• Title/Summary/Keyword: Chemical Sensors

Search Result 593, Processing Time 0.026 seconds

Comparative Investigation of Flavors in Cigarettes by Electronic Nose and GC/MS

  • Lee, Yelin;Park, Jin-Won;Lee, Hwan-Woo;Lee, Seung-Yong;Lee, Hyung-Suk
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.35 no.1
    • /
    • pp.20-27
    • /
    • 2013
  • An Electronic Nose(E-Nose) and Gas Chromatography/Mass Spectroscopy (GC/MS) are meanwhile conventional technique to analyze volatile materials in many industries (e.g., food, medicine, environment) and have broad acceptance in the analysis of tobacco products. In this study, an experiment where tin oxide gas sensor array responses and GC/MS profiles are used to characterize the volatile compounds of different cigarettes at the same time is performed and the measurements of two instruments are compared for cigarette samples with a known chemical information. E-Nose and GC/MS were employed to differentiate and match flavored cigarettes with commercial tobacco flavoring agents (lavender, vanilla, peppermint, orange, star anise). For verifying reliability of two systems, the analyses were conducted in terms of amount of flavors in each cigarettes using partial least squares (PLS) and with the principal components analysis (PCA). Various chemical sensors and GC/MS data was reduced into two principal factors (PC1, PC2) for being distinguished with visualized regions. Both systems provided adequate results for odor characteristics of cigarettes in this study with each instrument having its own advantages and disadvantages.

Fabrication of Microbe-Attached SWNT Film for Biosensor Applications and Organophosphorus Compounds Detection (바이오센서 적용을 위한 미생물이 고정된 부양형 탄소나노튜브 필름 제작과 유기인 화합물 검출)

  • Kim, Intae;An, Taechang;Kim, Chang Sup;Cha, Hyung Joon;Kim, Jin Ho;Lim, Soo Taek;Lim, Geunbae
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.35-41
    • /
    • 2014
  • Microbes have been used extensively in various fields of researches and industries but has not been used widely for microfluidic biosensor applications because it is difficult to immobilize properly to a small space. Therefore, we developed a microbial immobilization method for microfluidic devices using single-walled nanotubes and dielectrophoretic force. Single-walled nanotubes and Escherichia coli were aligned between two cantilever electrodes by a positive dielectrophoretic force resulting in a film of single-walled nanotubes with attached Escherichia coli. The optimal condition of film formation without a cell lysis was investigated. Diameter of single-walled nanotubes and electric field (intensity and duration of application) had an effect on the cell viability. On the other hand, the cell concentration of the suspension did not affect the cell viability. Paraoxon was detected using single-walled nanotubes film with attached Escherichia coli that expressed organophosphorus hydrolase. This film which is suspended from the substrate showed faster response time than sensors that are not suspended from the substrate.

Smartphone-based O2 Deficiency Monitoring Device (스마트폰 기반 산소 결핍 모니터링 장치)

  • Loh, Byoung Gook
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.6
    • /
    • pp.117-121
    • /
    • 2015
  • $O_2$-deficiency related accidents occur every year and the most effective way to prevent them is to measure $O_2$ concentration in air with a properly-calibrated $O_2$ monitoring device before entering low-$O_2$ areas. An electro-chemical sensor, Texas Instrument gas platform, and iPhone are used to construct a smartphone-based $O_2$ monitoring device. The smartphone based $O_2$ measuring approach offers advantages of small size, accessibility, internet-connectivity, and programmability in comparison to conventional $O_2$ measuring devices. Multiple gas sensors can be conveniently interfaced to single smartphone, allowing for creating a network of gas sensors distributed across workplaces and remote monitoring via existing mobile communication network. To check proper function of the $O_2$ monitoring device the sensor was exposed to shallow and deep human breaths. The readings decreased immediately after being exposed to exhalation and recovered during inhalation to a calibrated level of 20.9%. When readings decreased below a preset warning value of 19.5%, a low $O_2$ warning was successfully activated on the smartphone.

Polymeric Membrane and Solid Contact Electrodes Based on Schiff Base Complexes of Co(III) for Potentiometric Determination of Perchlorate Ions

  • Soleymanpour, Ahmad;Hanifi, Abdolghafoor;Kyanfar, Ali Hossein
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.9
    • /
    • pp.1774-1780
    • /
    • 2008
  • New PVC based polymeric membrane electrodes (PME) and coated glassy carbon electrodes (CGCE) based on synthesized Schiff base complexes of Co(III); [Co(Salen)$(PBu_3)_2$]$ClO_4$, [Co($Me_2$Salen)$(PBu_3)_2$]$ClO_4$, [Co(Salen)$(PBu_3)H_2O$]$ClO_4$; as anion carriers for potentiometric determination of $ClO_4\;^-$were studied. The PME and also CGCE electrodes prepared with [Co(Me2Salen)$(PBu_3)_2$]$ClO_4$ showed excellent response characteristics to perchlorate ions. The electrodes exhibited Nernstian responses to $ClO_4\;^-$ ions over a wide concentration range with low detection limits ($1.0 {\times} 10^{-6}\;mol\;L^{-1}$ for PME and $9.0 {\times} 10^{-7}\;mol\;L^{-1}$ for CGCE). The electrodes possess fast response time, satisfactory reproducibility, appropriate lifetime and, most importantly, good selectivity toward $ClO_4\;^-$ relative to a variety of other common inorganic anions. The potentiometric response of the electrodes is independent of the pH in the pH range 2.5-8.5. The proposed sensors were used in potentiometric determination of perchlorate ions in mineral water and urine samples. The interaction of the ionophore with perchlorate ions was shown by UV/Vis spectroscopy.

