• Title/Summary/Keyword: Certified reference material (CRM)

Search Result 59, Processing Time 0.028 seconds

Determination of trace elements in food reference materials by instrumental neutron activation analysis

  • Cho, K.H.;Zeisler, R.;Park, K.W.
    • Analytical Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.520-528
    • /
    • 2005
  • Two biological Certified Reference Materials (CRMs), KRISS 108-04-001 (oyster tissue) and 108-05-001 (water dropwort stem), were prepared by Korea Research Institute of Standards and Science (KRISS)during FY '01. The certified values of these materials had been determined by Isotope Dilution Mass Spectrometry (IDMS) for six elements (Cd, Cr, Cu, Fe, Pb and Zn). Additional analytical works are now progressing to certify the concentrations of a number of the environmental and nutrimental elements in these CRMs. The certified values in a CRM are usually determined by using a single primary method with confirmation by other method(s) or using two independent critically-evaluated methods. Instrumental Neutron Activation Analysis (INAA) plays an important role in the determination of certified values as it can eliminate the possibility of common error sources resulting from sample dissolution. In this study INAA procedure was used in determination of 23 elements in these two biological CRMs to acquire the concentration information and the results were compared with KRISS certified values.

Evaluation of accuracy for measurement of Dioxins (PCDDs/PCDFs) by using certified reference material (CRM) (인증표준물질(Certified reference materials, CRM)을 이용한 이옥신류(PCDDs/PCDFs) 측정의 정확도 평가)

  • Youn, Yeu Young;Park, Deok Hie;Lim, Young Hee;Cho, Hye Sung
    • Analytical Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.376-385
    • /
    • 2009
  • In our study, the accuracy for measurement of seventeen 2,3,7,8-substituted PCDDs/PCDFs in certified reference material (CRM) which is the sample of homogeneous sediment matrix taken from an area known to have significant chemical contamination, particularly PCBs (polychlorinated biphenyls), was evaluated. Though the methodology in this study followed the official method of unintentionally produced persistent organic pollutants (UPOPs) announced by the Ministry of Environment of the Republic of Korea in 2007, there were slight changes using additional purification step by activated carbon column because the interferences of sample were not sufficiently removed when only multi-silica column and alumina column have been used for purification. The |En| number proposed by the Korea Research Institute of Standards and Science was used for a valuation basis of the accuracy. The |En| numbers of seventeen 2,3,7,8-substituted PCDDs/PCDFs have been indicated as 1 and below, they were decided "Pass" in this test, when DB-5MS column and SP-2331 column were used together. Because 1,2,3,7,8-PeCDD and #169-HxCB were not separated on DB-5MS column, the ions of 1,2,3,7,8-PeCDD were selected at M/M+2 instead of M+2/M+4 suggested by EPA 1613. It is possible to distinguish them in HRGC/HRMS analysis.

Accurate Measurement of Arsenic in Laver by Gravimetric Standard Addition Method Combined with High Resolution Inductively Coupled Plasma Mass Spectrometry

  • Lee, Kyoung-Seok;Kim, Hyeon-Ji;Yim, Yong-Hyeon;Kim, Jeongkwon;Hwang, Euijin
    • Mass Spectrometry Letters
    • /
    • v.5 no.2
    • /
    • pp.57-61
    • /
    • 2014
  • A gravimetric standard addition method combined with internal standard calibration has been successfully developed for the accurate analysis of total arsenic in a laver candidate reference material. A model equation for the gravimetric standard addition approach using an internal standard was derived to determine arsenic content in samples. Handlings of samples, As standard and internal standard were carried out gravimetrically to avoid larger uncertainty and variability involved in the volumetric preparation. Germanium was selected as the internal standard because of its close mass to the arsenic to minimize mass-dependent bias in mass spectrometer. The ion signal ratios of $^{75}As^+$ to $^{72}Ge^+$ (or $^{73}Ge^+$) were measured in high resolution mode ($R{\geq}10,000$) to separate potential isobaric interferences by high resolution ICP/MS. For method validation, the developed method was applied to the analysis of arsenic content in the NMIJ 7402-a codfish certified reference material (CRM) and the result was $37.07mg{\cdot}kg^{-1}{\pm}0.45mg{\cdot}kg^{-1}$ which is in good agreement with the certified value, $36.7mg{\cdot}kg^{-1}{\pm}1.8mg{\cdot}kg^{-1}$. Finally, the certified value of the total arsenic in the candidate laver CRM was determined to be $47.15mg{\cdot}kg^{-1}{\pm}1.32mg{\cdot}kg^{-1}$ (k = 2.8 for 95% confidence level) which is an excellent result for arsenic measurement with only 2.8 % of relative expanded uncertainty.

