• Title/Summary/Keyword: Cervical fusion

Search Result 168, Processing Time 0.026 seconds

Mitofusin-2 enhances cervical cancer progression through Wnt/β-catenin signaling

  • Sung Yong Ahn
    • BMB Reports
    • /
    • v.57 no.4
    • /
    • pp.194-199
    • /
    • 2024
  • Overexpression of mitofusin-2 (MFN2), a mitochondrial fusion protein, is frequently associated with poor prognosis in cervical cancer patients. Here, I aimed to investigate the involvement of MFN2 in cervical cancer progression and determine the effect of MFN2 on prognosis in cervical cancer patients. After generating MFN2-knockdown SiHa cells derived from squamous cell carcinoma, I investigated the effect of MFN2 on SiHa cell proliferation using the Cell Counting Kit-8 assay and determined the mRNA levels of proliferation markers. Colony-forming ability and tumorigenesis were evaluated using a colony-formation assay and tumor xenograft mouse models. The migratory and invasive abilities associated with MFN2 were measured using wound-healing and invasion assays. Wnt/β-catenin-mediated epithelial-mesenchymal transition (EMT) markers related to MFN2 were assessed through quantitative RT-PCR. MFN2-knockdown SiHa cells exhibited reduced proliferation, colony formation, migration, invasion, and tumor formation in vivo. The motility of SiHa cells with MFN2 knockdown was reduced through Wnt/β-catenin-mediated EMT inhibition. MFN2 promoted cancer progression and tumorigenesis in SiHa cells. Overall, MFN2 could serve as a therapeutic target and a novel biomarker for cervical cancer.

Risk Factors of Allogenous Bone Graft Collapse in Two-Level Anterior Cervical Discectomy and Fusion

  • Woo, Joon-Bum;Son, Dong-Wuk;Lee, Su-Hun;Lee, Jun-Seok;Lee, Sang Weon;Song, Geun Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.4
    • /
    • pp.450-457
    • /
    • 2019
  • Objective : Anterior cervical discectomy and fusion (ACDF) is commonly used surgical procedure for cervical degenerative disease. Among the various intervertebral spacers, the use of allografts is increasing due to its advantages such as no harvest site complications and low rate of subsidence. Although subsidence is a rare complication, graft collapse is often observed in the follow-up period. Graft collapse is defined as a significant graft height loss without subsidence, which can lead to clinical deterioration due to foraminal re-stenosis or segmental kyphosis. However, studies about the collapse of allografts are very limited. In this study, we evaluated risk factors associated with graft collapse. Methods : We retrospectively reviewed 33 patients who underwent two level ACDF with anterior plating using allogenous bone graft from January 2013 to June 2017. Various factors related to cervical sagittal alignment were measured preoperatively (PRE), postoperatively (POST), and last follow-up. The collapse was defined as the ratio of decrement from POST disc height to follow-up disc height. We also defined significant collapses as disc heights that were decreased by 30% or more after surgery. The intraoperative distraction was defined as the ratio of increment from PRE disc height to POST disc height. Results : The subsidence rate was 4.5% and graft collapse rate was 28.8%. The pseudarthrosis rate was 16.7% and there was no association between pseudarthrosis and graft collapse. Among the collapse-related risk factors, pre-operative segmental angle (p=0.047) and intra-operative distraction (p=0.003) were significantly related to allograft collapse. The cut-off value of intraoperative distraction ${\geq}37.3%$ was significantly associated with collapse (p=0.009; odds ratio, 4.622; 95% confidence interval, 1.470-14.531). The average time of events were as follows: collapse, $5.8{\pm}5.7months$; subsidence, $0.99{\pm}0.50months$; and instrument failure, $9.13{\pm}0.50months$. Conclusion : We experienced a higher frequency rate of collapse than subsidence in ACDF using an allograft. Of the various preoperative factors, intra-operative distraction was the most predictable factor of the allograft collapse. This was especially true when the intraoperative distraction was more than 37%, in which case the occurrence of graft collapse increased 4.6 times. We also found that instrument failure occurs only after the allograft collapse.

