• Title/Summary/Keyword: Channel Variation

Search Result 799, Processing Time 0.025 seconds

Experimental Study on the Effect of Tip Clearance of a Centrifugal Compressor (팁 간극 영향으로 인한 원심 압축기 성능특성 시험연구)

  • Cha, Bongjun;Lim, Byungjun;Yang, Sooseok;Lee, Daesung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.4 no.1 s.10
    • /
    • pp.30-37
    • /
    • 2001
  • The experimental study on the effect of axial clearance between the tip of impeller blades and stationary shroud has been performed. The investigated compressor, which is a part of a small auxiliary power unit engine, consists of a curved inlet, a centrifugal impeller, a channel diffuser and a plenum chamber. It was designed for a total pressure ratio of 4.3 and an efficiency of $77\%$ at design speed of 60,000 rpm. The experiments are carried out in an open-loop centrifugal compressor test rig driven by a turbine. For the four different clearance ratios Cr(clearance/impeller tip width) of 6.25, 10.93, 15.60 and 20.30 percent, the overall performance data are obtained at $97\%,\;90\%$ and $80\%$ of the design speed. The results show the overall pressure ratio decrease of $7.7\%$ and the efficiency loss of $8.7\%$ across the variation of clearance ratio near the design speed. It also indicates that the influence of tip clearance became weaker as the flow rate is reduced and the stable operating range is not significantly influenced by the change of clearance ratio.

  • PDF

Simple and Multigrid Models for Hydraulic Study on Coffering a Tide Embankment (방조제 체절 수리 검토를 위한 단순 모형과 다중격자 모형)

  • 이정렬;고진석;이태환
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.13 no.4
    • /
    • pp.309-318
    • /
    • 2001
  • A zero-dimensional simple model is presented to predict the currents in the opening channel of tide embankment and the sea-level response of the interior basin to ocean sea level. In general, a tidal embayment has wide tidal flats so that the effect of tidal flats has been taken into account by formulating the volute variation vs. depth. The model has been verified through the comparison with the 2-dimensional depth-integrated model which can resolve the small area by using the multigrid method. As the results applied to the storage of dredged material of Incheon North Harbour, the results indicate that both models adequately describe the sea-level and current fluctuations in the storage.

  • PDF

Experimental Analysis on the Behavior of Alternate Bars in a Channel with a Spur Dike (수제의 길이 변화에 의한 교호사주의 거동 분석 실험)

  • Jang, Chang-Lae;Song, Youngjin
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.1
    • /
    • pp.8-13
    • /
    • 2016
  • This study investigated the effects of a spur dike on the development processes, the migration, and the wave length of alternate bars with laboratory experiments. The bar wave length was shown to be shorter as the spur dikes got longer. The forcing effects of a long spur dike on the behavior of alternate bars were stronger than those of a shorter one. However, the bar height was not affected by the variation of the length of a spur dike. The bar migration speed was in inverse proportion to the bar wave length.

Variation of Bed Elevation by Installing a Pier near Channel Junction (합류부 부근 교각설치에 따른 하상변화에 관한 연구)

  • Choi Gye Woon;Kim Young Kyu;Byeon Seong June;Chung Youn Joong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1143-1147
    • /
    • 2005
  • 인간생활을 하면서 하천을 건너다니기 위해 많은 교량을 설치하여 이용하고 있으며, 현재도 어느 지역 언 하천에선가 교량을 건설 중에 있다. 이러한 교량을 설치할 때 교량의 교각을 설치하는 위치는 경제성이나 구조의 설계 안전성에 의해 노선을 결정하고 설치하고 있다. 물론 하천설계기준이나 도로설계요령에 의하면 설치기준이나 세굴 등에 대한 고려사항을 제시하고 있고 이를 맞추기 위해 노력하고 있다. 그러나 이러한 설계기준에서의 제안은 대부분 일반 직선하천에서 구해진 공식이나 경험에 의해 나타내어진 값이다. 따라서 수리현상이 불규칙적이고 복잡한 합류부에 적용하기에는 다소 역부족이다. 본 실험 연구에서는 합류부를 지닌 하천에서의 교각 설치 위치에 따른 세굴의 영향 및 합류각도에 따른 영향을 분석하기 위해 수리실험을 통해 결과를 도출하고자 하였으며, 그 결과 합류되는 각도에 따라 교각의 최대세굴심이 큰 차이를 나타내고 있으나, 합류부를 지닌 수로에서의 세굴심은 유속이 가장 빠른 곳에서 최대세굴심이 나타나지 않으며 유속보다 접근각도 및 흐름에 의한 하향류에 의해 영향을 받기 때문에 기존의 공식에 의해 계산할 수 없으며 실험을 통한 계산을 하거나 가급적 하천의 중앙부에 설치하는 것을 피해야 할 것으로 판단된다.