Implementation of Elbow Method to improve the Gases Classification Performance based on the RBFN-NSG Algorithm

  • Jeon, Jin-Young;Choi, Jang-Sik;Byun, Hyung-Gi
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.431-434
    • /
    • 2016
  • Currently, the radial basis function network (RBFN) and various other neural networks are employed to classify gases using chemical sensors arrays, and their performance is steadily improving. In particular, the identification performance of the RBFN algorithm is being improved by optimizing parameters such as the center, width, and weight, and improved algorithms such as the radial basis function network-stochastic gradient (RBFN-SG) and radial basis function network-normalized stochastic gradient (RBFN-NSG) have been announced. In this study, we optimized the number of centers, which is one of the parameters of the RBFN-NSG algorithm, and observed the change in the identification performance. For the experiment, repeated measurement data of 8 samples were used, and the elbow method was applied to determine the optimal number of centers for each sample of input data. The experiment was carried out in two cases(the only one center per sample and the optimal number of centers obtained by elbow method), and the experimental results were compared using the mean square error (MSE). From the results of the experiments, we observed that the case having an optimal number of centers, obtained using the elbow method, showed a better identification performance than that without any optimization.

All-Inorganic Metal Halide Perovskite (CsPbX3; X = Cl, Br, I) Nanocrystal-Based Photodetectors

  • Junhyuk, Ahn;Junhyeok, Park;Soong Ju, Oh
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.6
    • /
    • pp.383-388
    • /
    • 2022
  • Currently, photodetectors are being extensively studied and developed for next-generation applications, such as in autonomous vehicles and image sensors. In this regard, all-inorganic metal halide perovskite (CsPbX3; X = Cl, Br, and I) nanocrystals (NCs) have emerged as promising building blocks for various applications owing to their high absorption coefficients, tunable bandgaps, high defect tolerances, and solution processability. These features, which are typically required for the development of advanced optoelectronics, can be engineered by modifying the chemical compositions and surface chemistry of the NCs. Herein, we briefly review various strategies adopted for the application of CsPbX3 perovskite NCs in photodetectors and for improving device performance. First, modifications of the chemical compositions of CsPbX3 NCs to tune their optical bandgaps and improve the charge-transport mechanism are discussed. Second, the application of surface chemistry to improve oxidation resistance and carrier mobility is described. In the future, perovskite NCs with prospective features, such as non-toxicity and high resistance to external stimuli, are expected to be developed for practical applications.

A novel Fabry-Perot fiber optic temperature sensor for early age hydration heat study in Portland cement concrete

  • Zou, Xiaotian;Chao, Alice;Wu, Nan;Tian, Ye;Yu, Tzu-Yang;Wang, Xingwei
    • Smart Structures and Systems
    • /
    • v.12 no.1
    • /
    • pp.41-54
    • /
    • 2013
  • Concrete is known as a heterogeneous product which is composed of complex chemical composition and reaction. The development of concrete thermal effect during early age is critical on its future structural health and long term durability. When cement is mixed with water, the exothermic chemical reaction generates hydration heat, which raises the temperature within the concrete. Consequently, cracking may occur if the concrete temperature rises too high or if there is a large temperature difference between the interior and the exterior of concrete structures during early age hydration. This paper describes the contribution of novel Fabry-Perot (FP) fiber optic temperature sensors to investigate the thermal effects of concrete hydration process. Concrete specimens were manufactured under various water-to-cement (w/c) ratios from 0.40 to 0.60. During the first 24 hours of concreting, two FP fiber optic temperature sensors were inserted into concrete specimens with the protection of copper tubing to monitor the surface and core temperature change. The experimental results revealed effects of w/c ratios on surface and core temperature developments during early age hydration, as well as demonstrating that FP fiber optic sensors are capable of capturing temperature variation in the concrete with reliable performance. Temperature profiles are used for calculating the apparent activation energy ($E_a$) and the heat of hydration (H(t)) of concrete, which can help us to better understand cement hydration.

