• Title/Summary/Keyword: Charge extraction

Search Result 91, Processing Time 0.025 seconds

Efficient Signal Integrity Verification in Complicated Multi-Layer VLSI Interconnects (복잡한 다층 VLSI 배선구조에서의 효율적인 신호 무결성 검증 방법)

  • Jin, U-Jin;Eo, Yun-Seon;Sim, Jong-In
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.3
    • /
    • pp.73-84
    • /
    • 2002
  • Fast and accurate new capacitance determination methodology for non-uniform complicated multi-layer VLSI interconnects is presented. Since a capacitance determination of intricate multi-layer interconnects using 3-dimensional field-solver is not practical, quasi-3-dimensional methodology is presented. Interconnects with discontinuity (i.e., bend structure and different spacing between lines, etc.) are partitioned. Then, each partial capacitance of divided parts is extracted by using 2-dimensional extraction methodology. For a multi-layer interconnects with shielding layer, the system can be simplified by investigating a distribution of charge in it. Thereby, quasi-3-dimensional capacitance for multi-layer interconnects can be determined by combining solid-ground based 2-dimensional capacitance and shielding effect which is independently determined with layout dimensions. This methodology for complicated multi-layer interconnects is more accurate and cost-efficient than conventional 3-dimensional methodology It is shown that the quasi-3-dimensional capacitance methodology has excellent agreement with 3-dimensional field- solver-based results within 5% error.

An Efficient Matrix-Vector Product Algorithm for the Analysis of General Interconnect Structures (일반적인 연결선 구조의 해석을 위한 효율적인 행렬-벡터 곱 알고리즘)

  • Jung, Seung-Ho;Baek, Jong-Humn;Kim, Joon-Hee;Kim, Seok-Yoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.12
    • /
    • pp.56-65
    • /
    • 2001
  • This paper proposes an algorithm for the capacitance extraction of general 3-dimensional conductors in an ideal uniform dielectric that uses a high-order quadrature approximation method combined with the typical first-order collocation method to enhance the accuracy and adopts an efficient matrix-vector product algorithm for the model-order reduction to achieve efficiency. The proposed method enhances the accuracy using the quadrature method for interconnects containing corners and vias that concentrate the charge density. It also achieves the efficiency by reducing the model order using the fact that large parts of system matrices are of numerically low rank. This technique combines an SVD-based algorithm for the compression of rank-deficient matrices and Gram-Schmidt algorithm of a Krylov-subspace iterative technique for the rapid multiplication of matrices. It is shown through the performance evaluation procedure that the combination of these two techniques leads to a more efficient algorithm than Gaussian elimination or other standard iterative schemes within a given error tolerance.

  • PDF

Application of multimodal surfaces using amorphous silicon (a-Si) thin film for secondary ion mass spectrometry (SIMS) and laser desorption/ionization mass spectrometry (LDI-MS)

  • Kim, Shin Hye;Lee, Tae Geol;Yoon, Sohee
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.384.1-384.1
    • /
    • 2016
  • We reported that amorphous silicon (a-Si) thin film provide sample plate exhibiting a multimodality to measure biomolecules by secondary ion mass spectrometry (SIMS) and laser desorption/ionization mass spectrometry (LDI-MS). Kim et al.1 reported that a-Si thin film were suitable to detect small molecules such as drugs and peptides by SIMS and LDI-MS. Recently, bacterial identification has been required in many fields such as food analysis, veterinary science, ecology, agriculture, and so on.2 Mass spectrometry is emerging for identifying and profiling microbiology samples from its advantageous characters of label-free and shot-time analysis. Five species of bacteria - S. aureus, G. glutamicum, B. kurstaki, B. sphaericus, and B. licheniformis - were sampled for MS analysis without lipid extraction in sample preparation steps. The samples were loaded onto the a-Si thin film with a thickness of 100 nm which did not only considered laser-beam penetration but also surface homogeneity. Mass spectra were recorded in both positive and negative ionization modes for more analytical information. High reproducibility and sensitivity of mass spectra were demonstrated in a mass range up to mass-to-charge ratio(m/z) 1200 by applying the a-Si thin film in mentioned above MS. Principle component analysis (PCA) - a popular statistical analysis widely used in data processing was employed to differentiate between five bacterial species. The PCA results verified that each bacterial species were readily distinguished and differentiated effectively from our MS approach. It shows a new opportunity to rapid bacterial profiling and identification in clinical microbiology. More details will be discussed in the presentation.

