• 제목/요약/키워드: Centrifuge model tests

검색결과 175건 처리시간 0.024초

환경진동의 지반내 전파특성과 차단에 관한 원심모형실험 (Centrifuge Simulation of Wave Propagation and Isolation Method)

  • 이강일;일하부치;김찬기;김태훈;실진성
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.738-745
    • /
    • 2004
  • There are a number of ways to reduce the ground vibrations, one of which is by installing underground walls. Model tests for ground vibration have been conducted in recent years, but limited attention has been paid to underground wall which can reduce high vibrations. Up to date, only barriers have been actually installed in dry sand because of many unknown factors subsisting on the behavior of the ground. The characteristics of vibration sources, ground conditions and wall barriers have not been well understood yet, therefore centrifugal modeling was adopted to examine all these characteristics. This paper describes a ball dropping system, which can generate a pulse wave propagation through soil mass, and the test results show the effectiveness of underground wall barrier in reducing mechanical vibration.

  • PDF

PRaFULL: A method for the analysis of piled raft foundation under lateral load

  • Stacul, Stefano;Squeglia, Nunziante;Russo, Gianpiero
    • Geomechanics and Engineering
    • /
    • 제20권5호
    • /
    • pp.433-445
    • /
    • 2020
  • A new code, called PRaFULL (Piled Raft Foundation Under Lateral Load), was developed for the analysis of laterally loaded Combined Pile Raft Foundation (CPRF). The proposed code considers the contribution offered by the raft-soil contact and the interactions between all the CPRF system components. The nonlinear behaviour of the reinforced concrete pile and the soil are accounted. As shallower soil layers are of great relevance in the lateral response of a pile foundation, PRaFULL includes the possibility to consider layered soil profiles with appropriate properties. The shadowing effect on the ultimate soil pressure is accounted, when dealing with pile groups, as proposed by the Strain Wedge Model. PRaFULL BEM code obviously requires less computational resources compared to FEM (Finite Element Method) or FDM (Finite Difference Method) codes. The proposed code was validated in the linear elastic range by comparisons with the code APRAF (Analysis of Piled Raft Foundations). The reliability of the procedure to predict piled raft performance was then verified in nonlinear range by comparisons with both centrifuge tests and computer code PRAB.

3D numerical investigation of segmental tunnels performance crossing a dip-slip fault

  • Zaheri, Milad;Ranjbarnia, Masoud;Dias, Daniel
    • Geomechanics and Engineering
    • /
    • 제23권4호
    • /
    • pp.351-364
    • /
    • 2020
  • This paper numerically investigates the effects of a dip-slip fault (a normal or a reverse fault) movement on a segmental tunnel which transversely crosses either of this kind of faults. After calibration of the numerical model with results from literature of centrifuge physical tests, a parametric study is conducted to evaluate the effects of various parameters such as the granular soil properties, the fault dip angle, the segments thickness, and their connections stiffnesses on the tunnel performance. The results are presented and discussed in terms of the ground surface and tunnel displacements along the longitudinal axis for each case of faulting. The gradient of displacements and deformations of the tunnel cross section are also analyzed. It is shown that when the fault dip angle becomes greater, the tunnel and ground surface displacements are smaller, in the case of reverse faulting. For this type of fault offset, increasing the tunnel buried depth causes tunnel displacements as well as ground surface settlements to enhance which should be considered in the design.

Mitigation of liquefaction-induced uplift of underground structures by soil replacement methods

  • Sudevan, Priya Beena;Boominathan, A.;Banerjee, Subhadeep
    • Geomechanics and Engineering
    • /
    • 제23권4호
    • /
    • pp.365-379
    • /
    • 2020
  • One of the leading causes for the damage of various underground structures during an earthquake is soil liquefaction, and among this liquefaction-induced uplift of these structures is a major concern. In this study, finite-difference modelling is carried out to study the liquefaction-induced uplift of an underground structure of 5 m diameter (D) with and without the replacement of the in-situ fine sand around the structure with the coarse sand. Soil replacements are carried out by three methods: replacement of soil above the structure, around the structure, and below the structure. The soil behaviour is represented using the elastic-perfectly plastic Mohr-Coulomb model, where the pore pressures were computed using Finn-Byrne formulation. The predicted pore pressure and uplift of the structure due to sinusoidal input motion were validated with the centrifuge tests reported in the literature. Based on numerical studies, an empirical equation is developed for the determination of liquefaction-induced maximum uplift of the underground structure without replacement of the in-situ sand. It is found that the replacement of soil around the structure with 2D width and spacing of D can reduce the maximum uplift by 50%.

