• Title/Summary/Keyword: Characteristic Pressure

Search Result 1,810, Processing Time 0.031 seconds

Effects of the Geometry of Components Attached to the Drain Valve on the Performance of Water Hammer Pumps

  • Saito, Sumio;Takahashi, Masaaki;Nagata, Yoshimi;Dejima, Keita
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.4
    • /
    • pp.367-374
    • /
    • 2011
  • Water hammer pumps can effectively use the water hammer phenomenon in long-distance pipeline networks that include pumps and allow fluid transport without drive sources, such as electric motors. The results of experiments that examined the effect of the geometric form of water hammer pumps by considering their major dimensions have been reported. In addition, a paper has also been published analyzing the water hammer phenomenon numerically by using the characteristic curve method for comparison with experimental results. However, these conventional studies have not fully evaluated the pump performance in terms of pump head and flow rate, common measures indicating the performance of pumps. Therefore, as a first stage for the understanding of water hammer pump performance in comparison with the characteristics of typical turbo pumps, the previous paper experimentally examined how the hydrodynamic characteristics were affected by the inner diameter ratio of the drive and lifting pipes, the form of the air chamber, and the angle of the drive pipe. To understand the behavior of the components attached to the valve chamber and the air chamber that affects the performance of water hammer pumps, the previous study also determined the relationship between the water hammer pump performance and temporal changes in valve chamber and air chamber pressures according to the air chamber capacity. For the geometry of components attached to the drain valve, which is another major component of water hammer pumps, this study experimentally examines how the water hammer pump performance is affected by the length of the spring and the angle of the drain pipe.

Dry Etching of $Al_2O_3$ Thin Film in Inductively Coupled Plasma

  • Xue, Yang;Um, Doo-Seung;Kim, Chang-Il
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.67-67
    • /
    • 2009
  • Due to the scaling down of the dielectrics thickness, the leakage currents arising from electron tunneling through the dielectrics has become the major technical barrier. Thus, much works has focused on the development of high k dielectrics in both cases of memories and CMOS fields. Among the high-k materials, $Al_2O_3$ considered as good candidate has been attracting much attentions, which own some good properties as high dielectric constant k value (~9), a high bandgap (~2eV) and elevated crystallization temperature, etc. Due to the easy control of ion energy and flux, low ownership and simple structure of the inductively coupled plasma (ICP), we chose it for high-density plasma in our study. And the $BCl_3$ was included in the gas due to the effective extraction of oxygen in the form of BClxOy compound. In this study, the etch characteristic of ALD deposited $Al_2O_3$ thin film was investigated in $BCl_3/N_2$ plasma. The experiment were performed by comparing etch rates and selectivity of $Al_2O_3$ over $SiO_2$ as functions of the input plasma parameters such as gas mixing ratio, DC-bias voltage and RF power and process pressure. The maximum etch rate was obtained under 15 mTorr process perssure, 700 W RF power, $BCl_3$(6 sccm)/$N_2$(14 sccm) plasma, and the highest etch selectivity was 1.9. We used the x-ray photoelectron spectroscopy (XPS) to investigate the chemical reactions on the etched surface. The Auger electron spectroscopy (AES) was used for elemental analysis of etched surface.

  • PDF

A study on the hearing characteristic based equalizer design for the elderly (고령층의 가청주파수 특성을 고려한 이퀄라이저 연구)

  • Lee, Chul-Hee;Hong, Sung-Kyoo
    • Journal of Digital Contents Society
    • /
    • v.19 no.4
    • /
    • pp.779-787
    • /
    • 2018
  • This study delves into how the equalizer can compensate for a sound pressure of lost frequencies. The targeted audiences are senior citizens who have difficulties hearing high-frequency because of a decline of audio frequency. Through investigations, this study confirms that the reason why reduction of high-frequency hearing increases depending on senescence. By considering the features of audio frequency of senior citizens, it also clarifies the necessity of equalizer reflecting features of audio frequency for the senior citizens, which have dramatically increased in Korea. There are application programs having functions, which provide several options of equalizer setup that people can adjust it depending on their own audio frequency. Some of them provide different equalizer setup depending on age. This study, however, reveals that they are not fully enough to compensate for the range of hearing loss of the senior citizens. Therefore, by pointing out limitations of existing functions and suggesting improvements, this study explores the way of improvements that enhance the sound transmissions of digital media contents for senior citizens.

