• Title/Summary/Keyword: Ceramic bracket

Search Result 48, Processing Time 0.02 seconds

The comparison of the frictional force by the type and angle of orthodontic bracket and the coated or non-coated feature of archwire (교정용 브라켓의 종류와 각도, 호선의 코팅 여부에 따른 마찰력의 비교)

  • Jang, Tae-Ho;Kim, Sang-Cheol;Cho, Jin-Hyoung;Chae, Jong-Moon;Chang, Na-Young;Kang, Kyung-Hwa
    • The korean journal of orthodontics
    • /
    • v.41 no.6
    • /
    • pp.399-410
    • /
    • 2011
  • Objective: The purpose of this study was to evaluate the difference in frictional resistance among metal, ceramic, self-ligation brackets and coated or non-coated Ni-Ti archwires at various bracket-archwire angulations during the sliding movement of an orthodontic archwire, using an orthodontic sliding simulation device. Methods: Four types of bracket (Micro-arch Perpect Clear2 Clippy-C and Damon3 and 5 types of orthodontic archwire (0.014", 0.016", and 0.016" ${\times}$ 0.022" inch coated Ni-Ti, and 0.016" and 0.016" ${\times}$ 0.022" inch Ni-Ti) were used. Further, the bracket- archwire angles were set at 4 different angulations: $0^{\circ}$, $3^{\circ}$, $6^{\circ}$, and $9^{\circ}$. Results: The frictions from all the experimental groups were found to be significantly increased in order of self-ligation brackets, Micro-arch and Perpect Clear2 ($p$ < 0.001). The presence of a coat had no effect on the friction of the same sized archwires at $0^{\circ}$ and $3^{\circ}$ bracket-archwire angles ($p$ < 0.001). Coated archwires had significantly higher frictions than the same sized non-coated archwires at $6^{\circ}$ and $9^{\circ}$ bracket-archwire angles ($p$ < 0.001). The frictions increased significantly as the bracket-archwire angles were increased ($p$ < 0.001). Conclusions: The use of self-ligation brackets will be beneficial in clinical situations where a low frictional force is required. Further, in cases where crowding is not severe, the use of coated archwires should not cause problems. However, more additional explanation is required considering the fact that the damage of coated archwire and exposure of the metal portion in case of binding and notching and the effects of saliva were not taken into account.

A Case Study of Degradation Characteristics for Rod-Insulator on Catenary System in Electric Railway (전기철도 전차선로 지지애자의 염해지역 열화특성 사례 연구)

  • Jung, Hosung;Park, Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.4
    • /
    • pp.263-266
    • /
    • 2019
  • In the Airport Railroad, the Yeongjong Bridge has a length of 4,420 m and connects Yeongjong Island with the mainland of Incheon City. The bridge is a two-level structure, consisting of a six-lane road at the upper level and a combination of a road and railroad at the lower level. The environmental conditions for the electric railway come mainly from the salt injury area and a heavy industry zone, and the maintenance cycles are determined differently depending on these conditions. This study analyzed the deterioration characteristics of long rod insulators produced with a movable ceramic bracket and polymer materials in the Yeongjong Bridge section of the Airport Railway operating in the salt injury area according to the material characteristics. Comparison of the corona measurements when the insulators were cleaned at the same time showed that the polymer insulator had a higher insulation performance than the ceramic insulator.

The effect of using laser for ceramic bracket bonding of porcelain surfaces (세라믹 브라켓 부착 시 레이저를 이용한 포세린 표면처리 효과)

