• Title/Summary/Keyword: Chamber Status

Search Result 71, Processing Time 0.024 seconds

Changes of Particle Filtration Efficiency of Cloth Masks by Machine Washing and Cloth Expansion (세탁 및 옷감 신장에 따른 천마스크 제품의 여과효율 변화)

  • Kim, Seung Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.2
    • /
    • pp.115-122
    • /
    • 2017
  • Objectives: This study was designed to evaluate the changes in the particle filtration efficiencies of five cloth masks (4 plate types, 1 cup type) with an increasing number of machine washings and the degree of cloth expansion. Methods: NaCl aerosols were generated using an atomizer and passed through cloth masks in a dynamic aerosol chamber. Particle concentrations were measured both before and after for the cloth masks using an optical particle counter (OPC) in the size range of $0.3{\sim}10{\mu}m$. Results: In the original condition, the filtration efficiencies of the five cloth masks were A: 20.1%, B:30.9%, C: 25.0%, D: 26.5%, and E: 40.9%. As the number of washings increased in the order of one, two, and four times, the filtration efficiencies of cloth mask C increased. The filtration efficiency of A, D, and E increased after the first washing. With the exception of B, the filtration efficiency of cloth masks increased after the second washing and those of all cloth masks increased after the fourth washing. This might be caused by the fibers untangling from the yarn and being freed at one end. In this status, the packing density of the textile will not change, but the distances between fibers will increase, which might bring about an increase in filtration efficiency. When the cloth masks were extended by 10% and 20% in one direction, the filtration efficiencies of cloth masks B, D, and E decreased at 10% extension, and those of all cloth masks decreased at 20% extension. When the cloth masks were expanded by 10% and 20% in two directions, the filtration efficiencies of all cloth masks decreased by at least 34.7% at 10% extension, and by at least 60.9% at 20% extension Conclusions: The filtration efficiency of cloth masks could decrease after one to two machine washings, but will increase after four washings in comparison with their original performances. The filtration efficiency of cloth masks will decrease when they are expanded, such as when stretching over the nose during wearing status.

Postoperative Transesophageal Echocardiographic Evaluation in Patients with Cardiac Valve Replacement (경식도 심초음파 검사를 이용한 판막대치술 환자의 평가)

  • 조건현
    • Journal of Chest Surgery
    • /
    • v.24 no.3
    • /
    • pp.265-270
    • /
    • 1991
  • Since advent of the prosthetic cardiac valve replacement, much efforts for accurate assessing value function in-vivo have been attempted. To evaluate the postoperative functional and morphological status of the replaced cardiac valve prosthesis, 33 patients with valve replacement were studied by transthoracic and transesophageal 2-dimensional echocardiac imaging as well as by color Doppler flow velocity imaging. Twenty four patients had mitral valve replacement. 6 patients had aortic valve replacement and 3 patients had both mitral and aortic valve replacement. There were 34 mechanical and 2 biological prosthesis. Comparing to transthoracic echocardiography, transesophageal approach showed transvalvular regurgitant jet flow amid the prosthetic mitral valve ring during. systole and much clear visualization of cardiac chamber behind prosthesis which could give shadowing effect to ultrasound beam. According to the quantitative grading by the length and area of mitral regurgitant flow, 24 out of 27 mitral valves revealed mild degree regurgitation considered as physiological after prosthetic bileaflet valve replacement and the other 3 valves including 2 biological prosthesis had moderate degree regurgitation which was regarded as pathologic one. 2 cases of left atrial thromboses and 1 case of paravalvular leakage which were not visible by transthoracic approach were identified by transesophageal echocardiography in patients with mitral valve replacement and patients with aortic valve replacement respectively. We conclude that in patients with prosthetic mitral valve replacement, transesophageal 2-dimensional imaging with color Doppler can suggest reliable information beyond that available from the transthoracic access even though it gives patient some discomfort to proceed.