Pre-Coagulation and Pre-Ozonation for Ozone Resisting Microfiltration Membrane Filtration System of a High Humic Contained Surface Water (고농도 휴믹성분이 포함된 강 원수에서 응집-침전 및 오존 공정을 전처리로 적용한 오존 내성막 pilot plant에서의 운전성 및 투과수 수질변화에 관한 연구)

  • Lee, Sanghyup;Yoshimasa, Watanabe;Lee, Seockheun;Ahn, Kyuhong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.5
    • /
    • pp.598-607
    • /
    • 2004
  • In this study, the effects of two pre-treatment processes were observed prior to membrane filtration: pre-coagulation and pre-ozonation. To compare the effect of two above-mentioned pre-treatments, we adopted the four schemes: first one is direct membrane filtration of river surface water, second one is membrane filtration after pre-coagulation, third one is membrane filtration after pre-ozonation and fourth one is membrane filtration after pre-coagulation and pre-ozonation. There are two exceptional characteristics in applied processes. One is the usage of the MF membrane which has high ozone resisting characteristic. Therefore, ozone resides in membrane module during filtration. The other is adoption of Jet Mixed Separator (JMS) as coagulation-sedimentation process. The change in transmembrane pressure and permeate water quality were also examined. As a result, considering the filtration performance efficiency and permeate water quality, the process composed of filtration with combination of both pre-coagulation and pre-ozonation was proved most effective. The improved efficiency was due to the reduction of loading rate of fouling inducing materials to membrane module by coagulation process as well as variable reactions, such as degradation, particle destabilization and coagulation, occurred by residual ozone in membrane module. The additional effect of pre-coagulation before pre-ozonation is suppression of AOC, one of the by-products induced by ozonation. Therefore, combination of pre-coagulation and pre-ozonation is the effective process to overcome the major de-merit of ozonation i.e. by-products formation.

Comparison of Epidemiology and Outcomes of Patients with Intentional Poisoning by Age Groups: Single Center Observation Study (의도적 중독으로 응급센터에 내원한 환자에 대한 연령별 비교 분석)

  • Kim, Jin Hyun;Cho, Jin Seong;Kim, Jin Joo;Lim, Yong Su;Yang, Hyuk Jun;Lee, Geun
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.14 no.2
    • /
    • pp.129-135
    • /
    • 2016
  • Purpose: This study was conducted to compare demographic and characteristic differences in self-poisoned patients by age groups using a comprehensive trauma database. Methods: This study included 1,823 patients who were admitted to the emergency room following self-poisoning. Three age groups were defined: young patients (less than 19 years), adult patients (19 to 64 years) and elderly patients (65 years and old). From January 2011 to December 2015, data were obtained from in a single emergency medical center. We investigated the materials of poisoning, ingestion time, GCS, systolic blood pressure, heart rate, and outcomes of patients. Results: A total of 1,823 self-poisoned patients visited the hospital during 5 years. Among these, 130 (7.1%) were categorized as young, 1,460 (80.1%) were adults and 233 (12.8%) were elderly. The most common drug of self-poisoning substances was antipyretics (50.0%) for those in the young group, sedative drugs (45.0%) for adults, and pesticides (41.2%) for the elderly. Mortality was 2.7% in the adult group and 14.6% in the elderly group. After adjusting for all factors related to mortality, the odds ratio (OR) of mortality was 2.63 in the elderly group (95% confidence interval [CI]: 1.44-4.81). Conclusion: There were definite differences in the characteristics of three groups. The younger patients used drugs that could be easily obtained while older patients used more lethal drugs.

Analysis of Two-Dimensional Flow around Blades with Large Deflection in Axial Turbomachine (전향도가 큰 축류터보기계의 블레이드 주위의 유동해석)

  • 원승호;손병진;최상경
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.1
    • /
    • pp.229-240
    • /
    • 1991
  • The large camber angle theory of turbomachine blade of compressor has been developed recently for the two-dimensional flow by Hawthorn, et al. However, in the above theory it was assumed that the fluid was incompressible and inviscid, and the blades had no thickness. In this study, the flow in a blade cascade being mounted in parallel fashion with blade of arbitrary thickness is studied in order to determine the effects of the camber angle on the performance characteristic of the blade section under the consideration of compressibility and viscosity of fluid. The panel method is used for potential flow analysis. The flow in the boundary-layer is obtained by solving the integral boundary-layer structure through the laminar, transitional , and turbulent flow using the pressure field determined from the potential flow. And then the viscous-inviscid interaction scheme is used for interaction of these two flows. For the determination of the variation in the outlet fluid angle influenced by deviation in cascade flow, the superposition method which is used for single foil is introduced in this analysis. By the introduction of this method, the effects of the deviation on outlet fluid angle and the resulting fluid angle are made to adjust for oneself through the calculation. As the result of this study, the blade of large camber angle, large incidence angle, large pitch-chord ratio has large viscous and compressible effect than those of small camber angle. Lift force increase as camber angle increases, but above 60.deg. of camber angle, lift force decrease as camber angle increases. But drag force increases linearly with camber angle increases in the entire region.