Clinical Outcome of Modified Cervical Lateral Mass Screw Fixation Technique

  • Kim, Seong-Hwan;Seo, Won-Deog;Kim, Ki-Hong;Yeo, Hyung-Tae;Choi, Gi-Hwan;Kim, Dae-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.2
    • /
    • pp.114-119
    • /
    • 2012
  • Objective : The purpose of this study was 1) to analyze clinically-executed cervical lateral mass screw fixation by the Kim's technique as suggested in the previous morphometric and cadaveric study and 2) to examine various complications and bicortical purchase that are important for b-one fusion. Methods : A retrospective study was done on the charts, operative records, radiographs, and clinical follow up of thirty-nine patients. One hundred and seventy-eight lateral mass screws were analyzed. The spinal nerve injury, violation of the facet joint, vertebral artery injury, and the bicortical purchases were examined at each lateral mass. Results : All thirty-nine patients received instrumentations with poly axial screws and rod systems, in which one hundred and seventy-eight screws in total. No vertebral artery injury or nerve root injury were observed. Sixteen facet joint violations were observed (9.0%). Bicortical purchases were achieved on one hundred and fifty-six (87.6%). Bone fusion was achieved in all patients. Conclusion : The advantages of the Kim's technique are that it is performed by using given anatomical structures and that the complication rate is as low as those of other known techniques. The Kim's technique can be performed easily and safely without fluoroscopic assistance for the treatment of many cervical diseases.

Expandable Cage for Cervical Spine Reconstruction

  • Zhang, Ho-Yeol;Thongtrangan, Issada;Le, Hoang;Park, Jon;Kim, Daniel H.
    • Journal of Korean Neurosurgical Society
    • /
    • v.38 no.6
    • /
    • pp.435-441
    • /
    • 2005
  • Objective : Expandable cage used for spinal reconstruction after corpectomy has several advantages over nonexpendable cages. Here we present our clinical experience with the use of this cage after anterior column corpectomy with an average of one year follow up. Methods : Ten patients underwent expandable cage reconstruction of the anterior column after single-level or multilevel corpectomy for various cervical spinal disorders. Anterior plating with or without additional posterior instrumentation were performed in all patients. Functional outcomes, complications, and radiographic outcomes were determined. Results : There was no cage-related complication. Functionally, neurological examination revealed improvement in 7 of 10 patients and no patient had neurological deterioration after the surgery. Immediate stability was achieved and maintained throughout the period of follow-up. There was minimal subsidence [<2mm] noticeable in three of the cases that underwent a two-level corpectomy. Subsidence was noted in osteoporotic patients and patients undergoing multi-level corpectomies. Average pre-operative kyphotic angle was 9 degrees. This was corrected to an average of 5.4 degrees in lordosis postoperatively. Conclusion : In conclusion, expandable cages are safe and effective devices for vertebral body replacement after cervical corpectomy when used in combination with anterior plating with or without additional posterior stabilization. The advantages of using expandable cages include its ability to easily accommodate itself into the corpectomy defect, its ability to tightly purchase into the end plates after expansion and thus minimizing the potential for migration, and finally, its ability to correct kyphosis deformity via its in vivo expansion properties.

Novel Hybrid Hydroxyapatite Spacers Ensure Sufficient Bone Bonding in Cervical Laminoplasty

  • Tanaka, Nobuhiro;Nakanishi, Kazuyoshi;Kamei, Naosuke;Nakamae, Toshio;Kotaka, Shinji;Fujimoto, Yoshinori;Ochi, Mitsuo;Adachi, Nobuo
    • Asian Spine Journal
    • /
    • v.12 no.6
    • /
    • pp.1078-1084
    • /
    • 2018
  • Study Design: Prospective observational study. Purpose: This prospective analysis aimed to evaluate the efficacy and bone-bonding rate of hybrid hydroxyapatite (HA) spacers in expansive laminoplasty. Overview of Literature: Various types of spacers or plates have been developed for expansive laminoplasty. Methods: Expansive open-door laminoplasty was performed in 146 patients with cervical myelopathy; 450 hybrid HA spacers and 41 autogenous bone spacers harvested from the spinous processes were grafted into the opened side of each lamina. The patients were followed up using computed tomography (CT), and their bone-bonding rates for hybrid HA and autogenous spacers, bone-fusion rates of the hinges of the laminae, and complications associated with the implants were then examined. Results: Clinical symptoms significantly improved in all patients, and no major complications related to the procedure were noted. The hybrid HA spacers exhibited sufficient bone bonding on postoperative CT. The hinges completely fused in over 95% patients within 1 year of the procedure. Only 4 spacers (0.9%) developed lamina sinking, and most expanded laminae maintained their positions without sinking or floating throughout the follow-up period. Conclusions: Hybrid HA spacers contributed to high bone-fusion rates of the spacers and hinges of the laminae, and no complications were associated with their use. Cervical laminoplasty with these spacers is safe and simple, and it yields sufficient fixation strength while ensuring sufficient bone bonding during the immediate postoperative period.

