• Title/Summary/Keyword: Charge-up

Search Result 872, Processing Time 0.028 seconds

Evaluation of the Effective Charge Density on Low Pressure Nanofiltration with the Separation Characteristics of Monovalent and Divalent Solutes in the Production of Drinking Water

  • Oh, Jeong-Ik;Taro, Urase
    • Environmental Engineering Research
    • /
    • v.16 no.1
    • /
    • pp.29-34
    • /
    • 2011
  • The electric charge on a membrane was investigated by analyzing the experimental rejection of various monovalent and divalent ionic solutes. The characteristics of the separation of ionic solutes using various nanofiltration membranes were obtained from an experimental nanofiltration set-up, with a surface area of $40cm^2$ under the operational pressures between 0.25-0.3 MPa. The state of the membrane electric charge was observed using separation coefficients, i.e., the permeation ratio of monovalent to divalent ions. To confirm the state of the membrane charge observed via the separation coefficient, a calculation using the extended Nernst-Planck equation, coupled with the Donnan equilibrium, assuming different electric charge states of the membrane, was compared with the experimental rejection of ionic solutes. The examination of the characteristics of separation using three types of nanofiltration membranes showed that one of the membranes carried a negative/positive double charge density inside, while other two membranes carried either a positive or negative charge density.

A Study on the Optimum Design of Charge Pump PLL with Dual Phase Frequency Detectors (두 개의 Frequency Detector를 가지고 있는 Charge Pump PLL 의 최적설계에 관한 연구)

  • Woo, Young-Shin;Jang, Young-Min;Sung, Man-Young
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.10
    • /
    • pp.479-485
    • /
    • 2001
  • In this paper, we introduce a charge pump phase-locked loop (PLL) architecture which employs a precharge phase frequency detector (PFD) and a sequential PFD to achieve a high frequency operation and a fast acquisition. Operation frequency is increased by using the precharge PFD when the phase difference is within $-{\pi}{\sim}{\pi}$ and acquisition time is shortened by using the sequential PFD and the increased charge pump current when the phase difference is larger than ${\pm}{\pi}$. So error detection range of the proposed PLL structure is not limited to $-{\pi}{\sim}{\pi}$ and a high frequency operation and a higher speed lock-up time can be achieved. The proposed PLL was designed using 1.5 ${\mu}m$ CMOS technology with 5V supply voltage to verify the lock in process. The proposed PLL shows successful acquisition for 200 MHz input frequency. On the other hand, the conventional PLL with the sequential PFD cannot operate at up to 160MHz. Moreover, the lock-up time is drastically reduced from 7.0 ${\mu}s\;to\;2.0\;{\mu}s$ only if the loop bandwidth to input frequency ratio is regulated by the divide-by-4 counter during the acquisition process. By virtue of this dual PFDs, the proposed PLL structure can improve the trade-off between acquisition behavior and locked behavior.

  • PDF

Space Charge Formation in Epoxy/Filler Composites (Epoxy/Filler 복합재료의 공간전하축적 현상)

  • 남진호;이창용;이미경;서광석;강동필
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.11a
    • /
    • pp.171-174
    • /
    • 1995
  • Space charge formation in epoxy loaded with silica and calcium carbonate has been studied. The epoxy itself showed almost no charge at up to 40 kV/mm. The addition of fillers such as SiO$_2$and CaCO$_3$resulted in homocharge formation, which was attributed to the interfacial trapping of injected charge at epoxy/filler interfaces. The amount of charge showed a maximum at 20-40 parts per hundred resin above which the charge decreased gradually. This was tentatively attributed to the enhanced interconection of charge transport path by an increased filler content

  • PDF

High Efficiency High-Step-up Single-ended DC-DC Converter with Small Output Voltage Ripple

  • Kim, Do-Hyun;Kim, Hyun-Woo;Park, Joung-Hu;Jeon, Hee-Jong
    • Journal of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.1468-1479
    • /
    • 2015
  • Renewable energy resources such as wind and photovoltaic power generation systems demand a high step-up DC-DC converters to convert the low voltage to commercial grid voltage. However, the high step-up converter using a transformer has limitations of high voltage stresses of switches and diodes when the transformer winding ratio increases. Accordingly, conventional studies have been applied to series-connect multioutput converters such as forward-flyback and switched-capacitor flyback to reduce the transformer winding ratio. This paper proposes new single-ended converter topologies of an isolation type and a non-isolation type to improve power efficiency, cost-effectiveness, and output ripple. The first proposal is an isolation-type charge-pump switched-capacitor flyback converter that includes an extreme-ratio isolation switched-capacitor cell with a chargepump circuit. It reduces the transformer winding number and the output ripple, and further improves power efficiency without any cost increase. The next proposal is a non-isolation charge-pump switched-capacitor-flyback tapped-inductor boost converter, which adds a charge-pump-connected flyback circuit to the conventional switched-capacitor boost converter to improve the power efficiency and to reduce the efficiency degradation from the input variation. In this paper, the operation principle of the proposed scheme is presented with the experimental results of the 100 W DC-DC converter for verification.