Development of Certified Reference Materials for Analysis of Heavy Metals in Paints to Cope with Environmental Regulations (환경규제 대응을 위한 페인트 중의 중금속 분석용 인증 표준물질 개발)

  • Yu, Byung Kyu;Sun, Yle Shik
    • Journal of Environmental Analysis, Health and Toxicology
    • /
    • v.21 no.4
    • /
    • pp.209-219
    • /
    • 2018
  • In the areas of RoHS, WEEE, ELV and REACH, reinforcement of environmental regulations against harmful substances is a global trend not only in EC but also in all over the world. In the fields of Korea's major export products such as material parts, electrical and electronic products and automobile parts, we are responding to these regulations consistently. To develop reference material for analyzing lead and cadmium in paints, the candidate materials were produced through the screening process which separated shapes and sizes. To secure the traceability of the candidate materials produced, the characteristics and uncertainties are estimated by ICP-AES analysis using the primary reference material. The short-term and long-term stabilities also are evaluated in parallel. In order to calculate the final certification value of the candidate material, the verification were carried out by the performance evaluation through the comparison among the KOLAS (Korea Laboratory Accreditation Scheme) laboratories, and the CRM was produced in accordance with ISO Guide 35. The certified values and uncertainties of Pb and Cd of the final paint standard, determined according to the joint analysis among laboratories, are Pb [($191.4{\pm}3.1$) mg/kg, ($944.1{\pm}5.6$) mg/kg] and Cd [($45.0{\pm}2.6$) mg/kg, ($225.5{\pm}3.5$) mg/kg]. These standard materials were developed to enhance the reliability of measurement analysis, including the validity and traceability of measurement results. Also it is expected that the CRM will be used as QCM (quality control material) for the product design and the process monitoring, so that regulation and management of hazardous heavy metals can be systematically implemented.

Development of certified reference material (CRM)s for surface analysis II : multilayer thin films for sputter depth profiling (표면분석용 인증표준물질의 개발 II : 깊이분포도용 다층 박막 표준물질의 개발)

  • 김경중;문대원
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.3B
    • /
    • pp.283-289
    • /
    • 1999
  • Multilayer thin film reference materials for the sputter depth profiling analysis are used to calibrate the sputter depth scale by measuring the sputtering rate and to optimize the sputtering conditions for the best depth resolution. Surface analysis group of Korea Research Institute of Standards and science (KRISS) have developed various types of multilayer thin films by using an ion beam sputter deposition and in-situ surface analysis system. The chemical states of the thin films reference materials were certified by in-situ XPS and the thicknesses were certified by transmission electron microscopy (TEM).

