• Title/Summary/Keyword: Charge coupled device (CCD)

Search Result 181, Processing Time 0.027 seconds

디지탈 화상처리를 이용한 사출제품의 길이측정용 시각검사시스템 개발에 관한 연구

  • 김재열;박환규;오보석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.281-285
    • /
    • 1996
  • In this paper, I made visual inspection system using Vision Board and it is consist of an illuminator (a fluorescent lamp), image input device(CCD(Charge)Coupled Device) camera), image processing system(Vision Board(FARAMVB-02), image output device(videomonitor, printer), a measuring instrument(TELMN1000). Length measurement by visual inspection system is used 100mm gauge block instead of calculating distance between camera and object, it measured horizontal and vertical length factor from 400mm to 650mm by increasing 50mm. In this place, measured horizontal and vertical length factor made use of length measurement of a injection. A measuring instrument used to compare a measured length of a injection visual inspection system with it. In conclusion, length measurement of a injection compared a measuring instrument withvisual inspecion system using length factor of 100mm guage block. Maximum error of length compared two devices a measuring instrument with visual inspection system is 0.55mm. And operation program is made up Borland C++ 3.1. By changing, it is applied to various uses.

  • PDF

Camera Position Estimation in Gaster Using Electroendoscopic Image Sequence (전자내시경 순차영상을 이용한 위에서의 카메라 위치 추정)

  • Lee, Sang-Kyoung;Min, Byoung-Goo
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1990 no.11
    • /
    • pp.33-37
    • /
    • 1990
  • Endoscope system is the device that observe interior the body. It has some demerits because it use of optical fibers. The resolution of images depends on the number of optical fibers, it is impossible that several people observe at the same time and it needs special camera in order to record images. In order to overcome these demerits, electro endoscope system using CCD(Charge Coupled Device) has been developed recently. If the diameter of insertion tube is thinner, it is easier to be examined by thin endoscope system. At the present time, we develope these type of electro endoscope system in the department of SNU biomedical engineering. Moreover, we are researching an algorithm of the 3D-reconstruction of interior of the gaster. In this paper, a method for 3D information detection using electroendoscopic image sequence has been presented.

  • PDF

Technical Trend of High Speed Camera (고속 카메라 기술 동향)

  • Park, Doo-Jin;Noh, Young-Hwan;Kim, Tae-Hyung;Lee, Hyo-Keun
    • Current Industrial and Technological Trends in Aerospace
    • /
    • v.6 no.2
    • /
    • pp.125-132
    • /
    • 2008
  • High speed camera is very important and essential device to analyze the motion of fast moving object in detail. This paper describes the basic concepts of the high speed film camera and high speed digital camera and the history and future technical trends in high speed camera industry. In addition, application field of high speed camera in Korea as well as other countries and future plan to use high speed camera in Naro Space Center has been descried.

  • PDF

Measurement of Static and Dynamic Displacement by Image Processing and Study for Prediction Method of Velocity and Acceleration (영상처리를 이용한 정적·동적 변위 계측과 속도·가속도 추산방식 연구)

  • Heo, Seok;Lee, Bum-Ho;Jang, Il-Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.2
    • /
    • pp.112-119
    • /
    • 2011
  • This paper is concerned with the measurement of static and dynamic displacement by image processing(IP) and study for prediction method of velocity and acceleration. To measure the displacement visually, the measurement system consists of a telephoto zoom camera, CCD(charge coupled device) image device and a computer. The specific target on the white board is used to calculate the displacement of the structure. The captured image is then converted into a pixel-based data and then analyzed numerically. The limitation of the system depends on the image capturing speed and the pixel-size of image. In this paper, we developed for the displacement measurement using the image processing method. The proposed method enables us to measure the vibration displacement, velocity and acceleration directly without any contact. The current resolution for the displacement measurement can be seen from the results.

Calibration Method of Plenoptic Camera using CCD Camera Model (CCD 카메라 모델을 이용한 플렌옵틱 카메라의 캘리브레이션 방법)

  • Kim, Song-Ran;Jeong, Min-Chang;Kang, Hyun-Soo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.2
    • /
    • pp.261-269
    • /
    • 2018
  • This paper presents a convenient method to estimate the internal parameters of plenoptic camera using CCD(charge-coupled device) camera model. The images used for plenoptic camera calibration generally use the checkerboard pattern used in CCD camera calibration. Based on the CCD camera model, the determinant of the plenoptic camera model can be derived through the relationship with the plenoptic camera model. We formulate four equations that express the focal length, the principal point, the baseline, and distance between the virtual camera and the object. By performing a nonlinear optimization technique, we solve the equations to estimate the parameters. We compare the estimation results with the actual parameters and evaluate the reprojection error. Experimental results show that the MSE(mean square error) is 0.309 and estimation values are very close to actual values.

Evaluation for Geometric Calibration Accuracy of Zoom-lens CCD Camera (줌렌즈 CCD 카메라의 기하학적 검정 정확도 평가)

  • 유환희;정상용;김성삼
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.21 no.3
    • /
    • pp.245-254
    • /
    • 2003
  • Zoom lenses CCD(Charge Coupled Device) cameras have many desirable features but appear to be geometrically unstable and diffcult to calibrate. It is well blown that the zooming camera parameters change with zoom lens position. This paper presents a comparative study of two approaches, namely, DLT(Direct Linear Transformation) introduced by Abdel-Aziz and Karara and the model proposed by Tsai, to evaluate the camera parameters of zoom lenses CCD camera and 3D positioning accuracy. As a result, the accuracy for 3D positioning using Tsai and DLT model is similar in both methods when the set of GCPs and the object are arranged in the same space. However, Tsai model is more stable than DLT in the case that the object is apart from the set of GCPs. Also, the further study for the parameters optimization of conventional DLT is needed to improve accuracy for 3D positioning.