A Study on PIV Measurement of Unsteady Flow around Disk caused by Slide Type Valve Quick Closing (슬라이드 밸브 급폐쇄에 따른 디스크 주위 비정상유동의 PIV계측에 관한 연구)

  • Lee, Chul-Jae;Cho, Dae-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.15 no.3
    • /
    • pp.251-256
    • /
    • 2009
  • In this research, we experimentally studied flow characteristic by applying PIV measuring techniques which could measure the point velocity of all flow field and measuring the unsteady velocity of surrounding disk generated in a short time. Time range of great velocity change following quick closing of the slide valve was within 0.1s and the cycle was presumed to be 0.12s as a result of comparison study between the result of point flow field and of existing pressure change. Also, surrounding disk flow inside the circular pipe was closed from the upper part and flow road was getting narrow and advanced to the lower part incidentally quickly there was a tendency that the size of the flow back velocity to the upper part immeadiately after the closure decreased to 4/120s and increased again. There was flow back velocity component in y/D=0.2 lower part by the influence of flow back to the upper part after complete closure and the vortex flow of 0.2D-size near y/D=0.7, x/D=-0.3 was observed.

  • PDF

Etching Property of the TaN Thin Film using an Inductively Coupled Plasma (유도결합플라즈마를 이용한 TaN 박막의 식각 특성)

  • Um, Doo-Seung;Woo, Jong-Chang;Kim, Dong-Pyo;Kim, Chang-Il
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.104-104
    • /
    • 2009
  • Critical dimensions has rapidly shrunk to increase the degree of integration and to reduce the power consumption. However, it is accompanied with several problems like direct tunneling through the gate insulator layer and the low conductivity characteristic of poly-silicon. To cover these faults, the study of new materials is urgently needed. Recently, high dielectric materials like $Al_2O_3$, $ZrO_2$ and $HfO_2$ are being studied for equivalent oxide thickness (EOT). However, poly-silicon gate is not compatible with high-k materials for gate-insulator. To integrate high-k gate dielectric materials in nano-scale devices, metal gate electrodes are expected to be used in the future. Currently, metal gate electrode materials like TiN, TaN, and WN are being widely studied for next-generation nano-scale devices. The TaN gate electrode for metal/high-k gate stack is compatible with high-k materials. According to this trend, the study about dry etching technology of the TaN film is needed. In this study, we investigated the etch mechanism of the TaN thin film in an inductively coupled plasma (ICP) system with $O_2/BCl_3/Ar$ gas chemistry. The etch rates and selectivities of TaN thin films were investigated in terms of the gas mixing ratio, the RF power, the DC-bias voltage, and the process pressure. The characteristics of the plasma were estimated using optical emission spectroscopy (OES). The surface reactions after etching were investigated using X-ray photoelectron spectroscopy (XPS) and auger electron spectroscopy (AES).

  • PDF

The Characteristic for Undrainded Shear Behavior of in Low-Plastic Silt and its Prediction (저소성 실트의 비배수 전단거동 특성과 예측)

  • Kim, Daeman
    • Journal of the Korean GEO-environmental Society
    • /
    • v.9 no.6
    • /
    • pp.61-70
    • /
    • 2008
  • In this study, undrained triaxial (CU) tests were performed on low-plastic silt of Nakdong River in order to investigate the undrained shear behavior of low-plastic silt. In experimental results, the deviator stress showed the hardening behavior after reaching its yield stress like the tendency of common sand, and the pore water pressure was gradually decreased to critical state after the maximum value. In the effective stress paths, regardless of consolidation stress or overconsolidation ratios, both a critical state line (CSL) and a phase transformation line (PTL) exist in the effective stress path that is similar to the case of sand. The behavior of low-plastic silt was predicted by the Modified Cam-Clay (MCC) model, the Jordan and the Elman-jordan model that is artificial neural network model. According to predicted results, the overall undrained shear behavior of low-plastic silt could not be predicted with the MCC model, but the Jordan and Elman-Jordan model showed well-matched experiment results.

  • PDF

A Study on Photosensitization Mechanism of Phthalocyanines with LB Films (LB박막을 이용한 프탈로시아닌의 광증감 기구에 관한 연구)

  • Kim, Bum Goo;Kim, Young Soon
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.1
    • /
    • pp.58-68
    • /
    • 1999
  • The phthalocyanine(Pc) film can not be prepared by LB method because it is insoluble in organic solvents. In order to increase its solubility, two kinds of copper phthalocyanine derivatives (CuPc$(COOH)_2$ and CuPc$(COOH)_4$) were synthesized and their monolayers were prepared by LB method. It is found from the surface pressure-area curves that the LB monolayer film of CuPc$(COOH)_2$ have more ordered structure than that of CuPc$(COOH)_4$. In the photocurrent characteristic the value Of CuPc$(COOH)_2$ was superior to that of CuPc $(COOH)_4$. Therefore, it is found that the charge generation efficiency for phthalocyanines have influenced on its ordered structure as the functional groups.

  • PDF