  • PDF

A Comparative Study on the Effectiveness among the International Practices of the Credit Transactions (국제신용장관습간의 효력관계에 관한 비교검토)

  • Seo, Jung-Doo
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.41
    • /
    • pp.25-50
    • /
    • 2009
  • In this article, I have reviewed the definition of international mercantile customs, their preferential application, the developing status of the credit practice, the effectiveness and relationship of the international standard banking practices, e.g. UCP 600 and ISBP 2007, ISP98, URR 725, eUCP 1.1. and the like, established by the International Chamber of Commerce (ICC). It is important to emphasize that the autonomous agreements between the credit parties and the international practice on the credit transaction are respected above all because of the special nature of its transaction. When we want to apply to a letter of credit by the international rules - UCP 600, ISP98, URDG, URR 725 and eUCP 1.1, we must indicate expressly in the text of the credit that it is subject to the respective rule. But the International Standard Banking Practice, 2007 revised by the ICC is applicable to without its indication in case of the UCP 600 credit. On the other hand, the UN Convention on Guarantees and Standby Credits applies to an international undertaking referred to in its article 2, (a) if the guarantor/issuer is in a Contracting State, or (b) if the rules of private international law lead to the application of the law of a Contracting State, unless the undertaking excludes the application of the Convention. And this Convention applies also to an international credit not falling within its article 2, if it expressly states that it is subject to this Convention.

  • PDF

Design and Application of Emergency Blockage System for Engine Part at IPPT and SQT (IPPT, SQT에서의 엔진부 비상정지 시스템 설계 및 운용)

  • 하성업;이중엽;정태규;한상엽
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.7 no.2
    • /
    • pp.44-53
    • /
    • 2003
  • A vertical hot-firing test facility was established to carry out the IPPT(Integrated Propulsion Performance Test) and SQT(Stage Qualification Test) of KSR-III(Korea Sounding Rocket-III). The components for actual launcher were mostly used, hence these tests were carried out under the condition of relatively lower safety margin. To perform hot-firing tests with the maximum safety, an engine emergency blockage system was investigated and applied. An emergency blockage system using combustion chamber pressures and acceleration signals was set up to monitor ignition delay and fail, flame out, propellant feeding status, unstable combustion and excessive structural vibration. With such a system, the test safety could be secured by rapid judgement and follow-up measures, which made IPPT and SQT be safely completed.

Application of an Artificial Neural Network Model to Obtain Constitutive Equation Parameters of Materials in High Speed Forming Process (고속 성형 공정에서 재료의 구성 방정식 파라메터 획득을 위한 인공신경망 모델의 적용)

  • Woo, M.A.;Lee, S.M.;Lee, K.H.;Song, W.J.;Kim, J.
    • Transactions of Materials Processing
    • /
    • v.27 no.6
    • /
    • pp.331-338
    • /
    • 2018
  • Electrohydraulic forming (EHF) process is a high speed forming process that utilizes the electric energy discharge in fluid-filled chamber to deform a sheet material. This process is completed in a very short time of less than 1ms. Therefore, finite element analysis is essential to observe the deformation mechanism of the material in detail. In addition, to perform the numerical simulation of EHF, the material properties obtained from the high-speed status, not quasi static conditions, should be applied. In this study, to obtain the parameters in the constitutive equation of Al 6061-T6 at high strain rate condition, a surrogate model using an artificial neural network (ANN) technique was employed. Using the results of the numerical simulation with free-bulging die in LS-DYNA, the surrogate model was constructed by ANN technique. By comparing the z-displacement with respect to the x-axis position in the experiment with the z-displacement in the ANN model, the parameters for the smallest error are obtained. Finally, the acquired parameters were validated by comparing the results of the finite element analysis, the ANN model and the experiment.