  • An, Kyung-Mi;Sohn, Dong-Seok
    • The korean journal of orthodontics
    • /
    • v.38 no.4
    • /
    • pp.275-282
    • /
    • 2008
  • Objective: The purpose of this study was to investigate the effect of using laser for ceramic bracket bonding of porcelain surfaces and to compare it with conventional treatment of porcelain surfaces. Methods: Ninety feldspathic porcelain specimens were divided into 9 groups of 10, with each group having different surface treatments performed. Surface treatment groups were orthophosphoric acid, orthophosphoric acid with silane, hydrofluoric acid, hydrofluoric acid with silane, sandblasted, sandblasted with silane, laser etched, laser etched with silane, and glazed surface served as a control group. In the laser etched groups, the specimens were irradiated with 2-watt superpulse carbon dioxide ($CO_2$) laser for 20 seconds. Ceramic brackets were bonded with light-cure composite resin and all specimens were stored in water at $37^{\circ}C$ for 24 hours. Shear bond strength was determined in megapascals (MPa) by shear test at 1 mm/minute crosshead speed and the failure pattern was assessed. For statistical analysis, one-way ANOVA and tukey test were used. Results: Statistical analysis showed significant differences between the groups. The HFA + S group showed the highest mean shear bond strength ($13.92{\pm}1.94\;MPa$). This was followed by SB + S ($10.16\;{\pm}\;1.27\;MPa$), HFA ($10.09\;{\pm}\;1.07\;MPa$), L + S ($8.25\;{\pm}\;1.24\;MPa$), L ($7.86\;{\pm}\;0.96\;MPa$), OFA + S ($7.22\;{\pm}\;1.09\;MPa$), SB ($3.41\;{\pm}\;0.37\;MPa$), OFA ($2.81\;{\pm}\;0.37\;MPa$), G ($2.46\;{\pm}\;1.36\;MPa$), Bond failure patterns of HFA and silane groups, except L + S, were cohesive modes in porcelain while adhesive failure was observed in the control group and the rest of the groups. Conclusions : A 2-watt superpulse $CO_2$ laser etching of porcelain surfaces can provide a satisfactory result for porcelain surface treatment for ceramic bracket bonding. Laser irradiation may be an alternative conditioning method for the treatment of porcelain surfaces.

Surface roughness analysis of ceramic bracket slots using atomic force microscope (원자현미경을 이용한 세라믹 브라켓 슬롯의 표면조도에 대한 연구)

  • Park, Ki-Ho;Yoon, Hyun-Joo;Kim, Su-Jung;Lee, Gi-Ja;Park, Hun-Kuk;Park, Young-Guk
    • The korean journal of orthodontics
    • /
    • v.40 no.5
    • /
    • pp.294-303
    • /
    • 2010
  • Objective: This study was designed to measure the surface roughness at the slot floor of various ceramic brackets. Methods: One kind of stainless steel bracket ($Succes^{(R)}$), two kinds of monocrystalline brackets (Inspire $Ice^{(R)}$, $Perfect^{(R)}$) and two kinds of polycrystalline brackets (Crystalline $V^{(R)}$, $Invu^{(R)}$) were examined. Atomic force microscopy (AFM) was used to measure the surface roughness of each bracket. Data acquisition and processing were performed using $SPIP^{TM}$. Results: The differences in values of Sa, Sq, and Sz in $Invu^{(R)}$ and Inspire $Ice^{(R)}$ were not statistically different from the control group $Succes^{(R)}$. The values of Sa, Sq, and Sz of $Perfect^{(R)}$ and Crystalline $V^{(R)}$ were greater than those of $Succes^{(R)}$. Differences of all the Sa, Sq, and Sz values between $Perfect^{(R)}$ and Crystalline $V^{(R)}$ were not statistically significant. Conclusions: It is concluded that the slot surfaces of $Succes^{(R)}$, Inspire $Ice^{(R)}$, and $Invu^{(R)}$ were smooth compared to those of Crystalline $V^{(R)}$ and $Perfect^{(R)}$.

