimental conditions of the luminol CL system were investigated and optimized to determine mercury (II) ion in aqueous solution. While mercury (II) ion in mixed sample solution containing mercury (I) and (II) ions highly enhanced the CL intensity of the luminol CL system, the mercury (I) ion could not enhanced the CL intensity. Thus selective determination of the mercury (II) ions in a mixture containing mercury (I) and (II) ions could be achieved. Each concentration of mercury (I) and (II) ions in aqueous solution can be obtained from the results of the CL method that give the concentration of only mercury (II) ion and the inductively coupled plasma (ICP) method that give the total concentration of mercury ions. On the optimized conditions, the calibration curve of mercury (II) ion was linear over the range from $1.25{\times}10^{-5}$ to $2.50{\times}10^{-3}M$ with correlation coefficient of 0.991. The detection limit of mercury (II) ion in aqueous solution was calculated to be $1.25{\times}10^{-7}M$.

Effect of Oxygen Enriched Air on the Combustion Characteristics in a Coaxial Non-Premixed Jet (II) - Flame Structure and Temperature Distribution - (산소부화공기가 동축 비예혼합 제트의 연소특성에 미치는 영향 (II) - 화염의 구조와 온도분포 -)

  • Kwark, Ji-Hyun;Jeon, Chung-Hwan;Jang, Young-June
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.2
    • /
    • pp.223-229
    • /
    • 2004
  • Combustion using oxygen enriched air is known as a technology which can increase thermal efficiency due to increase of the flame temperature. Flame shapes, schlieren photos, OH radical chemiluminescence and local flame temperature were examined as a function of OEC(Oxygen Enriched Concentration) in a coaxial non-premixed jet. With increase of OEC, flame length and width decreased, but its brightness increased significantly, and the size of vortices in the flame also increased. Especially, the reaction around the flame surface became active. The strong OH intensity appeared to be made and moved from middle stream to upper one with increase of OEC, which shows combustion reaction in the upper stream becomes more dominant In addition, the temperature distributions of the flames showed similar tendency with OH radical intensities. A flame with high temperature and strong stability was obtained with increasing OEC of the coflow.

Research about Thermal Stratification Effect on HCCI Combustion Fueled with Primary Reference Fuel (예혼합기의 열적성층화가 PRF연료의 예혼합압축자기착화에 미치는 영향)

  • Lim, Ock-Taeck
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.5
    • /
    • pp.157-163
    • /
    • 2008
  • The HCCI combustion mode poses its own set of narrow engine operating by knocking. In order to solve this, inhomogeneity method of mixture and temperature is suggested. The purpose of this research is to get fundamental knowledge about the effect of thermal stratification on HCCI combustion of PRF -Air mixture. The temperature stratification is made by buoyancy effect in combustion chamber of RCM. The analysis items are pressure, temperature of in-cylinder gas and combustion duration. In addition, the structure of flames using the two dimensional chemiluminescence's images by a framing camera are analyzed. Under stratification, the LTR starting time and the HTR starting time are advanced than that of homogeneous. Further, the LTR period of homogeneous conditions became shorter than that of the stratified conditions. With the case of homogeneous condition, the luminosity duration becomes shorter than the case of stratified condition. Additionally, under stratified condition, the brightest luminosity intensity is delayed longer than at homogeneous condition.

Biophoton Emission of MDCK Kidney Cell with ROS(reactive oxygen species) (Biophoton에 의한 생체 세포수준에서의 항산화 작용에 대한 척도)

  • 백구연;천병수;임재관;이승호;소광섭
    • KSBB Journal
    • /
    • v.18 no.3
    • /
    • pp.170-173
    • /
    • 2003
  • This study was studies biophoton characteristics of Madin-Darby canine kidney cells under the influence of CsA and each cell type (mock, wt, R55A) by employing a Photomultipliertube. $\textrm{H}_2\textrm{O}_2$ was used for producing reactive oxygen species (ROS) in this measurement. ROS is also generated during oxidative metabolism in living organism. Images from a fluorescence show an increase of photon intensity emitted from the sample on the influence of CsA and each cell type (mock, wt, R55A). It is believed chemiluminescence (CL) occurred by ROS is responsible for the biophoton emission. hence PMT measurement might be considered as a useful tool for studying biochemical characteristics in relation to ROS.

Comparison on Physicochemical Properties and Antioxidant Activities of Commonly Consumed Coffees at Coffee Shops in Seoul Downtown (서울 시내 커피전문점에서 판매되는 커피의 이화학적 특성 및 항산화성 비교)

  • 서한석;김수희;황인경
    • Korean journal of food and cookery science
    • /
    • v.19 no.5
    • /
    • pp.624-630
    • /
    • 2003
  • The physicochemical properties and antioxidant activities of commonly consumed espresso and regular coffees, at coffee shops in downtown Seoul, were investigated. Moreover, the characteristics between chain type coffee shops and owner shops were compared using t-tests. The serving temperature and volume of espresso were lower than those for regular coffees. Whereas, the pH and total acidity of espresso were higher than those for regular coffees. Coffees from chain shops, in particular, had a significantly higher pH and lower total acidity than those from owner shops. The L, a and b values of the regular coffees were higher than those of the espresso coffees. With the exception of the a value of regular coffees, all the color values of the coffees from owner shops were higher than those from the chain shops. The intensity of the brownness, soluble solid contents and total phenolic contents of the espresso coffees were about 7∼8, 8∼9 and 4 times higher, respectively, than those of regular coffees. In addition, the free radical scavenging capacities and antioxidant activities of the espresso coffees, using a chemiluminescence assay, were higher than those of regular coffees. Espresso coffees from chain shops, especially, had higher activities of free radical scavenging than those from owner shops. In conclusion, the characteristics of coffees from chain shops were significantly different from those from owner coffee shops.

