남극 세종기지에서의 지표 플럭스 관측: I. 난류 특성과 현열 플럭스 (Surface Flux Measurements at King Sejong Station in West Antarctica: I. Turbulent Characteristics and Sensible Beat Flux)

  • 최태진;이방용;이희춘;심재설
    • Ocean and Polar Research
    • /
    • 제26권3호
    • /
    • pp.453-463
    • /
    • 2004
  • The Antarctic Peninsula is important in terms of global warming research due to pronounced increase of air temperature over the last century. The first eddy covariance system was established at King Sejong Station located in the northern region of the Antarctic Peninsula in December of 2002 and has been operated over one year. Here, we analyze turbulent characteristics to determine quality control criteria for turbulent sensible heat flux data as well as to diagnose the possibility of long term eddy covariance measurement under extreme weather conditions of the Antarctic Peninsula. We also report the preliminary result on sensible heat flux. Based on the analyses on turbulent characteristics such as integral turbulence characteristics of vertical velocity (w) and heat (T), stationarity test and investigation of correlation coefficient, they fallow the Monin-Obukhov similarity and eddy covariance flux data were reliable. ${\sim}47%$ of total retrieved sensible heat flux data could be used for further analysis. Daytime averaged sensible heat flux showed a pronounced seasonal variation, with a maximum of up to $300Wm^{-2}$ in summer. In conclusion, continuous and long-term eddy covariance measurement may be possible at the study site and the land surface may influence the atmosphere significantly through heat transport in summer.

3차 권선을 이용한 자속구속형 사고전류제한기의 특성 (Characteristics of Flux-Lock Type Superconducting Fault Current Limiter Using Third Winding)

  • 조용선;박형민;박충렬;임성훈;최효상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.87-89
    • /
    • 2005
  • In this paper, we analyzed that characteristics of flux-lock type superconducting fault current limiter (SFCL) using the third winding to fault current limiting. The flux-lock type SFCL using the third winding consists of the first and seconding windings which are wound in parallel each other a iron core. Also it connected inductively the third winding connected resistance of series. Because of the hysteresis according to the increased voltage, the distortion of current in the flux-lock type SFCL occurs. It is a disadvantage to increase the capacity of SFCL. We conformed that the third winding of the flux-lock type SFCL prevented the distortion of current. Also, the third winding did not affect the initial fault current of the flux-lock type SFCL.

  • PDF

석영 가열램프의 열 유속 특성 파악을 통한 고온 구조시험의 열 하중 설계에 관한 연구 (A Study on Heat Flux Characteristics of Tubular Quartz Lamp for Thermal Load Design of High Temperature Structural Test)

  • 김준혁
    • 한국군사과학기술학회지
    • /
    • 제25권4호
    • /
    • pp.355-363
    • /
    • 2022
  • Development of supersonic flying vehicle is one of the most latest issue in modern military technology. Specifically, structural integrity of supersonic flying vehicle can be verified by high temperature structural test. High temperature structural test is required to consider thermal load caused by aerodynamic heating while applying structural load simultaneously. Tubular quartz lamps are generally used to generate thermal load by emitting infrared radiation. In this study, modified heat flux model of tubular quartz lamp is proposed based on existing model. Parameters of the proposed model are optimized upon measured heat flux in three dimensions. Finally, thermal load of plate specimen is designed by the heat flux model. In conclusion, it is possible to predict heat flux applied on plate specimen and desired thermal load of high temperature structural test can be obtained.

Lactic Acid Bacteria의 동역학 네트워크 모델을 이용한 in Silico 모사방법 연구 (Study of in Silico Simulation Method for Dynamic Network Model in Lactic Acid Bacteria)

  • 정의섭;이혜원;이진원
    • 제어로봇시스템학회논문지
    • /
    • 제11권10호
    • /
    • pp.823-829
    • /
    • 2005
  • We have newly constructed an in silico model of fermentative metabolism for Lactococcus lactis in order to analyze the characteristics of metabolite flux for dynamic network. A rigorous mathematical model for metabolic flux has been developed and simulation researches have been performed by using GEPASI program. In this simulation task, we were able to predict the whole flux distribution trend for lactate metabolism and analyze the flux ratio on the pyruvate branch point by using metabolic flux analysis(MFA). And we have studied flux control coefficients of key reaction steps in the model by using metabolic control analysis(MCA). The role of pyruvate branch seems to be essential for the secretion of lactate and other organic byproducts. Then we have made an effort to elucidate its metabolic regulation characteristics and key reaction steps, and find an optimal condition for the production of lactate.

자속구속형 고온초전도 사고전류 제한기의 히스테리시스 특성 분석 (Analysis on Hysteresis Characteristics of Flux-Lock Type HTSC Fault Current Limiter)

  • 임성훈;한병성;박형민;조용선;한태희;두호익;최효상
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.493-495
    • /
    • 2006
  • The hysteresis characteristics of flux-lock reactor, which is an essential component of flux-lock type superconducting fault current limiter (SFCL), was investigated. The hysteresis loss of iron core in flux-lock type SFCL does not happen due to its winding's structure especially in the normal state. From the equivalent circuit for the flux-lock type SFCL and the fault current limiting experiments, the hysteresis curves could be drawn. Through the hysteresis curves together with the fault current level due to the inductance ratio for the 1st and 2nd windings, the increase of the number of turns in the 2nd winding of the flux-lock type SFCL had a role to prevent the iron core from saturation.