실내시험을 이용한 저치환 보강지반의 평가 (Evaluation of the Low Replacement Reinforced Ground Using Laboratory Tests)

  • 배우석
    • 한국안전학회지
    • /
    • 제23권6호
    • /
    • pp.131-137
    • /
    • 2008
  • SCP(Sand Compaction Pile) method that forms a composite ground by driving compacted sand piles into the soft ground. This method is one of the soil improvement techniques for reinforcing and strengthening soft ground deposits. This thesis describes the investigation on the behavior of soft ground reinforced with SCP by low improvement ratio. Direct shear test and consolidation test carried out to verified behavior of composite ground reinforced with SCP. Test results were discussed with reference to the amount of consolidation settlement, variation of shear resistance with area replacement ratio and effect of the stress concentration. And, laboratory model loading test carried out to verified the effect of the location and failure mode of reinforced embankment. Residual shear strength varies with the area replacement and constrict load in the low replacement ratio. Calculated stress concentration ratio overestimate than proposed valve by experimental, theoretical and analytical method. As regards the location, improving right below of the top of the slope was more effective than below of the toe of the slope. This thesis carried out to obtain fundamental information of behavior of the composit ground. Hereafter, centrifuge test that reproduce stress state of the in-situ must be necessary through the further study about pile penetration, reinforce position and construct time.

Settlement behavior and controlling effectiveness of two types of rigid pile structure embankments in high-speed railways

  • Wang, Changdan;Zhou, Shunhua;Wang, Binglong;Guo, Peijun;Su, Hui
    • Geomechanics and Engineering
    • /
    • 제11권6호
    • /
    • pp.847-865
    • /
    • 2016
  • In this study, a series of geotechnical centrifugal tests were conducted to investigate the effectiveness of settlement control of two types of rigid pile structure embankments (PRSE) in collapsible loess under high-speed railway embankments. The research results show that ground reinforcement is required to reduce the post-construction settlement and settlement rate of the embankments. The rigid pile structure embankments using rigid piles can substantially reduce the embankment settlement in the construction of embankments on collapsible loess, and the efficiency in settlement reduction is affected by the pile spacing. The pile-raft structure embankments (PRSE) have much stronger ability in terms of the effectiveness of settlement control, while the pile-geogrid structure embankments (PGSE) provides rapid construction as well as economic benefits. Rational range of pile spacing of PRSE and PGSE are suggested based on the requirements of various railways design speeds. Furthermore, the time effectiveness of negative skin friction of piles and the action of pile-cap setting are also investigated. The relevant measures for improving the bearing capacity and two parts of transition zone forms as positive control mean have been suggested.

Numerical FEM assessment of soil-pile system in liquefiable soil under earthquake loading including soil-pile interaction

  • Ebadi-Jamkhaneh, Mehdi;Homaioon-Ebrahimi, Amir;Kontoni, Denise-Penelope N.;Shokri-Amiri, Maedeh
    • Geomechanics and Engineering
    • /
    • 제27권5호
    • /
    • pp.465-479
    • /
    • 2021
  • One of the important causes of building and infrastructure failure, such as bridges on pile foundations, is the placement of the piles in liquefiable soil that can become unstable under seismic loads. Therefore, the overarching aim of this study is to investigate the seismic behavior of a soil-pile system in liquefiable soil using three-dimensional numerical FEM analysis, including soil-pile interaction. Effective parameters on concrete pile response, involving the pile diameter, pile length, soil type, and base acceleration, were considered in the framework of finite element non-linear dynamic analysis. The constitutive model of soil was considered as elasto-plastic kinematic-isotropic hardening. First, the finite element model was verified by comparing the variations on the pile response with the measured data from the centrifuge tests, and there was a strong agreement between the numerical and experimental results. Totally 64 non-linear time-history analyses were conducted, and the responses were investigated in terms of the lateral displacement of the pile, the effect of the base acceleration in the pile behavior, the bending moment distribution in the pile body, and the pore pressure. The numerical analysis results demonstrated that the relationship between the pile lateral displacement and the maximum base acceleration is non-linear. Furthermore, increasing the pile diameter results in an increase in the passive pressure of the soil. Also, piles with small and big diameters are subjected to yielding under bending and shear states, respectively. It is concluded that an effective stress-based ground response analysis should be conducted when there is a liquefaction condition in order to determine the maximum bending moment and shear force generated within the pile.

다양한 진동하중의 액상화 시험을 통한 동적 과잉간극수압에 대한 상세분석 (Detailed Investigation on the Dynamic Excess Pore Water Pressure through Liquefaction Tests using Various Dynamic Loadings)

