• 제목/요약/키워드: Chamber width

검색결과 158건 처리시간 0.028초

자동차용 엔진베어링의 최적설계에 관한 해석적 연구 (Analytical Study on the Optimized Design of Engine Bearings for a Passenger Car)

  • 김청균;김한구
    • Tribology and Lubricants
    • /
    • 제25권1호
    • /
    • pp.1-6
    • /
    • 2009
  • In this paper, the minimum oil film thickness and the maximum oil film pressure of engine bearings have been analyzed by using the elastohydrodynamic theory and Taguchi's design method as functions of the oil groove width, oil hole diameter, oil hole position, and oil supply pressure. The optimized design of the engine bearing f3r an automotive Diesel engine is very important for supporting a load-carrying capacity due to gas pres-sures from the engine combustion chamber and inertia forces of the piston. The optimized design data of engine bearings indicated that the optimized oil groove width and an oil diameter of a engine bearing are 8mm at the speed of 2,000 rpm for a given 4-cylinder Diesel engine. Thus, the oil groove oil groove and an oil hole for high performances of an engine bearing may be considered as major design parameters compared to other design factors, which are strongly related to the minimum oil film thickness and the maximum oil pressure distribution of the engine oil.

Comparative Study on Microwave Probes for Plasma Density Measurement by FDTD Simulations

  • Kim, D.W.;You, S.J.;Na, B.K.;Kim, J.H.;Chang, H.Y.;Oh, W.Y.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.218.1-218.1
    • /
    • 2014
  • In order to measure the absolute plasma density, various probes are proposed and investigated and microwave probes are widely used for its advantages (Insensitivity to thin non-conducting material deposited by processing plasmas, High reliability, Simple process for determination of plasma density, no complicate assumptions and so forth). There are representative microwave probes such as the cutoff probe, the hairpin probe, the impedance probe, the absorption probe and the plasma transmission probe. These probes utilize the microwave interactions with the plasma-sheath and inserted structure (probe), but frequency range used by each probe and specific mechanisms for determining the plasma density for each probe are different. In the recent studies, behaviors of each microwave probe with respect to the plasma parameters of the plasma density, the pressure (the collision frequency), and the sheath width is abundant and reasonably investigated, whereas relative diagnostic characteristics of the probes by a comparative study is insufficient in spite of importance for comprehensive applications of the probes. However, experimental comparative study suffers from spatially different plasma characteristics in the same discharge chamber, a low-reproducibility of ignited plasma for an uncertainty in external discharge parameters (the power, the pressure, the flow rate and so forth), impossibility of independently control of the density, the pressure, and the sheath width as well as expensive and complicate experimental setup. In this paper, various microwave probes are simulated by finite-different time-domain simulation and the error between the input plasma density in FDTD simulations and the measured that by the unique microwave spectrums of each probe is obtained under possible conditions of plasma density, pressure, and sheath width for general low-temperature plasmas. This result shows that the each probe has an optimum applicable plasma condition and reliability of plasma density measurement using the microwave probes can be improved by the complementary use of each probe.

  • PDF

A retrospective institutional study of human age determination by evaluating the pulp length and width ratio of the maxillary lateral incisor on panoramic radiographs in Indonesian subjects

  • Herianti, Vanessa Rizka;Oscandar, Fahmi;Dardjan, Murnisari
    • Imaging Science in Dentistry
    • /
    • 제51권4호
    • /
    • pp.421-427
    • /
    • 2021
  • Purpose: The pulp length to width (PL/W) ratio of the maxillary lateral incisor can be used as an age determination method. This study aimed to investigate the correlation between the PL/W ratio of the maxillary lateral incisor on panoramic radiographs and human chronological age in Indonesian subjects. Materials and Methods: This study analyzed with 134 maxillary lateral incisors on 113 panoramic radiographs from patients who visited the Oral and Maxillofacial Radiology Unit of Dental Hospital Universitas Padjadjaran, Bandung, Jawa Barat, Indonesia, from 2013 to 2018 (age range: between 11 to 60 years). The pulp length was measured from the pulp chamber roof to the apical foramen, and the pulp width was measured on the cervical area of the cementoenamel junction in millimeters using Fiji ImageJ open-source software. Simple linear regression (in SPSS) was used to analyze the results. The reliability of the observers was evaluated. Results: The PL/W ratio of the maxillary lateral incisor was significantly correlated with chronological age (P<0.01). No statistically significant difference was found in the PL/W ratio between the left and right maxillary lateral incisors(P=0.333). There was a very strong correlation (r=0.939) between the PL/W ratio of the maxillary lateral incisor and human chronological age, with the following formula: age= -3.057+1.875×PL/W ratio (R2=0.882, standard error of estimate: 4.659). Conclusion: The PL/W ratio of the maxillary lateral incisor on panoramic radiograph can be used for age determination in Indonesian subjects.

