• Title/Summary/Keyword: Channel Characterization

Search Result 199, Processing Time 0.029 seconds

Enhanced Field Electron Emission from Dielectric Coated Highly Emissive Carbon Fibers

  • Almarsi, Ayman M.;Hagmann, Mark J.;Mousa, Marwan S.
    • Applied Microscopy
    • /
    • v.47 no.1
    • /
    • pp.55-62
    • /
    • 2017
  • This paper describes experiments aimed at characterizing the behavior of field electron emitters fabricated by coating carbon fibers with epoxylite resin. Polyacrylonitrile carbon fibers of type VPR-19, thermally treated at $2,800^{\circ}C$, were used. Each was initially prepared in a "uncoated" state, by standard electro polishing and cleaning techniques, and was then examined in a scanning electron microscope. The fiber was then baked overnight in a field electron microscope (FEM) vacuum chamber. Current-voltage characteristics and FEM images were recorded on the following day or later. The fiber was then removed from the FEM, coated with resin, "cured" by baking, and replaced in the FEM. After another overnight bake, the FEM characterization measurements were repeated. The coated fibers had significantly better performance than uncoated fibers. This confirms the results of earlier experiments, and is thought to be due in part to the formation of a conducting channel in the resin over layer. For the coated fiber, lower voltages were needed to obtain the same emission current. The coated fibers have current-voltage characteristics that show smoother trends, with greater stability and repeatability. No switch-on phenomena were observed. In addition, the emission images on the phosphor-coated FEM screen were more concentrated, and hence brighter.

Transcriptome Analysis to Characterize the Immune Response of NecroX-7 in Mouse CD4+ T Cells

  • Kim, Eun-Jung
    • Biomedical Science Letters
    • /
    • v.21 no.2
    • /
    • pp.60-68
    • /
    • 2015
  • NecroX-7 is a novel small compound of the NecroX series based on the indole moiety, which has potent cytoprotective and antioxidant properties. We previously detected potential immune regulatory effects of NecroX-7 in immune related diseases like Graft-versus-Host Disease. However, the function and the underlying mechanisms of immunological effects of NecroX-7 in the immune system have not been well established. In this study, we investigated the immune response characterization of differentially expressed genes of NecroX-7 administration in $CD4^+$ T cells by microarray analysis. $CD4^+$ T cells stimulated with NecroX-7 ($40{\mu}M$) or vehicle for 72 hours resulted in the identification of 337 differentially expressed genes (1.5 fold, P<0.05) by expression profiling analysis. Twenty eight of the explored NecroX-7-regulated genes were related to immune system processes. These genes were validated by quantitative real-time PCR. The most significant genes were glutathione reductase, eukaryotic translation elongation factor 1, lymphotoxin-alpha, heat shock protein 9 and chloride intracellular channel protein 4. These findings demonstrate the strongly immune response of NecroX-7 in $CD4^+$ T cells, suggesting that cytoprotection and immune regulation may underlie the critical aspects of NecroX-7 exposure.

Effects of Nb and Ti Addition and Surface Treatments on the Electrical Conductivity of 316 Stainless Steel as Bipolar Plates for PEMFC (고분자전해필 연료전지 분리판용 316 스테인리스강의 전기전도도에 미치는 Nb, Ti 첨가 및 표면처리 효과)

  • Lee, Seok-Hyun;Kim, Jeong-Heon;Kim, Min-Chul;Chun, Dong-Hyun;Wee, Dang-Moon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.324-324
    • /
    • 2006
  • Nb and Ti were added to 316 stainless steel, and then heat-treatments and surface treatments were performed on the 316 stainless steel and the Nb- and Ti-added alloys. All samples indicated enhanced electrical conductivity after surface treatments, whereas they showed low electrical conductivity before surface treatments due to the existence of non-conductive passive film on the alloy surface. In particular, the Hb- and Ti-added alloys showed remarkable enhancement of electrical conductivity compared to the original alloy, 316 stainless steel. Surface characterization revealed that small carbide particles formed on the alloy surface after surface treatments, while the alloys indicated flat surface structure before surface treatments. $Cr_{23}C_6$ mainly formed on the 316 stainless steel, and NbC and TiC mainly formed on the Nb- and Ti-added alloys, respectively. We attribute the enhanced electrical conductivity after surface treatments to the formation of these carbide particles, possibly acting as a means of electro-conductive channel through the passive film. Furthermore, NbC and TiC are supposed to be more effective carbides than $Cr_{23}C_6$ as electro-conductive channels of stainless steel

