• Title/Summary/Keyword: Charge-to-mass ratio

Search Result 58, Processing Time 0.027 seconds

The Improvement of the Ionization on Micro Mass Spectrometer using Carbon Nanotube Emitter (탄소나노튜브 방출원을 통한 초소형 질량분석기의 이온화 향상)

  • Song, S.H.;Han, Kyu-Sung;Hong, Nguyen Tuan;Lee, S.I.;Yang, Sang-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.5
    • /
    • pp.1004-1009
    • /
    • 2009
  • Recently, mass spectrometers are widely used for in-situ chemical analysis. It has rapid response and high sensitivity. In this paper, we present the fabrication and test of a cold cathode emitter for micro mass spectrometer using CNTs(Carbon nano tubes). The CNTs have good mechanical, electrical and chemical characteristics. So they have a long life time and strong robustness. The micro mass spectrometer is composed of the glass substrate and the silicon substrate. The glass substrate is constructed by electrodes for TOF(Time-of-flight) which analyze an ion with mass to charge ratio as ion separator. The silicon substrate is highly doped wafer which is patterned for gate electrode and then 100 11m dry etching to grow the CNTs as the electron emitter. The CNTs are grown by HFCVD(Hot filament chemical vapor deposition) with sputtering the catalyst. We successfully attained to grow the CNTs and to test the characteristics.

An Experimental Study on the Effect of Mixture Distribution in the Constant Volume Combustion Chamber on the Combustion Characteristics (정적 연소실내 혼합기 분포가 연소특성에 미치는 영향에 관한 실험적 연구)

  • 이기형;이창희;안용흠
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.3
    • /
    • pp.10-18
    • /
    • 2004
  • It is well known that the stratified charge combustion has many kind of advantages to combustion characteristics, such as higher thermal efficiency and less CO, NOx levels than conventional homogeneous mixture combustion. Although this combustion can be caused low fuel consumption, it is produced the high unburned hydrocarbon and soot levels because of different equivalence ratio in the combustion chamber. Moreover it has a lot of possibility of low output and misfire if the mixture gas would not be in existence around the spark plug. In this paper, fundamental studies for stratified combustion were carried out using a constant volume combustion chamber. The effect of locally mixture gas distribution according to control the direct injection and premixed injection in the chamber were examined experimentally. In addition, the effects of turbulence on stratified charge combustion process were observed by schlieren photography.

Fabrication of Ceramic-based Graphene Membrane (CbGM) and Its Mass Transport Behavior for Water Treatment (수처리용 세라믹 기반 그래핀 맴브레인의 합성 및 물질이동특성)

  • Kim, Chang-Min;Park, Ki-Bum;Kim, Kwang-Soo;Kim, In S.
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.11
    • /
    • pp.649-655
    • /
    • 2015
  • As a novel water treatment membrane, concept of ceramic-based graphene membrane (CbGM) was suggested, and its mass transport behavior was investigated. The selectivity of CbGM was given by graphene material which is consisting of active layer, only transmitting water, but rejecting salts. Filtration-assisted assembly methods was employed as a facile method to fabricate CbGM. Surface morphology and characteristics of CbGM were analyzed by scanning electron microscopy (SEM) and contact angle. In addition, three different kinds of solutes (i.e., NaCl, $MgCl_2$, $Na_2SO_4$) were tested in batch forward osmosis system to confirm the mass transport behavior. Through surface morphology analysis and mass transport behavior, it was revealed that interlocking between graphene layers is very important, rather than thickness of laminated graphene layers, in terms of selectivity to CbGM. All the anions in each solute showed faster transport than those of cations. In addition, solutes which have high ion valence charge ratio of anion to cation ($Z^-/Z^+$) was easier to be passed through CbGM. It indirectly implied that the surface charge of CbGM appear to be positive. In addition, It showed that surface charge of CbGM has a great role on mass transport, in particular, transport of matter having charges, generally ions.

Influence of Working Fluids to Heat Transfer Characteristics of the Heat Exchanger using Oscillating Capillary Tube Heat Pipe for Low Temperature Waste Heat Recovery (저온 폐열회수용 진동세관형 히트파이프 열교환기의 작동 유체에 따른 열전달 특성)

  • 이욱현;임용빈;김정훈;김종수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.7
    • /
    • pp.659-666
    • /
    • 2000
  • Heat transfer characteristics of a heat exchanger for low temperature waste heat recovery using oscillating capillary tube heat pipe were evaluated against the charge ratio variation of working fluid and various working fluids. R-l42b, R-22 and R-290 were used as working fluids. The heat exchanger was composed of heat pipe with capillary tube bundles, having a 2.6mm in outer diameter, 1.4mm in inner diameter with 101m long, and 40 turns. Charge ratio of working fluid was 40% and 50%. Water was used as secondary fluid. Inlet temperature and mass velocity for each secondary fluid were 297 K, 280 K and9~27 kg /$m^2s$,, respectively. From experimental results, it was found that heat transfer performance of R-22 was higher than those of R-l42b and R-290 and it was proportional to Figure of merit for thermosyphons. As a result, it was thought that R-22 was the most suitable working fluid of waste heat recovery for low temperature waste heat recovery.

