• 제목/요약/키워드: Charge Reservoir

검색결과 27건 처리시간 0.027초

가변 컨덕턴스 히트파이프의 열특성에 관한 해석 (Analysis on the Thermal Characteristics of Variable Conductance Heat Pipe)

  • 김근오;김무근;박병규
    • 설비공학논문집
    • /
    • 제13권1호
    • /
    • pp.38-47
    • /
    • 2001
  • The operation characteristics of variable conductance heat pipe(VCHP) were numerically investigated by using 1-dimensional diffuse-front model. For different boundary conditions, the amount of non-condensible gas charge and dimension of gas reservoir were obtained by iterative calculation. It is found that the amount of non-condensible gas charge and dimensions of gas reservoir have an effect on the temperature control of condenser for the given operating condition of VCHP. The numerical results show that VCHP has an excellent capability of temperature control when subjected to a change in the heat input.

  • PDF

Housing / Urban Development Integrated with Flood-Control Reservoirs in Japan

  • Watanabe, Naoyuki
    • 토지주택연구
    • /
    • 제5권3호
    • /
    • pp.203-214
    • /
    • 2014
  • The purpose of this paper is to introduce two integrated urban development projects in Japan that take full advantage of flood-control reservoirs: the Tetsugakudo Park Collective Housing Development Project and the Koshigaya Lake Town Project. The former project - implemented cooperatively by the Tokyo metropolitan government in charge of river management, Shinjuku and Nakano wards (in Tokyo) responsible for park management, and the Urban Renaissance Agency, a housing project developer - set a significant precedent for three-dimensional river use by realizing the three-dimensional integrated development of a flood control reservoir, a park, and collective housing. The Koshigaya Lake Town Project, launched as a drastic storm water management measure for a low-lying area often plagued by flooding, has achieved a sustainable coexistence between the waterfront environment and the urban living environment, with an artificial flood-control reservoir as the core for urban development. This project is fully committed to environmental coexistence through the optimal use of local environmental resources, with the cooperation of the central government, Saitama Prefecture and Koshigaya City.

Design and Implementation of Fully Automated Solar Powered Irrigation System

  • Mohammad Fawzi Al Ajlouni;Essam Ali Al-Nuaimy;Salman Abdul-Rassak Sultan;Ali Hammod AbdulHussein Twaij;Al Smadi Takialddin
    • International Journal of Computer Science & Network Security
    • /
    • 제24권4호
    • /
    • pp.197-205
    • /
    • 2024
  • This paper presents a fully automated stand-alone irrigation system with GSM (Global System for Mobile Communication) module. Solar energy is utilized to power the system and it is aimed to conserve water by reducing water losses. The system is based on a DC water pump that draws energy from solar panels along with automated water flow control using a moisture sensor. It is also fitted with alert and protection system that consists of an ultrasonic sensor and GSM messages sender that transmits signals showing the levels of the water in the reservoir and the battery charge. The control system is designed to stop the water pump from pumping water either when the battery level drops to equal or less than 10% of its full charge, or when the water level becomes less than 10 cm high in the reservoir. The experimental results revealed that the system is appropriate to use in remote areas with water scarcity and away from the national grid.

관개용수로의 자동수위측정 자료를 활용한 농업용 저수지 공급량 산정 및 분석 (Assessing Irrigation Water Supply from Agricultural Reservoir Using Automatic Water Level Data of Irrigation Canal)

  • 방재홍;최진용;윤푸른;오창조;맹승진;배승종;장민원;장태일;박명수
    • 한국농공학회논문집
    • /
    • 제63권1호
    • /
    • pp.27-35
    • /
    • 2021
  • KRC (Korea Rural Community Corporation) is in charge of about 3,400 agricultural reservoirs out of 17,240 agricultural reservoirs, and automatic water level gauges in reservoirs and canals were installed to collect reservoir and canal water level data from 2010. In this study, 10-minute water level data of 173 reservoir irrigation canals from 2016 to 2018 are collected, and discharge during irrigation season was calculated using rating curves. For estimation of water supply, irrigation water requirement was calculated with HOMWRS (Hydrological Operation Model for Water Resources System), and the summation of reservoir water storage decrease was calculated with daily reservoir storage data from RAWRIS (Rural Agricultural Water Resource Information System). From the results, the total yearly amount of irrigation water supply showed less than 10% difference than the irrigation water requirement. The regional analysis revealed that reservoirs in Jeollanam-do and Chungcheongnam-do supply greater irrigation water than average. On the contrary, reservoirs in Gyeongsangnam-do and Chungcheongbuk-do supply less than others. This study was conducted with a limited number of reservoirs compared to total agricultural reservoirs. Nevertheless, it can indicate irrigation water supply from agricultural reservoirs to provide information about agricultural water use for irrigation.

