• 제목/요약/키워드: Chairside

검색결과 38건 처리시간 0.023초

Dental biomaterials for chairside CAD/CAM: State of the art

  • Lambert, Hugo;Durand, Jean-Cedric;Jacquot, Bruno;Fages, Michel
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권6호
    • /
    • pp.486-495
    • /
    • 2017
  • The wide use of chairside CAD/CAM restorations has increased the diversity of the restorative material. For the practitioner, the selection of the appropriate material is difficult amongst the variety offered by the market. Information on the characteristics of the products can be difficult to assess due to the lack of up-to-date classification and the lack of reliability of manufacturer's advertising. The purpose of this article is to structure the data on restorative materials provided by various sources in order for the practitioner to choose the product most suited to the clinical situation. The objective is to classify chairside CAD/CAM materials and to define their characteristics and indications.

Autogenous fresh demineralized tooth graft prepared at chairside for dental implant

  • Kim, Eun-Seok
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제37권
    • /
    • pp.8.1-8.6
    • /
    • 2015
  • Background: This study aimed to evaluate the clinical usefulness of autogenous fresh demineralized tooth (auto-FDT) graft prepared at the chairside for alveolar bone grafting during dental implant surgery. Methods: In total, 38 patients requiring both tooth extraction (for endodontic or periodontal reasons or third molar extraction) and alveolar bone regeneration for dental implant placement were included. Within 2 h after clean extraction, the teeth were prepared at the chairside to serve as bone graft material. In the same sitting, blocks or chips of this graft material were used to reconstruct defects at the osteotomy site simultaneously with or before implant placement. Twelve months after prosthesis fabrication and placement, the clinical findings and implant success rates were evaluated. Histological studies were randomly conducted for selected cases. Results: Clinical evaluation showed favorable wound healing with minimal complications and good bone support for the implants. No implant was lost after 12 months of function following prosthetic rehabilitation. Histological examination revealed new bone formation induced by the graft material. Conclusions: Chairside preparation of autogenous fresh demineralized teeth after extraction can be a useful alternative to the use of autogenous bone or other graft materials for the immediate reconstruction of alveolar bone defects to facilitate subsequent implant placement.

An alternative treatment option for a bony defect from large odontoma using recycled demineralization at chairside

  • Lee, JuHyon;Lee, Eun-Young;Park, Eun-Jin;Kim, Eun-Suk
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제41권2호
    • /
    • pp.109-115
    • /
    • 2015
  • Odontoma is the most common odontogenic benign tumor, and the treatment of choice is generally surgical removal. After excision, bone grafts may be necessary depending on the need for further treatment, or the size and location of the odontoma. Although the osteogenic capacity of a demineralized tooth was verified as early as 1967 by Urist and many other investigators, the cumbersome procedure, including a long demineralization time, may be less than comfortable for clinicians. A modified ultrasonic technology, with periodic negative pressure and temperature control, facilitated rapid and aseptic preparation of demineralized teeth for bone grafts. This approach reduces the demineralization time dramatically (${\leq}80$ minutes), so that the graft material can be prepared chairside on the same day as the extraction. The purpose of this article is to describe two cases of large compound odonotomas used as graft material prepared chairside for enucleation-induced bony defects. These two clinical cases showed favorable wound healing without complications, and good bony support for future dental implants or orthodontic treatment. Finally, this report will suggest the possibility of recycling the benign pathologic hard tissue as an alternative treatment option for conventional bone grafts in clinics.

치과위생사의 기대업무와 수행업무 격차가 이직의도와 직무만족도에 미치는 영향 (Effect of Gap between Expected Job and Performed Job on Turnover Intention and Job Satisfaction in Clinical Dental Hygienists)