  • PDF

TEMPORAL AND SPA TIAL VARIATION OF NIGHTTIME FISHING GROUND DERIVED FROM SATELLITE IMAGERY

  • Kim Sang-Woo;Jeong Hee-Dong;Suh Young-Sang;Go Woo Jin;Jang Lee-Hyun
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.437-440
    • /
    • 2005
  • We examined the relationship between the 50m temperature estimated by remote sensing sea surface temperature (SST) and fishing ground (squid fishing ground) detected by nighttime visible channel defense meteorological satellite program (DMSP) I operational linescan system (OLS) images in the East/Japan Sea during 1993-2000. The results are as follows: The numbers of nighttime fishing boat were distributed the highest in October, and the lowest in April during this study. A nighttime fishing grounds have concentrated in the East Korea Warm Current region, coastal regions of Honshu Island, and Polar front region. Fishing grounds have distributed $11-18^{\circ}C$ of estimated 50m temperature from the satellite data. Relationship between estimated 50m temperature and the distributed fisheries boats showed that the north boundaries of fishing grounds have distributed the temperature of below $12^{\circ}C$ from 1996 to 2000 and that of $13-15^{\circ}C$ during 1993-1995 and 1997-1999. Stable fishing grounds appeared near the Korea/Tsushima Strait from January to March. The center of fishing grounds in spring (April-Jun) have moved to the northward than that in winter, and variations appeared largely in winter. In summer (July-September), center of fishing grounds have formed near the Uleung Island in the south east coast of Korea, and in autumn maximum fishing ground appeared in October, the fishing ground southward from November.

  • PDF

Variable Iteration Decoding Control Method for Iteration Codes (Iteration 부호의 가변반복복호 제어기법)

  • 백승재;이성우;박진수
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.753-757
    • /
    • 2003
  • In this paper, We propose an efficient iteration decoding control method with variable iteration decoding for iteration codes decoding. As the number of iterations increases, the bit error rate and frame error rate of the decoder decrease and the incremental improvement gradually diminishes. However, as the iteration decoding number is increase, it require much delay and amount of processing for decoding. Thus we propose variable iteration control method to adapt variation of channel using Frame Error-Check indicator. Therefore, the CRC method requires the fewest iterations and less computation than the CE method and the SCR methods.

  • PDF

Error Rate Performance of FH/MFSK Signal with Thermal Noise in the Partial Band Jamming Environments (부분대역 재밍 환경하에서 열잡음을 고려한 FH/MFSK 신호의 오솔특성)

  • 강찬석;안중수
    • The Journal of the Acoustical Society of Korea
    • /
    • v.12 no.1
    • /
    • pp.47-54
    • /
    • 1993
  • Performance analysis is very important to transmit the high quality information and to construct the optimal system for the minimze the noise from the channel of spread spectrum system. In this paper the error rate performance is analyzed with computer simulation in noncoherent frequency hopping M-qry frequency shift keying(FH/MFSk) systems with regard to thermal noise under the partial band jamming environments. AS a result, in case the thermal noise is disregarded, bit error probability of system in jamming fraction ρ and Eb/Nj(bit energy to jamming power density) is reduced with the increase of K and in worst case 32FSK system is better than 2FSK system by 3.23dB with the variatio of Eb/Nj. In case thermal noise is considered, bit error probability of system by 3.23dB with the variation of Eb/Nj. In case thermal noise is considered, bit error probability of system are reduced with the increase of K and Eb/No(bit energy to thermal noise density). Bit error probability in connection with worst case ρ is not largely influenced form over the 14dB to K=1 and 8dB to K=5 accordingly thermal noise disregarding. These results may be useful for avoiding the common vulnerabilities when the spread spectrum system is designed.