  • PDF

Removal of As, Cadmium and Lead in Sandy Soil with Sonification-Electrokinetic Remediation (초음파동전기기법을 이용한 비소, 카드뮴, 납으로 오염된 사질토 정화 연구)

  • Oh, SeungJin;Oh, Minah;Lee, Jai-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.7
    • /
    • pp.1-11
    • /
    • 2013
  • The actively soil pollution by the toxic heavy-metals like the arsenic, cadmium, lead due to the industrialization and economic activity. The uses the electrokinetic remediation of contaminated soil has many researches against the fine soil having a small size in the on going. However, it is the actual condition which the research result that is not effective due to the low surface charge of the particle and high permeability shows in the electrokinetic remediation in comparison with the fine soil in the case of the sandy soil in which the particle size is large. In this research, the electrokinetic remediation and ultrasonic wave fetch strategy is compound applied against the sandy soil polluted by the arsenic, cadmium, and lead removal efficiency of the sandy soil through the comparison with the existing electrokinetic remediation tries to be evaluated. First of all, desorption of contaminants in soil by ultrasonic extraction in the Pre-Test conducted to see desorption effective 5~15%. After that, By conducted Batch-Test results frequency output century 200 Khz, reaction time 30 min, contaminated soil used in experiment was 500 g. Removal efficiency of arsenic, cadmium, lead are 25.55%, 8.01%, 34.90%. But, As, Cd, Pb remediation efficiency less than 1% in EK1(control group).

Extracting Three-Dimensional Geometric Information of Roads from Integrated Multi-sensor Data using Ground Vehicle Borne System (지상 이동체 기반의 다중 센서 통합 데이터를 활용한 도로의 3차원 기하정보 추출에 관한 연구)

  • Kim, Moon-Gie;Sung, Jung-Gon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.11 no.3
    • /
    • pp.68-79
    • /
    • 2008
  • Ground vehicle borne system which is named RoSSAV(Road Safety Survey and Analysis Vehicle) developed in KICT(Korea Institute of Construction Technology) can collect road geometric data. This system therefore is able to evaluate the road safety and analyze road deficient sections using data collected along the roads. The purpose of this study is to extract road geometric data for 3D road modeling in dangerous road section and The system should be able to quickly provide more accurate data. Various sensors(circular laser scanner, GPS, INS, CCD camera and DMI) are installed in moving object and collect road environment data. Finally, We extract 3d road geometry(center, boundary), road facility and slope using integrated multi-sensor data.

  • PDF

Design and Implementation of the System for Automatic Classification of Blood Cell By Image Analysis (영상분석을 통한 혈구자동분류 시스템의 설계 및 구현)

  • Kim, Kyung-Su;Kim, Pan-Koo
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.36C no.12
    • /
    • pp.90-97
    • /
    • 1999
  • Recently, there have been many researches to automate processing and analysing image data in medical field, due to the advance of image processing techniques, the fast communication network and high performance hardware. In this paper, we design and implement the system based on the multi-layer neural network model to be able to analyze, differentiate and count blood cells in the peripheral blood image. To do these, we segment red and white-blood cell in blood image acquired from microscope with CCD(Charge-coupled device) camera and then apply the various feature extraction algorithms to classify. In addition to, we reduce multi-variate feature number using PCA(Principle Component Analysis) to construct more efficient classifier. So, in this paper, we are sure that the proposed system can be applied to a pathological guided system.

  • PDF

The Research on Aluminum and Silcon Nanoparticles as Anode Materials for Lithium Ion Batteries (알루미늄 실리콘 나노분말을 이용한 리튬이온전지 음극재료에 관한 연구)

  • Kim, Hyeong-Jo;Tulugan, Kelimu;Kim, Hyung-Jin;Park, Won-Jo
    • Journal of Power System Engineering
    • /
    • v.17 no.1
    • /
    • pp.110-115
    • /
    • 2013
  • The electrochemical performance and microstructure of Al-Si, Al-Si/C was investigated as anode for lithium ion battery. The Al-Si nano composite with 5 : 1 at% ratio was prepared by arc-discharge nano powder process. However, some of problem is occurred, when Al nano composite was synthesized by this manufacturing. The oxidation film is generated around Al-Si particles for passivating processing in the manufacture. The oxidation film interrupts electrical chemistry reaction during lithium ion insertion/extraction for charge and discharge. Because of the existence the oxidation film, Al-Si first cycle capacity is very lower than other examples. Therefore, carbon synthsized by glucose ($C_6H_{12}O_6$) was conducted to remove the oxidation film covered on the composite. The results showed that the first discharge cycle capacity of Al-Si/C is improved to 113mAh/g comparing with Al-Si (18.6mAh/g). Furthermore, XRD data and TEM images indicate that $Al_4C_3$ crystalline exist in Al-Si/C composite. In addition the Si-Al anode material, in which silicon is more contained was tested by same method as above, it was investigated to check the anode capacity and morphology properties in accordance with changing content of silicon, Si-Al anode has much higher initial discharge capacity(about 500mAh/g) than anode materials based on Aluminum as well as the morphology properties is also very different with the anode based Aluminum.