  • PDF

Design and Fabrication of a Step Height Certified Reference Material for Multi-probe Inspection Instruments (다중 프로브 검사 계측 장비를 위한 단차 표준 인증 물질의 설계 및 제작)

  • Maeng, Sae-Rom;Jin, Jong-Han;Buajarern, Jariya;Kim, Jae-Wan;Kim, Jong-Ahn;Kang, Chu-Shik
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.3
    • /
    • pp.323-329
    • /
    • 2011
  • Certified reference materials (CRMs) have been used to calibrate surface profilers for reliable measurements. In this paper, we present a newly designed step height CRM which has a step height pattern with two different widths and various special patterns for checking radial magnification, distortion of optical viewing systems, etc. Especially, it could be useful for multi-probe inspection instruments in the manufacturing lines. The fabrication was done by conventional optical lithography and dry etching process with optimized conditions. To verify the step height values, a white-light scanning interferometer was used with objective lenses having magnification of $10{\times}$ and $100{\times}$. CRMs with nominal step heights of $0.5\;{\mu}m$, $1\;{\mu}m$, $3\;{\mu}m$, $5\;{\mu}m$, $7\;{\mu}m$, and $10\;{\mu}m$ were fabricated and the uniformity of these CRMs was evaluated to be less than 3 nm ($1{\sigma}$).

Analysis of heavy metal in polymer materials by combustion ICP-AES Method (연소법 전처리에 의한 고분자 물질 중 중금속의 분석)

  • Lim, Heon-Sung;Lee, Bo-Reum;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.615-618
    • /
    • 2010
  • An oxygen bomb combustion procedure were studied for determination of heavy metal in polymer materials such as polyvinyl chloride and polypropylene by ICP-AES. This method is proposed as a rapid and simple sample preparation for decomposition of polymer containing certified contents of the analytes by teflon coated oxygen bomb combustion using different absorbing solution. The recoveries of metal were found to be 30~102% from absorbed solution by ICP-AES method using polypropylene certified reference material(PP CRM-As, Ba, Cd, Hg, Pb, Zn). The recoveries of metal using PVC CRM(Cd, Hg, Pb) was found to be 45 ~101% with same procedures.

RRT Study for the Quantitative Analysis of Boron in Silicon (실리콘에 도핑된 붕소의 정량분석에 대한 공동분석연구)

  • 김경중;김현경;문대원;홍태은;정칠성;김이경;김재남;임철호;김정호
    • Journal of the Korean Vacuum Society
    • /
    • v.11 no.4
    • /
    • pp.218-224
    • /
    • 2002
  • A domestic round robin test(RRT) for the quantitative analysis of minor impurities was performed by a standard procedure and standard reference material. The certified reference material(CRM)s for B-doped Si thin film and analysis specimens and the analysis specimens were prepared by an ion beam sputter deposition method. These samples were certified by inductively coupled plasma mass spectrometry(ICP-MS) with isotope dilution method which il one of the most quantitative methods in chemical analysis. By using an international standard procedure(ISO/DIS-l4237) for the quantitative analysis of B in Si by SIMS, a domestic RRT was performed for these specimens. Although only a few laboratories participated in this RRT, the average B concentration well agreed with the certified value within 2% error.

A Rapid Method for Analysing Polycyclic Aromatic Hydrocarbons (PAH's) in Urban Dust Using Supercritical Fluid Extraction (SFE) and Gas Chromatography/Mass Spectrometry (GC/MS)허귀석, 김달호 (초임계유체추출과 GC/MS를 이용한 도심 대기분진 중 PAH들의 신속한 분석법에 관한 연구)

  • Heo, Gwi Seok;Kim, Dal Ho
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.10
    • /
    • pp.726-733
    • /
    • 1994
  • Supercritical fluid extraction (SFE) followed by gas chromatographic separation and mass spectrometric (MS) detection were used in rapid analysis of polycyclic aromatic hydrocarbons (PAH's) in air particulate material extracted for 30 min with 10 ml of supercritical $N_2O$ without another sample preparation step. Two samples, urban dust in Seoul area and a certified air particulate reference material 1649 supplied by the NBS (National Bureau of Standards), were processed for the purpose of evaluating extraction and analysis methods. As a result, the quantitative recovery of PAH's in the SFE method was relatively lower than conventional organic solvent extraction methods, but reproducibility was resonable, and analysis time was reduced remarkably. The method has proved to be suitable for monitoring of PAH's in air particulate material.

  • PDF