  • 최하나;배현숙;조영식
    • 치위생과학회지
    • /
    • 제11권5호
    • /
    • pp.463-469
    • /
    • 2011
  • 본 연구는 치과위생사의 기대업무 수준과 수행업무 수준의 차이가 직무만족도와 이직의도에 미치는 효과를 평가하기 위하여 의료기관에서 근무하는 치과위생사 2,655명을 편의추출하여 우편설문조사를 실시한 결과 612명이 회신하였다. 이 가운데 이직경험이 없는 치과위생사 295명을 대상으로 최종 분석하였다. 진료보조업무, 예방업무, 상담업무, 접수업무 등 네 가지 업무영역별로 기대업무 수준과 수행업무 수준의 격차를 측정하였다. 조사대상자의 일반적 특성, 사회인구학적 특성 및 직무관련 특성에 따른 기대업무와 수행업무 격차를 알아보기 위하여 독립표본 t 검정과 일원분산분석(ANOVA)를 수행하였다. 직무만족도에 영향을 미치는 요인과 이직의도에 영향을 미치는 요인을 알아보기 위하여 다중회귀분석을 실시하였다. 그 결과 다음과 같은 결론을 얻었다. 1. 연령과 근무경력에 따라 진료보조업무의 기대-수행업무 격차(p<0.01)와 접수업무의 기대-수행업무 격차(p<0.05)가 나타났다. 또한 연령, 근무경력, 학력에 따라 상담업무의 기대-수행업무 격차가 나타났다(p<0.01). 예방업무의 기대-수행업무 격차는 나타나지 않았다. 2. 직무만족도에 영향을 미치는 요인은 진료보조업무(${\beta}$=0.163, t=3.102, p=0.002), 급여만족도(${\beta}$=0.538, t=10.788, p=0.000), 월차유무(${\beta}$=0.115, t=2.244, p=0.026)로 나타났다. 모형의 결정계수($R^2$)는 0.608로써 통계적으로 유의하였다(F=12.162, p=0.000). 3. 이직의도에 영향을 미치는 요인은 자녀유무(${\beta}$=-0.254, t=-2.711, p=0.007), 진료보조업무 격차(${\beta}$=-0.186, t=-3.162, p=0.002), 급여만족도(${\beta}$=-0.313, t=-5.623, p=0.000)로 나타났다. 모형의 결정계수($R^2$)는 0.466으로써 유의한 것으로 나타났다(F=5.749, p=0.000). 결론적으로, 급여만족도와 진료보조업무격차가 이직의도와 직무만족도에 영향을 미치고 있으며, 월차유무는 직무만족도에 영향을 미치나 이직의도에는 영향을 미치지 않았다.

연마방법에 따른 탄성의치의 표면거칠기와 $Candida$ $albicans$의 부착율 변화 (Surface roughness and $Candida$ $albicans$ adhesion to flexible denture base according to various polishing methods)

  • 오주원;서재민;안승근;박주미;강철균;송광엽
    • 대한치과보철학회지
    • /
    • 제50권2호
    • /
    • pp.106-111
    • /
    • 2012
  • 연구 목적: 본 연구는 탄성의치 제작 시 주로 사용되는 polyamide를 수종의 연마방법을 사용하여 처리 후 $Candida$ $albicans$의 부착정도와 표면거칠기를 비교하고자 하였다. 연구 재료 및 방법: $25{\times}15{\times}2mm$ 크기의 polyamide 시편을 4군으로 나누어 연마재를 사용하여 기공용 lathe 연마하는 방법(기공실내 연마방법)과 각기 다른 2종의 실리콘 포인트로 진료실내 연마하는 방법, 그리고 실리콘포인트 연마 후 pumice로 연마하는 방법으로 처리하였다. $C.$ $albicans$의 부착성을 평가하기 위해 $5{\times}10^6CFU/ml$$C.$ $albicans$ 현탁액에 시편을 2시간 동안 침적하였고 5회 수세처리 후 한천배지에서 배양하였다. 그리고 주사전자 현미경(JSM-5900, JEOL LTd., Tokyo, Japan) 촬영을 시행하였다. Profilometer (Surf-pak; Kawasaki, Japan)를 이용하여 표면거칠기를 측정하였고 통계처리를 위하여 SPSS 18.0 프로그램을 사용하였다. 일원변량분석으로 비교 분석하였고 사후 검증은 $C.$ $albicans$의 부착성 검증을 위해 Scheffe test를 시행하였으며 표면조도검증을 위해 Tamhane's T2 test를 시행하였다(${\alpha}$=.01). 결과: 최대 거칠기 값을 보인 군은 2단계의 연마용 버를 사용한 것으로 $0.32{\mu}m{\pm}0.10$ 값을 나타냈으며, 가장 낮은 거칠기 값을 보인 것은 tungsten carbide를 사용하지 않고 기공용 lathe로만 연마를 한 군으로 $0.02{\mu}m{\pm}0.00$의 거칠기 값을 나타냈다. $C.$ $albicans$ 부착 실험에서는 기공용 lathe만을 이용한 연마방법이 가장 적은 부착수를 보였으며 다른 세 군과 유의한 차이가 발견되었다($P$<.01). 결론: 표면거칠기 및 미생물 부착능 실험 결과 기공실 연마만을 시행한 경우 유의하게 낮은 거칠기 값과 부착율을 보였다. Pumice로 추가 연마한 군은 진료실연마를 시행한 군에 비해 낮은 거칠기 값을 보였으나 $C.$ $albicans$ 부착에 있어서는 유의한 차이를 보이지 않았다($P$>.01).

