• 제목/요약/키워드: Charging Facilities

검색결과 80건 처리시간 0.027초

전철 지중배전선로의 충전전류보상에 관한 연구 (A Study of the Charging Current Effect on Underground Distribution Line in Electric Railway)

  • 김양수;장우진
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.214-218
    • /
    • 2008
  • Because on the high-tension underground distribution line of an electric railway high voltage XLPE Cable two or three circuits between railway stations with a standard as receiving transformer facilities are established at a $30km{\sim}50km$ interval, reactive power in which the phase of a current is larger than that of a voltage is supplied when trains are not working, so when there are no loading or low loading as night. Due to the long-distance trend of the underground distribution system on an alternating current railway distribution line, the terminal voltage of a transformer is over the standard voltage, and after all, commercial cycle overvoltage is continued. To solve this problem, the shunt reactor is installed in middle of power distribution lines to maintain receiver voltage meted under the allowance regulation through control of the reactive power. Also, in case that the thickness of single cable is over $60mm^2$ and length of line is about over 30km, a circuit breaker is broken by shorting shunt ability of charging current in excess of shunt current(31.5A.rms). Therefore, this thesis presents installing the location of shunt reactor for quantitative analysis by using optimum algorism for compensation and control of the charging current.

  • PDF

스마트에너지 방식을 적용한 전력신산업 활성화 모델 사례 연구: ESS, 전기차 충전, 전력수요관리 중심으로 (New Energy Business Revitalization Model with Smart Energy System: Focused on ESS, EV, DR)

  • 신재우
    • 한국IT서비스학회지
    • /
    • 제21권6호
    • /
    • pp.117-125
    • /
    • 2022
  • In respond to climate change caused by global environmental problems, countries around the world are actively promoting the advancement of new electricity industries. The new energy business is being applied to energy storage systems (ESS), electric vehicle charging business, and power demand response using cutting edge technologies. In 2022, the Korean government is also establishing a policy stance to foster new energy industries and making efforts to improve its responsiveness to power demand response with the innovative technologies. In Korea, attempts to commercialize energy power are also being made in the private and public sectors to control energy power in houses, buildings, and industries. For example, private companies, local governments, and central government are making all-out efforts to develop new energy industry models through joint investment. There are forms such as establishing energy-independent facilities by region, establishing an electric vehicle charging system, controlling urban lighting systems with Information technologies, and managing demand between power suppliers and power consumers. This study examined the business model applied with energy storage system, electric vehicle charging business, smart lighting, and power demand response based on information communication technology to examine the site where smart energy system was introduced. According to this study, company missions and government tasks are suggested to apply new energy business technologies as economical energy solutions that meet the purpose of use by region, industry, and company.

LPG 충전소 중대사고의 피해효과에 관한 연구 - 부천 LPG충전소 사고 사례를 중심으로 - (A Study on Damage Effect from Major Accident of LPG Charging Facility - A case study of an LPG Charging and Automotive Outlet -)

  • 노삼규;김태환;함은구;홍창문
    • 시큐리티연구
    • /
    • 제2호
    • /
    • pp.83-98
    • /
    • 1999
  • The LPG station's explosion at Bucheon city was a major accident which with rare frequency of occurrence but large damage effect. Therefore, to prevent similar accident in the future from LPG chargings stations which located at inner urban area, it needs to identify the damage effects of such facilities by comparing theoretically quantities risks-PHAST. The BLEVE effects from the accident showed similar level in case of heat flux, however, the over pressure level reflected at reduced distance. The structure damage to the nearby area showed comparatively large reduction of concrete strength and shape changes through by heat effect while the overpressure effect was small.

  • PDF

국내 액화수소 안전기준 제·개정을 통한 수소산업 안전성 확립 (Establishing the Safety of the Hydrogen Industry Through the Revision of Domestic Liquefied Hydrogen Safety Standards)

  • 김현진;송보희;탁송수;조호연;강승규
    • 한국가스학회지
    • /
    • 제25권6호
    • /
    • pp.98-105
    • /
    • 2021
  • 현재 정부의 「한국판 뉴딜 종합계획」발표('20.7.14, 관계부처 합동)에 따른 수소 생산 및 충전시설 보급 확대에 따라 주요 기업에서 액화수소 제조설비 건설계획 발표에 액화수소 플랜트, 충전소 등 관련시설 구축이 속도감 있게 진행되고 있다. 그러나 국내 액화수소 밸류체인에 따른 생산·저장시설·운송·활용 등에 대한 안전기준이 미흡한 실정이며, 액화수소 전주기에 걸친 안전 기술 및 안전기준 마련이 시급하다. 이에 한국가스안전공사는 액화수소 플랜트를 비롯한 전주기에 걸친 안전기준을 제·개정하고, 이를 통해 국내 안전한 수소 경제를 실현시키고자 한다.

