• 제목/요약/키워드: Change of body size

검색결과 329건 처리시간 0.038초

전척수(全脊髓) 및 경막외차단(硬膜外遮斷)으로 편타성(鞭打性) 손상(損傷)의 통증치험(痛症治驗) (4례(例) 보고(報告)) (Total Spinal Block and Cortical Epidural Block for Whiplash Syndrome and Reflex Sympathetic Dystrophy (Report of Four Cases))

  • 박오;옥시영;송후빈
    • The Korean Journal of Pain
    • /
    • 제1권1호
    • /
    • pp.106-119
    • /
    • 1988
  • For the relief of pain in 3 cases of whiplash syndromes (case I, II and IV) and in one of reflex sympathetic dystrophy (case III), we have carried out six intentional. total spinal blocks (TSB) which attempted two times in case I, three in case II and one in carte III whoso various symptoms were chronically unresponsive to the usual conservative treatments, and a time of cervical epidural and right suprascapular nerve block in case W whose acute symptom lasted 4 drys following the cervical injury (see fables from 1 to 9). During the 753, we have observed clinically the sequential charges of respiration, lid and pupil reflexes, body motion and consciousness. And checked the blood pressure, pulse rate and arterial Pco2. The effectiveness of those blocks has been assessed by using the Visual Analog Scale which is designed to measure the patient$\acute{s}$ subjective intensity of pain and also we have found out the sequelae following those blocks. The methods of the blocks were as the following: 1. Under the N.P.O. for 8~10 hours, the preparations of immediate cardiopulmonary resuscitation and premedication with atropine 0.5mg at thirty minutes before the TSB, it was performed by injecting the mixture of 2% mepivacaine 10 or 15ml and normal saline 10 or 5ml through No. 23 G. spinal needle into the subarachnoid space of $C_7-T_1$ interspinous region with fully flexed neck on the lateral posture. Immediately after the injection of the local anesthetic in the lateral position, the patient$\acute{s}$ were hasten to change Trendelenburg$\acute{s}$ position in order to act the drugs cephalad and to make easy controlled respiration with oxygen. 2. The cervical epidural block was done by injecting the mixture of 0.5% bupivacaine 4ml, normal saline 4ml and triamcinolone 15mg through No. 18 G. Tuohy needle into the epidural space on the same region and posture as the above without premedication.7he suprascapular nerve block was done by injecting of 0.5% bupivacaine 3ml only into the right suprascapular fossa on the sitting posture. The results were as the following: 1. The cessation of respiration was seen within 5 minutes following the subarachnoidal injection of the above 20ml mixture in 2 to 3 minutes and then soon the consciousness began to disappear. The loss of Lid and pupil reflexes noted between 5 to 10 minutes and the size of the dilated pupils was equal between 5 to 20 minutes, but the pupil of the dependent side on tile lateral position was dilated 1 to 3 minutes earlier than that of the independent. The patients had r=ever responded to any stimulations during the TSB except their heart funtion. 2. The recovery of the TSB was as the following, firstly the ankle and lower limb of the independent side began to move slightly with in 34 to 75 minutes after the injection and then that of the dependent Secondly the neck and upper limb moved 6 to 15 minutes later than the lower limb. Thirdly the self respiration began to appear between 40 to 80 minutes from the block. The lid and pupil reacted to touch and light respectively between 40 to 80 minutes but the pupil of the independent side responded earlier than that of the depends. Lastly the consciousness recovered completely between 80 to 125 minutes from the block. 3. In the cardiopulmonary function during the TSB, the blood pressure were stable except the 210/130 tory at the and block of case I. There were bradycardias between 65 to 85 minutes in case I and II but no arrythmia on the EKG. The level of the arterial Pco2 was maintained to 43~45 torr during the TSB. 4. The effectiveness of the above blocks was no pain(0%) in case IV, and light (10~20%) in case I and II but no improvement in case III. 5. The right arm weakness has been complicated as to be Injected accidently the "COLD" local anesthetic at the End block of case I.