충전율의 변화가 밀폐형 2-상 열사이폰의 열전달 특성에 미치는 영향에 관한 연구 (The Effect of the Fill Charge Ratio on the Heat Transfer Characteristics of a Two-Phase Closed Thermosyphon)

  • 박용주;홍성은;김철주
    • 대한기계학회논문집B
    • /
    • 제26권12호
    • /
    • pp.1646-1654
    • /
    • 2002
  • A two-phase closed thermosyphon was one of the most effective devices in the removing heat because of its simple structure, thermal diode characteristics, wide operating temperature range and so on. In this study, a two-phase closed thermosyphon(working fluid PFC(C6F14), container copper(inner grooved surface)) was fabricated with a reservoir which can change the fill charge ratio. The experiments were performed in the range of 50~600W heat flow rate and 10~70% fill charge ratio. The results were compared with some correlations that were presented by Rohsenow and Immura et al. in the evaporator, by Nusselt, Gross and Uehara et al. in the condenser and by Cohen and Bayley, Wallis, Kutateladze and Faghri et al. in heat transfer limitation etc.. The heat transfer coefficient at the evaporator increased with the input power. However the effect of the fill charge ratio was nearly negligible. At the condenser, it showed an opposite trend to the evaporator and with increase of the fill charge ratio, showed some enhancement of heat transfer. The heat transport limitation was occurred by the dry-out limitation for small fill charge ratio(10%) and presented about 100W. For the case of large fill charge ratio(Ψ$\geq$40%), it was occurred by the flooding limitation at about 500W.

시.군 관리 저수지 실태 조사 및 정비방안에 관한 연구 (Survey for the Management of Reservoirs under Control of Local Authorities of Reservoir of City.Gun in Korea)

  • 최원;김한중;윤성수;김종옥;정남수;이형진;한이철;이정재
    • 한국농공학회논문집
    • /
    • 제50권3호
    • /
    • pp.31-41
    • /
    • 2008
  • There are many agricultural facilities (46.7%) that have been over 30 years in the Republic of Korea (the ratio of reservoirs built before 1945 is 53%, from 1946 to 1971 is 35%). In the case of reservoirs which do most important functions among these facilities, only 3,000 reservoirs are managed by Korea Rural Community & Agriculture Corporation (KRC) and the other 15,000 reservoirs are managed by local authorities (City and Gun). But, 15,000 reservoirs included in City. Gun have been built in more wide area than KRC and the reservoir management system has not been operated well because of shortage of budget and manpower of the local authorities. Particularly, the abnormal weather happened during every summer season recently has ruined a lot of rural community facilities. So flood control function have been more important than irrigation function in agricultural reservoir system and it may be required to introduce new safe, management and maintenance techniques in City Gun reservoirs. So we investigated landscapes and deteriorations of agricultural reservoirs managed by local small governments for revealing not only present usage but also future value. Survey shows that there are no structural managements except typical hydrological reportings and the deterioration of small darn is very serious. There are needs for more systematic management system and equipment methods. Therefore, this study may suggest that reservoir (that takes charge of the greatest deal of weight in all agricultural facilities) must be considered as new concept of the usage and the unification. On the other hand, reservoir must be also developed as amenity resources, natural circumstances and district values.

전력변환 반도체 냉각용 PFC(FC-72) 밀폐형 2상 열사이폰의 열전달 한계에 관한 연구 (A Study on the Heat Transport Limitations of a PFC(FC-72) Two-Phase Closed Thermosyphon for Cooling Power Semiconductors)

  • 박용주;홍성은;김철주
    • 설비공학논문집
    • /
    • 제14권9호
    • /
    • pp.725-733
    • /
    • 2002
  • In this study, the heat transport limitations of a two-phase closed thermosyphon were investigated. For the test, a two-phase closed thermosyphon ($L_t/: 600 mm,\;L_e:105mm,\;L_a:75mm,\;L_c:420mm,\;D_o:22.2mm,$ container: copper (inner grooved surface), working fluid: PFC ($C_6F_14$) was fabricated with a reservoir that can change the fill charge ratio. The following was imposed as the factors on the heat transport limitations of a two-phase closed thermosyphon. 1) Fill charge ratio of the working fluid. 2) Tilt angle of the longitudinal axis. From tile experimental data, some results were obtained as follows. When the fill charge ratio was relatively small ($\psi$20%), the heat transport limitation occurred about 100W by dry-out limitation. However over 40%, it shelved nearly constant value (500 W) by flooding limitation. The heat transport limitation according to the tilt angle increased smoothly until the tilt angle was $60^{\circ}$,/TEX>, after then decreased slowly.