Quality Change in Plug Seedlings of Three Indigenous Medicinal Plants after Short-term Cold Storage

  • Oh, Hye Jin;Park, Ji Eun;Park, Yoo Gyeong;Jeong, Byoung Ryong
    • 한국자원식물학회지
    • /
    • 제26권6호
    • /
    • pp.701-708
    • /
    • 2013
  • To test the quality change of seedlings of three domestic medicinal plants raised in plug trays, a short term storage experiment was conducted. Seedlings were kept in growth chambers for two weeks at 4 or $8^{\circ}C$ temperature combined with 0 or $5{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ PPFD. Quality of glasshouse-raised seedlings was assessed after two weeks of cold storage in the growth chamber and one week of acclimation in the greenhouse. After two weeks of storage in the growth chamber of Perilla frutescens var. acuta Kudo, plant height was the greatest in the treatment $8^{\circ}C$ combined with $0{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ PPFD. Internode length of P. frutescens var. acuta Kudo was the greatest in the treatment of $4^{\circ}C$ combined with $0{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ PPFD. After one week of acclimatization in a glasshouse, the growth and development, such as plant height, internode length and leaf size, were greater in the $8^{\circ}C$ combined with $5{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ PPFD than in the other treatments. After two weeks of storage in the growth chamber of Sophora tonkinensis, plant height increased more in the treatment of $4^{\circ}C$ than $8^{\circ}C$. After one week of acclimatization in a glasshouse, number of leaves did not change in the treatment of $4^{\circ}C$ combined with $0{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ PPFD, but it increased in the other treatments. Leaf width increased more under the dark than light condition. Leaf length did not observably change in any treatments. After two weeks of storage in the growth chamber, plant height of Angelica gigas Nakai was the greatest in the treatment of $8^{\circ}C$. Number of leaves was the greatest in the treatment of $8^{\circ}C$. Leaf growth was greater under dark than light condition. These results suggested that optimal storage environment was $8^{\circ}C$ combined with $5{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ PPFD for P. frutescens var. acuta Kudo, and $4^{\circ}C$ combined with $0{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ PPFD for S. tonkinensis and A. gigas Nakai. Hence, proper combination of temperature and PPFD were necessary for better storage, and acclimatization and growth, thereafter, of the plug seedlings of theses plant species.

전투차량 흡기시스템의 압력손실에 관한 수치적 연구 (A Computational Study on the Pressure Loss of Intake System for the Combat Vehicle)

  • 문성목;안수홍;이경훈;우관제
    • 한국유체기계학회 논문집
    • /
    • 제15권3호
    • /
    • pp.25-31
    • /
    • 2012
  • A computational study on the improvement of the pressure loss of intake system, which is located at engine manifold of the combat vehicle, has been conducted using a finite-volume-based, Reynolds-Averaged Navier-Stokes (RANS) solver. The computational result of the pressure loss through the air cleaner is in good agreement with equivalent experimental data. A parametric study was done for improving of the pressure loss of intake system over the baseline case. The effects of five primary parameters such as the height of inlet, the width of interconnection pipe, the shape of drain chamber and the diameter of filter housing were considered in this study. Consequently, this computational investigation can contribute to finding an optimal guideline for the idea of improvement in the pressure loss of intake system.