Fabrication and Characterization of Dye-sensitized Solar Cells based on Anodic Titanium Oxide Nanotube Arrays Sensitized with Heteroleptic Ruthenium Dyes

  • Shen, Chien-Hung;Chang, Yu-Cheng;Wu, Po-Ting;Diau, Eric Wei-Guang
    • Rapid Communication in Photoscience
    • /
    • v.3 no.1
    • /
    • pp.16-19
    • /
    • 2014
  • Anodic self-organized titania nanotube (TNT) arrays have a great potential as efficient electron-transport materials for dye-sensitized solar cells (DSSC). Herewith we report the photovoltaic and kinetic investigations for a series of heteroleptic ruthenium complexes (RD16-RD18) sensitized on TNT films for DSSC applications. We found that the RD16 device had an enhanced short-circuit current density ($J_{SC}/mAcm^{-2}=15.0$) and an efficiency of power conversion (${\eta}=7.2%$) greater than that of a N719 device (${\eta}=7.1%$) due to the increasing light-harvesting and the broadened spectral features with thiophene-based ligands. However, the device made of RD17 (adding one more hexyl chain) showed smaller $J_{SC}(14.1mAcm^{-2})$ and poorer ${\eta}(6.8%)$ compare to those of RD16 due to smaller amount of dye-loading and less efficient electron injection for the RD17 device than for the RD16 device. For the RD18 dye (adding one more thiophene unit and one more hexyl chain), we found that the device showed even lower $J_{SC}(13.2mAcm^{-2}) $ that led to a poorest device performance (${\eta}=6.2%$) for the RD18 device. These results are against to those obtained from the same dyes sensitized on $TiO_2$ nanoparticle films and they can be rationalized according to the electron transport kinetics measured using the methods of charge extraction and transient photovoltage decays.

Design of MMIC SPST Switches Using GaAs MESFETs (GaAs MESFET을 이용한 MMIC SPST 스위치 설계)

  • 이명규;윤경식;형창희;김해천;박철순
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.4C
    • /
    • pp.371-379
    • /
    • 2002
  • In this paper, the MMIC SPST switches operating from DC to 3GHz were designed and implemented. Prior to the design of switches, the small and large-signal switch models were needed to predict switch performance accurately. The newly proposed small-signal switch model parameters were extracted from measured S-parameters using optimization technique with estimated initial values and boundary limits. In the extraction of large-signal switch model parameters, the current source was modeled by fitting empirical equations to measured DC data and the charge model was derived from extracted channel capacitances from measured S-parameters varying the drain-source voltage. To design basic series-shunt SPST switches and isolation-improved SPST switches, we applied this model to commercial microwave circuit simulator. The improved SPST switches exhibited 0.302dB insertion loss, 35.762dB isolation, 1.249 input VSWR, 1.254 output VSWR, and about 15.7dBm PldB with 0/-3V control voltages at 3GHz.

Spectrophotometric Determination of Some Fluoroquinolone Antibacterials through Charge-transfer and Ion-pair Complexation Reactions

  • El-Brashy, Amina Mohamed;Metwally, Mohamed El-Sayed;El-Sepai, Fawzi Abdallah
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.3
    • /
    • pp.365-372
    • /
    • 2004
  • Two simple, rapid and sensitive spectrophotometric methods for the determination of three fluoroquinolones, namely levofloxacin, norfloxacin and ciprofloxacin have been performed either in pure form or in their tablets. In the first method, levofloxacin and norfloxacin are directly treated with bromocresol green (BCG) in dichloromethane while ciprofloxacin is allowed to react with the same dye in aqueous acidic buffer. Highly yellow colored complex species were formed instantaneously in case of levofloxacin and norfloxacin or after extraction into dichloromethane for ciprofloxacin. The formed complexes are quantified spectrophotometrically at their absorption maxima at 411 nm for levofloxacin and 412 nm for norfloxacin and ciprofloxacin. The second method involves the reaction of levofloxacin with ${\rho}$-chloranilic acid ( ${\rho}$-CA) and norfloxacin with tetracyanoethylene (TCNE) in acetonitrile to give complexes with maximum absorbance at 521 and 333 nm for the two drugs, respectively. Adopting the first procedure, calibration graphs were linear over the range 1- 20 ${\mu}g\;mL^{-1}$ with mean percentage recoveries of 100.41 ${\pm}$ 0.72, 99.99 ${\pm}$ 0.54 and 100.23 ${\pm}$ 0.91 for the theree drugs, respectively. For the second procedure, the concentration ranges were 15-250 ${\mu}g\;mL^{-1}$ for levofloxacin using ${\rho}$-CA and 0.8-16 ${\mu}g\;mL^{-1}$ for norfloxacin using TCNE with mean percentage recoveries of 99.88 ${\pm}$ 0.45 and 100.26 ${\pm}$ 0.68 for the two drugs, respectively. The proposed methods were successfully applied to determine these drugs in their tablet formulations and the results compared favorably to that of reference methods. The proposed methods are recommended for quality control and routine analysis.