• Title/Summary/Keyword: Chemical wastewater treatment

Search Result 766, Processing Time 0.026 seconds

Optimization of photo-catalytic degradation of oil refinery wastewater using Box-Behnken design

  • Tetteh, Emmanuel Kweinor;Naidoo, Dushen Bisetty;Rathilal, Sudesh
    • Environmental Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.711-717
    • /
    • 2019
  • The application of advanced oxidation for the treatment of oil refinery wastewater under UV radiation by using nanoparticles of titanium dioxide was investigated. Synthetic wastewater prepared from phenol crystals; Power Glide SAE40 motor vehicle oil and water was used. Response surface methodology (RSM) based on the Box-Behnken design was employed to design the experimental runs, optimize and study the interaction effects of the operating parameters including catalyst concentration, run time and airflow rate to maximize the degradation of oil (SOG) and phenol. The analysis of variance and the response models developed were used to evaluate the data obtained at a 95% confidence level. The use of the RSM demonstrated the graphical relationship that exists between individual factors and their interactive effects on the response, as compared to the one factor at time approach. The obtained optimum conditions of photocatalytic degradation are the catalyst concentration of 2 g/L, the run time of 30 min and the airflow rate of 1.04 L/min. Under the optimum conditions, a 68% desirability performance was obtained, representing 81% and 66% of SOG and phenol degradability, respectively. Thus, the hydrocarbon oils were readily degradable, while the phenols were more resistant to photocatalytic degradation.

Trends of phosphorus recovery technology from sewage sludge ash by wet chemical method (습식 화학적 방법에 의한 하수 슬러지 소각재에서의 인 회수 기술동향)

  • Lee, Min-Su;Kim, Dong-Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.2
    • /
    • pp.131-143
    • /
    • 2018
  • Phosphorus (P) is a limited, essential, and irreplaceable nutrient for the biological activity of all the living organisms. Sewage sludge ash (SSA) is one of the most important secondary P resources due to its high P content. The SSA has been intensively investigated to recover P by wet chemicals (acid or alkali). Even though $H_2SO_4$ was mainly used to extract P because of its low cost and accessibility, the formation of $CaSO_4$ (gypsum) hinders its use. Heavy metals in the SSA also cause a significant problem in P recovery since fertilizer needs to meet government standards for human health. Therefore, P recovery process with selective heavy metal removal needs to be developed. In this paper some of the most advanced P recovery processes have been introduced and discussed their technical characteristics. The results showed that further research is needed to identify the chemical mechanisms of P transformation in the recovery process and to increase P recovery efficiency and the yields.

Effects of TDS on formation of THMs in drinking water treatment (정수처리에서 TDS가 THMs 생성에 미치는 영향)

  • Lee, Seulki;Kwak, Yeonwoo;Hong, Seongho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.3
    • /
    • pp.225-234
    • /
    • 2019
  • This study is focused on effects of factors that affect the formation of THMs during chlorination in drinking water treatment. During the chlorination, chlorine consumption is increased by increasing the initial chlorine dose, the pH and the total dissolved solid (TDS) concentration. Also THMs formation is increased up to $58.82{\mu}g/L$ and $55.54{\mu}g/L$ by increasing initial chlorine concentration and increasing pH. However, concentration of chloroform is decreased by increasing TDS concentration. This is caused the cation($Na^+$) of the total dissolved solids preferentially reacts with the functional groups of the organic material which influence the trihalomethane formation. But total trihalomethane formation is increased up to $127.46{\mu}g/L$ by $Br^-$ contained in the total dissolved solids. DOC reduction was not influenced by any of the factors.

Analysis of Wastewater Reuse Effect on Field-Scale Water Quality (하수처리수의 농업용수 재이용에 따른 포장단위 수질영향 분석)

  • Seong, Choung-Hyun;Kim, Sung-Jae;Kim, Sung-Min;Kim, Sang-Min
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.53 no.4
    • /
    • pp.59-65
    • /
    • 2011
  • The purpose of this study was to analyze the water quality change when wastewater applied to study paddy fields. CREAMS-PADDY (Chemical, Runoff and Erosion from Agricultural Management System) model was used to estimate the field-scale water quality. Simulated results were compared with observed data monitored from Byeongjeom study paddy fields which is located near the Suwon sewage treatment plant in Gyeonggi-do. Significance analysis was performed for the three different irrigation water quality level and five fertilizer reduction scenarios using LSD (Least Significant Difference) and DMRT (Duncan's Multiple Range Test). Total nitrogen was found to be significant for both irrigation water quality level and fertilizer reduction while total phosphorus was not. Annual drainage load for total nitrogen was reduced by 66~92 % compared to irrigation load when treated wastewater irrigated to study paddy fields from 2002 to 2007. Total phosphorus was reduced by 70~86 %.