Enhanced Gas Sensing Properties of Bi2O3-Core/In2O3-Shell Nanorod Gas Sensors

  • Park, Sung-Hoon;An, So-Yeon;Ko, Hyun-Sung;Jin, Chang-Hyun;Lee, Chong-Mu
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.10
    • /
    • pp.3368-3372
    • /
    • 2012
  • The $Bi_2O_3$ nanowires are highly sensitive to low concentrations of $NO_2$ in ambient air and are almost insensitive to most other common gases. However, it still remains a challenge to enhance their sensing performance and detection limit. This study examined the influence of the encapsulation of ${\beta}-Bi_2O_3$ nanorods with $In_2O_3$ on the $NO_2$ gas sensing properties. ${\beta}-Bi_2O_3-core/In_2O_3-shell$ nanorods were fabricated by a two-step process comprising the thermal evaporation of $Bi_2O_3$ powders and sputter-deposition of $In_2O_3$. Multiple networked ${\beta}-Bi_2O_3-core/In_2O_3-shell$ nanorod sensors showed the responses of 12-156% at 1-5 ppm $NO_2$ at $300^{\circ}C$. These response values were 1.3-2.7 times larger than those of bare ${\beta}-Bi_2O_3$ nanorod sensors at 1-5 ppm $NO_2$. The enhancement in the response of ${\beta}-Bi_2O_3$ nanorods to $NO_2$ gas by the encapsulation by $In_2O_3$ can be accounted for based on the space-charge model.

Classification of Chemical Warfare Agents Using Thick Film Gas Sensor Array (후막 센서 어레이를 이용한 화학 작용제 분류)

  • Kwak Jun-Hyuk;Choi Nak-Jin;Bahn Tae-Hyun;Lim Yeon-Tae;Kim Jae-Chang;Huh Jeung-Soo;Lee Duk-Dong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.7 no.2 s.17
    • /
    • pp.81-87
    • /
    • 2004
  • Semiconductor thick film gas sensors based on tin oxide are fabricated and their gas response characteristics are examined for four simulant gases of chemical warfare agent (CWA)s. The sensing materials are prepared in three different sets. 1) The Pt or Pd $(1,\;2,\;3\;wt.\%)$ as catalyst is impregnated in the base material of $SnO_2$ by impregnation method.2) $Al_2O_3\;(0,\;4,\;12,\;20\;wt.\%),\;In_2O_3\;(1,\;2,\;3\;wt.\%),\;WO_3\;(1,\;2,\;3\;wt.\%),\;TiO_2\;(3,\;5,\;10\;wt.\%)$ or $SiO_2\;(3,\;5,\;10\;wt.\%)$ is added to $SnO_2$ by physical ball milling process. 3) ZnO $(1,\;2,\;3,\;4,\;5\;wt.\%)$ or $ZrO_2\;(1,\;3,\;5\;wt.\%)$ is added to $SnO_2$ by co-precipitation method. Surface morphology, particle size, and specific surface area of fabricated sensing films are performed by the SEM, XRD and BET respectively. Response characteristics are examined for simulant gases with temperature in the range 200 to $400^{\circ}C$, with different gas concentrations. These sensors have high sensitivities more than $50\%$ at 500ppb concentration for test gases and also have shown good repetition tests. Four sensing materials are selected with good sensitivity and stability and are fabricated as a sensor array A sensor array Identities among the four simulant gases through the principal component analysis (PCA). High sensitivity is acquired by using the semiconductor thick film gas sensors and four CWA gases are classified by using a sensor array through PCA.

The Fabrication by using Surface MEMS of 3C-SiC Micro-heaters and RTD Sensors and their Resultant Properties

  • Noh, Sang-Soo;Seo, Jeong-Hwan;Lee, Eung-Ahn
    • Transactions on Electrical and Electronic Materials
    • /
    • v.10 no.4
    • /
    • pp.131-134
    • /
    • 2009
  • The electrical properties and the microstructure of nitrogen-doped poly 3C-SiC films used for micro thermal sensors were studied according to different thicknesses. Poly 3C-SiC films were deposited by LPCVD (low pressure chemical vapor deposition) at $900^{\circ}C$ with a pressure of 4 torr using $SiH_2Cl_2$ (100%, 35 sccm) and $C_2H_2$ (5% in $H_2$, 180 sccm) as the Si and C precursors, and $NH_3$ (5% in $H_2$, 64 sccm) as the dopant source gas. The resistivity of the poly SiC films with a 1,530 ${\AA}$ thickness was 32.7 ${\Omega}-cm$ and decreased to 0.0129 ${\Omega}-cm$ at 16,963 ${\AA}$. The measurement of the resistance variations at different thicknesses were carried out within the $25^{\circ}C$ to $350^{\circ}C$ temperature range. While the size of the resistance variation decreased when the films thickness increased, the linearity of the resistance variation improved. Micro heaters and RTD sensors were fabricated on a $Si_3N_4$ membrane by using poly 3C-SiC with a 1um thickness using a surface MEMS process. The heating temperature of the SiC micro heater, fabricated on 250 ${\mu}m$${\times}$250 ${\mu}m$ $Si_3N_4$ membrane was $410^{\circ}C$ at an 80 mW input power. These 3C-SiC heaters and RTD sensors, fabricated by surface MEMS, have a low power consumption and deliver a good long term stability for the various thermal sensors requiring thermal stability.