• 제목/요약/키워드: Ceramic on ceramic bearing

검색결과 52건 처리시간 0.027초

세라믹 볼베어링의 특성해석에 관한 연구 (A Study on the Characteristics of Ceramic Ball Bearing)

  • 김완두;한동철
    • Tribology and Lubricants
    • /
    • 제8권2호
    • /
    • pp.64-72
    • /
    • 1992
  • The recent trends of rotating machinery demand high speed and high temperature operation, and the bearing with new material is required to be developed. Ceramic, especially silicon nitride, have been receiving attention as alternative material to conventional bearing steel. Ceramic ball bearing offers major performance advantages over steel bearing, for instance, high speed, maginal lubrication, high temperature, improved corrosion resistance and nonmagnetic capabilities etc.. In this paper, the mechanical characteristics of ceramic ball bearing (hybrid ceramic bearing and all ceramic bearing) were investigated, and the characteristics of ceramic bearing were compared with that of steel bearing. Deep groove ball bearing 6208 was taken the object of analysis. The main results of analysis were followings: the radial stiffness of hybrid and all ceramic bearing were 112% and 130% that of steel bearing, and the axial stiffness of all ceramic bearing was 110% that of steel bearing. According as rotating speed was up, the ball load, the contact angle, the contact stress and the spin-to-roll ratio between ball and raceway of ceramic bearing were far smaller than these of steel bearing. And there was not a significant difference between the minimum film thickness of ceramic bearing and steel bearing. It is expected that this research is contributed to enhanced fundamental technology for the practical applications of ceramic ball bearing.

1" HDD용 세라믹 공기 동압 베어링 개발 (Development of Self Acting Air-Lubricated Ceramic Bearing for 1" HDD)

  • 유진규;황태연
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.567-570
    • /
    • 2003
  • In recent years, the demand of mobile device, such as digital camera, camcorder and PDA, increases remarkably. So, requirements of the mobile information data storage used in the mobile devices increase noticeably also. 1" micro data storage is a kind of mobile storage. which has a CF type II form factor, and the similar structure of the general 3.5" HDD. In this paper, we developed the self acting air-lubricated ceramic bearing for the 1" micro data storage. The self acting air-lubricated ceramic bearing Is superior to the fluid bearing and the ball bearing on power consumption.

  • PDF

교량받침용 세라믹 마찰재 적용을 위한 실험적 연구 (Experimental Study on the Application of Ceramic Friction Materials for Bridge Bearing)

  • 박지훈;이정우;곽종원
    • 한국건설순환자원학회논문집
    • /
    • 제11권4호
    • /
    • pp.527-534
    • /
    • 2023
  • 본 논문은 기존의 교량받침 마찰재인 PTFE의 내구성을 보완하고 낮은 마찰계수 발현 및 윤활제 미사용에서 마찰거동을 할 수 있는 세라믹 소재의 교량받침 적용을 위한 연구를 수행하였다. 세라믹 소재는 지르코니아계(ZrO2)를 설정하였으며, 조도계수에 따른 마찰거동 평가를 수행하였다. 조도계수는 0.8 및 0.027로 구분하였으며, 15 MPa 면압조건에서 평균마찰계수는 모두 0.16으로 산정되었다. 이후, 세라믹을 마찰재로 제작하여 교량받침에 적용하였으며, PTFE 적용 교량받침과의 압축실험 및 마찰실험을 통해 성능비교를 수행하였다. 압축실험에서 세라믹 및 PTFE 적용 교량받침은 하중 재하에 따라 이상적인 압축거동을 나타냈다. 세라믹 적용 교량받침은 파손 및 결함이 관찰되지 않았지만, PTFE 적용 교량받침에서는 윤활제 소실이 관찰되었다. 마찰거동을 통해 분석한 세라믹 적용 교량받침의 평균마찰계수는 0.16으로 나타났다. 세라믹의 물리적 및 화학적 특성의 고유 재료물성과 성능평가를 통해 도출된 우수한 역학적 특성 및 0.16 수준의 마찰계수는 마찰재로써 고려할 수 있는 가능성을 제시한다.

Pseudotumor and Subsequent Implant Loosening as a Complication of Revision Total Hip Arthroplasty with Ceramic-on-Metal Bearing: A Case Report

  • Naik, Lokesh Gudda;Shon, Won Yong;Clarke, I.C.;Moon, Jun-Gyu;Mukund, Piyush;Kim, Sang-Min
    • Hip & pelvis
    • /
    • 제30권4호
    • /
    • pp.276-281
    • /
    • 2018
  • Pseudotumors are not uncommon complications after total hip arthroplasty (THA) and may occur due to differences in bearing surfaces of the head and the liner ranging from soft to hard articulation. The most common causes of pseudotumors are foreign-body reaction, hypersensitivity and wear debris. The spectrum of pseudotumor presentation following THA varies greatly-from completely asymptomatic to clear implant failure. We report a case of pseudo-tumor formation with acetabular cup aseptic loosening after revision ceramic-on-metal hip arthroplasty. The patient described herein underwent pseudotumor excision and re-revision complex arthroplasty using a trabecular metal shell and buttress with ceramic-on-polyethylene THA. Surgeons should be aware of the possibility of a pseudotumor when dealing with revisions to help prevent rapid progression of cup loosening and implant failure, and should intervene early to avoid complex arthroplasty procedures.

