• Title/Summary/Keyword: Channel Section

Search Result 563, Processing Time 0.028 seconds

Seismic behavior of steel reinforced concrete special-shaped column-beam joints

  • Liu, Z.Q.;Xue, J.Y.;Zhao, H.T.
    • Earthquakes and Structures
    • /
    • v.11 no.4
    • /
    • pp.665-680
    • /
    • 2016
  • This paper focuses on the study of seismic behavior of steel reinforced concrete special-shaped column-beam joints. Six specimens, which are designed according to the principle of strong-member and weak-joint core, are tested under low cyclic reversed load. Key parameters include the steel form in column section and the ratio of column limb height to thickness. The failure mode, load-displacement curves, ductility, stiffness degradations, energy dissipation capacity and shear deformation of joint core of the test subassemblies are analyzed. The results indicate that SRC special-shaped column-beam joints have good seismic behavior. All specimens failed due to the shear failure of the joint core, and the failure degree between the two sides of joint core is similar for the exterior joint but different for the corner joint. Compared to the joints with channel steel truss, the joints with solid web steel skeleton illustrate better ductility and energy dissipation capacity, but the loading capacity and stiffness are roughly close. With the increasing of the ratio of column limb height to thickness, the joints illustrate higher loading capacity and stiffness, better energy dissipation capacity, but worse ductility.

The Effect of BSA on the Release of Cefadroxil from a Polycaprolactone Matrix (폴리카프로락톤 매트릭스로부터 세파드록실의 방출에 미치는 BSA의 영향)

  • Kim, Seung-Ryul;Jung, Yun-Jin;Kim, Young-Mi;Lee, Chi-Ho;Kim, Dae-Duk
    • Journal of Pharmaceutical Investigation
    • /
    • v.34 no.5
    • /
    • pp.363-368
    • /
    • 2004
  • In order to investigate the effect of bovine serum albumin (BSA), as a pore former, on the controlled release of an antibiotic from a biodegradable polymeric device, polycaprolactone (PCL)-cefadroxil matrices were prepared by the solvent casting method. The amount of cefadroxil released from various formulations at $37^{\circ}C$ was measured by HPLC. The duration of antimicrobial activity of matrices against S. aureus was evaluated by measuring the diameters of the inhibition zone. The morphology of the matrices was investigated by scanning electron microscopy (SEM). The release rate and extent of cefadroxil from PCL matrix increased as the loading dose and particle size of BSA/cefadroxil mixture powder increased. Cefadroxil released from the matrix exhibited antibacterial activity for up to 4 days. SEM of the cross-section of matrix showed the typical channel formation after 3 days of release study. Thus, a biodegradable polymeric matrix loaded with antibiotic/BSA mixture can effectively prevent bacterial infection on its surface, thereby bringing about an enhancement of biocompatibility of biomaterials.

Flood Routing on the River by Revised Muskingum-Cunge Method (하도에서의 홍수추적 -수정 Muskingum-Cunge 방법-)

  • 홍종운
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.21 no.1
    • /
    • pp.13-23
    • /
    • 1979
  • The predictien of a design flood hydrograph at a particular site on a river may be based on the derivation of a discharge or stage hydrograph at an upstream section, together with a method to route this hydrograph along the rest of the river. In order to limit this investigation to cases where the assumption like uniform rainfall may be reasonably valid, the derivation of unit hydrographs has been limited to catchment with an area less than 500 km2. Consequently, flood routing methods provide a useful tool for the analysis of flooding in all but the smaller catchment, particularly where the shape of the hydrograph as well as the peak value is required. The author, therefore, will introduce here a flood routing method on the open channel with a peak discharge of the catchment area concerned. The importance of being able to route floods accurately is also reflected in the large number of flood routing method which have been developed since the year 1900. There are the modified puls method, Steinberg method, Goodrich method, Ekdahl method, Tatum's mean continuously Equation, wisler-Brater method, Muskingum, chung, and Muskingum-cunge (M-C) method and so on. The author will try to introduce a flood routing method which is revised Muskingum-cunge method. In calculating flood routing by the M-C method, whole variable parameters on the river were assumed to almost uniform values from the upstream to the downstream. In the results, the controlled flood rates at the 40km downstream on the river is appeared to decrease 22m$^3$/sec or 12 percent of the peak flood 170m$^3$/sec.

  • PDF

Poly-Si Thin Film Transistor with poly-Si/a-Si Double Active Layer Fabricated by Employing Native Oxide and Excimer Laser Annealing (자연 산화막과 엑시머 레이저를 이용한 Poly-Si/a-Si 이중 박막 다결정 실리콘 박막 트랜지스터)

  • Park, Gi-Chan;Park, Jin-U;Jeong, Sang-Hun;Han, Min-Gu
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.1
    • /
    • pp.24-29
    • /
    • 2000
  • We propose a simple method to control the crystallization depth of amorphous silicon (a-Si) deposited by PECVD or LPCVD during the excimer laser annealing (ELA). Employing the new method, we have formed poly-Si/a-Si double film and fabricated a new poly-Si TFT with vertical a-Si offsets between the poly-Si channel and the source/drain of TFT without any additional photo-lithography process. The maximum leakage current of the new poly-Si TFT decreased about 80% due to the highly resistive vertical a-Si offsets which reduce the peak electric field in drain depletion region and suppress electron-hole pair generation. In ON state, current flows spreading down through broad a-Si cross-section in the vertical a-Si offsets and the current density in the drain depletion region where large electric field is applied is reduced. The stability of poly-Si TFT has been improved noticeably by suppressing trap state generation in drain region which is caused by high current density and large electric field. For example, ON current of the new TFT decreased only 7% at a stress condition where ON current of conventional TFT decreased 89%.

  • PDF

Thermal Characteristics of Discrete Heat Sources Using Coolants

  • Choi, Min-Goo;Cho, Keum-Nam
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.1
    • /
    • pp.1-10
    • /
    • 2001
  • The present study investigated the effects of experimental parameters on the thermal characteristics of an in-line 6x1 array of discrete heat sources for a test multichip module using water, PF-5060 and paraffin slurry. The parameters were heat flux of 10-40W/$cm^2$. Reynolds number of 3,000~20,000 and mass fraction up to 10% for paraffin slurry The size of paraffin slurry was within 10~40$\mu$m before and after experiments. The local heat transfer coefficients for the paraffin slurry were larger than those for water. Thermally fully developed conditions were observed after the third or fourth row (five or seven times of the chip length) and the paraffin slurry showed effective cooling performance at the high heat flux The paraffin slurry with the mass fraction of 5% showed the most efficient cooling performance when the heat transfer and the pressure drop in the test section are considered simultaneously. The experimental data at the fourth and sixth rows are best agreed with the values predicted by the Malina and Sparrow`s correlation among other correlations, and the empirical correlations for water and 5% paraffin slurry were obtained at the first and sixth rows when the channel Reynolds number is over 3,000.

  • PDF

Calculations of Incompressible Flows In General Nonorthogonal Body Fitted Coordinates: Comparison of Hybrid and QUICK Sehemes (일반 비직교 표면좌표계에서의 비압축성 점성유동의 수치해석)

  • Gang, Dong-Jin;Bae, Sang-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.5
    • /
    • pp.1613-1623
    • /
    • 1996
  • In this paper, two discretization methods, hybrid and QUICK, are tested for the Navier-Stokes equations written in general nonorthogonal body fitted coordinates. Comparison is made by calculating two laminar flows at low Reynolds numbers of 10 - 100. One is a two-dimensional channel of gradually expanding cross section and the other is an axisymmetric flow through a circular tube having a circular constriction. Results show that the QUICK scheme results in a numerical solution more accurate than that of hybrid. The QUICK scheme also shows faster convergence for both test cases. As the number of grid points increases, all numerical solutions converge with more oscillation. The number of grid points in the y-direction(cross stream direction) is also shown to play a significant role in the approximation of convection term within separated flow zone.

The Heat Transfer Analysis of the First Stage Blade (발전용 가스터빈 1단 동익 열전달 해석)

  • Hong, Yong-Ju;Choi, Bum-Seog;Park, Byung-Gyu;Yoon, Eui-Soo
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.30-35
    • /
    • 2001
  • To get higher efficiency of gas turbine, The designer should have more higher turbine inlet temperature (TIT). Today, modem gas turbine having sophisticated cooling scheme has TIT above $1,700^{\circ}C$. In the korea, many gas turbine having TIT above $1,300^{\circ}C$ was imported and being operated, but the gas with high TIT above $1,300^{\circ}C$ in the turbine will give damage to liner of combustor, and blade of turbine and etc. So frequently maintenance for parts enduring high temperature was performed. In this study, the heat transfer analysis of cooling air in the internal cooling channel (network analysis) and temperature analysis of the blade (Finite Element Analysis) in the first stage rotor was conducted for development of the optimal cooling passage design procedure. The results of network analysis and FEM analysis of blade show that the high temperature spot are occured at the leading edge, trailing edge near tip, and platform. so to get more reliable performance of gas turbine, the more efficient cooling method should be applied at the leading edge and tip section. and the thermal barrier coating on the blade surface has important role in cooling blade.

