• Title/Summary/Keyword: Characteristic line

Search Result 1,636, Processing Time 0.035 seconds

The characteristic of leakage current of ZnO block varistor according to fault conditions of three-phase four-wire distribution system (3상 배전계통의 고장조건에 따른 산화아연 피뢰기 소자의 누설전류 특성)

  • Lee, B.H.;Choi, H.S.;Kang, S.M.;Park, K.Y.;Lee, S.B.;Oh, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.174-177
    • /
    • 2003
  • Kinds of most frequent faults happened on overhead distribution system are the single line-to-ground fault, the line-to-line fault and the two line-to-ground fault. Occasionally, the three line-to-ground fault and the disconnection of a wire are happened in severe conditions. In this study, the single line-to-ground fault, the line-to-line fault, two line-to-ground fault on three-phase four-wire overhead distribution system were experimentally simulated and characteristics of total leakage current of distribution arrester caused by these faults were investigated. Also, the changing aspect of total leakage current of distribution arrester caused by voltage variation was investigated. In a consequence, abnormal voltages caused by voltage variation, the line-to-line fault, the two line-to-ground fault have a little effect on total leakage current of ZnO arrester. But abnormal voltages caused by the single line-to-ground fault have an important effect on total leakage current of ZnO arrester.

  • PDF

A Study on the Characteristic of Variable Impedance Line using DGS (DGS를 이용한 가변 임피던스 선로 특성에 관한 연구)

  • Kim Young-Ju;Joung Myoung-Sub;Park Jun-Seok;Cho Hong-Goo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.1
    • /
    • pp.35-40
    • /
    • 2005
  • In this paper, we designed and fabricated the variable impedance line by using the DGS(Defected Ground Structure) which is useful in mounting the external lumped elements. Also we used a varactor diode as Control device stuff at the proposed variable impedance line. We are able to change the impedance of transmission line as varied the capacitance of varactor diode by adjusting DC bias. The impedance variation of the proposed DGS line is about maximum 70 Ω. We will study about the application of DAM(Direct antenna modulation) in the future work.

Surge Analysis Considering Variation of Line Configuration Factor in Combined Distribution Systems with Power Cables (혼합배전계통 선로구성요소 변화를 고려한 선로 서지해석)

  • Kim, Byong-Sook;Lee, Jang-Geun;Han, Byoung-Sung;Lee, Jong-Beom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.3
    • /
    • pp.472-480
    • /
    • 2007
  • This paper analyzes overvoltage on testing line for various parameter effect examination. Model systems consist of overhead line and underground cable. The model considered actual characteristic data of distribution lines. and will be constructed at testing yard. The simulations were performed under various line configuration such as cable kinds, cable length, lightning wave, lightning wave time, transformer and branch circuits. The simulation models are established by EMTP/ATPDraw and Line Constants are calculated by ATP_LCC. When lightning surge strikes on conductor of overhead line, EMTP/ATPDraw calculates overvoltage in many cases. Simulation results will be compared with real testing results at testing yard. The compared results will be used to establish protection methods in actual underground distribution systems.

On the Loci of the Input Reflection Coefficient of a Loaded Transmission Line on the Smith Chart (부하가 있는 전송 선로의 입력 반사 게수의 스미스 차트 상에서의 쾌적)

  • Eun, Chang-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.4A
    • /
    • pp.232-237
    • /
    • 2003
  • We present the derivation of the loci of the reflection coefficient of a loaded transmission line on the Smith chart as the length of the transmission line is varied. The results show that the loci constitute a circle when the characteristic impedance of the transmission line differs from the normalizing one, whose center and radius are determined by the impedances of the load and the transmission line. The results can be used in the matching circuit design using microstriplines when line width and length should be compromised.

A SIMPLE GRANULE MODEL AND ITS EFFECT ON SPECTRAL LINE ASYMMETRY

  • KIM YONGCHEOL
    • Journal of The Korean Astronomical Society
    • /
    • v.31 no.2
    • /
    • pp.77-87
    • /
    • 1998
  • The accumulated knowledge of the influence of solar granulation on spectral lines, i.e. their asymmetry, provides a key to analyze stellar spectral line asymmetries. In this paper, a simple line synthesis using a simple 'model' of granulation was calculated. By adjusting the properties of the granule model, the observed imprints of convection on spectral lines can be reproduced. Since we depict convective flows using a continuous function rather than using a few components of flows (cf. Gray and Toner 1985, 1986; dravins 1990), we were able to identify which components of convection are important in line bisector shapes. The results of this study can be summarized as follows: Firstly, the intensity contrast (i.e. temperature fluctuation), and the area coverage of up- and down-flows are the two important factors which determine the line bisector shapes. Secondly, on the contrary to the assumption of other studies, the effect of horizontal flows is non-negligible. This exercise provides a qualitative understanding of the effect of convection on spectral lines. This knowledge serves as a guideline for understanding the characteristic difference in convection for stars on either side of the 'Granulation Boundary' (Gray 1982; Gray and Nagel 1989).

