• Title/Summary/Keyword: Check system

Search Result 3,301, Processing Time 0.028 seconds

Computer Simulation Study of the Hydrostatic Transmission Applied to the Rack-Bar Type Sluice Gate (래크바형 수문권양기에 적용된 정유압장치의 컴퓨터 시뮬레이션에 의한 작동특성 연구)

  • Lee, S.R.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.6 no.2
    • /
    • pp.14-21
    • /
    • 2009
  • The typical hydraulic hoisting system of the rack-bar type sluice gate is composed of a hydraulic supply unit using an uni-directional pump, a direction control valve, a hydraulic motor, a counter balance valve, and flow control valves. Here, the hydrostatic transmission is applied to the hoisting system of rack-bar type sluice gate to simplify the operation of gate such that the upward and downward direction of gate is simply controlled by the direction of pump rotation. The new hydraulic hoisting system is composed of a bi-directional pump, a hydraulic motor, two counter balance valves, two check valves, two pilot-operated check valves, two relief valves and a shuttle valve. The characteristics of a suggested system are analyzed by computer simulations.

  • PDF

Development of the Rack-Bar Type Sluice Gate Applying the Hydrostatic Transmission (정유압식 래크바형 수문권양기의 개발)

  • Lee, Seong-Rae
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.7 no.4
    • /
    • pp.15-22
    • /
    • 2010
  • The typical hydraulic hoisting system of the rack-bar type sluice gate is composed of a hydraulic supply unit using an uni-directional pump, a direction control valve, a hydraulic motor, a counter balance valve, and flow control valves. Here, the hydrostatic transmission is applied to the hoisting system of rack-bar type sluice gate to simplify the operation of gate such that the upward and downward direction of gate is simply controlled by the direction of pump rotation. The new hydraulic hoisting system is composed of a bi-directional pump, a hydraulic motor, a counter balance valve, two check valves, two pilot-operated check valves, two relief valves and a shuttle valve. The characteristics of a suggested system are analyzed by computer simulations and experiments.

  • PDF

Development of the Rack-Bar Type Sluice Gate Applying the Hydrostatic Transmission (정유압식 래크바형 수문권양기의 개발)

  • Lee, Seong-Rae
    • 유공압시스템학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.86-92
    • /
    • 2010
  • The typical hydraulic hoisting system of the rack-bar type sluice gate is composed of a hydraulic supply unit using an uni-directional pump, a direction control valve, a hydraulic motor, a counter balance valve, and flow control valves. Here, the hydrostatic transmission is applied to the hoisting system of rack-bar type sluice gate to simplify the operation of gate such that the upward and downward direction of gate is simply controlled by the direction of pump rotation. The new hydraulic hoisting system is composed of a bi-directional pump, a hydraulic motor, a counter balance valve, two check valves, two pilot-operated check valves, two relief valves and a shuttle valve. The characteristics of a suggested system are analyzed by computer simulations and experiments.

  • PDF

Implementation of U-Healthcare System for Chronic Disease Management (만성 질환자 관리를 위한 U-Healthcare 시스템 구현)

  • Ryu, Geun-Teak;Choi, Hun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.1
    • /
    • pp.233-240
    • /
    • 2014
  • According to the recent increasing trend of the ages, numbers of patients with chronic diseases are increasing and issues for health care are importantly emerged. In this thesis the research implements U-health care system for health care of patients with chronic diseases. The suggested system for health care of patients with chronic diseases composes bio measurement system, mobile gateway and medical information management server, and bio-signals are composed with modules such as electrocardiogram, blood pressure, blood sugar, oxygen saturation if configured as client. Blood sugar check was considered and implemented to be chosen the ways to transmit through bio measurement system or through gateway. Suggested bio measurement system and mobile gateway are transmitted through Bluetooth. The transmitted biodata is searched by observing health check through mobile gateway, by transmitting through network server, and by using client. By implementing bio signal observation system of patients with chronic diseases, present health check is available by monitoring measured bio data, and various bio signals are transmitted in the mobile environment.

A Study on the Steam Hammering Characteristics by Sudden Closure of Main Stop Valve in the Main Steam Piping System of a Power Plant (화력발전소 주증기배관에서 밸브 차단에 따른 수증기 충격 특성에 관한 연구)

  • Ha, Ji-Soo;Lee, Boo-Youn
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.2
    • /
    • pp.70-77
    • /
    • 2013
  • The present study has been carried out to analyze the effect of steam hammering on the steam piping system including the final superheater, the high pressure turbine, check valve and the first reheater by sudden stoping of main stop valve in a power plant. For the present steam hammering analysis, the well known Flowmaster software has been used to model the steam piping system and the time dependent characteristics of pressure and steam mass flow rate has been conducted. Using the result of the unsteady pressure and steam mass flow rate, the forces acting on the elbows in the piping system has been derived. From the present analysis, it has been elucidated that the elbow just before the main stop valve and the elbow near the connection pipe between bypass pipe and check valve had the largest force among the elbows in the steam piping system. The structural safety diagnostics study on the elbow and the supporting structures of the steam piping system of a power plant will be conducted in the future by the present results of the forces acting on the elbow.