The Treatment of Flexo-inks Wastewater using Powdered Activated Carbon Including Iron-transition Metal (철 전이금속이 담지된 분말활성탄을 이용한 후렉소잉크 폐수의 처리)

  • Cho, Yong-Duck;Yoon, Won-Jung;Kang, Ik-Joong;Yoo, In-Sang;Lee, Sang-Wha
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.6
    • /
    • pp.996-1003
    • /
    • 2006
  • The absorption characteristics of powdered activated carbon doped by transition-metal nanoparticles were investigated to enhance the remove efficiencies of $TCOD_{Mn}$ and Color from the flexo-inks wastewater. According to the adsorption dynamics of PAC and MPAC, the optimal dosage of activated-carbon adsorbents was 3 g/L under the reaction conditions of pH6.0, 30 mill of reaction time, 240 rpm of mixing intensity. The removal efficiencies by the optimal dosages were maximized as 19% $TCOD_{Mn}$, 57% Color for PAC and 88% $TCOD_{Mn}$, 95% Color for MPAC. Freundlich indexes of isotherm absorption were estimated as follows: i) For PAC, k=-8.11, 1/n=2.98, r=0.91 in the raw water, and k=0.14, b/n=0.75, r=0.96 in the biological treatment water, ii) For MPAC, k=2.69, 1/n=0.21, r=0.80 in the raw water, and k=0.74, 1/n=1.17, r=0.95 in the biological treatment water. MPAC (Powdered activated carbon doped by transition-metal nanoaprticles) was very effective in the removal of organics from the raw water and biological treatment water, as Freundlich indexes of 1/n for both types of water were estimated less than 2.0.

Optimal Condition of Operation Parameter for Livestock Wastewater Treatment using Photo-Fenton Process (PHOTO-FENTON 공정을 이용한 축산폐수처리시 운전인자의 최적조건)

  • Park, Jae-Hong;Chang, Soon-Woong;Cho, Il-Hyoung
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.3
    • /
    • pp.284-288
    • /
    • 2005
  • In this study, photochemical advanced oxidation processes (AOPs) utilizing the Photo Fenton reaction ($Fe^{2+}+H_2O_2+UV$) were investigated in lab-scale experiments for the treatment of livestock wastewater. For the experimets, the livestock wastewater was pretreated by coagulation with $3,000mg/L\;FeCl_3$. The optimal conditions for Photo-Fenton processes were determined: pH was 5, the concentration of ferrous ion (Fe II) was 0.01 M. The concentration of hydrogen peroxide was 0.1 M, and molar ratio ($Fe^{2+}/H_2O_2$) was 0.1. The optimal reaction time was 80 min. Under the optimal condition of Photo-Fenton process, chemical oxygen demand (COD), color and fecal coliform removal efficiencies were about 79, 70, and 99.4%, respectively and sludge production was 7.5 mL from 100 mL of solution.

Performance of GACC and GACP to treat institutional wastewater: A sustainable technique

  • Khaleel, Mohammed R.;Ahsan, Amimul;Imteaz, M.;El-Sergany, M.M.;Nik Daud, N.N.;Mohamed, T.A.;Ibrahim, Buthainah A.
    • Membrane and Water Treatment
    • /
    • v.6 no.4
    • /
    • pp.339-349
    • /
    • 2015
  • Experiments were carried out using granular activated carbon (GAC) adsorption techniques to treat wastewater contaminated with organic compounds caused by diverse human activities. Two techniques were assessed: adsorbent GAC prepared from coconut shell (GACC) and adsorbent GAC from palm shell (GACP). A comparison of these two techniques was undertaken to identify ways to improve the efficiency of the treatment process. Analysis of the processed wastewater showed that with GACC the removal efficiency of biochemical oxygen demand (BOD), chemical oxygen demand (COD), turbidity, total suspended solids (TSS) and total dissolved solids (TDS) was 65, 60, 82, 82 and 8.7%, respectively, while in the case of GACP, the removal efficiency was 55, 60, 81, 91 and 22%, respectively. It can therefore be concluded that GACC is more effective than GACP for BOD removal, while GACP is better than GACC for TSS and TDS removal. It was also found that for COD and turbidity almost the same results were achieved by the two techniques. In addition, it was observed that both GACC and GACP reduced pH value to 7.9 after 24 hrs. Moreover, the optimal time period for removal of BOD and TDS was 1 hr and 3 hrs, respectively, for both techniques.

