• Title/Summary/Keyword: Channel Variation

Search Result 799, Processing Time 0.031 seconds

Longitudinal Pattern of Large Wood Distribution in Mountain Streams (산지계류에 있어서 유목의 종단적 분포특성)

  • Seo, Jung Il;Chun, Kun Woo;Kim, Min Sik;Yeom, Kyu Jin;Lee, Jin Ho;Kimura, Masanobu
    • Journal of Korean Society of Forest Science
    • /
    • v.100 no.1
    • /
    • pp.52-61
    • /
    • 2011
  • Whereas recent researches have elucidated the positive ecological roles of large wood (LW) in fishbearing channels, LW is also recognized as a negative factor of log-laden debris flows and floods in densely populated areas. However in Republic of Korea, no study has investigated longitudinal variations of LW distribution and dynamic along the stream corridor. Hence to elucidate 1) physical factors controlling longitudinal distribution of LW and 2) their effect on variation in LW load amount, we surveyed the amount of LW with respect to channel morphology in a mountain stream, originated from Mt. Ki-ryong in Inje, Gangwondo. Model selection in the Generalized Linear Model procedure revealed that number of boulder (greater than or equal to 1.0 m in diameter), bankfull channel width and their interaction were the best predictors explaining LW load volume per unit channel segment area (unit LW load). In general, boulders scattered within small mountain streams influence LW retention as flow obstructions. However, in this study, we found that the effect of the boulders vary with the channel width; that is, whereas the unit LW load in the segment with narrow channel width increased continuously with increasing boulder number, it in the segment with wide channel width did not depend on the boulder number. This should be because that, in two channels having different widths, the rates of channel widths reduced by boulders are different although boulder numbers are same. Our findings on LW load varying with physical factors (i.e., interaction of boulder number and channel width) along the stream corridor suggest understanding for longitudinal continuum of hydrogeomorphic and ecologic characteristics in stream environments, and these should be carefully applied into the erosion control works for systematic watershed management and subsequent disaster prevention.

Remote field Eddy Current Technique Development for Gap Measurement of Neighboring Tubes of Nuclear Fuel Channel in Pressurized Heavy Water Reactor (중수로 핵연료채널과 인접관의 간격측정을 위한 원거리장 와전류검사 기술개발)

  • Jung, H.K.;Lee, D.H.;Lee, Y.S.;Huh, H;Cheong, Y.M.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.2
    • /
    • pp.164-170
    • /
    • 2004
  • Liquid Injection Nozzle(LIN) tube and Calandria tube(CT) in pressurized Heavy Water Reactor (PHWR) are .ross-aligned horizontally. These neighboring tubes can contact each other due to the sag of the calandria tube resulting from the irradiation creep and thermal creep, and fuel load, etc. In order to judge the contact which might be the safety concern, the remote field eddy current (RFEC) technology is applied for the gap measurement in this paper. LIN can be detected by inserting the RFEC probe into pressure tube (PT) at the crossing point directly. To obtain the optimal conditions of the RFEC inspection, the sensitivity, penetration and noise signals are considered simultaneously. The optimal frequency and coil spacing are 1kHz and 200mm respectively. Possible noises during LIN signal acquisition are caused by lift-off, PT thickness variation, and gap variation between PT and CT. The simulated noise signals were investigated by the Volume Integral Method(VIM). Signal analysis on the voltage plane describes the amplitude and shape of LIN and possible defects at several frequencies. All the RFEC measurements in the laboratory were done in variance with the CT/LIN gap and showed the relationship between the LIN gap and the signal parameters by analyzing the voltage plane signals.

Applicability of the Multi-Channel Surface-soil CO2-concentration Monitoring (SCM) System as a Surface Soil CO2 Monitoring Tool (다채널 지표토양 CO2 농도 모니터링(SCM) 시스템 개발 및 적용성 평가 연구)

  • Sung, Ki-Sung;Yu, Soonyoung;Choi, Byoung-Young;Park, Jinyoung;Han, Raehee;Kim, Jeong-Chan;Park, Kwon Gyu;Chae, Gitak
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.1
    • /
    • pp.41-55
    • /
    • 2015
  • Monitoring of $CO_2$ release through the ground surface is essential to confirm the safety of carbon storage projects. We conducted a feasibility study of the multi-channel surface-soil $CO_2$-concentration monitoring (SCM) system as a soil $CO_2$ monitoring tool with a small scale injection test. The background concentrations showed the distinct diurnal variation. The negative relation of $CO_2$ with temperature and the low $CO_2$ concentrations during the day imply that surface-soil $CO_2$ depends on photosynthesis and respiration. After 4.2 kg of $CO_2$ injection (1 m depth for 29 minutes), surface-soil $CO_2$ concentrations increased in the all five chambers, which were located less than 2.8 m of distance from each other. The $CO_2$ concentrations seem to be recovered to the background around 4 hours after the injection ended. To determine the leakage, the data from Chamber 2 and 5 with low increase rates were used for statistical analyses. Coefficient of variation for 30 minutes ($CV_{30min}$.) is efficient to determine a leakage signal, with reflecting the fast change in $CO_2$ concentrations. Consequently, SCM and $CV_{30min}$ could be applied for an efficient monitoring tool to detect $CO_2$ release through the ground surface. Also, this study provides ideas for establishing action steps after leakage detection.