  • PDF

Application of multimodal surfaces using amorphous silicon (a-Si) thin film for secondary ion mass spectrometry (SIMS) and laser desorption/ionization mass spectrometry (LDI-MS)

  • Kim, Shin Hye;Lee, Tae Geol;Yoon, Sohee
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.384.1-384.1
    • /
    • 2016
  • We reported that amorphous silicon (a-Si) thin film provide sample plate exhibiting a multimodality to measure biomolecules by secondary ion mass spectrometry (SIMS) and laser desorption/ionization mass spectrometry (LDI-MS). Kim et al.1 reported that a-Si thin film were suitable to detect small molecules such as drugs and peptides by SIMS and LDI-MS. Recently, bacterial identification has been required in many fields such as food analysis, veterinary science, ecology, agriculture, and so on.2 Mass spectrometry is emerging for identifying and profiling microbiology samples from its advantageous characters of label-free and shot-time analysis. Five species of bacteria - S. aureus, G. glutamicum, B. kurstaki, B. sphaericus, and B. licheniformis - were sampled for MS analysis without lipid extraction in sample preparation steps. The samples were loaded onto the a-Si thin film with a thickness of 100 nm which did not only considered laser-beam penetration but also surface homogeneity. Mass spectra were recorded in both positive and negative ionization modes for more analytical information. High reproducibility and sensitivity of mass spectra were demonstrated in a mass range up to mass-to-charge ratio(m/z) 1200 by applying the a-Si thin film in mentioned above MS. Principle component analysis (PCA) - a popular statistical analysis widely used in data processing was employed to differentiate between five bacterial species. The PCA results verified that each bacterial species were readily distinguished and differentiated effectively from our MS approach. It shows a new opportunity to rapid bacterial profiling and identification in clinical microbiology. More details will be discussed in the presentation.

  • PDF

An Analytic Study on Laminar Film Condensation along the Interior Surface of a Cave-Shaped Cavity of a Flat Plate Heat Pipe

  • Lee, Jin-Sung;Kim, Tae-Gyu;Park, Tae-Sang;Kim, Choong-Sik
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.7
    • /
    • pp.966-974
    • /
    • 2002
  • An analytic approach has been employed to study condensate film thickness distribution inside cave-shaped cavity of a flat plate heat pipe. The results indicate that the condensate film thickness largely depends on mass flow rate and local velocity of condensate. The increasing rate of condensate film for circular region reveals about 50% higher value than that of vertical region. The physical properties of working fluid affect significantly the condensate film thickness, such as the condensate film thickness for the case of FC-40 are 5 times larger than that of water. In comparison with condensation on a vertical wall, the average heat transfer coefficient in the cave-shaped cavity presented 10∼15% lower values due to the fact that the average film thickness formed inside the cave-shaped cavity was larger than that of the vertical wall with an equivalent flow length. A correlation formula which is based on the condensate film analysis for the cave-shaped cavity to predict average heat transfer coefficient is presented. Also, the critical minimum fill charge ratio of working fluid based on condensate film analysis has been predicted, and the minimum fill charge ratios for FC-40 and water are about Ψ$\_$crit/=3∼7%, Ψ$\_$crit/=0.5∼1.3% respectively, in the range of heat flux q"=5∼90kW/㎡.

Isotope Measurement of Uranium at Ultratrace Levels Using Multicollector Inductively Coupled Plasma Mass Spectrometry

  • Oh, Seong-Y.;Lee, Seon-A.;Park, Jong-Ho;Lee, Myung-Ho;Song, Kyu-Seok
    • Mass Spectrometry Letters
    • /
    • v.3 no.2
    • /
    • pp.54-57
    • /
    • 2012
  • Mass spectrometric analysis was carried out using multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS) for the precise and accurate determination of the isotope ratios of ultratrace levels of uranium dissolved in 3% $HNO_3$. We used the certified reference material (CRM) 112-A at a trace level of 100 pg/mL for the uranium isotopic measurement. Multiple collectors were utilized for the simultaneous measurement of uranium isotopes to reduce the signal uncertainty due to variations in the ion beam intensity over time. Mass bias correction was applied to the measured U isotopes to improve the precision and accuracy. Furthermore, elemental standard solution with certified values of platinum, iridium, gold, and thallium dissolved in 3% $HNO_3$ were analyzed to investigate the formation rates of the polyatomic ions of $Ir^{40}$ $Ar^+$, $Pt^{40}$ $Ar^+$, $Tl^{40}$ $Ar^+$, $Au^{40}$ $Ar^+$ for the concentration range of 50-400 pg/mL. Those polyatomic ions have mass-to-charge ratios in the 230-245 m/z region that it would contribute to the increase of background intensity of uranium, thorium, plutonium, and americium isotopes. The effect of the polyatomic ion interference on uranium isotope measurement has been estimated.