  • PDF

간호기기 개발수요 조사연구 (A Study on the Demand for Equipent Development in Nursing)

  • 장순복;김의숙;황애란;강규숙;서미혜
    • 대한간호
    • /
    • 제35권2호
    • /
    • pp.71-91
    • /
    • 1996
  • The objectives of thes study were to identify the need for equipment development in nursing, and to determine the priorities for that development. The study was descriptive study done between March 2 and May 30, 1995, in which the subjects, including 421 patients, 223 family members, and 198 nurses from neurosurgery, orthopedic, rehabilitation medicine, internal medicine and intensive care units of nine general hospitals in Seoul, completed a questionnarie developed by the research team. The questionnaire consisted of 35 open and closed questions. Data was analyzed using frequencies and percentages. The results ware summarized as follows: 1) The average age of the nurses was 27.9 years, 48% of the patients were between 20 and 40 years of age, and 17% were over 60. The average lingth of experience for the nurse subjects was four years five months with 36.9%. having over five years experience. The most frequent diagnoses of patients were spinal disc(35.9%), internal medicine disease(26.0%), cerebral vascular accident(16.6%) and spinal cord injury(10%) 2) Many of the nurses(96.4%) reported deficiencies with existing equipment and 96.5% of the nurses, but only 79.8% of the patients, nurses' time. Further, 82.3% of the nurses and 75.8% of the patients felt that the development of new equipment would lead to a decrease in the cost of nursing care. 3) Nurses felt that the greatest areas of inconvenience were patient feeding(71.7%), hygiene(71.2%), caring for a patient confined to bed(70.7%), patient clothing(67.2%), mobility transfers(63.5%) and urinary elimination(52.0%). However, patients and family members listed the following as being the most inconvenient: urinary elimination(58.7%), Hygiene(50.5), feeding(48.4%), mobility transfers(47.1%) and bed care(45.2%). 4) Generally the nurses listed more inconveniences and patients and family members listed more demands for the development of equipment. These included utensils with large handles, and regulators for tube feedings; mattresses that provide for automatic position change and massage, which have patient controlled levers and a place for bed pan insertion; automatic lifts or transfer from bed to wheelchair; equipment to facilitate washing and oral hygiene as well as equipment that will allow patients with spinal cord injuries easy access to showers; a bed pan/urinal for women that is comfortable and effective from which urine can be measured and disposed of easily; disposable dressing sets and tracheostomy care sets and a convenient way of measuring changes in wound size; a safe delivery system for oxygen, a variety of mask sizes and better control of humidity, tracheal material than at present, as well as a communication system for patients with tracheostomies; clothing that will allow access to various parts of the body for treament or assessment without patients having to remove all of their clothing; and finally a system that will allow the patient to control lighting, telephones and pagers. Priority areas for equipment development reported by the nurses were, urinary elimination(58. 7%), hygiene(50.5%), feeding(48.4%), mobility transfers(47..1%), bowel elimination(40.8%). Those reported by the patients family members were feeding(71.7%), hygiene(70.0%), bedcare(70.7%), clothing(67.2%), mobility transfers(63.6%), urinary elimination(52.9%) and bowel elimination(50.5%) Altogether, nurses, patients and family members listed the following as priorities; clothing (178), bed care(144), urinary elimination(92), environment(81), hygiene(70). Further, a health professional forum listed urinary elimination, oxygen delivery, medication delivery, mobility transfers, bed care and hygiene in that order as priority areas. From this study it can be concluded that the first need is to develop equipment that will address the problems of urinary elimination. To do (l)This nurses who are interested in equipment development should organize an equipment development team to provide a forum for discussion and production of equipment for nursing.

  • PDF

자가심낭막절편을 이용한 심외외측통로 Fontan 수술의 결과 (Results of Extracardiac Pericardial-flap Lateral Tunnel Fontan Operation)