Structure and Dynamics of the Cold Water in the Western Channel of the Korea Strait (대한해협 서수도 냉수의 구조와 역학)

  • Cho, Yang-Ki;Kim, Kuh;Kim, Young-Gyu
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.9 no.3
    • /
    • pp.132-139
    • /
    • 1997
  • CTD and current observation were taken to investigate the structure of the cold water in the Western Channel of the Korea Strait in October 1993. Thickness of the cold water in the deep trough of the strait changes from 20 m to 70 m according to the water depth. Thermocline between the Tsushima Warm Water and the cold water deepens from north to south with 0.00057 in slope. Temporal variation of the thickness appears to be related with the tidal current. The maximum variation is 20 m for 48 hours. Mean velocity of the cold water for 72 hours is 17 cm/sec southward. A simple model was used to understand dynamically the southward flow of the cold water and the return flow at the upper part in the lower layer. Calculated maximum southward flow and eddy viscosity coefficient are 7 cm/sec and 0.038 $m^2$/sec respectively in the model. Southward transport is $0.032$\times$10^6㎥/sec$ at the northern part in the trough and decreases from north to south due to the presence of the return flow. Southward transport increases with the increase in the upper layer transport but is not affected by the density of the upper layer or the interface slope.

  • PDF

Correlation Between the Headphone's Acoustical Characteristics and Subjective Preferences (헤드폰의 음향적 특성과 주관적 선호도간의 상관 관계)

  • Lee, Ki-Seung;Lee, Seok-Pil
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.2
    • /
    • pp.96-106
    • /
    • 2009
  • In this paper, correlation between the headphone's acoustical characteristics and the subjective preferences is analyzed, and a possibility of predicting the subjective preferences using the acoustical characteristics is investigated, The headphone's acoustical characteristics include the total harmonic distortions, the variation of the frequency response which were measured by separate channel and the inter-aural correlation coefficients, Those characteristics were measured in a noise-free anechoic chamber, using a head and torso simulator, The subjective preferences were scored in terms of loudness, clearness, spaciousness, fullness and overall impression, In the subjective listening test, 12 subjects were participated who have plentiful listening experiences, The programs include 5 kinds of musics; korean popular song, pop song, light music, male-voice and classic, The 8 models of the headphones were employed, including 4 closed-type circumaural headphones, 2 open-type supraaural headphones and 2 intra-concha headphones, A significant test was carred on the results from the subjective test, using a two-way ANOVA test, The correlation coefficients between the acoustical parameters and the subjective preferences were computed, Experimental results showed that the variation of the magnitude of frequency response measured from a right channel revealed higher correlation with the subjective preferences. Whereas the inter-aural correlation coefficients have very low correlation coefficients.

Performance Evaluation of Ocean Small Hydropower Plant by Analyzing Water Level and Flow Rate of Circulating Water (방류수의 수위 및 유량 분석을 통한 해양 소수력 성능평가)

  • Kang, Keum-Seok;Kim, Ji-Young;Ryu, Moo-Sung
    • New & Renewable Energy
    • /
    • v.5 no.3
    • /
    • pp.32-39
    • /
    • 2009
  • The Samcheonpo ocean small hydropower plant (SHP) has a special feature of using marginal hydraulic head of circulating water system of fossil fuel power plant as a power source and having the characteristics of general hydropower generation and tidal power generation as well. Also, it contributes to reducing green house gases and developing clean energy source by recycling circulating water energy otherwise dissipated into the ocean. The efficiency of small hydropower plant is directly affected by effective head and flow rate of discharged water. Therefore, the efficiency characteristics of ocean hydropower plant are analyzed with the variation of water level and flow rate of discharged water, which is based on the accumulated operation data of the Samcheonpo hydropower plant. After the start of small hydropower plant operation, definite rise of water level was observed. As a result of flow pattern change from free flow to submerged flow, the instability of water surface in overall open channel is increased but it doesn't reach the extent of overflowing channel or having an effect on circulation system. Performance evaluation result shows that the generating power and efficiency of small hydropower exceeds design requirements in all conditions. Analysis results of CWP's water flow rate verify that the amount of flowing water is measured less and the highest efficiency of small hydropower plant is achieved when the effective head has its maximum value. In conclusion, efficiency curve derived from water flow rate considering tidal level shows the best fitting result with design criteria curve and it is verified that overall efficiency of hydropower system is satisfactory.

