• Title/Summary/Keyword: Characteristics of Heat Transfer

Search Result 2,670, Processing Time 0.033 seconds

Characteristics of a planar Bi-Sb multijunction thermal converter with Pt-heater (백금 히터가 내장된 평면형 Bi-Sb 다중접합 열전변환기의 특성)

  • Lee, H.C.;Kim, J.S.;Ham, S.H.;Lee, J.H.;Lee, J.H.;Park, S.I.;Kwon, S.W.
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.154-162
    • /
    • 1998
  • A planar Bi-Sb multijunction thermal converter with high thermal sensitivity and small ac-dc transfer error has been fabricated by preparing the bifilar thin film Pt-heater and the hot junctions of thin film Bi-Sb thermopile on the $Si_{3}N_{4}/SiO_{2}/Si_{3}N_{4}$-diaphragm, which functions as a thermal isolation layer, and the cold junctions on the dielectric membrane supported with the Si-substrate, which acts as a heat sink, and its ac-dc transfer characteristics were investigated with the fast reversed dc method. The respective thermal sensitivities of the converter with single bifilar heater were about 10.1 mV/mW and 14.8 mV/mW in the air and vacuum, and those of the converter with dual bifilar heater were about 5.1 mV/mW and 7.6 mV/mW, and about 5.3 mV/mW and 7.8 mV/mW in the air and vacuum for the inputs of inside and outside heaters, indicating that the thermal sensitivities in the vacuum, where there is rarely thermal loss caused by gas, are higher than those in the air. The ac-dc voltage and current transfer difference ranges of the converter with single bifilar heater were about ${\pm}1.80\;ppm$ and ${\pm}0.58\;ppm$, and those of the converter with dual bifilar heater were about ${\pm}0.63\;ppm$ and ${\pm}0.25\;ppm$, and about ${\pm}0.53\;ppm$ and ${\pm}0.27\;ppm$, respectively, for the inputs of inside and outside heaters, in the frequency range below 10 kHz and in the air.

  • PDF

A study on freeze-thaw evaluation criteria for road tunnels considering climate characteristics (국내 기후특성을 고려한 도로터널의 동결-융해 평가기준 연구)

  • Moon, Joon-Shik;An, Jai-Wook;Kim, Hong-Kyoon;Lee, Jong-Gun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.1
    • /
    • pp.121-133
    • /
    • 2020
  • Globally, the frequency and intensity of abnormal climate events are increasing. Since this can directly damage lives and property, it is important to establish and implement an appropriate maintenance strategy in response to abnormal weather. Facilities built in cold regions where cold wave or heavy snow occurs frequently can be more damaged by freeze-thaw than facilities located in other regions. However, there are no clear criteria for quantitatively identifying the damage of freeze-thaw and how to cope with it. Therefore, based on the results of indoor freezing tests, the freezing conditions considering regional climate characteristics were selected as one day at -14℃, two days at -7℃ or three days at -5℃. As a result, it was confirmed that they were in the freeze-thaw environment in order of Daegwallyeing (8.3 times), Cheorwon (5.3 times) and Taebeak (4.9 times) in Gangwon region. Through this study, the evaluation criteria of freeze-thaw of road tunnels were newly proposed. The freeze-thaw evaluation criteria of the road tunnel presented in this study can be used for the quantitative evaluation and maintenance strategy of tunnels in cold regions.

Effect on Graphene Addition on Characteristics of Polypropylene Biocomposites Reinforced with Sulfuric Acid Treated Green Algae (황산처리된 녹조류 보강 폴리프로필렌 바이오복합재료에 대한 그래핀 첨가영향)

  • Jang, Young Hun;Han, Seong Ok;Kim, Hyung-Il;Sim, I Na
    • Polymer(Korea)
    • /
    • v.37 no.4
    • /
    • pp.518-525
    • /
    • 2013
  • To improve the mechanical properties of polypropylene (PP) biocomposites reinforced with sulfuric acidtreated green algae (SGA), SGA/graphite nanoplatelets (GNP)/PP biocomposites were prepared and their properties were evaluated depending on the particle size and content of GNP. The flexural and impact strength of SGA/GNP/PP biocomposites decreased with the addition of GNP, whereas the flexrual and storage moduli were greatly improved with increasing GNP loading. SGA/GNP/PP biocomposites reinforced with GNP5 showed generally better mechanical properties compared to that reinforced with GNP15 mainly due to the improved dispersion of the smaller GNP. SGA/GNP/PP biocomposites reinforced with GNP5 showed a lower resistance to the thermal expansion because the relatively uniform dispersion of smaller GNP was responsible for the effective heat transfer to the polymer matrix. As a result, SGA/GNP/PP biocomposite was acceptable for the general purpose application due to the improved flexural resistance, storage moduli, and damping characteristics.

Thermo-mechanical Behavior Characteristic Analysis of $B^2it$(Buried Bump Interconnection Technology) in PCB(Printed Circuit Board) (인쇄회로기판 $B^2it$(Buried Bump Interconnection Technology) 구조의 열적-기계적 거동특성 해석)

  • Cho, Seung-Hyun;Chang, Tae-Eun
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.16 no.2
    • /
    • pp.43-50
    • /
    • 2009
  • Although thin PCBs(Printed Circuit Boards) have recently been required for high density interconnection, high electrical performance, and low manufacturing cost, the utilization of thin PCBs is severely limited by warpage and reliability issues. Warpage of the thin PCB leads to failure in solder-joints and chip. The $B^2it$(Buried Bump Interconnection Technology) for PCB has been developed to achieve a competitive manufacturing price. In this study, chip temperature, package warpage, chip stress and solder-joints stress characteristics of the PCB prepared with $B^2it$ process have been calculated using thermo-mechanical coupled analysis by the FEM(Finite Element Method). FEM computation was carried out with the variations in bump shapes and kinds of materials under 1.5W power of chip and constant convection heat transfer. The results show that chip temperature distribution reached more quickly steady-state status with PCB prepared with $B^2it$ process than PCB prepared with conventional via interconnection structure. Although $B^2it$ structures are effective on low package warpage and chip stress, with high strength bump materials arc disadvantage for low stress of solder-joints. Therefore, it is recommended that optimized bump shapes and materials in PCB design should be considered in terms of reliability characteristics in the packaging level.

  • PDF

Growth characteristics of pathogens isolated from surface of carcass (도체표면에서 분리한 병원성 미생물의 성장특성)

  • 정영숙;박나영;이신호
    • Food Science and Preservation
    • /
    • v.9 no.4
    • /
    • pp.434-440
    • /
    • 2002
  • The growth characteristics of 5. coli O157:H7 CDFI, A. sobria CDF3 and S. aureus CDF2 isolated from surface of carcass were investigated to improve hygienic quality of beef. The total count of carcass surface before washing was higher than that of after washing. Total count of after cooling decreased about 10$^1$∼ 10$^2$/㎠ compare with before cooling. Total count of carcass surface after transfer increased regardless seasons. The growth E. coli O157:H7 CDF1 occurred at pH 4 and 6% NaCl but A. sobria CDF3 and S. aureus CDF2 did not grow at the same conditions. Although the growth of E. coli O157:H7 CDF1 and S. aureus CDF2 was inhibited by 0.3% lactic acid, but A sobria CDF3 did not grow in TSB containing 0.3% lactic acid. E. coli O157:H7 CDF1 grew rapidly after 3 days incubation at 10$\^{C}$ but did not grow at 4$\^{C}$. But A. sobria CDF3 grew rapidly after 3 days incubation at 4$\^{C}$. E. coli O157:H7 CDF1 and A. sobria CDF3 were destroyed by heat treatment for 3 min at 60$\^{C}$. S. aureus CDF2 did not detect after heat treatment for 2 min at 70$\^{C}$.

Estimation of Soil Cooling Load in the Root Zone of Greenhouses (온실내 근권부의 지중냉각부하 추정)