  • 박한기;윤영남;양홍석;유병원;최재영;박영환
    • Journal of Chest Surgery
    • /
    • 제39권4호
    • /
    • pp.281-288
    • /
    • 2006
  • 목적: 자가심낭막을 절편으로 이용한 심외외측통로 Fontan 수술은 심외통로가 성장할 수 있다는 이론적 장점을 가지고 있다. 이 수술기법의 중기성적과 심외통로의 형태학적 변화를 연구하였다. 대상 및 방법: 1993년 11월부터 2004년 12월 사이에 자가심낭막절편을 이용한 심외외측통로 Fontan수술을 시행 받은 42명 환자의 임상자료를 검토하였다. 환자의 나이는 $2.8{\pm}1.5$세였으며, 체중은 $12.3{\pm}3.2$ kg이었다. 체외외측통로는 자가심낭막을 이용하여 기저부를 유지한 상태로 제작하였다. 추적관찰 심조영술을 검토하여 하대정맥에 대한 심외통로의 직경과 단면적을 비교해 보았다. 결과: 수술사망은 4명(9.8%)이었으며, 4예 모두 저심박출증으로 사망하였다. 5명의 환자에서 2주 이상 흉막삼출이 지속되었으며, 1명의 환자가 완전방실차단으로 영구심박동기를 삽입을 요하였다. 37명에서 추적관찰이 가능하였으며 추적관찰기간은 $3.8{\pm}2.2$년이었다. 2명의 환자가 추적관찰기간 중 사망하였는데, 사망의 원인은 각각 상부장관출혈과 원인을 알 수 없는 급사였다. 2명의 환자에서 각각 대동맥판막하 협착과,심외통로와 하대정맥의 연결부위 협착으로 재수술을 받았다. 추적 기간 중 새로 발생한 부정맥은 1명에게서 발견되었고, 혈전 및 색전증에 의한 합병증은 발생하지 않았다. 결론: 자가심낭막을 이용한 심외외측통로 도관 Fontan수술법은 술식이 비교적 간단하고 안전한 방법이다. 수술 후 중기 성적은 양호하며, 심외통로는 성장할 수 있었다.

개의 실험적 수신증에 실시한 신동맥 색전술 (Transarterial embolization of renal artery in dogs with experimental hydronephrosis)

  • 장동우
    • 대한수의학회지
    • /
    • 제41권3호
    • /
    • pp.437-445
    • /
    • 2001
  • 개에서 실험적으로 편측성 신수종증을 유발한 후, 이오헥솔-에탄올 용액을 신장동맥내로 주입하여 신수종증이 유발된 신장으로의 혈류를 차단하는 신동맥 색전술을 확립하고자 본 실험을 실시하였다. 실험적 수신증은 12두의 개의 편측 근위 요관을 이중결찰하여 유발하였다. 편측의 수뇨관을 결찰한 후, 초음파상으로 동측 신장의 장축길이가 유발전에 비하여 9일째(p<0.05)와, 17일째(p<0.005)에 유의적으로 증가하였으며, 동측 신장의 피질길이가 17일째에 유의적으로 감소하며, 아울러 확장된 신우내에 액체가 저류하는 것을 관찰할 수 있었다. BUN, creatinine, ALT, calcium, phosphorus는 변화하지 않았다. 이를 통하여 12두의 개에서 요관 결찰 17일째에 편측성 수신증이 유발되었음을 확인할 수 있었다. 신장동맥 색전술은 7두의 신수종증이 유발된 신장측의 신장동맥에 대퇴동맥을 통하여 선택적으로 카테터를 삽입한 후 이오헥솔-에탄올 용액을 주입하였으며, 시술 중 심전도, 산소포화도, 체온, 맥박, 호흡수는 모두 정상범위에 있었다. 주입한 평균 에탄올 용량은 $1.94{\pm}1.24ml/kg$였다. 신장동맥 색전술 후 사망한 개체는 없었으며, 색전물질의 유출로 인한 부작용도 관찰할 수 없었다. 색전술 직후 그리고 14일째에 실시한 선택적 동맥촬영술을 통하여 색전술을 시행한 7두의 개의 신장동맥에서 재맥관화가 발생하지 않았음을 확인할 수 있었다. 초음파 검사를 통하여 신장동맥 색전술을 시행한 7두의 개의 색전된 신장은 평균 장축길이가 반대편 정상 신장에 비하여 2달째와 3달째에 유의적으로 감소하였음을 확인할 수 있었다. 이오헥솔-에탄올 용액을 이용하여 실시한 신장동맥색전술은 개의 수신증을 치료하는 안전하며, 비교적 비침습적인 치료법으로 기존의 신장절제술의 대안이 될 수 있을 것으로 사료된다.