터널 발파에서의 저폭속폭약과 일반폭약의 혼용장약법 (The Mixed Charging Method with Low-velocity Explosives and Normal Explosives in Tunnel Blasting)

  • 강대우;안봉도
    • 터널과지하공간
    • /
    • 제20권4호
    • /
    • pp.252-259
    • /
    • 2010
  • 도심지 터널 즉 터널의 상부 근접한 거리에 보안물건이 존재하는 경우 일반적인 폭약만을 사용해서는 발파진동을 규제치내에서 조절이 불가능하여 폭약공법이 아닌 무진동, 미진동 공법을 사용해야 한다. 하지만 무진동 공법들은 터널굴착공사비가 크게 증가 하게 되며, 또 공사기간도 길어진다. 일반적으로 노천채굴에서는 폭속이 약2,000 m/s 정도인 저폭속폭약이 응용 사용되어 왔으나 터널발파에는 사용되지 않았다. 본 연구에서는 저폭속폭약을 일반 폭약과 공내에서 혼용장약하여 발파작업을 한 결과 일반 폭약으로 발파하는 것보다 진동이 25~30%정도가 감소하였다. 도심지터널 및 보안물건 근접한 터널에서는 진동규제치내에서 미진동으로 시공할 수 있는 저폭속폭약과 일반폭약을 혼용 사용하는 발파 방법을 사용하는 것이 효과적인 것으로 나타났다.

3차 진료기관 외래약국 투약대기시간 단축을 위한 택배 제도 도입 타당성 조사 (The study on appropriateness of adapting door-to-door delivery system for the reducong of waiting time at outpatient pharmacy department in Tertiary care hospital)

  • 송정흡
    • 한국의료질향상학회지
    • /
    • 제3권1호
    • /
    • pp.144-152
    • /
    • 1996
  • Background : Because of introduction of nationwide health care system in 1989 and the improvement of socioeconomic status of population the number of outpatient visiting university hospital has good facilities and manpower has increased. So the waiting time for medical service at university hospital are lengthened. Particularly outpatients complain that waiting for prescribed drugs at pharmacy depart are long. Reducing waiting time at pharmacy depart door-to-door delivery system that the patients applying for door-to-door delivery receive prescribed drug at home without waiting at pharmacy depart were studied. The objective of this study is to analysis the opinion of outpatients for door-to-door delivery system, to study the appropriateness of adopting the system and to produce ideal model for the system. Method : Outpatients waiting drug at pharmacy depart were questioned about door-to-door delivery system. to find the factors affect utilizing the system the logistic regression was used. Result : 83.3% of the patients want to utilize the system without charging, and 72.9% of the patients want to utilized system with charging. 68.3% of patients with charging want to use this system because of long waiting time at pharmacy depart. 50% of patients who do not want to use door-to-door do not use this system because of incorrect delivery. The affecting factors to utilize the system were sex, waiting time, fee. Conclusion : The model for door to door delivery system. 1. door-to-door personnel reside in hospital and the patient want to utilize the system apply for the delivery with charging. 2. The applied drugs dispense at spare time. 3. Delivery company gathers drug at appointed time and delivers. 4. The delivery fee is 2,000-3,000 won. 5. To prevent from loss and changing the drug the name of patient on packet are printed and drug packet are sealed. 6. The company submit the confirm sheet which are written that the patient received drug correctly to hospital. 7. The delivery time of drug is reserved for the convenience of receiving.