Shear bond strength and debonding failure mode of ceramic brackets according to the surface treatment of porcelain (도재 표면 처리가 따른 세라믹 브라켓의 전단 접착 강도 및 탈락 양상)

  • Lee, Jeong-Nam;Lee, Cheol-Won
    • The korean journal of orthodontics
    • /
    • v.28 no.5 s.70
    • /
    • pp.803-812
    • /
    • 1998
  • The purpose of this study was to evaluate the shear bond strength and failure mode of ceramic brackets according to the surface treatment of porcelain. Sixty Porcelain samples were randomly divided into six groups of ten samples. Then they were treated as follows: Group 1(silane only), Group 2(etching+silane), Group 3(stone+silane), Group 4(sandblasting+silane), Group 5(stone +etching+silane), Group 6(sandblasting+etching+silane) After surface treatment of porcelain, sixty Transcend 6000 brackets were bonded to the prepared porcelain surface and they were stored in $37^{\circ}C$ saline for 24 hours. An Instron universal testing machine was used to test the shear bond strength of ceramic brackets to porcelain. After debonding, bases of ceramic brackets and porcelain surfaces were examined under scanning electron microscope(SEM) to determine failure mode. Statistical analysis of the data was carried out with one-way ANOVA and Duncan's multiple range test. The results were as follows : 1. The shear bond strength of surface-treated groups 2 to 6 was higher than that of only silane-treated group 1, and there was statistical significance. (P<0.05) 2. There was no significant difference among the groups 3 to 6. (P>0.05) 3. The shear bond strength of etching-surface treated group 2 was significantly lower than those of sandblasting-surface treated group 4, complex surface treated group 5 and group 6. 4. According to the scanning electromicroscopic images, the surface roughness of sandblasting-surface treated group 4 was less than those of the group 5 and 6, but there was no significant difference in the shear bond strength. (P>0.05) As a conclusion we can have a clinically adequate bond strength when an application of silane is done after the treatment of porcelain surface with more than one way to bond ceramic bracket on the porcelain. Also, it is considered that the sandblasting and application of silane is effective for the simplication and convenience of the treatment.

  • PDF

Effect of thermocycling on shear bond strength and mode of failure of ceramic orthodontic brackets bonded to different porcelain restorations (수 종의 도재 수복물에 부착된 세라믹 브라켓의 전단접착강도와 파절양상에 열순환이 미치는 영향)

  • Kang, Sang-Wook;Son, Woo-Sung;Park, Soo-Byung;Kim, Seong-Sik
    • The korean journal of orthodontics
    • /
    • v.39 no.4
    • /
    • pp.225-233
    • /
    • 2009
  • Objective: The purpose of this study was to investigate the effect of thermocycling and type of porcelain restoration on shear bond strength (SBS) and mode of failure of monocrystalline ceramic brackets. Methods: A total of 60 porcelain discs were made and divided into three equal groups as follows: Ceramco 3, IPS Empress II, Zi-ceram/Vintage ZR. ceramic brackets were bonded to the prepared porcelain surfaces in the same manner. Each group was divided randomly into two subgroups: thermocycled group and non-thermocycled group (control). All samples were tested in shear mode on an universal testing machine. Results: SBS of the non-thermocycled group was clinically acceptable (Ceramco 3: $7.06\;{\pm}\;1.76\;MPa$, IPS Empress II: $7.55\;{\pm}\;2.38\;MPa$, Zi-ceram/Vintage ZR: $7.19\;{\pm}\;1.38\;MPa$). But, SBS of the thermocycled group was significantly reduced (Ceramco 3: $4.88\;{\pm}\;1.00\;MPa$, IPS Empress II: $5.46\;{\pm}\;1.35\;MPa$, Zi-ceram/Vintage ZR: $4.84\;{\pm}\;1.01\;MPa$, p < 0.05). There was no difference between the shear bond strength by type of porcelain restoration. All bonding failure occurred between bracket base and adhesive, except for 2 samples. Conclusions: The results of this study suggest that the type of porcelain restoration did not affect SBS, but thermocycling weakened SBS. Therefore, the effect of thermocycling should be considered when using ceramic brackets in practice.