  • 최재순;장서용;김수일
    • 한국지진공학회논문집
    • /
    • 제11권2호
    • /
    • pp.81-94
    • /
    • 2007
  • 지진시 발생하는 지반 액상화 현상은 지진피해예측시 가장 중용하게 평가해야 하는 항목으로 실내에서 액상화 현상을 시뮬레이션하는 경우, 불규칙성의 지진을 제어하기 어려운 이유로 등가반복형태의 정현파 또는 쐐기파를 이용하는 것이 통상적이었다. 그러나, 90년대 이후 컴퓨터의 발달과 함께한 신호처리 및 제어기술의 급속한 발전은 동역학분야에서의 실험연구에 큰 도움을 주었으며 지반진동분야의 경우, 진동대 및 원심모형기와 같은 대형지진모의시험에서 실지진하중을 이용한 연구사례들이 증가되고 있는 실정이다. 국내에서도 실지진하중재하가 가능한 요소시험결과에 대한 연구사례가 발표되는 등 이에 관한 연구가 활발하게 진행되고 있으며 특히, 실지진하중 시험결과로부터 실지진하중하에서의 과잉간극수압의 변화가 정현하중시험에서의 결과와 큰 차이를 보이고 있다는 분석결과가 발표되어 현재까지 지반동역학분야에서 지진하중의 불규칙성을 크게 고려하지 않았던 통상적 가정사항들이 문제점으로 대두되어 관심을 집중시키고 있다. 본 연구에서는 등가의 정현파 및 쐐기파와 증가형태의 쐐기파, 그리고 실지진파 등 다양한 진동하중을 재하할 수 있는 삼축압축시험기를 이용하여 기존의 유효응력개념에서 사용하는 과잉간극수압관련 매개변수인 소성일, 전단소성 변형률 상각궤도, 그리고 액상화 상태전환선의 기울기를 비교분석하였으며 하중변화에 따른 토립자의 변형과 간극수압의 변화를 상세분석하였다. 연구결과, 토립자의 변형, 간극수의 동적흐름, 동적흐름 속도수두의 압력수두로의 전환, 그리고 과잉간극수압의 증가로 표현되는 새로운 개념의 액상화 발생이론을 제안하였으며 그 타당성 검토를 위해 과잉간극수압과 동적흐름의 압력수두(흐름속도의 제곱값)와의 상관관계를 비교하였다.

제방축조에 의한 연약지반의 변위특성 (Displacement Characteristics of Soft Ground by Embankment Construction)

  • 안광국;배우석
    • 한국지반환경공학회 논문집
    • /
    • 제8권2호
    • /
    • pp.29-39
    • /
    • 2007
  • 본 연구에서는 제방축조에 의해 연약점토지반에서 발생되는 지반의 변위 및 변형형태를 파악하기 위하여 제방높이, 지반의 비배수 전단강도, geotextile의 설치여부와 중력수준을 변화시키면서 원심모형시험을 실시하였다. 실험결과, 제방하중에 의한 지반의 치환단면은 geotextile을 설치하지 않은 경우 포물선 형태를 나타내었고, geotextile을 설치한 경우에는 제방하부에서 균일한 침하단면을 나타내는 사다리꼴 형태를 나타내었다. 치환각도는 제방높이와 중력수준이 증가할수록 그리고 지반의 비배수 전단강도가 작을수록 거의 선형적으로 증가하는 것으로 나타났다. 최대 수평변위가 발생하는 위치는 지표면에서 점토층 깊이의 $0.24{\sim}0.35H_0$($H_0$ : 초기 모형지반의 높이) 지점으로 평균 0.3H0인 것으로 나타났으며, geotextile을 설치하지 않은 경우 지반의 최대침하량(S)과 최대 수평변위(${\delta}_m$)는 ${\delta}_m$ = 0.54S, geotextile을 설치한 경우에는 ${\delta}_m$ = 0.60S의 관계를 나타내었다.

  • PDF

ALE 기법을 이용한 모래지반에서 석션 매입 앵커의 인발 거동 분석 (Study on Pullout Behavior of Embedded Suction Anchors in Sand using ALE (Arbitrary Lagrangian Eulerian) Technique)

  • 나선홍;장인성;권오순;이승현
    • 대한토목학회논문집
    • /
    • 제34권1호
    • /
    • pp.167-173
    • /
    • 2014
  • 석션 매입 앵커(Embedded Suction Anchor; ESA)는 석션 기초(Suction Pile or Caisson)을 이용하여 앵커를 지중에 매설한 후 인발에 저항하는 계류앵커형식이다. 본 연구에서는 ALE (Arbitrary Larangan Eulerian) Adpative Meshing 기법을 이용한 수치해석을 통해 석션 매입 앵커의 인발 거동을 모사하고, 그 결과를 기존 연구에서 수행된 원심모형 실험 및 한계 평형법을 이용한 해석적 방법의 결과와 비교 분석 하였다. 이를 통해 앵커의 수평 연직 경사 방향의 인발 거동을 평가하였으며, 수치 해석 결과, 수평 재하 시 중간 위치에서 가장 큰 저항력을 발휘하는 것으로 나타났다. 연직 재하의 경우 재하 위치와 무관하게 유사한 저항력이 발휘 되었으며, 수평 저항력이 가장 큰 중간 위치에서 경사 하중을 가한 결과 경사각이 증가할수록 인발 저항력이 감소하는 것으로 나타났다.