• Title/Summary/Keyword: Charge balance condition

Search Result 17, Processing Time 0.023 seconds

Characterization of Groundwater Chemistry and Fluoride in Groundwater Quality Monitoring Network of Korea

  • Han, Jiwon
    • Journal of the Korean earth science society
    • /
    • v.42 no.5
    • /
    • pp.556-570
    • /
    • 2021
  • This study presents the data analysis results of groundwater chemistry and the occurrence of fluoride in groundwater obtained from the groundwater quality monitoring network of Korea. The groundwater data were collected from the National Groundwater Information Center and censored for erratic values and charge balance (±10%). From the geochemical graphs and various ionic ratios, it was observed that the Ca-HCO3 type was predominant in Korean groundwater. In addition, water-rock interaction was identified as a key chemical process controlling groundwater chemistry, while precipitation and evaporation were found to be less important. According to a non-parametric trend test, at p=0.05, the concentration of fluoride in groundwater did not increase significantly and only 4.3% of the total groundwater exceeded the Korean drinking water standard of 1.5 mg/L. However, student t-tests revealed that the fluoride concentrations were closely associated with the lithologies of tuff, granite porphyry, and metamorphic rocks showing distinctively high levels. This study enhances our understanding of groundwater chemical composition and major controlling factors of fluoride occurrence and distribution in Korean groundwater.

Bi-Directional Buck-Boost Forward Converter for Photovoltaic Module type Power Conditioning System (태양광 모듈형 전력조절기를 위한 양방향 벅-부스트 포워드 컨버터)

  • Kim, Kyoung-Tak;Jeon, Young-Tae;Park, Joung-Hu
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.4
    • /
    • pp.335-342
    • /
    • 2016
  • This paper proposes an energy storage-assisted, series-connected module-integrated power conversion system that integrates a photovoltaic power conditioner and a charge balancing circuit. In conventional methods, a photovoltaic power conditioner and a cell-balancing circuit are needed for photovoltaic systems with energy storage devices, but they cause a complex configuration and high cost. Moreover, an imbalanced output voltage of the module-integrated converter for PV panels can be a result of partial shading. Partial shading can lead to the fault condition of the boost converter in shaded modules and high voltage stresses on the devices in other modules. To overcome these problems, a bidirectional buck-boost converter with an integrated magnetic device operating for a charge-balancing circuit is proposed. The proposed circuit has multiple secondary rectifiers with inductors sharing a single magnetic core, which works as an inductor for the main bidirectional charger/discharger of the energy storage. The secondary rectifiers operate as a cell-balancing circuit for both energy storage and the series-connected multiple outputs of the module-integrated converter. The operating principle of the cell-balancing power conversion circuit and the power stage design are presented and validated by PSIM simulation for analysis. A hardware prototype with equivalent photovoltaic modules is implemented for verification. The results verify that the modularized photovoltaic power conversion system in the output series with an energy storage successfully works with the proposed low-cost bidirectional buck-boost converter comprising a single magnetic device.

A Comparative Study on the Electrostatic Eliminator of Piezo Type Ionizer and Pulse AC Corona Type Ionizer (피에조를 이용한 코로나 방전과 펄스교류 코로나 방전을 이용한 정전기 제거장치의 비교 연구)

  • Kwon, Sung-Yul;Lee, Dong-Hoon;Choi, Jae-Wook
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.6
    • /
    • pp.50-54
    • /
    • 2009
  • Ionizer is used for improving manufacturing process and reducing inferior goods in the clean room. As a general rule, neutralization of the electrostatic charge is most important to make TFT-LCD, PDP and OLED. Pulse AC-static eliminator with output voltage of about 10.5kV has been used these days as neutralization device. But this device has a problem with lower performance which was caused by particles-adhesion on the electrode when it has been used for a long time. So we studied to solve the problem with lower performance using high Frequency(72kHz) static eliminator which was produced by Piezo transformer device, and compared Pulse-AC type with Piezo-electronic device such as decay time and ion balance for 10 weeks periods. As a result of this study, we found that Piezo transformer device has been maintained normal condition for 10 weeks. Also, we made the rule by this study, normally Piezo transformer device has to clean the electrode during every 11th weeks.

Film Thickness Dependence of Ac High Field for Low Density Polyethylene (저밀도 폴리에틸렌의 고전계 파형에 대한 필름 두께 의존성)

  • Choi, Yong-Sung;Wee, Sung-Dong;Hwang, Jong-Sun;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04c
    • /
    • pp.45-49
    • /
    • 2008
  • Polyethylene is widely used as the insulator for power cable. To investigate the conduction mechanism for power cable insulation under ac high field, it is very important to acquire the dissipation current under actual running field. Recently, we have developed the unique system, which make possible to observe the nonlinear dissipation current waveform. In this system, to observe the nonlinear properties with high accuracy, capacitive current component is canceled by using inverse capacitive current signal instead of using the bridge circuit for canceling it. We have already reported that the dissipation currents of $40\;{\mu}m$ thick LDPE film at 10 kV/mm and over 140 Hz, it starts to show nonlinearity and odd number's harmonics were getting large. To investigate the conduction mechanis ms in this region, especially space charge effect, various kinds of estimation, such as time variations of instantaneous resistivity for one cycle, FFT spectra of dissipation current waveforms and so on, has been examined. As the results of these estimations, it was found that the dissipation current will depend on not only the instantaneous value of electric field but also the time differential of applied electric field due to taking a balance between applied field and internal field. Furthermore, two large peaks of dissipation current for each half cycle were observed under certain condition. In this paper, to clarify the reason why it shows two peaks for each half cycle, the film thickness dependences of dissipation current waveforms were observed by using the three different thickness LDPE films.