Section Voltage Calculation while a Loop Operation by Tie-Switch Close in a Distribution Management System (배전운영 시스템에서 상시개방 연계 스위치 투입에 의한 루프 운전 중 구간전압 계산 방법)

  • Seo, Jeong-Soo;Lim, Il-Hyung;Park, Jong-Ho;Shin, Yonh-Hak;Choi, Myeon-Song
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.3
    • /
    • pp.397-403
    • /
    • 2016
  • Generally, an electrical distribution configuration is a radial system with one-way current in a distribution management system (DMS). All feeders in a DMS have tie-switches to make radial system. Sometimes, DMS should change a tie-switch for operation. In that case, the tie-switch has to be closed first; then a switch is opened as another tie-switch in order to prevent blackout for customers. At the moment when the tie-switch is closed, distribution system is operated in a loop state, not radial. Before the loop operation, DMS operator has to check any expected events for stable distribution system operation; and the most important event is a mis-operation of a protection relay. In addition, DMS operator should check voltage profile violation but a calculation method of section voltages had not been used. Thus, this paper proposes a calculation method of section voltages at a loop operation in a DMS. The proposed calculation algorithm is verified by Matlap Simulink.

Fire Extinguisher Maintenance System using Smart NFC Communication and Real-Time Pressure Measurement (스마트 NFC 통신과 실시간 압력 측정을 이용한 소화기 유지관리 시스템)

  • Park, Byeng-Cheol;Park, Ki-Hong
    • Journal of Digital Contents Society
    • /
    • v.18 no.2
    • /
    • pp.403-410
    • /
    • 2017
  • In this paper, the fire extinguisher maintenance system using smart NFC communication and the real-time pressure measurement is proposed. The proposed system consists of three steps in the flow of information. The first step is to identify the fire extinguisher through NFC tagging in the fire extinguisher module using the smart device. The fire extinguisher appearance check and the real-time pressure measurement is performed in the second step, and the last step sends the check status information to the management server. In particular, the actual pressure value is calculated based on the angle of the green area and the indicating needle. Some experiments are conducted so as to verify the proposed system, and as a result, the proposed system shows that the administrator can effectively control the status information of fire safety check.

A Fair Flow Control For Baggage Handling System in Airport (공항 수하물 처리시스템의 균형적인 흐름제어 기법 연구)

  • Kim, Junbeom;Kim, Gukhwa;Chae, Junjae
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.10
    • /
    • pp.1317-1327
    • /
    • 2016
  • The baggage handling system (BHS) is one of the most complex system in the airport. A highly economical operating system is required to ensure its performance in consideration of its enormous cost on the extension. Furthermore, the inefficient operation deteriorates not only the system performance but the imbalance among the check-in counters because of a bottleneck on the conveyors downstream. The objective of this research is to improve the performance of both the BHS and the check-in area by efficiently controlling the flow in the merging area on the conveyors. Thus, we suggest a control logic of which the concept is borrowed from data networks. The simulation is used to analyze impacts of the conveyors bottleneck on the check-in area and optimize some parameters used in the suggested logic. We also discuss some observations from the simulation results into several aspects of performance measures.

The Communication Method at the Auto-Startup System using TCP/IP and VXI and Expert System(G2)

  • Kim, Jung-Soo;Joon Lyon
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.1 no.2
    • /
    • pp.141-146
    • /
    • 1999
  • This paper describes the communication method of an auto-startup system. The Auto-Startup system is designed to operate a nuclear power plant automatically during the startup operation . In general , the operations during startup in existing plant have only been manually controlled by the operator. The manual operation caused to the operator mistake. The Auto-Startup system consists of the Distributed Control System(DCS) and G2 (Expert System). Also, Functional Test Facility(FTF) provides the plant's real-data for an Auto-Startup system. So, it is necessary to develop the communication method between these systems. We developed two methods ; one is a network and the other is a hardwire line. To communicate between these systems (DCS-G2 and DCS-FTF) , we developed the communication program. In case of DCS-FTF, we used the TCP/IP and VXI. BUt, in case of DCS-G2 , we , what it called , developed the bridge program using the GSI(G2 Standard Interface). We test to check the function of the important parameter, in time, for analysis of the developed communication method. The results are a good performance when we check the communication time of important parameter. We conclude that Auto-startup system could save heat-up time about at least 5 hours and reduced the change of the reactor operation and trip.

  • PDF

A Study on the Electro-magnetic Wave of Inductive Power Transfer System for Light Railway Transit (경량전철용 유도급전 시스템의 전자파 분석 연구)

  • Park, Chan-Bae;Lee, Byung-Song;Lee, Hyung-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.8
    • /
    • pp.1210-1215
    • /
    • 2012
  • Traction motors for driving and power conversion devices using semiconductor switch are equipped with a transportation systems such as an electrical railway system. Power conversion devices have the possibility of malfunction by external electromagnetic waves. As a result, these could affect the safe operation of the railway. Moreover, the electromagnetic waves above safe limits will be harmful to the passengers inside the railway vehicles or anyone working around the rail-track. For this reason, the importance and need about the reliability check and complement of electromagnetic waves generated from the IPT(Inductive Power Transfer) system have been suggested for the safe application of the IPT system to the railway system. In this study, prediction for the electromagnetic wave properties was conducted through FEM(Finite Element Method) analysis of 5kW-class IPT system design model. Next, the 5kW IPT system prototype was made and then the small-scaled railway vehicle was made to mount the IPT system and the energy management system. Finally, the electromagnetic waves generated from the real small-scaled IPT system were measured and analyzed, and then the reliability check of predictions by FEM analysis were carried out.