• Title/Summary/Keyword: Centrifugal impeller

Search Result 401, Processing Time 0.022 seconds

Experimental Study on Off-Design Performance of a Small Centrifugal Compressor for Gas Turbine Applications (가스터빈용 소형 원심압축기의 탈설계점 성능에 관한 실험연구)

  • Oh, JongSik;Lee, HeonSeok;Oh, KoonSup
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.211-218
    • /
    • 2000
  • Off-design experimental performance was investigated for a small centrifugal compressor, whose impeller diameter is about 125mm, used in an industrial gas turbine. Test rig was designed and manufactured with a radial inflow turbine and a combustor to supply driving power to the compressor. Static pressure was measured on the casing of the impeller, vaneless diffuser, vaned diffuser and volute. Total pressure was obtained using specially fabricated rakes at the vaned diffuser throat and exit. Circumferential nonuniformity was found, near surge, in the Impeller, vaned diffuser and volute region. Spanwise nonuniform flow from the impeller affected the total pressure defects in the vaned diffuser region. Static pressure distortion in the circumferential direction in the volute was found near surge, where the minimum occurred near 140 degree position.

  • PDF

Flow Evaluations of Centrifugal Pump Impeller Using Commercial Code (상용코드를 이용한 원심펌프 임펠러 유동평가)

  • Shim, Chang-Yeul;Hong, Soon-Sam;Kang, Shin-Hyoung
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.285-292
    • /
    • 2000
  • Numerical calculation is applied to centrifugal pump at design condition by using commercial code STAR-CD and Tascflow, and these results are compared with experimental data at impeller outlet. Numerical analysis is also performed by changing turbulence model and discretization scheme at design condition using Tascflow. Turbulence model and discretization scheme used to Tascflow are k-$\epsilon$, k-$\omega$ turbulence model and upwind, modified linear profile scheme. W;th the same turbulence model and discretization scheme, two results of STAR-CD and Tascflow are very similar. But there is significant difference in numerical results near hub and shroud of impeller with different kinds of turbulent model and discretization scheme at design condition. And with k- $\omega$ turbulence model and modified linear profile scheme, it is showed that numerical results are very similar to experimental results of impeller outlet

  • PDF

Numerical study on flows within an shrouded centrifugal impeller passage (원심회전차 내부유도장에 관한 수치해석적 연구)

  • Kim, Seong-Won;Jo, Gang-Rae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.10
    • /
    • pp.3272-3281
    • /
    • 1996
  • The flow analysis method which had been developed for the numerical calculation of 3-dimensional, incompressible and turbulent flow within an axial compressor was extended to the flow field within centrifugal impeller. In this method based on the SIMPLE(Semi Implicit Method Pressure Linked Equations) algorithm, the coordinate transformation was adopted and the standard k-.epsilon. model using wall function was used for turbulent flow analysis. The calculated flow fields have agreed very well with measurement results. Especially, 3-dimensional and viscous flow characteristics including secondary flows, jet-wake flow and decreased pressure rise along impeller passage, which can't be predicted by inviscid Q3D calculation were predicted very reasonably.

A Study on a Perfomance Analysis of the Centrifugal Pump Impeller using CFD (CFD에 의한 원심펌프 임펠러 성능해석에 관한 연구)

  • 남구만;모장오;강신정;임효남;이영호
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.89-94
    • /
    • 2002
  • A commercial CFD code is used to calculate the 3-D viscous flow field within the centrifugal pump impeller. Design conditions are changed by impeller inlet(9.3mm, 12.2mm) and outlet breadth(6.65mm, 6.85mm). Numerical calculation was performed by changing flow rate from 8 to 26m$^{3}$/hr. Computation results shows that total head is increased at the larger inlet and outlet breadth than the others. And when the flow rate is increasing, the total head was decreased. The maximum efficiency of pump is shown at the design flow rate(16m$^{3}$/hr). In this study shows that the calculated results are good agreements with analysis results of design condition.

  • PDF

A Study on Five-Axis Roughing of Impeller with Ruled Surface (룰드 곡면으로 된 임펠러의 5축 황삭 가공에 관한 연구)

  • Jang, Dong-Kyu;Lim, Ki-Nam;Yang, Gyun-Eui
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.7 s.196
    • /
    • pp.60-68
    • /
    • 2007
  • This paper presents an efficient 5-axis roughing method for centrifugal impeller. The efficient roughing is minimization of cutting time through minimizing tool tilting and rotating motions. To minimized cutting time, machining area is divided into sub-cutting regions using control points on hub curves and shroud curves of blade used to design and analyze centrifugal impeller. For sub-cutting regions, diameters of cutting tools are determined as big as possible. Then, tool paths are generated with the tilting axis and rotating axis of 5-axis machine limited and fixed, which can give more efficient machining speed and machining stability than the conventional methods. Experimental results show that the proposed method is more efficient than the conventional methods to mill with the only one cutting tool without dividing area and the previous methods to mill with simultaneous 5-axis processing with dividing area.