  • PDF

Breeding of Korean Ginseng (Panax ginseng C. A. Meyer)

  • Kwang-Tae Choi;Woo
    • Proceedings of the Ginseng society Conference
    • /
    • 1998.06a
    • /
    • pp.96-102
    • /
    • 1998
  • A lot of individual ginseng plants were selected in the farmer's fields to develop new ginseng varieties with desirable traits. Among them, a promising line has been developed through comparative cultivation of several lines selected with pure line separation of local raced. It was then designated as "KC (denotes Korean Ginseng)" and tested in the regional yield and adaptation trials for 10 years. KG lines grew vigorously after 4 years of age. Especially, KG 102 line arson운 them showed traits of multiple and short stems. As for the root characters, the length of taproot of KG 101 line was longer than that of local race, Jakyung-jong, or other lines ailed the root weight of KG 102 line waIn 15 % higher than that of local race. In general, KG 101, KG 103, KG 104, and Hwangsauk-jong had good root shape. Total amount of ginsenosides of ginseng taproot was the highest in KG 103 line than in local race and other lines. In these studies, we, elected three superior lines, KG 101, KG 102, and KG 103, having characteristic of good root shape, high yield, and large amount of ginsenoside, respectively.

  • PDF

A Study on the Control of Solenoid Valve for Heating by using Power Line Communication (PLC) (전력선 통신을 이용한 난방용 솔레노이드밸브 제어에 관한 연구)

  • 신관우;김용태;이윤섭
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.8
    • /
    • pp.647-650
    • /
    • 2003
  • PLC (Power Line Communication) is the communication method using the existing power line installed in houses and offices to convert and transmit high frequency communication signal from tens of KHz to tens of MHz, and receive the filtered signal using high frequency filter The advantage of PLC is that PLC uses the existing power line installed in houses and offices so it does not require separate power line. Easy and convenient access using electric outlets is another advantage of PLC. However, PLC has some disadvantages such as limited transmission power, high load interference and noise, variable signal attenuation, characteristic of impedance, and selective possibility of frequency property. We designed the boiler temperature control system unit by using the PLC modem. We can avoid unnecessary heating of separate temperature control unit, and save the cost accordingly control stability of the proposed system is proven through the experiment.

A Study on Geothermal Characteristics of Dam Body and Seepage Flow (댐 제체 및 침투수 흐름의 지열학적 고찰)

  • Park, Dong-Soon;Jung, Woo-Sung;Kim, Hyoung-Soo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.75-85
    • /
    • 2006
  • In recent geotechnical engineering, geothermal approach has been on the horizon to deal with geoenvironmental issues, freezing and thawing problems, and seepage phenomenon in dams and embankments. In this study, geothermal characteristic through inner body of dams and its influence on the seepage flow were experimented by lab test and field instrumentation. Also, one of up-to-date temperature monitoring technique, called as multi-channel thermal line sensing, was evaluated its availability. As a result of lab test, it is found that the seepage flow has influence on the geothermal characteristic and a potential of finding phreatic line and seepage fluctuation could be possible by continuous temperature monitoring using thermal line sensing skills. These kine of geothermal information could be available to the modelling of water geo-structure interaction. Out of short-term field tests, clear water table and temperature distribution of a dam were easily found through temperature monitoring in holes located near a reservoir and holes within a depth of constant temperature layer. However, it is also found that the geothermal flow and finding seepage line could not be easily understandable through multi-channel temperature monitoring because of the existence of constant temperature field, thermal conductivity of soils and rocks, and unsaturated characteristics of geo-material. In this case, long-term geothermal monitoring is recommended to find sudden fluctuation of seepage line and amount of leakage.

  • PDF

Input Impedance Calculation of the Power Line Communication System (전력선 통신 시스템의 입력 임피던스 계산)

  • Chun, Dong-wan;Lee, Jin-taek;Park, Young-Jin;Kim, Kwan-Ho;Shin, Chull-Chai
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.9A
    • /
    • pp.983-990
    • /
    • 2004
  • In this paper, we calculated the input impedance of the power line communication(PLC) networks using medium voltage power line. First of all, we proposed input and output teoninal model of PLC network, and calculated the input impedance applying the attenuation constants by radiation loss, conductor loss, dielectric loss. From the calculation result, we knew that the attenuation by radiation loss was largest, and the input impedance appears like a standing wave fonn with a fixed cycle because the high reflection at the input terminal for the characteristic impedance of the power line is very large. And also the cycle of input impedance depends on the coaxial cable length, and the amplitude depends on the characteristic impedance of power line and losses. From the measurement result, calculated result was very similar to the measured result.

Electric Fuel Sender Apparatus for the Vehicles Using CPW Transmission Line (CPW 전송선을 이용한 전자식 자동차용 연료 센더 장치)

  • Son Tae-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.4 s.107
    • /
    • pp.380-386
    • /
    • 2006
  • Electric fuel sender fur the vehicle fuel gauge system was designed and fabricated based on the CPW(Co-Planer Waveguide) transmission line theory. It is applied on this system that characteristic impedance of RF transmission line can be varied by the surrounded material of the line. By the characteristic impedance owing the level of gasoline or diesel fuel in vehicle fuel tank, CPW line has corresponding reflected signal as much as changed impedance. Detected signal is amplified, and delivered to fuel indicator into cluster unit on dash board. Conventional floating mechanical buoy level gauge has several defects as low reliability and high break down rate by mechanical operation, and has not good linearity for the fuel level difference. CPW line with electric circuits are constructed on 1.6 mm thickness epoxy substrate, and measurement shows that this system has more accurate level and better linearity than conventional mechanical system. New electric fuel sender which has good productivity with long lifetime and low-in-cost by the SMT chip assembling could be replaced this system with conventional floating buoy system.