Analysis of Fulfillment Status on Environment·Landscape Damage Reduction and Disaster Prevention in Quarry Related to Mountainous Districts Management Act (산지관리법에 명시된 토석채취지의 환경·경관피해 및 재해저감 관련 법 조항의 이행실태 분석)

  • Park, Jae-Hyeon;Kim, Ki-Dae;Bae, O-Jang
    • Journal of Korean Society of Forest Science
    • /
    • v.106 no.2
    • /
    • pp.196-203
    • /
    • 2017
  • Quarrying industry is typical industry that troubled between the market and government regulations in the forestry. Especially, it is difficult to consider aspects of economics and environment, landscape, disaster at the same time. Therefore, Quarrying industry need revised statutes according to regulatory reform and mitigation. This study conducted to provide basic data for regulatory reform and mitigation in quarrying industry. We surveyed 22 article of mountainous districts management act and lower statutes to employers and business interests on quarry 55 places in the Republic of Korea. As a result, fulfillment status of environmental damage reduction and disaster prevention were satisfactory. But fulfillment status of landscape damage reduction were not applicable. This result is due to the social mood that emphasizes the forest landscape. But there is need to improve the efficiency of grit chamber through present standard on effluent(water pollution prevention). In conclusion, policies should be established for realistic regulation and developed industry to quarrying industry.

A Study on Citizen Perceptions of the Gwangyang Steel and Iron Company: focus on CFI (광양제철소에 대한 지역 시민들의 기업이미지 분석: CFI를 이용하여)

  • Kim, Chang-Gon;Kim, Myung-Soo
    • Journal of Distribution Science
    • /
    • v.11 no.1
    • /
    • pp.35-44
    • /
    • 2013
  • Purpose - This study aims to (a) analyze local citizens' perception of a local company, the Gwangyang Steel and Iron Company (GSIC); (b) compare the perception toward the local company with that of national citizens' perceptions towards many other unspecified companies, which were surveyed biannually by The Korea Chamber of Commerce and Industry (KCCI); and (c) analyze how such companies evaluate perceptions towards them, in relation to citizens' socioeconomic position, such as their education status. Research design, data, methodology - The data were collected using a questionnaire, which was given to a sample of local citizens in cities. To test the hypotheses, factor analyses, a t-test, and an ANOVA were conducted. The total number of respondents was 1798. The data gathered from the respondents of the sample were analyzed using SPSS Win 19.0 software. Perception towards the company was evaluated on the corporate favorite index (CFI). The CFI index shows how positive citizens feel towards a company. It is calculated using five leading factors, consisting of the following: contribution to the economy, productivity, international competitiveness, social contribution, and ethical management. The higher the level of positive feelings exhibited, the closer the index will come to 100. Results - As a result of the analysis, the CFI index towards the GSIC stood at 67.3. The CFI index towards the company is 16.5 points higher than that of the index towards the many other unspecified companies, which were surveyed by the bi-annual KCCI study in the first half of 2011. The other five indexes stood as follows: contribution to the economy, productivity, social contribution, and ethical management was 69.2, 71.2, 64.6, and 58.6, respectively. These indexes are 18.3, 4.6, 27.6, and 35.6, respectively, higher than those found by the KCCI study. However, international competitiveness is 73.0 (9.8 points lower than that of the KCCI study). This survey thus shows that the CFI of the local citizens towards the global company GSIC is very high when compared with the CFI index towards the many other unspecified companies that was determined by the KCCI survey. Conclusions - This survey shows that local citizens have high expectations of economic activity, increasing working opportunities, and regional cooperation projects from the local company, GSIC. In addition, the CFI index towards GSIC evaluates results depending on the respondent's relationship with the company, and their educational status. Respondents, whose family or relatives were working as employees of GSIC, have relatively positive perceptions of GSIC, and respondents with a relatively higher educational status also share positive perceptions. Local citizens expect the profit-making of the company to operate in accordance with management activities, and at the same time, they expect that the wealth generated by the company will return to wider society.