승용차 공조계용 블로우어의 음향출력 평가에 관한 연구 (A Study on the Acoustic Power Estimation in the Blower for a Vehicle Air-handling System)

  • 김석현;유성우
    • 산업기술연구
    • /
    • 제17권
    • /
    • pp.87-93
    • /
    • 1997
  • A Special purpose program, based on the dimensional analysis, was developed to estimate the wide band turbulent noise in the blower of vehicle airhandling system. Acoustic power level was measured at 4 rating points around the operating condition. The experiment was performed on the reference blower model using international standard chamber, which could measure acoustic power according to the air-handling performance. Analytical model of the blower noise was determined by the measured data. Using the analytical acoustic model, it was possible to estimated the effect by the change of the operating condition, such as flow rate, static pressure and wheel rotating speed, furthermore, the diameter and the width of blower.

  • PDF

고온고압용기에서 충돌분무 특성에 관한 실험적 연구 (An Experimental Studies on Impingement Spray Characteristic in High Temperature and Pressure Chamber)

  • 안병규;류호성;오은탁;송규근;정재연
    • 한국자동차공학회논문집
    • /
    • 제10권3호
    • /
    • pp.36-43
    • /
    • 2002
  • The characteristics of spray has much effect on performance and emissions for automobile, diesel engine, gas turbine and combustion engines. So spray behavior after impinging the wall is very important for prediction the engine performance. This studies examined about impingement spray considering ambient density(18,24,30kg/ms), temperature(293,473K), impingement angle(0,30,45°). The images of impingement spray were obtained by the high speed video camera. After that we analyzed impingement spray characteristics to use this images. In this experiment, we found that 1) The spray width is reduced by increasing the ambient gas density and temperature,2) The growth of downstream is increased by increasing the impingement angle.

직분식 가솔린기관 인젝터의 연료 분무 특성 (Fuel Spray Characteristics of GDI Injector)

  • 권상일;이창식
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2000년도 제21회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.194-201
    • /
    • 2000
  • This paper is intended to analyze the macroscopic behavior and transient atomization characteristics of the high-pressure gasoline injector in direct-injection gasoline engine. The global spray behavior of fuel injector was visualized by shadowgraph technique. Time-resolved droplet axial and radial velocity components and droplet diameter were measured at many probe positions in both axial and radial directions by a two-component phase Doppler particle analyzer (PDPA). In order to obtain the influence of fuel injection pressure, the macroscopic visualization and experiment of particle measurement on the fuel spray were investigated at 3,5 and 7 MPa of injection pressure under different surrounding pressure in the spray chamber. The results of this work show that the fuel injection pressure of gasoline injector in GDI engine has influence upon the mean droplet diameter, mean velocity of spray droplet, the spray tip penetration, and spray width under the elevated ambient pressure.

  • PDF

풍력터빈 성능시험을 위한 저속풍동 개념연구 (Conceptual Study of a Low-Speed Wind Tunnel for Performance Test of Wind Turbine)

  • 강승희
    • 한국항공운항학회지
    • /
    • 제19권4호
    • /
    • pp.24-29
    • /
    • 2011
  • Conceptual study of an open-circuit type low-speed wind tunnel for performance test of wind turbine blade and airfoil is conducted. The tunnel is constituted of a settling chamber, a contraction, closed test section, a diffuser, two corners, a cross leg and a fan and motor. For the performance test, the closed test section width of 1.8 m, height of 1.8 m and length of 5.25 m is selected. The contraction ratio is 9 to 1 and maximum speed in the test section is 67 m/sec. Input power in the tunnel is about 238 kW and its energy ratio is 3.6. The wind tunnel designed in present study will be an effective tool in research and development of wind turbine and airfoil.

Fatigue Test of MEMS Device: a Monolithic Inkjet Print

  • Park, Jun-Hyub;Oh, Yong-Soo
    • Journal of Mechanical Science and Technology
    • /
    • 제18권5호
    • /
    • pp.798-807
    • /
    • 2004
  • A testing system was developed to improve the reliability of printhead and several printheads were tested. We developed a thermally driven monolithic inkjet printhead comprising dome-shaped ink chambers, thin film nozzle guides, and omega-shaped heaters integrated on the top surface of each chamber. To perform a fatigue test of an inkjet printhead, the testing system automatically detects a heating failure using a Wheatstone bridge circuit. Various models were designed and tested to develop a more reliable printhead. Two design parameters of the width of reinforcing layer and heater were investigated in the test. Specially., the reinforcing layer was introduced to improve the fatigue life of printhead. The life-span of heater with a reinforcing layer was longer than that without a reinforcing layer. The wider the heater was, the longer the life of printhead was.