  • PDF

Cloning of Xenopus laevis TRPV2 by Gene Prediction

  • Lee, Jung Youn;Shim, Won Sik;Oh, Uhtaek
    • Genomics & Informatics
    • /
    • v.3 no.1
    • /
    • pp.24-29
    • /
    • 2005
  • TRPV2 is a non-specific cation channel expressed in sensory neurons, and activated by noxious heat. Particularly, TRPV2 has six transmembrane domains and three ankyrin repeats. TRPV2 has been cloned from various species such as human, rat, and mouse. Oocytes of Xenopus laevis - an African clawed frog ­have been widely used for decades in characterization of various receptors and ion channels. The functional property of rat TRPV2 was also identified by this oocyte expression system. However, no TRPV2 orthologue of Xenopus laevis has been reported so far. Hence, we have focused to clone a TRPV2 orthologue of Xenopus laevis with the aid of bioinformatic tools. Because the genome sequence of Xenopus laevis is not available until now, a genome sequence of Xenopus tropicalis - a close relative species of Xenopus laevis - was used. After a number of bioinformatic searches in silico, a predicted full-length sequence of TRPV2 orthologue of Xenopus tropicalis was found. Based on this predicted sequence, various approaches such as RT-PCR and 5' -RACE technique were applied to clone a full length of Xenopus laevis TRV2. Consequently, a full-length Xenopus laevis TRPV2 was cloned from heart cDNA.

Expression and Characterization of G Protein-activated Inward Rectifier $K^+$ Channels in Xenopus Oocytes

  • Kim, Han-Seop;Lee, Chang-Ho;Min, Churl K.
    • Animal cells and systems
    • /
    • v.2 no.4
    • /
    • pp.471-476
    • /
    • 1998
  • The G protein-activated inwardly rectifying $K^+$ channel (GIRK1) was coex-pressed in Xenopus oocytes along with the $5-HT_{1A}$ receptor, a 7-helix receptor known to be coupled to $K^+$ channels in many neural tissues. Thus, the activation of the $5-HT_{1A}$ receptor by its agonist leads to the opening of GIRK1. The GIRK1 current was measured using the two electrode voltage clamp technique with bath application of 5-HT in the presence of various external potassium concentrations $[K^+]_0$. GIRK1 showed a strong inward rectification since only hyperpolarizing voltages evoked inward currents. $K^{+}$ was the major ion carrier as evidenced by about 44㎷ voltage shift corresponding to a 10-fold external 〔$K^+$〕 change. 5-HT induced a concentration-dependent inward $K^+$ current ($EC_{50}{\equation omitted}10.7nM$) which was blocked by $Ba^{2+}$. Pertussis toxin (PTX) pre-treatment reduced the $K^+$ current by as much as about 70%, suggesting that PTX-sensitive G protein ($G_i or G_o$ type) are involved in the $5-HT_{1A}$ receptor-GIRK1 coupling in Xenopus oocytes.

  • PDF

Electrical Characteristics of InAlAs/InGaAs/InAlAs Pseudomorphic High Electron Mobility Transistors under Sub-Bandgap Photonic Excitation

  • Kim, H.T.;Kim, D.M.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.3 no.3
    • /
    • pp.145-152
    • /
    • 2003
  • Electrical gate and drain characteristics of double heterostructure InAlAs/InGaAs pseudomorphic HEMTs have been investigated under sub-bandgap photonic excitation ($hv). Drain $(V_{DS})-,{\;}gate($V_{DS})-$, and optical power($P_{opt}$)-dependent variation of the abnormal gate leakage current and associated physical mechanisms in the PHEMTs have been characterized. Peak gate voltage ($V_{GS,P}$) and the onset voltage for the impact ionization ($V_{GS.II}$) have been extracted and empirical model for their dependence on the $V_{DS}$ and $P_{opt} have been proposed. Anomalous gate and drain current, both under dark and under sub-bandgap photonic excitation, have been modeled as a parallel connection of high performance PHEMT with a poor satellite FET as a parasitic channel. Sub-bandgap photonic characterization, as a function of the optical power with $h\nu=0.799eV$, has been comparatively combined with those under dark condition for characterizing the bell-shaped negative humps in the gate current and subthreshold drain leakage under a large drain bias.

Nonlinear Characterization of EEG Under the Internal and External Stimuli (내·외적인 자극을 받는 뇌파의 비선형 동력학적 특징)

  • Jung, Ki-Young;Kim, Jae-Moon;Yoo, Cheol-Seung;Yi, Sang-Hoon
    • Annals of Clinical Neurophysiology
    • /
    • v.4 no.1
    • /
    • pp.28-33
    • /
    • 2002
  • Backgrounds and objective : EEG reflect dynamic changes of continuous neuronal activities by internal and external stimuli. The aim of this study is to quantify nonlinearly the local dynamic differences among EEG data corresponding to different states of brain. Methods : EEG was recorded from twelve healthy normal subjects(mean age, 29.7 years; 8 men and 4 women) using digital EEG machine. 18-channel EEG data were selected during eyes closed(EC), eyes open(EO), and mental arithmetic(MA) in each subject. Correlation dimension(D2) and largest Lyapunov exponent(LLE) were calculated from three states and average value was mapped 2 dimensionally and compared with each other. Results : The distribution of D2 was relatively symmetric and its value was higher in frontal than in parieto-occipital region during EC. These findings were reversed during EO. Bilateral centro-temporo-parietal region showed high D2 value in MA compared with those in EC, which was more prominent in left side. LLE was larger than zero in all state and showed significant differences among EC, EO and MA(p=0.000). Conclusion : These results suggest that nonlinear analysis of EEG can quantify dynamic state of brain.

  • PDF

Study of Channel Model Characterization of Human Internal Organ in On-Body System at 2.45 GHz (2.45 GHz On-Body 시스템에서 인체 내부 장기에 따른 채널 모델 특징 연구)

  • Jeon, Jaesung;Choi, Jaehoon;Kim, Sunwoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.1
    • /
    • pp.62-69
    • /
    • 2014
  • In this paper, WBAN(Wireless Body Area Network) On-body system using the surface-oriented antenna about the impact of human internal organs were analyzed through experiments. The received signal strength is measured for effect of human using the human model and the phantom of torso. Experiments are performed in anechoic chamber without moving and measured by Vector Network Analyzer. This paper confirms the effect of human body by comparing the human model and the phantom of torso. And also know the human internal organs effect on the antennas loss of received signal strength by measured data.

Fabrication and characterization of SiO2 based waveguide co-doped with Si-nanocrystal and Er3+ (Si 나노 입자와 Er3+를 공첨가한 SiO2계 도파로의 제작과 평가)

  • Choi, Se-Weon;Ko, Young-Ho;Chang, Se-Hun;Oh, Ik-Hyun;Kang, Chang-Seog
    • Korean Journal of Materials Research
    • /
    • v.17 no.4
    • /
    • pp.222-226
    • /
    • 2007
  • [ $SiO_2$ ]thin films containing Si-nanocrystals and $Er^{3+}$ were fabricated by the RF-sputtering method. Intense emission of $Er^{3+}$ was observed at 1530 nm region after the annealing of the film at $1050^{circ}C$ for 5 min. Channel waveguides were fabricated using such films for the core. The films containing Si higher than 2.4 at% exhibited the change in stress from compression to tension after annealing, which induced the fatal loss-increase in waveguide. The optical gain might be attained by the Er-doped waveguide with Si lower than 2.4 at% by a visible-light-excitation.

Automatic Switching System for The Impedance Analysis of Multichannel icroelectrode Arrays: Limits and Improvement Scheme (다채널 미세전극칩 임피던스 분석을 위한 자동 스위칭 시스템: 한계점 및 개선 방안)

  • Lee, Seok-Young;Nam, Yoon-Key
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.3
    • /
    • pp.207-217
    • /
    • 2011
  • Electrode impedances are measured to quantitatively characterize the electrode-electrolyte or cell-electrode interfaces. In the case of high-density microelectrode arrays(MEAs) that have been developed for brainmachine interface applications, the characterization process becomes a repeating and time-consuming task; a system that can perform the measurement and analysis in an automated fashion with accuracy and speed is required. However, due to the large number of channels, parasitic capacitance and off-capacitance components of the switching system become the major factors that decreased the accuracy for the measurement of high impedance microelectrodes. Here we investigated the implementation of automatic impedance measurement system with analyzing the causes of possible measurement-related problems in multichannel switching configuration. Based on our multi-channel measurement circuit model, we suggest solutions to the problems and introduce a novel impedance measurement scheme using electro-mechanical relays. The implemented measurement system could measure |Z| < 700 $k{\Omega}$ of impedance in - 10% errors, which can be widely applicable to high density neural recording MEAs.