Forecasting and Analysis of Air Meteorological Service Charge using ARIMA-Intervention Time Series Model (ARIMA-개입모델을 이용한 항공기상정보 사용료 징수액 추정 및 적정성 연구)

  • Kim, Kwang-Ok;Park, Sung-Sik
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.26 no.3
    • /
    • pp.9-22
    • /
    • 2018
  • Korea meteorological administration(KMA) has started to levy air meteorological service charge on both national and foreign carriers since 2005. The charge has grown on 2010 and 2014 twice. However, KMA has still kept asking airlines to agree with another increase in the charge due to the low cost of goods recovery ratio of 7%. The air meteorological charge has changed from 2,210 KRW at the beginning to 11,400 KRW as of June 2018. According to ARIMA intervention time series analysis, it was proven national carriers would make a payment of 831 million KRW 2018 and 1,024 million KRW 2019, showing 186.2% and 123.2% increase compared to last year respectively. The total amount of charge for both national LCC and foreign airlines was aggregated up to 1,952 million KRW 2019, 227% bigger than the charge paid at 2017. Considering the 50% increase of consumer price index last decade, the increased charge would impair the global competitiveness of national carriers. It could be suggested that current air meteorological charge scheme be improved to apply overseas trend and for national carriers to have a competitive advantage in global aviation market.

Pricing Strategy for Access Charge of IPTV Network : A Dynamic Analysis (IPTV 망 임대의 가격책정 전략 : 동태적 분석)

  • Kim, Dong-Hee;Cha, Jeong-Hyun;Oh, Jung-Suk;Kim, Soo-Wook
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.35 no.3
    • /
    • pp.45-58
    • /
    • 2010
  • Due to rapid developments of IT technologies, convergence services like IPTV (Internet protocol television) are shown up. Even though expert and customer had great expectations for this innovative service, commercialization was delayed for years by the legal dispute between industry players. One of the biggest problems was that whether internet backbone providers have to share their internet network backbone with IPTV service providers (which don't have network backbone) or not. As other countries, Korean government set the rules that ISP have to offer indiscriminate access to other IPTV service provider. At the same time, internet backbone providers can charge access charge based on cost by way of compensation. Thus access charge is very critical to the IPTV industry players. The objective of this paper is to provide model that can calculate the reasonable access charge by system dynamics, based upon real data in Korean telecommunication industry.

Improved Memory Characteristics by NH3 Post Annealing for ZrO2 Based Charge Trapping Nonvolatile Memory

  • Tang, Zhenjie;Zhao, Dongqiu;Li, Rong;Zhu, Xinhua
    • Transactions on Electrical and Electronic Materials
    • /
    • v.15 no.1
    • /
    • pp.16-19
    • /
    • 2014
  • Charge trapping nonvolatile memory capacitors with $ZrO_2$ as charge trapping layer were fabricated, and the effects of post annealing atmosphere ($NH_3$ and $N_2$) on their memory storage characteristics were investigated. It was found that the memory windows were improved, after annealing treatment. The memory capacitor after $NH_3$ annealing treatment exhibited the best electrical characteristics, with a 6.8 V memory window, a lower charge loss ~22.3% up to ten years, even at $150^{\circ}C$, and excellent endurance (1.5% memory window degradation). The results are attributed to deep level bulk charge traps, induced by using $NH_3$ annealing.

A Case Study of Underwater Blasting (수중발파 사례 연구)

  • 정민수;박종호;송영석
    • Explosives and Blasting
    • /
    • v.22 no.3
    • /
    • pp.57-64
    • /
    • 2004
  • There are two major types of underwater blasting at Korea, bridges and harbor construction work. Pier blasting for lay the foundation bridges construction is used dry excavation working (drilling and charging) after pump out water and then fire pump in water that is same as bench blasting. In contrast, underwater blasting for harbor construction and increase of harbor load depth is used to barge with digging equipment that is in oder to drilling on the surface and blasting work(charge, hook-up) under water. Thus, there are need to special concern such as charge method and hook-up method different from tunnel blasting work and bench blasting work. If do not use special concern breaks out dead pressure and mis fire because of there are so many difficult condition such as water pressure, obstruct field of vision. In this study underwater blasting at Busan Harbor Construction have consider with special concern that is plastic pipe charge method used to MegaMITE I and specialized buoy hook- up method make far initial system detonate on the surface used to TLD. The results is designed blast pattern charge per delay effect an inspection of verify between predict velocity and measure velocity. minimized break out mis fire consideration charge method, hook up method. According to result best underwater blasting design is 105mm drilling dia, MeGAMITE II, HiNLL Plus(non electric detonator).

Effects of Pre-Formed Space Charge by Negative DC Voltage on Partial Discharge Patterns of XLPE (부극성 직류전압에 의해 형성된 공간전하가 XLPE의 부분방전패턴에 미치는 영향)

  • HwangBo, Seung;Lee, June-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1653-1655
    • /
    • 2003
  • The purpose of this paper is to evaluate the effects of pre-formed space charge by negative DC voltage on partial discharge(PD) patterns of XLPE. We have suggested a modified pulsed electro-acoustic method and demonstrated that the PD patterns are strongly influenced by the pre-formed space charge distributions, which are hardly disappeared up to AC 8kV in electrode configuration including air gap between XLPE layer and electrode.

  • PDF

High Step-Up Converter with Hybrid Structure Based on One Switch

  • Hwu, K.I.;Peng, T.J.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1566-1577
    • /
    • 2015
  • A novel high step-up converter is presented herein, which combines the conventional buck-boost converter, the charge pump capacitor and the coupling inductor. By doing so, a quite high voltage conversion ratio due to not only the turns ratio but also the duty cycle, so as to increase design feasibility. It is noted that the denominator of the voltage conversion ratio is the square of one minus duty cycle. Above all, there is no voltage spike across the switch due to the leakage inductance and hence no passive or active snubber is needed, and furthermore, the used switch is driven without isolation and hence the gate driving circuit is relatively simple, thereby upgrading the industrial application capability of this converter. In this paper, the basic operating principles and the associated mathematical deductions are firstly described in detail, and finally some experimental results are provided to demonstrate the effectiveness of the proposed high step-up converter.