Development of a Period Analysis Algorithm for Detecting Variable Stars in Time-Series Observational Data

  • Kim, Dong-Heun;Kim, Yonggi;Yoon, Joh-Na;Im, Hong-Seo
    • Journal of Astronomy and Space Sciences
    • /
    • v.36 no.4
    • /
    • pp.283-292
    • /
    • 2019
  • The purpose of this study was to develop a period analysis algorithm for detecting new variable stars in the time-series data observed by charge coupled device (CCD). We used the data from a variable star monitoring program of the CBNUO. The R filter data of some magnetic cataclysmic variables observed for more than 20 days were chosen to achieve good statistical results. World Coordinate System (WCS) Tools was used to correct the rotation of the observed images and assign the same IDs to the stars included in the analyzed areas. The developed algorithm was applied to the data of DO Dra, TT Ari, RXSJ1803, and MU Cam. In these fields, we found 13 variable stars, five of which were new variable stars not previously reported. Our period analysis algorithm were tested in the case of observation data mixed with various fields of view because the observations were carried with 2K CCD as well as 4K CCD at the CBNUO. Our results show that variable stars can be detected using our algorithm even with observational data for which the field of view has changed. Our algorithm is useful to detect new variable stars and analyze them based on existing time-series data. The developed algorithm can play an important role as a recycling technique for used data

A Method for Quantitative Measurement of Lateral Flow Immunoassay Using Color Camera (컬러 카메라를 이용한 측면유동 면역 어세이 정량분석 방법)

  • Park, Jongwon
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.1
    • /
    • pp.1-7
    • /
    • 2014
  • Among semi-quantitative or fully quantitative lateral flow assay readers, an image sensor-based instrument has been widely used because of its simple setup, cheap sensor price, and compact equipment size. For all previous approaches, monochrome CCD or CMOS cameras were used for lateral flow assay imaging in which the overall intensities of all colors were taken into consideration to estimate the analyte content, although the analyte related color information is only limited to a narrow wavelength range. In the present work, we introduced a color CCD camera as a sensor and a color decomposition method to improve the sensitivity of the quantitative biosensor system which utilizes the lateral flow assay successfully. The proposed setup and image processing method were applied to achieve the quantification of imitatively dispensed particles on the surface of a porous membrane first, and the measurement result was then compared with that using a monochrome CCD. The compensation method was proposed in different illumination conditions. Eventually, the color decomposition method was introduced to the commercially available lateral flow immunochromatographic assay for the diagnosis of myocardial infarction. The measurement sensitivity utilizing the color image sensor is significantly improved since the slopes of the linear curve fit are enhanced from 0.0026 to 0.0040 and from 0.0802 to 0.1141 for myoglobin and creatine kinase (CK)-MB detection, respectively.

Automatic Color Recognition System for Stockigt Sizing Test (I) - Bias of Stockigt sizing test based on observer's subjectiveness - (스테키히트 시험용 자동 발색 인지 시스템 개발을 위한 기초연구(I) - Stockigt 사이즈도 시험법에 영향을 주는 요인 분석 -)

  • 김재옥;김철환;박종열
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.36 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • One of the most frequently used method for measurement of the degree of sizing (viz., hydrophobicity) is the Stockigt test. However, the Stockigt test was influenced by various factors such as dropping height, dropping amount, dropping speed and viewing angle. The resultant data of the sizing degree on the same specimen also varied according to different testers. Thus, the Stockigt test should be modified to be regarded as a highly reliable and reproducible standard method. For modifying the Stockigt test, it was required to quantify red coloration by reaction between 1% ferric chloride and 2% ammonium thiocyante during Stockigt testing. The cameras capturing the serial images during the red coloration process were the CMOS (Complementary Metal Oxide Semiconductor)-type and CCD (Charge Coupled Device)-type cameras. For measurement based on KS M 7025, the CCD-type camera must be used due to its high resolution, and on the other hand, for measurement based on Tappi Useful Method 429, the CMOS-type camera may be used owing to its low resolution. It was needed to covert the RGB values of a droplet image into HSV(Hue, Saturation, and Value) values because the human eyes are much closer to HSV than RGB. Among HSV values, the Hue value was accepted as the most reliable index consistent with the red coloration process by excluding the surrounding conditions such as light, tester's movement etc.

Motion of Conductive Spherical Particle under Uniform Electric Field (평등전계에서 도전성 구형 입자의 운동)

  • Lim, Hun-Chan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.8
    • /
    • pp.39-47
    • /
    • 2011
  • The motion of a conductive spherical particle under uniform electric field is investigated in order to find a suitable method for removing the conducting solid impurities contained in liquid plastic. When the positive dc voltage applied to the upper electrode, the vertical up-and-down motion of a charged particle by electrostatic force is observed by a charge-coupled device (CCD) camera or a high-speed video camera. The experimental data of the static threshold voltage by which the particle starts to move toward the counter electrode in air or silicone oil are in good agreement with theoretical value. When the applied voltage is larger than the static threshold voltage, the particle motion pattern in silicone oil consists of four stages: upward motion, stopping at the upper electrode, downward motion and stopping at the lower electrode. The stopping motion on the electrode is thought to be caused by the liquid flow accompanied by the particle motion. The particle charge calculated by integrating the pulse current, which is generated by the charge exchange between the electrode and the particle, is approximately 0.1~0.25 times of the theoretical value. This study is expected to help understand the electric properties of microparticles in oil circuit breaker (OCB) and oil transformer and improve their performance and longevity.