  • 남상운
    • Journal of Bio-Environment Control
    • /
    • v.11 no.4
    • /
    • pp.151-156
    • /
    • 2002
  • Root zone cooling, such as soil or nutrient solution cooling, is less expensive than air cooling in the whole greenhouse and is effective in promoting root activity, improving water absorption rate, decreasing plant temperature, and reducing high temperature stress. The heat transfer of a soil cooling system in a plastic greenhouse was analyzed to estimate cooling loads. The thermal conductivity of soil, calculated by measured heat fluxes in the soil, showed the positive correlation with the soil water content. It ranged from 0.83 to 0.96 W.m$^{[-10]}$ .$^{\circ}C$$^{[-10]}$ at 19 to 36% of soil water contents. As the indoor solar radiation increased, the temperature difference between soil surface and indoor air linearly increased. At 300 to 800 W.m$^{-2}$ of indoor solar radiations, the soil surface temperature rose from 3.5 to 7.$0^{\circ}C$ in bare ground and 1.0 to 2.5$^{\circ}C$ under the canopy. Cooling loads in the root zone soil were estimated with solar radiation, soil water content, and temperature difference between air and soil. At 300 to 600 W.m$^{-2}$ of indoor solar radiations and 20 to 40% of soil water contents,46 to 59 W.m$^{-2}$ of soil cooling loads are required to maintain the temperature difference of 1$0^{\circ}C$ between indoor air and root zone soil.

A Study on the Optimum Design of Multiple Screw Type Dryer for Treatment of Sewage Sludge (하수슬러지 처리를 위한 다축 스크류 난류 접촉식 건조기의 최적 설계 연구)

  • Na, En-Soo;Shin, Sung-Soo;Shin, Mi-Soo;Jang, Dong-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.4
    • /
    • pp.223-231
    • /
    • 2012
  • The purpose of this study is to investigate basically the mechanism of heat transfer by the resolution of complex fluid flow inside a sophisticated designed screw dryer for the treatment of sewage sludge by using numerical analysis and experimental study. By doing this, the result was quite helpful to obtain the design criteria for enhancing drying efficiency, thereby achieving the optimal design of a multiple screw type dryer for treating inorganic and organic sludge wastes. One notable design feature of the dryer was to bypass a certain of fraction of the hot combustion gases into the bottom of the screw cylinder, by the fluid flow induction, across the delicately designed holes on the screw surface to agitate internally the sticky sludges. This offers many benefits not only in the enhancement of thermal efficiency even for the high viscosity material but also greater flexibility in the application of system design and operation. However, one careful precaution was made in operation in that when distributing the hot flue gas over the lump of sludge for internal agitation not to make any pore blocking and to avoid too much pressure drop caused by inertial resistance across the lump of sludge. The optimal retention time for rotating the screw at 1 rpm in order to treat 200 kg/hr of sewage sludge was determined empirically about 100 minutes. The corresponding optimal heat source was found to be 150,000 kcal/hr. A series of numerical calculation is performed to resolve flow characteristics in order to assist in the system design as function of important system and operational variables. The numerical calculation is successfully evaluated against experimental temperature profile and flow field characteristics. In general, the calculation results are physically reasonable and consistent in parametric study. In further studies, more quantitative data analyses such as pressure drop across the type and loading of drying sludge will be made for the system evaluation in experiment and calculation.

Thermal-hydraulic research on rod bundle in the LBE fast reactor with grid spacer

  • Liu, Jie;Song, Ping;Zhang, Dalin;Wang, Shibao;Lin, Chao;Liu, Yapeng;Zhou, Lei;Wang, Chenglong;Tian, Wenxi;Qiu, Suizheng;Su, G.H.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2728-2735
    • /
    • 2022
  • The research on the flow and heat transfer characteristics of lead bismuth(LBE) is significant for the thermal-hydraulic calculation, safety analysis and practical application of lead-based fast reactors(LFR). In this paper, a new CFD model is proposed to solve the thermal-hydraulic analysis of LBE. The model includes two parts: turbulent model and turbulent Prandtl, which are the important factors for LBE. In order to find the best model, the experiment data and design of 19-pin hexagonal rod bundle with spacer grid, undertaken at the Karlsruhe Liquid Metal Laboratory (KALLA) are used for CFD calculation. Furthermore, the turbulent model includes SST k - 𝜔 and k - 𝜀; the turbulent Prandtl includes Cheng-Tak and constant (Prt =1.5,2.0,2.5,3.0). Among them, the combination between SST k - 𝜔 and Cheng-Tak is more suitable for the experiment. But in the low Pe region, the deviation between the experiment data and CFD result is too much. The reason may be the inlet-effect and when Pe is in a low level, the number of molecular thermal diffusion occupies an absolute advantage, and the buoyancy will enhance. In order to test and verify versatility of the model, the NCCL performed by the Nuclear Thermal-hydraulic Laboratory (Nuthel) of Xi'an Jiao tong University is used for CFD to calculate. This paper provides two verification examples for the new universal model.