  • PDF

Report of Present Status of Calibration for Domestic Radiation Measurements Instruments (국내 방사선 측정장비 보유 현황 및 교정 현황 조사)

  • Lim, Sangwook;Choi, Jinho;An, Sohyun;Cho, Kwang Hwan;Lee, Sang Hoon;Lee, Rena;Cho, Sam Ju
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.46-53
    • /
    • 2016
  • Periodical calibrations of radiation detectors are important for accurate quality assurance of therapeutic linac. The measuring instruments such as ion-chamber, thermometer, barometer, and survey meter should be calibrated periodically. Period of calibration for these instruments is suggested 6 month to one year in Korea and two years in other countries nowadays. Therefore, the determination of reasonable period for calibration is needed. In this study, we plan to utilize the results of these survey; frequent in use, how to use and stability of instruments, to determine the optimized period of calibration for the instruments in the departments of radiation oncology in Korea based on the ILAC-G24. The SurveyMonkey web-based survey tool was used and the objects of survey were 18 department of radiation oncology in university hospitals, and 15 departments were answered. The 64 questionnaires which supposed to be answered in 50 minutes were classified as the information of candidates, the thermometer, the barometer, the surveymeter, and the ion-chamber. The thermometers and the barometers were not under periodical calibration for more than half of candidates. The periods of calibration of surveymeters were 6 month to 1 year. We expect that the calibration period can be determined based on these survey results.

The Development of a Multi-Purpose Irradiator and the Characteristic of Dose Distribution (다목적 방사선 조사장치 개발 및 선량분포특성)

  • Lee, Dong-Hoon;Ji, Young-Hoon;Lee, Dong-Han;Kim, Yoon-Jong;Hong, Seung-Hong
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.39 no.6
    • /
    • pp.42-48
    • /
    • 2002
  • The design, construction and performance test of a convenient multi-purpose irradiator is described. A multi-purpose irradiator using Cesium-137 has been developed for studies of low dose radiation effects in biology and for calibration of Thermo Luminescent dosimeter(TLD). During the operation, three rods of radioactive material which are 10cm in length revolve 180 degrees and irradiate biological samples, or TLD, and return to their shielded position, after the programmed time. A programmable Logic Controller(PLC) controls the sequence of operation, interlock, motor rotation and safety system. The rotation speed of biological samples can vary up to 20 RPM. A real time monitoring system was also incorporated to check and control the operation status of the irradiator. The capacity of the irradiation chamber was 4.5 liters. The isodose distribution at arbitrary vertical planes was measured by using film dosimetry. The dose-rate was 0.13 cGy/min in air and 0.11 cGy/min in water equivalent material in the case of Cesium-137. Range of activity was 2 Ci. The homogeneity of dose distribution in the chamber was ${\pm}$7%. The actual radiation level on the surface was within permissible levels. The irradiator had a maximum 0.35 mR/min radiation leakage on its surface.

Development of Neutron, Gamma ray, X-ray Radiation Measurement and Integrated Control System (중성자, 감마선, 엑스선 방사선 측정 및 통합 제어 시스템 개발)

  • Ko, Tae-Young;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.21 no.4
    • /
    • pp.408-411
    • /
    • 2017
  • In this paper, we propose an integrated control system that measures neutrons, gamma ray, and x-ray. The proposed system is able to monitor and control the data measured and analyzed on the remote or network, and can monitor and control the status of each part of the system remotely without remote control. The proposed system consists of a gamma ray/x-ray sensor part, a neutron sensor part, a main control embedded system part, a dedicated display device and GUI part, and a remote UI part. The gamma ray/x-ray sensor part measures gamma ray and x-ray of low level by using NaI(Tl) scintillation detector. The neutron sensor part measures neutrons using Proportional Counter Detector(low-level neutron) and Ion Chamber Type Detector(high-level neutron). The main control embedded system part detects radiation, samples it in seconds, and converts it into radiation dose for accumulated pulse and current values. The dedicated display device and the GUI part output the radiation measurement result and the converted radiation amount and radiation amount measurement value and provide the user with the control condition setting and the calibration function for the detection part. The remote UI unit collects and stores the measured values and transmits them to the remote monitoring system. In order to evaluate the performance of the proposed system, the measurement uncertainty of the neutron detector was measured to less than ${\pm}8.2%$ and the gamma ray and x-ray detector had the uncertainty of less than 7.5%. It was confirmed that the normal operation was not less than ${\pm}15$ percent of the international standard.