Effect of orthodontic bonding with different surface treatments on color stability and translucency of full cubic stabilized zirconia after coffee thermocycling

  • Yasamin Babaee Hemmati;Hamid Neshandar Asli;Alireza Mahmoudi Nahavandi;Nika Safari;Mehran Falahchai
    • The korean journal of orthodontics
    • /
    • v.53 no.3
    • /
    • pp.139-149
    • /
    • 2023
  • Objective: To assess the color stability and translucency of full cubic stabilized zirconia (FSZ) following orthodontic bonding with different surface treatments and coffee thermocycling (CTC). Methods: This in vitro study was conducted on 120 disc-shaped specimens of FSZ. Thirty specimens were selected as the control group and remained intact. The remaining specimens were randomly divided into three groups based on the type of surface treatment (n = 30): airborne particle abrasion (APA), silica-coating (CoJet), and carbon dioxide (CO2) laser. After metal bracket bonding in the test groups, debonding and polishing were performed. Subsequently, all specimens underwent CTC (10,000 cycles). Color parameters, color difference (ΔE00), and translucency parameter (TP) were measured three times at baseline (t0), after debonding and polishing (t1), and after CTC (t2). Data were statistically analyzed (α = 0.05). Results: Significant difference existed among the groups regarding ΔE00t0t2 (p < 0.001). The APA group showed minimum (ΔE00 = 1.15 ± 0.53) and the control group showed maximum (ΔE00 = 0.19 ± 0.02) color stability, with no significant difference between the laser and CoJet groups (p = 0.511). The four groups were significantly different regarding ΔTPt0t2 (p < 0.001). Maximal increases in TP were noted in the CoJet (1.00 ± 0.18) and APA (1.04 ± 0.38) groups while minimal increase was recorded in the control group (0.1 ± 0.02). Conclusions: Orthodontic treatment makes zirconia restorations susceptible to discoloration and increased translucency. Nonetheless, the recorded ΔE00 and ΔTP did not exceed the acceptability threshold.

AN EXPERIMENTAL STUDY ON THE FATIGUE CHARACTERISTICS OF ORTHODONTIC BRACKETS BONDED TO ENAMEL (교정용 브라켓 접착부의 피로특성에 관한 실험적 연구)

  • Choi, Hae-Woon;Kim, Jeong-Gee
    • The korean journal of orthodontics
    • /
    • v.25 no.1 s.48
    • /
    • pp.55-72
    • /
    • 1995
  • The purpose of this study is to evaluate the effects of mechanical and thermal fatigue on the shear bond strength(SBS) in orthodontic brackets bonded to human premolars with chemically cured adhesive(Mono-$Lok^2$, Rocky Mountain Orthodontics). Two types of metal brackets (Ormesh, Microloc) and three types of ceramic brackets (Fascination, Starfire, Transcend 2000) were used in this study. The $10^6$ loadcycles of $|7.4{\times}10{^2}sin2{\pi}ft|g{\cdot}cm$ and the 1,000 thermocycles of 15 second dwell time each in $5^{\circ}C\;and\;55^{\circ}C$ baths were acturated as mechanical and thermal fatigue stress, and SBS were measured after each fatigue test. The fracture sites were examined by stereoscope and scanning electron microscope. The results obtained were summarized as follows, 1. In static shear bond test, Fascination brackets showed the maximum SBS($20.78\pm3.45$ MPa) and Microloc brackets showed the minimum SBS($14.88\pm3.10$ MPa). Fascination and Starfire brackets showed significantly greater SBS than Microloc brackets(P<0.05). 2. In mechanical fatigue test, Fascination brackets showed the maximum SBS ($20.19\pm3.45$ MPa) and Starfire brackets showed the minimum SBS($9.10\pm8.33$ MPa). The SBS or Transcend 2000 brackets(P<0.01) and Starfire brackets(P<0.05) significantly decreased after $10^6$ loadcycles. 3. In thermocycling test, Ormesh brackets showed the maximum SBS ($19.36\pm2.76$ MPa) and Starfire brackets showed the minimum SBS($11.94\pm6.86$ MPa). The SBS of Transcend 2000(P<0.01), Microloc and Starfire brackets(P<0.05) significantly decreased after $10^3$ thermocycles. 4. Failure sites of thermocycling groups were similar to those of static groups but after mechanical fatigue test, Ormesh and Transcend 2000 brackets failed at the bracket/resin interface and Microloc brackets failed within adhesive. Facination brackets failed at the enamel/resin interface irrespective of experimental condition.

  • PDF