토지이용이 이원천 유역의 하천수질에 미치는 영향 (Influence on the Land Use Factors Affecting the Water Quality of Iwonchon Basin)

  • 이호준;방제용;김용옥
    • The Korean Journal of Ecology
    • /
    • 제22권5호
    • /
    • pp.235-240
    • /
    • 1999
  • 토지이용이 어떻게 수질에 영향을 주는가를 연구하고자 1993년 3월 부터 1998년 3월 까지 조사를 실시하였다. 조사지는 충북 옥천군 이원면의 경작지가 주류를 이루는 개심저수지와 산지유역으로 특성지워지는 장찬저수지 유역을 대상으로 하였다. 조사유역을 11개 소집수역으로 세분하고 토지이용과 하천수질과의 상관성, 하천 유역의 오염원 동태를 생태학적 관점에서 규명하고자 조사를 실시하였다. BOD, SS, TKN은 하류로 갈수록 높아졌으나 자정 한계를 넘어선 G 소집수역은 예외였다. 장찬저수지 유역은 가두리 양식장 때문에 수질이 악화되어 있는 것으로 나타나 양식장의 폐쇄가 시급한 것으로 조사되었다. .해발표고는 200 m 이하가 개심저수지 유역 56.0%, 장찬저수지 유역 44.0%로 대부분을 차지하였다. 비삼림지역은 전체 조사면적 44.91 ㎢중 14.74 ㎢로 32.8%를 차지하였는데 특히 경작지와 주거지 면적 비의 증가에 따라 총인(Y=0.2023X+0.0991, r=0.54)이 증가되고 있다. 토지이용별 오염 배출원 단위가 수질에 미치는 영향을 분석한 결과 농경지의 오염부하량은 매우 크며 비점오염물질이 하천에 유입, 유하 하는 동안 물리, 화학, 생화학적, 생물학적 변화를 거쳐 농도가 낮아지고 있다. 그러나 삼림지역의 오염부하량은 농경지의 오염부하량 보다는 상대적으로 작으나 오히려 하천으로 유입, 유하하는 동안 오염 물질의 양이 높아졌다.

  • PDF

유수지 공간을 활용한 주거지개발 사례연구 -일본 철학당 공원(테츠가쿠도 코우엔) 주거단지 사례를 중심으로- (A Case Study on the Housing Development by Using the Space of Retarding Basin - Focused on the Tetsugakudo Kouen Collective Housing Development Project -)

  • 백승관;김영훈
    • KIEAE Journal
    • /
    • 제15권1호
    • /
    • pp.129-137
    • /
    • 2015
  • The purpose of this study is to analyze the Tetsugakudo Kouen Collective Housing Development Project in Japan. Project implemented cooperatively by the Tokyo Metropolitan Government in charge of river management, Shinjuku and Nakano-ku responsible for park management, and the UR, a housing project developer. This project set a significant precedent for three-dimensional river use by realizing the three-dimensional integrated development of a flood control reservoir, a park, and collective housing. The major effectiveness of this project can be summarized into four points. 1) The costs borne by individual project developers were significantly reduced by realizing a high degree of application and multipurpose use of the land through a joint project. 2) This project, which was designed to accommodate rainfall of 30 to 40mm per hour, is expected to contribute to reducing flood damage and generating significant investment effects, in terms of asset value in downstream areas, thereby increasing flood control security. 3) Local disaster prevention function were enhanced by providing an evacuation site in the case of an earthquake. 4) The living environment was improved by adding the function of a park.

Bayesian 추계학적 신뢰도 기법을 이용한 소양강댐 퇴사용량 감소의 불확실성 분석 (Identification of Uncertainty on the Reduction of Dead Storage in Soyang Dam Using Bayesian Stochastic Reliability Analysis)

  • 이철응;김상욱
    • 한국수자원학회논문집
    • /
    • 제46권3호
    • /
    • pp.315-326
    • /
    • 2013
  • 저수지 내 퇴적과정으로 의한 저수용량 감소에 대한 효율적 관리의 중요성에도 불구하고, 불확실성을 포함하는 확률론적 관점의 신뢰도 분석이론을 활용한 저수용량 감소에 관한 연구는 많지 않다. 본 연구에서는 신뢰도 분석모형의 하나인 추계학적 감마 과정(stochastic gamma process)을 이용하고 개발된 모형을 소양강댐에서 적용하여 향후 발생될 수 있는 저수용량의 감소를 불확실성 측면에서 분석하였다. 특히 불확실성을 분석하기 위하여 정보적 사전분포(informative prior distribution)를 이용한 Bayesian MCMC 기법을 사용하여 추계학적 감마 과정의 모수(parameter)를 추정하였다. 구축된 정보적 사전분포를 적용한 결과사전분포의 불확실성에 비해 사후분포의 불확실성이 상당히 감소되어져 정보적 사전분포의 효과를 확인할 수 있었으며, 소양강댐 퇴사용량의 기대수명은(expected life time)은 5%유의수준에서 119.3년부터 183.5년의 불확실성을 나타내는 것으로 분석되었다. 이와 같은 연구는 저수용량의 감소에 관한 불확실성 측면의 정보를 신뢰도 분석결과와 함께 제공할 수 있으므로, 향후 퇴적과정으로 인한 저수지의 유지관리계획을 수립함에 있어 댐관리자 등에게 효과적으로 활용될 수 있을 것으로 판단된다.