The Wear Rate and Survivorship in Total Hip Arthroplasty Using a Third-generation Ceramic Head on a Conventional Polyethylene Liner: A Minimum of 15-year Follow-up

  • Bum-Jin Shim;Sung-Jin Park;Chan Ho Park
    • Hip & pelvis
    • /
    • 제34권2호
    • /
    • pp.115-121
    • /
    • 2022
  • Purpose: The purpose of this study was to evaluate the wear and survival rates of third-generation ceramic heads on a conventional ultra-high molecular weight polyethylene liner. Materials and Methods: A total of 160 hips (147 patients with a mean age of 55.9 years) who underwent total hip arthroplasty using the third-generation ceramic head on a conventional polyethylene liner from March 1998 to August 2003 were reviewed retrospectively. Evaluation of the wear rate for 56 hips (49 patients) followed-up for at least 15 years was performed using the PolyWare program version 8 (Draftware Developers, USA). The Kaplan-Meier survivorship was also evaluated. Results: Linear wear and volumetric wear rates were 0.11±0.47 mm/year and 32.75±24.50 mm3/year, respectively. Nine revisions were performed during the follow-up period because of cup or stem loosening. The Kaplan-Meier survival rate, using cup revision or total revision total hip arthroplasty (THA) as the endpoint of analysis, was 93.7% at 15 years and 73.6% at 20 years. Conclusion: Because all revisions were performed between 15 and 20 years in our study, surgeons should pay greater attention to patients who underwent THA with ceramic-on-polyethylene bearing from 15 years postoperatively. Contemporary alumina ceramic on highly cross-linked polyethylene could certainly be a good alternative bearing couple providing better longevity.

국내 점토광물의 특성연구 (Characteristics of Domestic Clay Minerals)

  • 임응극;박순자;정수진;김환
    • 한국세라믹학회지
    • /
    • 제17권1호
    • /
    • pp.13-19
    • /
    • 1980
  • Mineral identifications on halloysite in Hadong-Sancheong area and the halloysite bearing clay ii Yeoju, Yesan and Hampyeong-Muan area are carried out by the method of X-ray diffraction, electron microscopy and DTA. Chemical composition of the above minerals are analyzed by means of X-ray-fluorescence. Refractoriness are also measured by refractoriness tester. A standard diagram for quantitative analysis of halloysite is given.

  • PDF

고속 앵귤러 컨택트 볼 베어링의 온도특성 (Temperature Characteristics of High Speed Angular Contact Ball Bearing)

  • 현준수;박태조
    • 한국정밀공학회지
    • /
    • 제18권2호
    • /
    • pp.96-101
    • /
    • 2001
  • This paper shows the temperature characteristics of a high speed angular contact ball gearing which is 7004C type with ISO P2 tolerance class. A built-in motor type high speed spindle which adopts an oil-air lubrication system was used to measure the temperature rise up to 60,000rpm. The gearing temperature was measured using thermocouples that were attached to the outside surfaces of the outer rings. The result showed that the continuous test method which was suggested in this paper is more effective than on and off method and the lubrication oil supply rate should be reduced in high speed rolling bearings as long as the seizure does not occur. And the result were confirmed that the bearings packed with ceramic balls are superior to those with steel balls in temperature characteristics.

  • PDF

Electro-osmosis에 의한 Dehydration (Dehydration by Electro-osmosis on Ceramic Body)

  • 한상목
    • 산업기술연구
    • /
    • 제4권
    • /
    • pp.43-46
    • /
    • 1984
  • In process of water removing safely from plastic clay, an electric field applied to a wet, porous solid such as day usually causes the rapid dehydration. The water-bearing positive ions move to negative electrode under the d. c. electrical stress or field. Therefore application of electro-osmosis to wet clay could include drying thick and large-scale ceramic body quickly and evenly. The d. c. power supply unit to 60 volts is necessary for safe practice. Also wider contact area and shorter distance between electrodes accelerate effectively the removal of water.

  • PDF

오일제트윤활방식의 25,000rpm급 모터내장형 고속주축계의 윤활특성에 관한 연구

  • 이용희;김태형;박보선
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.841-845
    • /
    • 1995
  • In this study, a motor-integrated high-speed spindle system with .psi. 65mm*25,000rpm is developed by introducing the oil-jet lubrication method,ceramic angular contact ball bearing, a built-in motor and so on. And oil-jet lubrication experiments for evaluating the system performance are performed under various operation conditions. Especially, in order to establish the oil-jet lubrication conditions related to the development of a high-speed spindle system, the effects of oil supply rate and rotational spindle speed are investigated on the temperature rise, temperature distribution,motor current and so on.

  • PDF