  • PDF

보성 농업지역에서의 장기간 플럭스 특성 분석 (Long Term Flux Variation Analysis on the Boseong Paddy Field)

  • 이영태;황성은;김병택;김기훈
    • 대기
    • /
    • 제34권1호
    • /
    • pp.69-81
    • /
    • 2024
  • In this paper, Annual flux variations in the Boseong Tall Tower (BTT) from 2016 to 2020 were analyzed using data from three levels (2.5 m, 60 m, and 300 m). BTT was installed in Boseong-gun, Jeollanam-do in February 2014 and continued to conduct energy exchange observations such as CO2, sensible heat, and latent heat using the eddy covariance method until March 2023. The BTT was located in a very flat and uniform paddy field, and flux observations were conducted at four levels: 2.5 m, 60 m, 140 m, and 300 m above ground. Surface energy balance was confirmed from observed data of net radiation flux, soil heat flux, sensible heat flux, and latent heat flux. Additionally, 2.5 m height surface fluxes, which are most influenced by agricultural land, were compared with data from Local Data Assimilation and Prediction System (LDAPS) of the Korea Meteorological Administration to evaluate the accuracy of LDAPS flux data. The correlation coefficient between LDAPS flux data and observed values was 0.95 or higher. Excluding summer latent heat flux data, there was a general tendency for LDAPS data to be higher than observed values. The footprint areas estimated below 60 m height mainly covered agricultural land, and flux observations at 2.5 m and 60 m heights showed typical agricultural characteristics. In contrast, the footprint estimated at 300 m height did not show agricultural characteristics, indicating that observations at this height encompassed a wide range, including mountains, sea, and roads. The analysis results of long-term flux observations can contribute to understanding the energy and carbon dioxide fluxes in agricultural fields. Furthermore, these results can be utilized as essential data for validating and improving numerical models related to such fluxes.

자속 구속형 고온초전도 전류제한기의 동작특성 분석 (The Analysis of Operation Characteristics of Flux-Lock Type High-Tc Superconducting Fault Currents Limiter)

  • 박충렬;임성훈;박형민;이종화;고석철;최효상;한병성;현옥배;정동철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1130-1132
    • /
    • 2004
  • In this paper, we investigated the operational characteristics of the fault current limiting in the The flux-lock type high-Tc superconducting fault current limiter. The flux-lock type high-Tc superconducting fault current limiter was consisted of primary and secondary copper coils that flux was locked on iron core and YBCO thin film. The operational characteristic of a flux-lock type SFCL dependent on winding direction of coil 1 and coil 2, and the number of turns of coil 1 and coil 2, inductances of the coils, saturation in iron core, the properties of superconducting element etc. In this cases, we investigated the fault currents limiting characteristics of the flux-lock type SFCL when winding direction of coil 1 and coil 2 was subtractive polarity winding.

  • PDF

등가자기회로 모델을 이용한 종자속형 자기부상 전자석의 부상력 특성 해석 (Analysis on the Levitation Force Characteristics of Longitudinal Flux Type Levitation Magnet using Equivalent Magnetic Circuit Model)

  • 조한욱;김창현;이종민;한형석
    • 전기학회논문지
    • /
    • 제60권12호
    • /
    • pp.2236-2245
    • /
    • 2011
  • This paper deals with the levitation force characteristics of electromagnet for MAGLEV vehicle application. The magnetic flux density distribution and levitation force characteristics of the electromagnet are investigated by means of equivalent magnetic circuit model. Firstly, we defined the aligned and unaligned electromagnet module for the full-electromagnet, and magnetic flux paths are represented for each model including leakage and fringing flux paths. Because of the analysis model contains both the permanent magnet and electromagnet coil, we calculated the airgap magnetic flux density and levitation forces using flux superposition in electromagnetic circuit. The results are validated extensively by comparison with finite element analysis. Moreover, the 1/4 scaled magnetic levitation and propulsion test vehicle has been manufactured and tested in order to verify these predictions. The experimental results confirms the validity of the analytical prediction with equivalent magnetic circuit model for the description of a electromagnet.

자속커플링 SFCL의 사고전류 변화에 따른 전류제한특성 분석 (Characteristics according to increase of the fault current level of Flux-Coupling Type Superconducting Fault Current Limiter(SFCL))

  • 김용진;한병성;두호익;박충렬;두승규;김민주;하승룡
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.288-288
    • /
    • 2008
  • The flux-coupling type superconducting fault current limiter(SFCL) is composed of a series transformer and superconducting unit of the YBCO thin films. The primary and secondary coils in the transformer were wound in series each other through an iron core and the YBCO thin film was connected with secondary coil in parallel. In a normal condition, the flux generated from a primary coil is cancelled out by its structure and the zero resistance of the YBCO thin films. When a fault occurs, the resistance of the YBCO thin films was generated and the fault current was limited by the SFCL. In this paper, we investigated the fault current limiting characteristics according to fault current level in the flux-coupling type SFCL. The experiment results that the fault current limiting characteristics was improved according to increase of the fault current level.

  • PDF

삼상 분리형 자속구속형 전류제한기의 동작 특성 분석 (Analysis of Operational Characteristics of Separated Three-Phase Flux-Lock SFCL)

  • 두승규;두호익;박충렬;김민주;김용진;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.289-289
    • /
    • 2008
  • We investigated the operational characteristics of the separated three-phase flux-lock type superconducting fault current limiter (SFCL). The single-phase lock type SFCL consist of two coils, which are wound in parallel through an iron core. The high-$T_c$ superconducting(HSTC) thin film connected in series with secondary coil. The separated three-phase flux-lock type SFCL consist of three single-phase flux-lock type SFCL. In a normal condition, the SFCL is not operate. When a fault occurs, the current of a HSTC thin film exceeds its critical current by fault current, the resistance of the HSTC thin film generated. Therefore fault current was limited by SFCL. The separated three-phase flux-lock type SFCL are operated in fault condition such as the the single line-to-ground fault, the double line-to-ground fault and the triple line-to-ground fault. The experimental results, the SFCL operational characteristics was dependent on fault condition.