  • PDF

Exponential Smoothing기법을 이용한 전기자동차 전력 수요량 예측에 관한 연구 (A Study on the Prediction of Power Demand for Electric Vehicles Using Exponential Smoothing Techniques)

  • 이병현;정세진;김병식
    • 한국방재안전학회논문집
    • /
    • 제14권2호
    • /
    • pp.35-42
    • /
    • 2021
  • 본 논문은 전기자동차 충전시설 확충계획에 중요한 요소인 전기자동차 전력 수요량 예측정보를 생산하기 위하여 Exponential Smoothing를 이용하여 전력 수요량 예측 모형을 제안하였다. 모형의 입력자료 구축을 위하여 종속변수로 월별 시군구 전력수요량을 독립변수로 월별 시군구 충전소 보급대수, 월별 시군구 전기자동차 충전소 충전 횟수, 월별 전기자동차 등록대수 자료를 월 단위로 수집하고 수집된 7년간 자료 중 4년간 자료를 학습기간으로 3년간 자료를 검증 기간으로 적용하였다. 전기자동차 전력 수요량 예측 모형의 정확성을 검증하기위하여 통계적 방법인 Exponential Smoothing(ETS), ARIMA모형의 결과와 비교한 결과 ETS, ARIMA 각각의 오차율은 12%, 21%로 본 논문에서 제시한 ETS가 9% 더 정확하게 분석되었으며, 전기자동차 전력 수요량 예측 모형으로써 적합함을 확인하였다. 향후 이 모형을 이용한 전기자동차 충전소 설치 계획부터 운영관리 측면에서 활용될 것으로 기대한다.

수소 취급설비의 폭발위험장소에 관한 연구 (A Study on Explosive Hazardous Areas in Hydrogen Handling Facility)

  • 표돈영;임옥택
    • 한국수소및신에너지학회논문집
    • /
    • 제30권1호
    • /
    • pp.29-34
    • /
    • 2019
  • Safety of hydrogen handling facilities is needed as supply of hydrogen cars has been expanded recently. In this study, the adequacy of safety regulations of hydrogen handling facilities and the risk of damage with hydrogen leakage were studied. The range of explosion hazard location of the hydrogen filling plant was investigated using the computational fluid dynamics (CFD) method, Explosive hazardous area is influenced by leakage type, hole size and sectional area. When the conditions of KS standard are applied, range explosive hazardous area is expanded 7.05 m, maximum. It is about 7 times larger than exceptional standard of hydrogen station. Meanwhile, distance from leakage point to 25% LEL of hydrogen is investigated 1.6 m. Considering the shape of charging hose, regulation of hydrogen station is appropriate.

고속 발사체 충격을 받은 시멘트 복합체의 철근보강에 따른 파괴 특성에 관한 실험적 연구 (Experimental study on fracture properties with re-bar reinforcement of cement composite subjected to impact of high-velocity projectile)

  • 석원균;김규용;남정수;이예찬;전현수;김영선
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.220-221
    • /
    • 2022
  • With reent changes in energy sources, infrastructure facilities for energy charging are increasing around living areas. The infrastructure facilities have a slight possibility of explosion, and for this research on protection is needed. In this study, the performance of the reinforcement type is reviewed by examining the destructive properties after applying the impact by the high-velocity projectile to the cement composite to which various reinforcement methods are applied.

  • PDF

접지방식이 상이한 철도배전계통의 연장급전을 위한 전기적 특성분석 (Analysis of electric characteristics for extension power supply between different grounding railway distribution system)

  • 정호성;한문섭;이장무;권삼영;박현준
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.736-741
    • /
    • 2005
  • This paper presents electric characteristics analysis and safe configuration for extension power supply between existent 6.6kV ungrounded distribution system and establishment and improvement 22.9kV direct grounding distribution system. For this, we model 6.6kV ungrounded and 22.9kV direct grounding distribution system of urban underground, ground region. and rural electrical, unelectrical region using PSCAD/EMTDC and analyze voltage drop, charging current, ground and short fault through simulation. To analyze electric characteristics of extension power supply, we simulate extension power supply of overhead line of 6.6kV ungrounded system and underground line of 22.9kV direct grounding system of rural electrical region and propose operation condition for safe extension power supply through result of analysis. Characteristics of voltage drop, charging current, ground and short fault appear almost similarly with electrical characteristic of direct power supply. However, because unbalance of phases may cause relay's malfunction of ungrounded system and ground fault current of direct grounding system may demage facilities of ungrounded system, we propose safe system configuration such as impedance grounding system of neutral point.

  • PDF