  • PDF

A study on the characteristics of heat transfer and pressure drop in plate type evaporator with U-turn for automotive air conditioner (유턴 흐름을 갖는 차량공조용 플레이트형 증발기의 전열특성에 관한 연구)

  • 강정길;김종수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.4
    • /
    • pp.472-483
    • /
    • 1999
  • The evaporation heat transfer and pressure drop characteristics for HFC-l34a in flat plate type heat exchangers with enhanced beads were experimentally investigated. Three plate type evaporators with different geometric condition of U-turn area were tested. Mass fluxes were tested over the range of 83kg/$m^2$s to 166kg/$m^2$s, and heat fluxes were varied from 4㎾/$m^2$ to 12㎾/$m^2$. Evaporation temperature was 5$^{\circ}C$ with inlet qualities of 0.1 to 1.0. There was no notable difference in the heat transfer coefficient by geometric variation of U-turn area, but the third plate with cross-ribbed channel at U-turn area was better than others in the evaluation using volume goodness factor comparison. Also, the mixtures of HFC-l34a and PAG oil was tested to determine oil effects on heat transfer and pressure drop. As oil concentration was increased, heat transfer coefficient was increased by 22~48% up to the 3wt.%, but decreased by 14~22% at the 4wt.%. The pressure drop was increased by the maximum of 100% as oil concentration was increased.

  • PDF

COMPARISONS OF MTSAT-1R INFRARED CHANNEL MEASUREMENTS WITH MODIS/TERRA

  • Han, Hyo-Jin;Sohn, Byung-Ju;Park, Hye-Suk
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.651-654
    • /
    • 2006
  • Infrared channels of newly launched Japanese geostationary satellite, MTSAT-1R are compared with well calibrated MODIS/Terra infrared measurements at 3.7, 6.7, 11, 12 ${\mu}m$ bands. There are four steps in this intercalibration method: 1) data collection, 2) spectral response function correction, 3) data collocation, and 4) calculation of mean bias and conversion coefficients. In order to minimize the navigation error of MTSAT-1R, comparisons are made over the area in which the viewing angle of MTSAT-1R is less than 50$^{\circ}$. The calibration method was tested for August 2005 and within the 40$^{\circ}N$-40$^{\circ}S$, 100$^{\circ}$E-180$^{\circ}$E domain. The differences of spectral response functions were corrected through radiative transfer model simulation. Constructing collocated data differences in viewing geometry, observation time and space were taken into account. In order to avoid the radiance variation induced by cloud presence, clear-sky targets are selected as intercalibration target. The mean biases of 11, 12, 6.7, and 3.7 ${\mu}m$ bands are about -0.16, 0.36, 1.31, and -6.69 K, suggesting that accuracies of 3.7 ${\mu}m$ is questionable while other channels are comparable to MODIS

  • PDF

A Study on Performance of Thermoelectric Air-Cooling System in Parallel Flow (평행유동에서 공랭식 열전모듈 냉각시스템의 성능에 관한 연구)

  • Karng, Sarng-Woo;Shin, Jae-Hoon;Han, Hun-Sik;Kim, Seo-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.6
    • /
    • pp.421-429
    • /
    • 2011
  • Experimental and theoretical studies on cooling performance of two-channel thermoelectric air-cooling system in parallel flow are conducted. The effects of operating temperature to physical properties of thermoelectric module (TEM) are experimentally examined and used in the analysis of an air-cooling system considering thermal network and energy balance. The theoretical predicted temperature variation and cooling capacity are in good agreement with measured data, thereby validating analytic model. The heat absorbed rate increases with increasing the voltage input and decreasing thermal resistance of the system. The power consumption of TEM is linearly proportional to mean temperature differences due to variations of the physical properties on operation temperature of TEM. Furthermore thermal resistance of hot side has greater effects on cooling performance than that of cold side.