A Case Report of Neck Pain Patient with Klippel-Feil Syndrome by Cervical Manipulation Treatment (Klippel-Feil 증후군 환자의 경추 도수치료 후 발생한 부작용 치험1례)

  • Lee, Jong-Ha;Kwon, Jeong-Gook;Keum, Dong-Ho
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.25 no.2
    • /
    • pp.175-180
    • /
    • 2015
  • The Klippel-Feil Syndrome (KFS) is characterized by congenital fusion of two or more vertebrae with hypermobile normal segment. According to this, a patient with KFS can be at risk of severe neurological symptoms after manipulation treatment. We had a KFS patient who suffered from neck pain and limited range of motion at cervical after manipulation treatment. The patient, 49-year-old woman was diagnosed as KFS through Cervical X-ray and MRI. The patient was treated by acupuncture therapy and SCENAR therapy. We measured neck pain by visual analog scale (VAS) and neck disability index (NDI) and checked range of motion at cervical before and after the treatments. After 8 times treatments, the patient's pain decreased and the range of motion increased. From this case, we can recognize the risk of Chuna manipulation treatment for KFS patient. So, we suggest that radiological examination is needed before cervical Chuna manipulation treatment to avoid adverse reactions.

Bacterial Meningitis Complicated by Myelitis Following Anterior Cervical Spinal Surgery (전방 경추 수술 후 발생한 세균성 뇌수막염과 동반된 척수염)

  • Ham, Dong-Hun;Choi, Byeong-Yeol;Jung, Myung-Cheol
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.6
    • /
    • pp.519-524
    • /
    • 2021
  • Meningitis after spinal surgery occurs rarely but can be fatal. A 49-year-old male was diagnosed with compressive myelopathy due to cervical disc herniation at the C 5, 6 level and underwent anterior cervical discectomy and fusion (ACDF). He complained of severe neck pain and stiffness with fever postoperatively and one week after surgery, the patient presented with abrupt tetraplegia. The follow-up magnetic resonance imaging and cerebrospinal fluid analysis revealed bacterial meningitis complicated by myelitis. The patient was treated with antibiotics and steroid, but the outcome was poor. The authors report a case of meningitis combined with myelitis following anterior cervical spinal surgery.

Long-Term Follow-Up Results of Anterior Cervical Inter-Body Fusion with Stand-Alone Cages

  • Kim, Woong-Beom;Hyun, Seung-Jae;Choi, Hoyong;Kim, Ki-Jeong;Jahng, Tae-Ahn;Kim, Hyun-Jib
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.4
    • /
    • pp.385-391
    • /
    • 2016
  • Objective : The purpose of this study was to evaluate long-term follow-up radiologic/clinical outcomes of patients who underwent anterior cervical discectomy and inter-body fusion (ACDF) with stand-alone cages (SAC) in a single academic institution. Methods : Total 99 patients who underwent ACDF with SAC between February 2004 and December 2012 were evaluated retrospectively. A total of 131 segments were enrolled in this study. Basic demographic information, radiographic [segmental subsidence rate, fusion rate, C2-7 global angle, and segmental angle changes)/clinical outcomes (by Odom's criteria and visual analog score (VAS)] and complications were evaluated to determine the long-term outcomes. Results : The majority were males (55 vs. 44) with average age of 53.2. Mean follow-up period was 62.9 months. The segmental subsidence rate was 53.4% and fusion rate was 73.3%. In the subsidence group, anterior intervertebral height (AIH) had more tendency of subsiding than middle or posterior intervertebral height (p=0.01). The segmental angle led kyphotic change related to the subsidence of the AIH. Adjacent segmental disease was occurred in 18 (18.2%) patients. Total 6 (6%) reoperations were performed at the index level. There was no statistical significance between clinical and radiological outcomes. But, overall long-term clinical outcome by Odom's criteria was unsatisfactory (64.64%). The neck and arm VAS score were increased by over time. Conclusion : Long-term outcomes of ACDF with SAC group were acceptable but not satisfactory. For optimal decision making, more additional comparative long-term outcome data is needed between ACDF with SAC and ACDF with plating.