2009 KSTAR ICRF 방전세정 플라즈마의 불순물 제거 특성

  • Kim, Seon-Ho;Wang, Seon-Jeong;Gwak, Jong-Gu;Kim, Seong-Gyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.296-296
    • /
    • 2010
  • ICRF 시스템을 이용한 방전세정인 ICWC(Ion Cyclotron Wall Cleaning)는 ITER와 DEMO 같은 초전도 자석을 이용하는 토카막에서 토카막 shot 중간에 자장을 낮추지 않고 바로 방전 세정을 할 수 있는 방법이다. 토카막에서 방전세정은 탄소나 산소 화합물과 같은 불순물을 제거하여 방사에 의한 플라즈마 냉각을 막고 토카막 초기 start-up시 진공 챔버 벽면으로부터 의도하지 않은 연료주입을 제거하는 역할을 한다. 본 연구에서는 ICWC 방전 세정 최적화를 위해 플라즈마의 불순물 제거 특성을 수소 유량의 크기와 ICRF 펄스의 duty ratio를 바꿔가면서 관찰하였다. ICRF 전력은 44.2 MHz에서 20-50 kW 가 입사되었으며 자장은 3 T에서 고정되었다. 운전압력은 $10^{-4}$ mbar 정도이다. 헬륨의 유량을 400 sccm으로 고정한 후 수소의 유량을 40 sccm에서 160 sccm까지 증가시켜가면서 제거율을 관측하였다. 그 결과 수소 유량의 증가에 따라 제거율이 증가하는 불순물과 오히려 감소하는 불순물이 있음이 관측되었다. 제거율이 증가되는 불순물 group은 charge-to-mass ratio가 26, 28, 40, 44이고 감소하는 불순물 group은 18, 20, 32 이다. 펄스의 duty ratio를 1/9(on/off) 초에서 5/5(on/off) 초로 증가시킴에 따라 제거율이 증가하는 불순물과 감소하는 불순물이 또한 나타났는데 수소 유량 실험과 그 group에 차이가 없었다. 이러한 실험결과는 수소 유량의 증가나 펄스 길이의 증가에 따라 가스의 종류에 관계없이 모두 증가하거나 감소할 것이라는 예측과는 다른 결과로서 이것에 대한 명료한 해석이 필요하다. 왜냐하면 위와 같은 운전조건에서 효율적인 불순물 제거를 위해서는 불순물 제거 운전 방법이 불순물의 종류에 따라 모두 달라져야 하기 때문이다. 본 연구에서는 이러한 특성을 불순물의 dissociation 에너지 관점에서 해석을 시도하였다.

  • PDF

A Study on the Work Process Analysis of Korean Apparel Exporters (의류수출업체의 업무과정 분석에 관한 연구)

  • Moon, Jiyeon;Kim, Sora
    • Journal of Fashion Business
    • /
    • v.19 no.4
    • /
    • pp.183-199
    • /
    • 2015
  • This study aimed to systematize the apparel vendor work processes and provide useful information to future employees of clothing export units by analyzing the processes of vendors' manufacturing tasks. A survey of 20 apparel vendors servicing mainly U.S. buyers was conducted on employees of overseas business departments working for more than five years. buyers. Based on the results, vendors mainly manufactured cut-and-sew knit products. Regarding the production method, OEM was used more frequently than ODM. Fourteen (70%) companies used the ODM method. This suggests that vendors are expanding their production method from OEM to ODM. In order to summarize the work of each business based on the clothing production process research results, buyers were in charge of planning products and the vendors were in charge of sampling. Production of materials and the approval of material tests were out sourced. Overseas factories of vendors were in charge of bulk (mass) production and garment finishing, as well as packaging and shipping the completed products. Even though the vendors' head offices do not directly produce clothes, they play a pivotal role in ensuring planning and management progress in clothing production. As buyers prefer direct contracts for cost reduction, the vendor additionally performs the role of an agent. Also, with the increase in ODM production ratio, the work area of the vendor is expanding. If Korean clothing exporters improve their global competitiveness by investing in the R&D of materials and design to enhance the ODM method, the development of Korea's clothing and export industry will benefit significantly.

New Fabrication Approach for Low Voltage Driving Electrophoretic Display

  • Park, Young-Mi;Kim, Do-Yun;Cho, Young-Tae;Lee, Yong-Eui;Kim, Chul-Hwan;Yoon, Sang-Soo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.893-895
    • /
    • 2009
  • In this paper, we described the unique and novel method to prepare two kinds of electro-active particles, black and white particles with different polarity. The surface of the particles was characterized to be uniform and clean by adopting spray dryer as a tool for genesis of particles; neither surfactants nor high dielectric medium like water was employed during particle preparation step. The other purpose of this study is to investigate the factors that contribute high driving voltage of particlebased display like QR-LPD. We extracted parameters interaction between particle and electrode, and between oppositely charged particles. Here we reported an excellent behavior of particle-based display that showed low operating voltage, high contrast ratio as high as 8:1 without scarification of quick response time. By optimizing the particle size, charge per mass, selection of external additive sets, a lower driving voltage as low as 40V for the particles with $10{\mu}m$ volume average diameter was obtained.

  • PDF