  • PDF

WEC-Sim: A Simulator for Optimum Management of Wastewater Treatment Plant (WEC-Sim : 하수처리장 최적 운영을 위한 시뮬레이터)

  • Lee, Sung-Koo;Ahn, Sae-Young
    • Journal of Digital Contents Society
    • /
    • v.11 no.4
    • /
    • pp.463-471
    • /
    • 2010
  • In the management of a wastewater treatment plant which is a combination system of physical, chemical, and biological processes, computer simulator is an indispensable part for analysis of the operation status and evaluation of the treatment performance due to its fast computing speed. As an application software carrying out the data input-output operations and the mathematical calculations of the models, simulator is to be a powerful tool for estimating the treatment reaction and calculating mass balance of substrates, microorganisms, and chemicals within the treatment system in a given condition. Qualitative and quantitative prediction of treatment performance provides the plant manager with validity of decision-making through implementing modeling and simulation as a role of knowledge-based expert system in charge of automation and control. This paper shows the proceeding of design and development of the "WEC-Sim" software which is owned the various functions of data acquisition, monitoring, simulation, and control.

A Research Trend on Film Thickness Dependence of Ac High Feld for Low Density Polyethylene (저밀도 폴리에틸렌을 위한 고전계 파형의 필름 두께의존성에 관한 연구 동향)

  • Jung, Sung-Chan;Rho, Jung-Hyun;Lee, Joo-Hong;Hwang, Jong-Sun;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1988-1989
    • /
    • 2007
  • Polyethylene is widely used as the insulator for power cable. To investigate the conduction mechanism for power cable insulation under ac high field, it is very important to acquire the dissipation current under actual running field. Recently, we have developed the unique system, which make possible to observe the nonlinear dissipation current waveform. In this system, to observe the nonlinear properties with high accuracy, capacitive current component is canceled by using inverse capacitive current signal instead of using the bridge circuit for canceling it. We have already reported that the dissipation currents of $40\;{\mu}m$ thick LDPE film at 10 kV/mm and over 140 Hz, it starts to show nonlinearity and odd number's harmonics were getting large. To investigate the conduction mechanis ms in this region, especially space charge effect, various kinds of estimation, such as time variations of instantaneous resistivity for one cycle, FFT spectra of dissipation current waveforms and so on, has been examined. As the results of these estimations, it was found that the dissipation current will depend on not only the instantaneous value of electric field but also the time differential of applied electric field due to taking a balance between applied field and internal field. Furthermore, two large peaks of dissipation current for each half cycle were observed under certain condition. In this paper, to clarify the reason why it shows two peaks for each half cycle, the film thickness dependences of dissipation current waveforms were observed by using the three different thickness LDPE films.

  • PDF

Levodopa Transport through Skin using Iontophoresis: the Role of Electroosmosis and Electrorepulsion (이온토포레시스를 이용한 levodopa의 경피전달: electroosmosis 및 electrorepulsion의 역할)

  • Jung, Shin-Ae;Gwak, Hye-Sun;Chun, In-Koo;Oh, Seaung-Youl
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.1
    • /
    • pp.31-38
    • /
    • 2008
  • The objective of this work is to study transdermal delivery of levodopa using iontophoresis and evaluate various factors which affect the transdermal transport. Levodopa is unstable in aqueous solution, and, in order to establish a stable condition for levodopa for the duration of experiment, we investigated the stability of levodopa in aqueous solutions of different pHs with/without the addition of dextrose or the application of current. Using stable aqueous solution, we have studied the effect of pH, polarity and penetration enhancer (ethanol) on transdermal flux and compared the results. We also investigated the iontophoretic flux from hydroxypropyl cellulose (HPC) hydrogel. In vitro flux study was performed at $33^{\circ}C$, using side-by-side diffusion cell. Full thickness hairless mouse skin and rat skin were used for this work. Current densities applied were 0.4 or $0.6mA/cm^2$ and current was off after 6 hour application. Stability study showed that levodopa solution with a pH 2.5 or 4.5 maintained the initial concentration of levodopa for 24 hours with the addition of 5% dextrose. However, at pH 9.5, levodopa was unstable and 30 to 40% of levodopa degraded within 24 hours, even with the addition of 5% dextrose. Hydrogel swollen with dextrose added levodopa solution maintained about 97% of the initial concentration of levodopa for 13 days, when stored in $4^{\circ}C$. The application of current did not affect the stability of levodopa in hydrogel. Flux study from levodopa solution with pH 2.5 showed that cathodal delivery of levodopa was higher than passive or anodal delivery. When the pH of the donor solution was 4.5, anodal delivery of levodopa was higher than passive or cathodal delivery. These results seem to indicate that electroosmosis plays more dominant role than electrorepulsion in the flux of levodopa at pH 2.5, and the reverse situation applies for pH 4.5. The passive flux was unexpectedly high for the ionized levodopa. Similar to the results from aqueous solution, cumulative amount of levodopa transported trom HPC hydrogel by cathodal delivery was significantly higher than passive or anodal delivery. The treatment of 70% ethanol cotton ball by scrubbing increased passive, anodal and cathodal flux, with the largest increase for anodal flux. These results indicate that iontophoretic delivery of zwitterion such as levodopa is much complicated than that can be expected from small ionic molecules with single charge. The results also indicate that the balance between electroosmosis and electrorepulsion plays a very important role in the transport through skin.