Polyvinyl Alcohol Degradation by Microbacterium barkeri KCCM 10507 and Paenibacillus amylolyticus KCCM 10508 in Dyeing Wastewater

  • Choi, Kwang-Keun;Park, Chul-Hwan;Kim, Sang-Yong;Lyoo, Won-Seok;Lee, Sang-Hun;Lee, Jin-Won
    • Journal of Microbiology and Biotechnology
    • /
    • v.14 no.5
    • /
    • pp.1009-1013
    • /
    • 2004
  • The purpose of this study was to investigate the degradation of PVA (polyvinyl alcohol) contained in dyeing wastewater by a mixed culture of Microbacterium barkeri KCCM 10507 and Paenibacillus amylolyticus KCCM 10508. Firstly, synthetic wastewater which contained different initial concentrations of PVA varying from 50 to 3,500 mg/l were tested to obtain optimal PVA biodegradation activity of isolated strains, and the above two strains were found to degrade PVA up to 90%, when the initial concentration of PVA was 750 mg/l and below. Next, dyeing wastewater was tested by a nixed culture of the two isolated strains, and 42% and 55% of the initial concentrations of PVA and COD, respectively, was removed after five days. MLSS was gradually increased from an initial 1,400 to 2,500 mg/l, and the pH was also increased from 5.1 to 7.8. Sterilized dyeing wastewater was tested to find the effect of strains only on the biodegradation of PVA, and PVA degradation ratio and COD removal ratio were 50% and 72.8%, respectively. Thus, the results indicated that these two strains have good ability to degrade PVA and remove COD in dyeing wastewater, Finally, it is expected that if these two strains were used in the dyeing wastewater treatment, good efficiency for PVA degradation and COD removal could be achieved.

Assessment of Removal of Silver Nanoparticle in Sewage Treatment Plant Waste Using Process Simulation (공정 모사를 통한 하수처리장 내 은나노물질 제거 평가)

  • Oh, Seung Yeon;Kim, Younghun
    • Clean Technology
    • /
    • v.20 no.2
    • /
    • pp.160-165
    • /
    • 2014
  • Over the past decade, an increasing number of manufactured nanoparticles (NPs) have been incorporated into products and manufacturing processes due to the rapid innovation and commercialization in the field of nanotechnology. In addition, these nanomaterials and nano-consumer products have increased in quantity per year, and thus their uncontrolled release into the environment is anticipated to grow dramatically in future. However, A current sewage/wastewater treatment plant (SWTP) is being applied to removal of nanoparticles in wastewater. In Korea, the study on the removal of nanoparticles in SWTP was not reported yet. Therefore, in this work, to design pilot STP before field test, two model equations and commercial process simulation were used to derive the desing parameters.

Pharmaceutical residues: New emerging contaminants and their mitigation by nano-photocatalysis

  • Shah, Aarif Hussain;Rather, Mushtaq Ahmad
    • Advances in nano research
    • /
    • v.10 no.4
    • /
    • pp.397-414
    • /
    • 2021
  • The steady growth in population has led to an enhanced water demand and immense pressure on water resources. Pharmaceutical residues (PRs) are unused or non-assimilated medicines found in water supplies that originate from the human and animal consumption of antibiotics, antipyretics, analgesics etc. These have been detected recently in sewage effluents, surface water, ground water and even in drinking water. Due to their toxicity and potential hazard to the environment, humans and aquatic life, PRs are now categorized as the emerging contaminants (ECs). India figures in the top five manufacturers of medicines in the world and every third pill consumed in the world is produced in India. Present day conventional wastewater treatment methods are ineffective and don't eliminate them completely. The use of nanotechnology via advanced oxidation processes (AOP) is one of the most effective methods for the removal of these PRs. Present study is aimed at reviewing the presence of various PRs in water supplies and also to describe the process of AOP to overcome their threat. This study is also very important in view of World Health Organization report confirming more than 30 million cases of COVID-19 worldwide. This will lead to an alleviated use of antibiotics, antipyretics etc. and their subsequent occurrence in water bodies. Need of the hour is to devise a proper treatment strategy and a decision thereof by the policymakers to overcome the possible threat to the environment and health of humans and aquatic life.