Off-design Performance Prediction of Centrifugal Pumps by Using TEIS model and Two-zone model (TEIS 모델과 두 영역 모델을 이용한 원심 펌프의 탈 설계 성능 예측)

  • Yoon, In-Ho;Baek, Je-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.574-579
    • /
    • 2000
  • In this study. an off-design performance prediction program for centrifugal pumps is developed. To estimate the losses in an impeller flow passage, two-zone model and two-element in series(TEIS) model are used. At impeller exit. the mixing process occurs with an increase in entropy. In two-zone model. there are both primary zone and secondary zone for an isentropic core flow and an average of all non-isentropic streamtubes respectively. The level of the core flow diffusion in an impeller was calculated by using TEIS model. While internal losses in an impeller an automatically estimated by using the above models, some empirical correlations far estimating external losses. far example, disk friction loss, recirculation loss and leakage loss are used. In order to analyze the vaneless diffuser flow. the momentum equations for the radial and tangential directions are used and solved together with continuity and energy equations.

  • PDF

Design and Prototyping Micro Centrifugal Compressor for Ultra Micro Gas Turbine

  • Hirano, Toshiyuki;Tsujita, Hoshio;Gu, Ronglei;Minorikawa, Gaku
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.4
    • /
    • pp.426-430
    • /
    • 2009
  • In order to investigate the design method for a micro centrifugal compressor, which is the most important component of an ultra micro gas turbine, an impeller having the outer diameter of 20mm was designed, manufactured and tested. The designed rotational speed is 500,000 rpm and the impeller has a fully 3-dimensional shape. The impeller was rotated at 250,000 rpm in the present study. The experimental results of the tested compressor with the vaned and the vaneless diffusers were compared. It was found that the vaned diffuser attained the higher flow rate than the vaneless diffuser at the maximum pressure ratio. In addition the maximum pressure ratio was higher for the diffuser having a larger diffuser divergence angle at the high flow rate. These results were compared with those obtained by the prediction method used at the design stage.

Experimental Study on Stall Inception in a High-Speed Centrifugal Compressor (I) - inception Type - (원심압축기 스톨 발단에 관한 실험적 연구 (I) - 스톨 발단 과정 -)

  • Gang, Jeong-Sik;Gang, Sin-Hyeong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.10
    • /
    • pp.1436-1444
    • /
    • 2001
  • Stall inception in a high-speed centrifugal compressor has been examined. The main objective was to find stall precursor and to develop a reliable stall warning method. Eight equally spaced fast-response pressure transducers in the inducer detected the spatial structure of small amplitude perturbations, via spatial Fourier transform, as stall is approached. Near the stall inception point, the phase of spatial courier coefficients increased linearly with the speed of impeller relation for several impeller revolutions at all test speeds, and the spectrum at impeller frequency increased as stall is approached. These are the clear evidences that the impeller frequency participates in the stalling process.

Design Optimization of Centrifugal Pump Impellers in a Fixed Meridional Geometry using DOE

  • Kim, Sung;Choi, Young-Seok;Lee, Kyoung-Yong;Yoon, Joon-Yong
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.2
    • /
    • pp.172-178
    • /
    • 2009
  • This paper reports on an investigation (using RSM with commercial CFD software) of the performance characteristics of the impeller in a centrifugal pump. Geometric parameters of vane plane development were defined with the meridional shape and frontal view of the impeller. The parameters are focused on the blade-angle distributions through the impeller in a fixed meridional geometry. For screening, a $2^k$ factorial design has been used to identify the important design parameters. The objective functions are defined as the total head rise and the total efficiency at the design flow-rate. From the $2^k$ factorial design results, it is found that the incidence angles and the exit blade angle are the most important parameters influencing the performance of the pump.

Design Optimization of Centrifugal Pump Impeller Using DOE (실험계획법을 사용한 원심펌프 임펠러 최적설계)

  • Kim, Sung;Choi, Young-Seok;Yoon, Joon-Yong;Kim, Deok-Su
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.3
    • /
    • pp.36-42
    • /
    • 2008
  • In this paper, the performance characteristics of the impeller in a centrifugal pump were investigated using DOE(Design of Experiment) with commercial CFD software. Geometric parameters of vane plane development were defined with the meridional shape and frontal view of the impeller. The incidence angles and the exit blade angle were selected as main parameters using 2k factorial and the influences of selected design parameters were examined through the optimization process using RSM.