  • PDF

A Study on the performance improvement by loop interference cancellation and adaptive equalizer in OFDMA based Wibro relay station (OFDMA 기반 Wibro 중계국에서 루프 간섭 제거 및 적응 등화기를 이용한 성능 개선에 관한 연구)

  • Lee, Chong-Hyun;Lim, Seung-Gag
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.11 s.353
    • /
    • pp.141-148
    • /
    • 2006
  • This paper deals with the performance improvement by eliminating loop interference signal and inserting adaptive equalizer for phase compensation in OFDMA based Wibro relay station. The Wibro relay station is used for the extension of communication service area and for throughput improvement of base station. The loop interference is important factor of performance determination of relay station when transmitter and receiver is very closely located. In order to design interference canceller, we generated base-band OFDMA signal and then transmitted the signal along with pilot tones alined with two different combinations for training mode. And then, we generated received fading signal due to the loop interference added noise to the received signal. In the receiver, the transmitted signal is recovered by elimination of the interference signal with channel estimate and compensating phase by adaptive equalizer. The performance improvement was verified by computer simulation which show channel estimation, constellation of signal and BER characteristics according to the variation of SNR ratio.

Improvement of Hysteresis Characteristics of Low Temperature Poly-Si TFTs (저온 Poly-Si TFT 소자의 Hysteresis 특성 개선)

  • Chung, Hoon-Ju;Cho, Bong-Rae;Kim, Byeong-Koo
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.2 no.1
    • /
    • pp.3-9
    • /
    • 2009
  • Although Active matrix organic light emitting diode (AMOLED) display has a better image quality in terms of viewing angle, contrast ratio, and response time than liquid crystal displays (LCDs), it still has some critical issues such as lifetime, residual images, and brightness non-uniformity due to non-uniformity in electrical characteristics of driving TFTs and IR drops on supplied power line. Among them, we improved irrecoverable residual images of AMOLED displays which is mainly related to the hysteresis characteristics of driving TFTs. We consider four kinds of surface treatment conditions before gate oxide deposition for improving hysteresis characteristics. We can reduce the hysteresis level of p-channel TFT to 0.23 V, interface trap states between the poly-Si layer and gate insulator to $3.11{\times}10^{11}cm^{-2}$, and output current variation of p-channel TFT to 3.65 % through the surface treatment using ultraviolet light and H2 plasma. Therefore, the recoverable residual image problem of AMOLED displays can be improved by surface treatment using ultraviolet light and $H_2$ plasma.

  • PDF

Synchronous Reservation Protocol for Variable-sized Messages in a WDM-based Local Network (WDM 망에서 가변 길이의 메시지 전송을 위한 동기 예약 프로토콜)

  • Lee, Jae-Hwoon;Rim, Min-Joong
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.38 no.6
    • /
    • pp.1-10
    • /
    • 2001
  • In this paper, we propose a synchronous reservation protocol that is efficient for supporting variable sized messages in a wavelength division multiplexing (WDM) based local network using a passive star topology. A. control channel is used to coordinate transmission on data channels. Time is slotted with fixed-sized slots. The network can accommodate a variable number of nodes, and can operate independently of the change of the number of nodes. So, any 'new' node can join the network anytime without network re-initialization. Moreover, with the protocol, we can avoid data channel and destination conflicts. We analyze the performance by using EPA method according to the variation of the end to end propagation delay with respect to one slot time, and validate the results by simulation.

  • PDF

Performance Analysis of IBAC DAB System for Bandwidth in Korea FM Interference Environmentlevance Feedback (국내 FM 간섭환경에서 대역폭에 따른 IBAC DAB 시스템의 성능분석)

  • 조병록;김태훈;오길남
    • Journal of Broadcast Engineering
    • /
    • v.5 no.2
    • /
    • pp.211-219
    • /
    • 2000
  • The IBAC DAB system was interfered by existing FM broadcasting signal as was used guardband within existing FM broadcasting. The FM interference signals are very important parameter in performance evaluation of IBAC DAB system. We got the characteristic of FM PSD in according to instantaneous change and average characteristic of FM broadcasting signal in according to characteristic of FM channel. In this paper, based on proposed IBAC DAB system, we analyze effects of FM interference for occupied bandwidth and performance of IBAC DAB modeling various FM interference signals with sum of sinusoid function using C language, suggest FM interference ratio that can maintain performance. We was know that IBAC DAB system have a great performance variation in according to average characteristic of FM PSD by simulation results, also, FM interference ration that can maintain performance of system is 10dB.

  • PDF