Significance of Preoperative Prone Position Computed Tomography in Free Hand Subaxial Cervical Pedicular Screwing

  • Istemen, Iismail;Arslan, Ali;Olgune, Semih Kivanc;Afser, Kemal Alper;Acik, Vedat;Arslan, Baris;Okten, Ali Ihsan;Gezercan, Yurdal
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.2
    • /
    • pp.247-254
    • /
    • 2021
  • Objective : The subaxial cervical pedicle screwing technique shows powerful biomechanical properties for posterior cervical fusion. When applying a pedicle screw using the freehand technique, it is essential to analyse cervical computed tomography and plan the surgery accordingly. Normal cervical computed tomography is usually performed in the supine position, whereas during surgery, the patient lies in a prone position. This fact leads us to suppose that radiological evaluations may yield misleading results. Our study aimed to investigate whether there is any superiority between preoperative preparation on computed tomography performed in the prone position and that performed in the supine position. Methods : This study included 17 patients (132 pedicle screws) who were recently operated on with cervical vertebral computed tomography in the prone position and 17 patients (136 pedicle screws) who were operated on by conventional cervical vertebral computed tomography as the control group. The patients in both groups were compared in terms of age, gender, pathological diagnosis, screw malposition and complications. A screw malposition evaluation was made according to the Gertzbein-Robbins scale. Results : No statistically significant difference was observed between the two groups regarding age, gender and pathological diagnosis. The screw malposition rate (from 11.1% to 6.9%, p<0.05), mean malposition distance (from 2.18 mm to 1.86 mm, p <0.05), and complications statistically significantly decreased in the prone position computed tomography group. Conclusion : Preoperative surgical planning by performing cervical vertebral computed tomography in the prone position reduces screw malposition and complications. Our surgical success increased with a simple modification that can be applied by all clinicians without creating additional radiation exposure or additional costs.

Preliminary Experience with Cervical Implantable Titanium Cage(RABEA) in Patients with Monosegmental Degenerative Disease : Clinical and Radiological Outcomes without Cancellous Bone Filling into Cage (단일 분절 퇴행성 경추질환에서 Titanium Cage를 이용한 전방 융합술의 조기 치험 : 골편 이식을 동반하지 않은 경우의 임상적 방사선학적 초기 결과)

  • Lee, Young-Kyun;Han, Young-Min;Kim, Jong-Tae;Chung, Dong-Sup;Park, Young-Sup;Park, Chun-Kun;Kang, Joon-Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup2
    • /
    • pp.300-308
    • /
    • 2001
  • Objectives : Anterior cervical discectomy and interbody fusion has become a well-accepted surgical treatment of degenerative cervical diseases. Implatable cages have a stabilizing effect without plates and no need for autogenous bone graft. The authors evaluates the effect of implatable titanium cage(RABEA) on the clinical and radiological outcomes. Methods : 34 patients with symptomatic cervical degenerative diseases due to one level disc pathology were underwent anterior cervical discectomy and interbody fusion with titanium cages(RABEA) which were not filled with cancallous bone grafts from January 1999 to May 2001. Patients with osteoporosis and older than 65 years were not included. Among them, 15 patients could be followed-up for at least 1 year. The authors retrospectively reviewed the charts and radiographic data. Mean follow-up period was $1.3{\pm}0.2years$. Results : Clinical results according to the Odom's criteria was exellent and good in 14(93%) patients. One patient with fair result showed complete loss of the disc space height due to settlement of the cage. Preoperatively, the mean height of the disc space(${\pm}$standard deviation) was $3.42{\pm}1.10mm$(range 2.0-5.5mm), and at 1 day postoperatively it was $7.88{\pm}0.90mm$(range 6.50-9.0). The mean height of the disc space after 1 year was $6.50{\pm}1.38mm$(range 3.0-8.0). The restoration of the height was statistically significant(p<0.05). The mean height after 1 year was $82.7{\pm}15.9%$ of the height at 1 day postoperatively. Preoperatively the mean value of the cervical lodortic angle was $21.8{\pm}11.8^{\circ}$ and 1 year postopertively, it was $24.5{\pm}8.3^{\circ}$, which was statistically not significant. All patients showed no abnormal movements on flexion and extension lateral film after 6 months. Conclusion : Implantable titanium cages appear safe and effective in selected patients, and their use helps to avoid complications associated with bone graft harvest. Subsidence of the cage seems to be a potential risk factor for recurrence of the symptoms. For long-term results, a longer follow-up is required.

  • PDF