Symptoms on Generation of Combustion Oscillation and their Detection (진동연소 발생에 관한 징후와 이의 검출)

  • 양영준
    • Journal of Energy Engineering
    • /
    • v.13 no.3
    • /
    • pp.205-213
    • /
    • 2004
  • Usefulness of an optical fiber was demonstrated by detecting the generation of self-excited combustion oscillations. OH chemiluminescence intensity detected by the optical fiber showed mostly excellent agreement with those obtained by high speed CCD camera measurements when combustion oscillations were strong. Symptoms of self-excited combustion oscillation were also studied in order to predict the onset of combustion oscillation before it proceeded to a catastrophic failure. For the purpose, we have found and proposed unique measures to tell the onset of self-excited combustion oscillations based on the careful statistics of fluctuating properties in flames, such as pressure or omission of OH radicals.

Experimental Study on Dilution Effect of Exhaust Gas in SNG Combustion on a Model Gas Turbine (가스터빈에서 SNG 연료 조성에 대한 희석제의 배기배출물 저감효과에 대한 실험적 연구)

  • Joo, Seongpil;Yoon, Jisu;Kim, Jeongjin;Kim, Seongheon;Yoon, Youngbin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.7
    • /
    • pp.603-610
    • /
    • 2016
  • This paper describes experimental results about emission and NOx reduction of dilution effect (Nitrogen and carbon dioxide) about various fuel compositions of synthetic natural gas (SNG). Combustion experiment was performed to investigate the combustion characteristics for SNG with various hydrogen ratio in SNG, heat input and equivalence ratio in a partially premixed model gas turbine combustor. NOx emission was similar to each hydrogen ratio and flame characteristics was investigated from OH chemiluminescence images. There was a singularity of CO emission in stoichiometric condition and it can be identified using OH chemiluminescence intensity. In addition, dilution effect was studied in using nitrogen and carbon dioxide as diluent to reduce the NOx emission. Carbon dioxide diluent was more effective to NOx reduction than nitrogen diluent because of its high diluent specific heat and its heat capacity.

The Study of Effects of Variable Parameters on Flame Structure and NOx Emission in Methane/Air Laminar Partially Premixed Flames (메탄/공기 층류 부분 예혼합화염에서 예혼합 정도에 따른 화염구조와 질소산화물의 배출에 미치는 영향에 관한 연구)

  • Oh, Jeong-Seog;Jeong, Yong-Ki;Jeon, Chung-Hwan;Chang, Young-June
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.362-367
    • /
    • 2003
  • It is shown that the effect of variable parameters on flame structures and NOx emissions in the laminar partially premixed methane-air flames with a co-axial Bunsen burner. Objectives of this paper is to understand the effects of flow variables on NOx emissions and the flame structure with OH chemiluminescence, including reconstructed image by abel inversion processing at each conditions. A fuel flowrate of 200 [cc/min] was fixed and the amount of air was varied from 400 to 1200 [cc/min]. The experimental variables were equivalence ratio(${\Phi}$ fuel split percentage(${\sigma}$ and inner tube recess(x/D). Flow conditions were ranged from $1.36{\sim}4.76$(equivalence ratio), $50{\sim}100$(fuel split percentage) and $0{\sim}20$(inner tube recess). NOx analyzer and ICCD camera with a OH filter were used as a main experimental apparatus. In addition, Abel inversion, which is a kind of tomography and valuable to estimate a two-dimensional structure of co-axial flames from cubical information, was employed for combustion diagnostics. Results from this study indicate that the main effects depend on equivalence ratio and next sigma, x/D for NOx production and OH formation. Throughout Abel inversion, we could affirm the maximum position and the tendency of OH radical intensity by variants at five axial heights above the burner exit.

  • PDF

Determination of aromatic amino acids by chemiluminometric assay with Luminol-H2O2-Cu(II) system (Luminol-H2O2-Cu(II) 시스템을 이용한 방향족 아미노산의 화학발광법적 정량)

  • Kim, Kyung-Min;Kim, Young-Ho;Lee, Sang-Hak
    • Analytical Science and Technology
    • /
    • v.25 no.3
    • /
    • pp.171-177
    • /
    • 2012
  • A determination method of aromatic amino acids such as trytophan (Trp), tyrosine (Tyr), and phenylalanine (Phe) using luminol-$H_2O_2$-Cu(II) system has been presented. In the presence of an aromatic amino acid, the enhanced chemiluminescence (CL) intensity of luminol-$H_2O_2$-Cu(II) system was obtained by forming a complex between Cu(II) and the amino acid. Based on the above phenomenon, a sensitive and fast determination of three aromatic amino acids was performed using the CL method in batch-type detection system. To optimize determination conditions, the kinetic influence of an aromatic amino acid on the luminol-$H_2O_2$-Cu(II) system and the effects of $H_2O_2$ and Cu(II) concentration, pH, and buffers were investigated. Under the optimized conditions, the calibration curve was linear over the range from $1.0{\times}10^{-6}$ to $2.0{\times}10^{-5}\;M$ for Trp, $1.0{\times}10^{-6}$ to $2.0{\times}10^{-5}\;M$ for Try, and $2.0{\times}10^{-6}$ to $2.0{\times}10^{-5}\;M$ for Phe, respectively. In this range, reproducibility (RSD, n = 4) of Trp, Try, and Phe were 3.21%, 2.64%, and 2.48%, respectively. The limit of detection ($3{\sigma}/s$) was calculated to be $6.8{\times}10^{-7}\;M$ for Trp, $5.7{\times}10^{-7}\;M$ for Try, and $9.6{\times}10^{-7}\;M$ for Phe.