Association of chairside salivary aMMP-8 findings with periodontal risk assessment parameters in patients receiving supportive periodontal therapy

  • Schmalz, Gerhard;Kummer, Max Kristian;Kottmann, Tanja;Rinke, Sven;Haak, Rainer;Krause, Felix;Schmidt, Jana;Ziebolz, Dirk
    • Journal of Periodontal and Implant Science
    • /
    • 제48권4호
    • /
    • pp.251-260
    • /
    • 2018
  • Purpose: The aim of this retrospective cross-sectional study was to evaluate whether salivary findings of active matrix-metalloproteinase 8 (aMMP-8) chairside (point of care; POC) tests were associated with periodontal risk assessment parameters in patients receiving supportive periodontal therapy (SPT). Methods: A total of 125 patients receiving regular SPT were included, and their records were examined. The following inclusion criteria were used: a diagnosis of chronic periodontitis, at least 1 non-surgical periodontal treatment (scaling and root planning) with following regular SPT (minimum once a year), at least 6 remaining teeth, and clinical and aMMP-8 findings that were obtained at the same appointment. In addition to anamnestic factors (e.g., smoking and diabetes), oral hygiene indices (modified sulcus bleeding index [mSBI] and approximal plaque index), periodontal probing depth simultaneously with bleeding on probing, and dental findings (number of decayed, missing, and filled teeth) were recorded. Salivary aMMP-8 levels were tested using a commercial POC test system (Periomarker, Hager & Werken, Duisburg, Germany). Statistical analysis was performed using the t-test, Mann-Whitney U test, Fisher's exact test, and ${\chi}^2$ test, as appropriate (P<0.05). Results: Only the mSBI was significantly associated with positive salivary aMMP-8 findings (aMMP-8 positive: $27.8%{\pm}20.9%$ vs. aMMP-8 negative: $18.0%{\pm}14.5%$; P=0.017). No significant associations were found between aMMP-8 and smoking, diabetes, periodontal parameters, or parameters related to the maintenance interval (P>0.05). Conclusions: Salivary aMMP-8 chairside findings were not associated with common parameters used for periodontal risk assessment in patients receiving SPT. The diagnostic benefit of POC salivary aMMP-8 testing in risk assessment and maintenance interval adjustment during SPT remains unclear.

In vitro performance and fracture resistance of novel CAD/CAM ceramic molar crowns loaded on implants and human teeth

  • Preis, Verena;Hahnel, Sebastian;Behr, Michael;Rosentritt, Martin
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권4호
    • /
    • pp.300-307
    • /
    • 2018
  • PURPOSE. To investigate the fatigue and fracture resistance of computer-aided design and computer-aided manufacturing (CAD/CAM) ceramic molar crowns on dental implants and human teeth. MATERIALS AND METHODS. Molar crowns (n=48; n=8/group) were fabricated of a lithium-disilicate-strengthened lithium aluminosilicate glass ceramic (N). Surfaces were polished (P) or glazed (G). Crowns were tested on human teeth (T) and implant-abutment analogues (I) simulating a chairside (C, crown bonded to abutment) or labside (L, screw channel) procedure for implant groups. Polished/glazed lithium disilicate (E) crowns (n=16) served as reference. Combined thermal cycling and mechanical loading (TC: $3000{\times}5^{\circ}C/3000{\times}55^{\circ}C$; ML: $1.2{\time}10^6$ cycles, 50 N) with antagonistic human molars (groups T) and steatite spheres (groups I) was performed under a chewing simulator. TCML crowns were then analyzed for failures (optical microscopy, SEM) and fracture force was determined. Data were statistically analyzed (Kolmogorow-Smirnov, one-way-ANOVA, post-hoc Bonferroni, ${\alpha}=.05$). RESULTS. All crowns survived TCML and showed small traces of wear. In human teeth groups, fracture forces of N crowns varied between $1214{\pm}293N$ (NPT) and $1324{\pm}498N$ (NGT), differing significantly ($P{\leq}.003$) from the polished reference EPT ($2044{\pm}302N$). Fracture forces in implant groups varied between $934{\pm}154N$ (NGI_L) and $1782{\pm}153N$ (NPI_C), providing higher values for the respective chairside crowns. Differences between polishing and glazing were not significant ($P{\geq}.066$) between crowns of identical materials and abutment support. CONCLUSION. Fracture resistance was influenced by the ceramic material, and partly by the tooth or implant situation and the clinical procedure (chairside/labside). Type of surface finish (polishing/glazing) had no significant influence. Clinical survival of the new glass ceramic may be comparable to lithium disilicate.