  • PDF

Development of Multi-channel Eddy Current System for Inspection of Press Rolls (압연롤 검사를 위한 다중 센서 와전류 탐상 검사 시스템 개발)

  • Lee, Jae-Ho;Park, Tae-Sung;Park, Ik-Keun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.26 no.3
    • /
    • pp.306-312
    • /
    • 2017
  • Press rolls are constantly exposed to physical and heat stresses on their surface and are prone to crack, bruise, and spall if the accumulated stress goes beyond the critical point. Such surface phenomenon can cause them to lose their functionality and eventually lead to a halted production line. Eddy current testing can be considered a useful method to investigate the surface of the roll. The method involves the application of a high intensity magnetic field onto the surface of the roll, and thereby finding any early stage of possible defects. When the method was applied for roll inspection, the cross section of the sensor was regulated as per the overall testing speed. A smaller cross sectional area implied a better resolution but a longer testing time. In this paper, a convenient method to increase both overall system resolution and inspection speed of eddy current roll inspection is suggested by using a devised array sensor structure.

Improving HSPF Model's Hydraulic Accuracy with FTABLES Based on Surveyed Cross Sections (실측 하천 단면자료를 이용한 HSPF 유역모델의 수리정확도 개선)

  • Shin, Chang Min
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.6
    • /
    • pp.582-588
    • /
    • 2016
  • The hydrological simulation program FORTRAN (HSPF) is a comprehensive watershed model that employs the hydraulic function table (FTABLE) (depth-area-volume-flow relationship) to represent the geometric and hydraulic properties of water bodies. The hydraulic representation of the HSPF model mainly depends on the accuracy of the FTABLES. These hydraulic representations determine the response time of water quality state variables and also control the scour, deposition, and transport of sediments in the water body. In general, FTABLES are automatically generated based on reach information such as mean depth, mean width, length, and slope along with a set of standard assumptions about the geometry and hydraulics of the channel, so these FTABLES are unable to accurately describe the geometry and hydraulic behavior of rivers and reservoirs. In order to compensate the weakness of HSPF for hydraulic modeling, we generated alternate method to improve the accuracy of FTABLES for rivers, using the surveyed cross sections and rating curves. The alternative method is based on the hydraulics simulated by HEC-RAS using the surveyed cross sections and rating curves, and it could significantly improve the accuracy of FTABLES. Although the alternate FTABLE greatly improved the hydraulic accuracy of the HSPF model, it had little effect on the hydrological simulation.

Development of a correlation on the convective heat transfer of supercritical pressure $CO_2$ vertically upward flowing in a circular tube (원형관에서 수직상향유동 초임계압 $CO_2$의 대류열전달 상관식 개발)

  • Kang, Deog-Ji;Kim, Hwan-Yeol;Bae, Yun-Young
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.292-295
    • /
    • 2008
  • In a SCWR (SuperCritical pressure Water cooled Reactor), the coolant temperature initially at below the pseudo-critical temperature at the bottom of a reactor core increases as the coolant flows upward through the sub-channels of the fuel assemblies, and it finally becomes higher than the pseudo-critical temperature when it leaves the reactor core. At certain conditions, heat transfer deterioration occurs near the pseudo-critical temperature and it may cause a drastic rise of the fuel surface temperature resulting a fuel failure. Therefore, an accurate estimation of the heat transfer coefficient is very important for the thermal-hydraulic design of a reactor core. An experiment on heat transfer to the vertically upward flowing $CO_2$ at a supercritical pressure in a circular tube were performed at KAERI. The internal diameter of the test section is 6.32 mm, which corresponds to the hydraulic diameter of a sub-channel in the conceptional design proposed by KAERI. The test range of the mass flux is 285 to 1200 kg/m$^2$s and the maximum heat flux is 170 kW/m$^2$. The inlet pressure is maintained at 8.12 MPa, which is 1.1 times the critical pressure. A new correlation, which covers both the normal and deterioration heat transfer regimes was proposed and compared with the estimations by exiting correlations.

  • PDF