Numerical Modeling of Thermoshearing in Critically Stressed Rough Rock Fracture: DECOVALEX-2023 Task G (임계응력 하 거친 암석 균열의 Thermoshearing 수치모델링: 국제공동연구 DECOVALEX-2023 Task G)

  • Jung-Wook Park;Chan-Hee Park;Li Zhuang;Jeoung Seok Yoon;Changlun Sun;Changsoo Lee
    • Tunnel and Underground Space
    • /
    • v.33 no.3
    • /
    • pp.189-207
    • /
    • 2023
  • In the present study, the thermoshearing experiment on a rough rock fracture were modeled using a three-dimensional grain-based distinct element model (GBDEM). The experiment was conducted by the Korea Institute of Construction Technology to investigate the progressive shear failure of fracture under the influence of thermal stress in a critical stress state. The numerical model employs an assembly of multiple polyhedral grains and their interfaces to represent the rock sample, and calculates the coupled thermo-mechanical behavior of the grains (blocks) and the interfaces (contacts) using 3DEC, a DEM code. The primary focus was on simulating the temperature evolution, generation of thermal stress, and shear and normal displacements of the fracture. Two fracture models, namely the mated fracture model and the unmated fracture model, were constructed based on the degree of surface matedness, and their respective behaviors were compared and analyzed. By leveraging the advantage of the DEM, the contact area between the fracture surfaces was continuously monitored during the simulation, enabling an examination of its influence on shear behavior. The numerical results demonstrated distinct differences depending on the degree of the surface matedness at the initial stage. In the mated fracture model, where the surfaces were in almost full contact, the characteristic stages of peak stress and residual stress commonly observed in shear behavior of natural rock joints were reasonably replicated, despite exhibiting discrepancies with the experimental results. The analysis of contact area variation over time confirmed that our numerical model effectively simulated the abrupt normal dilation and shear slip, stress softening phenomenon, and transition to the residual state that occur during the peak stress stage. The unmated fracture model, which closely resembled the experimental specimen, showed qualitative agreement with the experimental observations, including heat transfer characteristics, the progressive shear failure process induced by heating, and the increase in thermal stress. However, there were some mismatches between the numerical and experimental results regarding the onset of fracture slip and the magnitudes of fracture stress and displacement. This research was conducted as part of DECOVALEX-2023 Task G, and we expect the numerical model to be enhanced through continued collaboration with other research teams and validated in further studies.

A study on the effects of polymer core gate sizes on thickness shrinkage rate (폴리머코어 게이트 크기 변화가 두께 방향 수축률에 미치는 영향에 대한 연구)

  • Choi, Han-Sol;Jeong, Eui-Chul;Park, Jun-Soo;Kim, Mi-Ae;Chae, Bo-Hye;Kim, Sang-Yun;Kim, Yong-Dae;Yoon, Kyung-Hwan;Lee, Sung-Hee
    • Design & Manufacturing
    • /
    • v.14 no.1
    • /
    • pp.1-7
    • /
    • 2020
  • In this study, the variation of the shrinkage in the thickness direction of the molded parts according to the gate size of the polymer core fabricated through the 3D printer using the SLS method was studied. The polymer cores are laser sintered and the powder material is nylon base PA2200. The polymer cores have lower heat transfer rate and rigidity than the metal core due to the characteristics of the material. Therefore, the injection molding test conditions are set to minimize the deformation of the core during the injection process. The resin used in the injection molding test is a PP material. The packing condition was set to 80, 90 and 100% of the maximum injection pressure for each gate size. The runner diameter used was ∅3mm, and the gates were fabricated in semicircle shapes with cross sections 1, 2, and 3 ㎟, respectively. Thickness measurement was performed for 10 points at 2.5 mm intervals from the point 2.5 mm away from the gate, and the shrinkage to thickness was measured for each point. The shrinkage rate according to the gate size tends to decrease as the cross-sectional area decreases as the maximum injection pressure increases. The average thickness shrinkage rate was close to 0% when the packing pressure was 90% for the gate area of 1mm2. When the holding pressure was set to 100%, the shrinkage was found to decrease by 3% from the standard dimension due to the over-packing phenomenon. Therefore, the smaller the gate, the more closely the molded dimensions can be molded due to the high pressure generation. It was confirmed that precise packing process control is necessary because over-packing phenomenon may occur.