Effect of surface treatment on shear bond strength of relining material and 3D-printed denture base

  • Park, Se-Jick;Lee, Joon-Seok
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권4호
    • /
    • pp.262-272
    • /
    • 2022
  • PURPOSE. This study aimed to analyze the shear bond strength between the 3D-printed denture base and the chairside relining material, according to the surface treatment. MATERIALS AND METHODS. Cylindrical specimens were prepared using DENTCA Denture Base II. The experimental groups were divided into 6 (n = 10): no surface treatment (C), Tokuyama Rebase II Normal adhesive (A), sandblasting (P), sandblasting and adhesive (PA), sandblasting and silane (PS), and the Rocatec system (PPS). After bonding the chairside relining material to the center of the specimens in a cylindrical shape, they were stored in distilled water for 24 hours. Shear bond strength was measured using a universal testing machine, and failure mode was analyzed with a scanning electron microscope. Shear bond strength values were analyzed using one-way analysis of variance, and Tukey's honest significant difference test was used for post-hoc analysis (P < .05). RESULTS. Group PPS exhibited significantly higher shear bond strength than all other groups. Groups P and PA displayed significantly higher bond strengths than the control group. There were no significant differences between groups PS and A compared to the control group. Regarding the failure mode, adhesive failure occurred primarily in groups C and A, and mixed failure mainly in groups P, PA, PS, and PPS. CONCLUSION. The shear bond strength between the 3D-printed denture base and the chairside relining material exhibited significant differences according to the surface treatment methods. It is believed that excellent adhesive strength will be obtained when the Rocatec system is applied to 3D-printed dentures in clinical practice.

Effect of the type of resin cement on the fracture resistance of chairside CAD-CAM materials after aging

  • Laura Vitoria Rizzatto;Daniel Meneghetti;Marielle Di Domenico;Julia Cadorin Facenda;Katia Raquel Weber;Pedro Henrique Corazza;Marcia Borba
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권3호
    • /
    • pp.136-144
    • /
    • 2023
  • PURPOSE. The study objective was to evaluate the influence of the type of resin cement on the flexural strength and load to fracture of two chairside CADCAM materials after aging. MATERIALS AND METHODS. A polymer-infiltrated ceramic network (PICN) and a nanoceramic resin (RNC) were used to produce the specimens. Two types of dual-cure resin cements, a self-adhesive and a universal, were investigated. Bilayer specimens were produced (n = 10) and aged for 6 months in a humid environment before the biaxial flexural strength test (σf). Bonded specimens were subjected to a mechanical aging protocol (50 N, 2 Hz, 37℃ water, 500,000 cycles) before the compressive load test (Lf). σf and Lf data were analyzed using two-way ANOVA and Tukey tests (α = .05). Chi-square test was used to analyze the relationship between failure mode and experimental group (α = .05). RESULTS. The type of resin cement and the interaction between factors had no effect on the σf and Lf of the specimens, while the type of restorative material was significant. RNC had higher σf and Lf than PICN. There was a significant association among the type of cracks identified for specimens tested in Lf and the restorative material. CONCLUSION. The type of resin cement had no effect on the flexural strength and load to fracture of the two investigated CAD-CAM chairside materials after aging.