  • PDF

동물플랑크톤의 서식 특성에 따른 분류와 먹이망: 상위포식자의 에너지원으로서 부착성 동물플랑크톤의 중요성 (Classification by Zooplankton Inhabit Character and Freshwater Microbial Food Web: Importance of Epiphytic Zooplankton as Energy Source for High-Level Predator)

  • 최종윤;나긍환;정광석;김성기;장광현;주기재
    • 생태와환경
    • /
    • 제45권4호
    • /
    • pp.444-452
    • /
    • 2012
  • 동물플랑크톤의 서식 형태에 따른 구분(부착 및 부유성)과 월별 밀도 양상을 파악하기 위해 2011년 5월부터 10월까지 수생식물이 발달된 환경에서 동물플랑크톤 채집을 수행하였다. 조사 기간 동안, 부착성 동물플랑크톤은 총 24종, 부유성 동물플랑크톤은 총 30종으로 나타났으며, 이 중 두 서식 형태 간에 일치하는 종은 20종으로 확인되었다. 부착성 동물플랑크톤은 5~7월 동안 높은 밀도를 나타낸 반면, 부유성 동물플랑크톤은 9~10월 동안 높은 밀도를 보여 상이한 계절적 차이를 보였다. 안정동위원소 분석 결과, 부착 및 부유입자 유기물, 동물플랑크톤, 어류의 ${\delta}^{13}C$${\delta}^{15}N$ 값은 계절별로 상이하였다. 부착성 동물플랑크톤은 봄, 가을 모두 부착입자 유기물에 대한 높은 의존도를 보였으나, 가을에는 부유입자 유기물에 대해서는 일부 의존하는 것으로 나타났다. 이는 수생식물의 우점 등으로 인한 먹이질의 감소와 연관되어 있을 것으로 사료된다. 그러나 부유성 동물플랑크톤은 봄과 가을 모두 부유입자 유기물에 대해서만 의존하는 것으로 나타났다. L. macrochirus는 크기에 따라 먹이원에 대한 다른 섭식 양상을 보였는데, 부착성 동물플랑크톤이 증가된 시기(봄)에 1~3 cm 크기의 L. macrochirus는 부착성 동물플랑크톤에 대한 높은 의존도를 보였으나, 가을에 부착성 동물플랑크톤 감소하자 부유성 동물플랑크톤에 대한 의존도가 높아지는 것을 확인할 수 있었다. 4~7 cm 크기의 L. macrochirus는 상대적으로 큰 먹이원인 부유성 동물플랑크톤에 높은 의존도를 보였으며, 가을에 부유성 동물플랑크톤 밀도가 증가하자 매우 높게 의존하는 것으로 나타났다. 결론적으로 습지와 같이 수생식물이 우점되는 생태계에서 동물플랑크톤은 다양한 서식 형태(부착 및 부유성)를 가진 군집이 출현하는 것으로 파악되었으며, 이들은 각각 다른 먹이원에 대해 의존하는 것으로 나타났다. 또한 상위포식자인 L. macrochirus 또한 부착 및 부유성 동물플랑크톤의 계절별 밀도 양상에 따라 상이한 의존성을 보였으며, 특히 부착성 동물플랑크톤은 봄철 치어 성장 시기의 이들의 성장 및 발달에 매우 중요한 영향을 미치는 것으로 사료된다.

포유중인 Rat 의 Progesterone 분비에 대한 포유 효과 (Effect of Suckling on Progesterone Secretion during Lactation in the Rat)

  • 오석두;성환후;민관식;윤창현
    • 한국가축번식학회지
    • /
    • 제23권2호
    • /
    • pp.95-103
    • /
    • 1999
  • 본 연구는 초산의 Wistar 계 rat를 이용하여 포유기간 중 제한포유시기와 이유시기를 조절하여 혈중 progesterone 수준을 검토하였다. 정상포유군 (NL)은 포유자의 수를 8 마리로 조절하였으며, 제한포유군 (RL)과 완전이유군 (W)은 RL0, RL5, RL10, RL15 및 RL20, 그리고 W0, W5, W10, W15 및 W20으로 각각 5 개 군으로 구분하여, 제한포유군은 각 개시일에 포유자의 수를 8마리에서 4마리로 조절하였으며, 완전이유군은 각 개시일에 포유자의 수를 완전히 이유시켰다. 1. 포유자의 발육상태는 제한포유군에서 정상포유군보다 성장이 유의적 (P<0.05)으로 증가하였고, 또한 분만직후 (RL0) 와 포유 5(RL5), 10(RL10), 15(RLl5) 일에 제한포유를 실시한 군에서는 시간이 경과함에 따라 정상포유군에 비해 유의적 (P<0.05) 으로 증가하였으나, 포유 20 일(RL20) 에 제한포유군에서는 정상포유군과 차이가 없었다 . 초산 rat 의 임신기간은 21.53$\pm$0.04일이었고 산자수는 13.75$\pm$0.07 마리였다. 2. 포유기간 중 모체의 성주기 변화는 정상포유군은 발정징후가 관찰되지 않았으나 분만직후 제한포유군은 20 일을 전후하여 불규칙적인 성주기가 관찰되었고, 분만직후 완전이유군은 10일을 전후하여 정상적인 성주기가 관찰되었다. 3. 정상포유군의 progesterone 농도는 포유 0 일에 33.16$\pm$2.64ng/$m\ell$에서 포유 10 일에 122.55$\pm$3.68ng/$m\ell$ 까지 증가하여 포유 20 일까지 높은 수준을 유지하다가 그 후 25 일에 97.30$\pm$3.21ng/$m\ell$ 까지 급속히 감소 (P<0.05) 하였다. 포유초기 (RL0, RL5)와 포유중기 (RL10)의 제한포유군은 제한포유실시 이후 5일 까지는 정상포유군과 같은 수준을 유지하다가 그 후 급격히 (P<0.05) 감소하였다. 결론적으로 흰쥐에 있어서 분만 후 포유자의 포유자극이 모체 난소의 기능에 중요하게 작용하는 것으로 사료된다.

  • PDF

치아 임플란트 재료에 따른 자기공명영상의 SNR 비교 (Comparison of the SNR in the MR images on dental implant material)

  • 김동현;고성진;예수영
    • 융합신호처리학회논문지
    • /
    • 제16권4호
    • /
    • pp.149-155
    • /
    • 2015
  • 치아 임플란트는 구강 내에 위치하여 목, 뇌 기저부와 안면부 MR 영상에 영향을 미친다. MR 검사에 사용되어지는 자장의 비균일성은 주로 주파수 부호화 방향으로 신호강도의 변화 및 기하학적인 왜곡으로 인공물을 발생시킨다. 본 연구는 치아 임플란트에 의한 왜곡 정도를 자기공명영상의 신호대 잡음비(singal to noise ratio:SNR)를 평가하여 임플란트 영향 정도를 확인하고자 하였다. 이를 위하여 인체와 유사하게 지방, 근육, 물로 구성된 돼지고기 팬텀을 이용하여 신호대 잡음비를 측정하고, 실험을 위해 제작한 고정형 물 팬텀을 이용하여 신호대 잡음비를 측정하여 치아 임플란트 재료 종류에 따른 신호대 잡음비의 크기를 비교 분석하였다. 돼지고기 팬텀의 Brushite, HSA, Metal, RBM 은 T1 SE에서 2.76, 2.22, 1.88, 1.57 이었고, T2 FLAIR에서 1.88, 1.78, 1.65, 1.79, T2 FSE에서 2.28, 2.25, 2.88, 2.05 T2 GRE에서 2.74, 1.94, 1.67, 1.48의 신호대 잡음비가 측정되었다. 고정형 물 팬텀의 Brushite, HSA, Metal, RBM 은 T1 SE에서 1.93, 1.87, 1.93, 2.06, T2 FLAIR에서 1.83, 1.76, 1.82, 1.92 T2 FSE에서 1.85, 1.79, 7.86, 1.97 T2 GRE는 1.97, 1.93, 1.99, 2.06의 신호대 잡음비가 측정되었다. 이러한 결과를 고려해 볼 때, 치아 임플란트의 재료를 선택할 경우 환자와 치과 의사는 치아의 수복이 주된 목적이지만 여러 분야의 검사에 미치는 영향도 고려해야한다. 또한 환자의 치아 임플란트 재료에 따라 검사 프로토콜을 선택하는데 이 연구 결과가 기초자료로 활용될 수 있다.

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF