• 제목/요약/키워드: Centrifugal fan system

검색결과 34건 처리시간 0.024초

흡입저항이 높은 원심홴 소음특성에 관한 연구 (Study on the Noise Characteristic of Centrifugal Fan operating at High Pressure Region)

  • 정윤영;박진원;전완호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1011-1014
    • /
    • 2006
  • Turbo blower generates high peaks when it operates at high pressure region. The fan of the air-cleaner system, operates especially high pressure region due to several filters, generates high noise level. In this case, the tonal sound of BPF makes people annoyance. The blower of air-cleaner has several high resistance filters in its inlet area and rotates above 900rpm Moreover, for the compact design, the size of the blower should be reduced 10%. The reduced diameter of blower makes low flow rate and high noise level. In order to reduce the noise, new blade shape was suggested and optimized

  • PDF

배기용 Fan Scroll에 대한 연구 (A Study on the Fan and Scroll for Ventilation)

  • 송성배;박성일;이준세
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.402-406
    • /
    • 2000
  • In the Over-The-Range, the outlet size is limited by the industrial standards. Therefor to enlarge the volume of cavity, the installation height of ventilation fan is become small, the system resistance is higher than before. For that reason, the important design variables such as the diameter of a fan, the scroll expansion angle, etc. which play the significant role on flow rate and noise, are confined. In this study, we made an experiment of the diameter of fans relation to scroll expansion angle and investigated flow rate of the length of fans in enlarged cavity volume of OTR, and then we designed the new scroll to improve the flow rate and noise level. As a result, flow rate increased to 110% compared to current scroll and the blade passing frequency of a fan is disappeared by inclined cut-off shapes.

  • PDF

팬-모터의 구조 및 전자기적 특성을 고려한 선박용 원심 팬의 순음 저감 분석 (Analysis for the Reduction of Tonal Noise in the Centrifugal Fan for the Ship Considering Structural and Electromagnetic Characteristics of the Fan-Motor System)

  • 한형석;장천익;이상구;구자훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.359-367
    • /
    • 2008
  • The maximum sound pressure level in a ship is restricted by the international standard such as MIL-Std. 740-1 in order to protect hearing ability for the crew on a ship. Especially, the noise of a fan system is restricted by the maximum level of the sound power according to the military specification such as MIL-F-1900A. In this paper, the reduction of tonal noise for the fan-motor system on a ship is described related to the electrical as well as structural problems. For the electrical problems, the difference of the magnetic flux caused by the variation of the air-gap is described related to the bad concentricity of the motor housing and the shaft-bearing. And for the structural problem, the resonance of the fan motor system is described.

  • PDF

원심압축기 소음측정과 계산에 관한 연구 (An Experimental and Numerical Study on Centrifugal Compressor Noise)

  • 선효성;엄승신;신형기;이수갑
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.119-124
    • /
    • 2000
  • The 3-stage centrifugal compressor is used in order to measure the noise spectra of compressor, and analyze the results. Two cases are investigated for compressor noise components. Case I includes total system such as compressor, inter-cooler, motor, and Case II excludes cooling system. BPF tonal noise is important in compressor, and cooling system including inter-cooler contributes to broadband noise. Also, motor, gear box, and motor cooling fan are the second contributions to total compressor noise. Centrifugal compressor flow-field is calculated using two-dimensional grid and Navier-Stokes equations. Static pressure increases, and total pressure decreases, as air passes through the compressor components.

  • PDF

Redesign and Evaluation of a Chickpea Harvester

  • Golpira, H.
    • Journal of Biosystems Engineering
    • /
    • 제40권2호
    • /
    • pp.102-109
    • /
    • 2015
  • Purpose: Slow manual harvesting of rain-fed chickpeas cultivated in fallow fields in developing countries have encouraged the design of a mechanical harvester. Methods: A tractor-pulled harvester was built, in which a modified stripper header detached pods from an anchored plant and a chain conveyor transferred material. The stripper harvester was redesigned to use: 1) the maneuverability of tractor-mounted frames, 2) the adaptability of floating headers, and 3) the flexibility of pneumatic conveyors. Results: A mobile vacuum conveyor, which was an innovator open system, was designed for the dilute phase transferring mode for both grain and material other than grain. A centrifugal fan transferred harvested material to a cyclone separator that settled harvested material in a grain tank 1 m high. The machine at the spot work rate of $0.42ha{\cdot}h^{-1}$ harvested chickpea pods equal to the output of 16.6 farm laborers. Conclusion: The low cost and reasonable projected purchase price are the advantages of the concept. Additionally, the shattering loss reduction confirms the feasibility of the prototype chickpea harvester for commercialization.

리어가이더 형상변화에 따른 횡류홴 성능해석 (Analysis of Performance of Cross-Flow Fan with Various Rear Guiders)

  • 김동원;이준환;박성관;김윤제
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.2076-2082
    • /
    • 2003
  • A cross-flow fan is widely used on many industrial fields: mining industry, automobile and home appliances, etc. The design point of the cross-flow fan is generally based on the region within low static pressure and high flow rate. It relatively makes high dynamic pressure at low speed because a working fluid passes through an impeller blade twice. However, it has low static pressure efficiency between 30% and 40% because of relative high impact loss. Recently, in the air-conditioning systems, the operating behaviors at the off-design points are highly regarded to broaden the application area for various air-cooling loads. Especially, at the lower flow rate, there exists a rapid pressure head reduction, a noise increase and an irregular flow field against a rearguider as a scroll of centrifugal fan. Numerical analyses are carried out for investigating the flow characteristics in a cross-flow fan including the impeller, the rearguider and the stabilizer. Especially, various types of rearguiders are estimated by numerical and experimental methods to insure the stable operation in the region of lower flow rate. Numerical domains are discretized by hexahedral cells. Three-dimensional, unsteady governing equations are solved using FVM, PISO algorithm, sliding grid system and standard ${\kappa}-{\varepsilon}$ turbulence model. ASHRAE standard fan tester is also used to estimate the performance of the modeled crossflow fan.

  • PDF

재생형 송풍기의 고효율 저소음 설계를 위한 통합형 최적설계 프로그램 개발 (Development of An Integrated Optimal Design Program for Design of A High-Efficiency Low-Noise Regenerative Fan)

  • 허만웅;김진혁;서태완;구경완;이충석;김광용
    • 한국유체기계학회 논문집
    • /
    • 제17권1호
    • /
    • pp.35-40
    • /
    • 2014
  • A multi-objective optimization of a regenerative fan for enhancing the aerodynamic and aeroacoustic performance was carried out using an integrated fan design system, namely, Total FAN-Regen$^{(R)}$. The Total FAN-Regen$^{(R)}$ was developed for non-specialists to carry out a series of design process, viz., computational preliminary design, three-dimensional aerodynamic and aeroacoustic analyses, and design optimization, for a regenerative fan. An aerodynamic analysis of the regenerative fan was conducted by solving three-dimensional Reynolds-averaged Navier-Stokes equations using the shear stress transport turbulence model. And, an aeroacoustic analysis of the regenerative fan was implemented in a finite/infinite element method by solving the variational formulation of Lighthill's analogy based on the results of the unsteady flow analysis. An optimum shape obtained by Total FAN-Regen$^{(R)}$ shows the enhanced efficiency and decreased sound pressure level as much as 1.5 % and 20.0 dB, respectively, compared to those of the reference design. The performance test was carried out for an optimized regenerative fan to validate the performance of the numerically predicted optimal design.

수치해석적 기법을 이용한 횡류홴 성능 평가 (Performance Estimation of Cross-Flow Fan by Numerical Method)

  • 김동원;이준화;박성관;김윤제
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.152-157
    • /
    • 2002
  • A cross-flow fan is widely used on many industrial fields: a blower for the general industry, mining industry, automobile and home appliances. The design point of the cross-flow fan is generally chosen by based on the region within low static pressure and high flow rate. It relatively makes high dynamic pressure at low speed because a working fluid passes through an impeller blade twice. However, it has low static pressure efficiency between $30\%$ and $40\%$ because of relative high impact loss. Recently, in the air-conditioning systems, the operating behaviors at the off-design points are highly regarded to broaden the application area for various air-cooling loads. Especially, at the low flow rate, there exists a rapid pressure head reduction, a noise increase and an irregular flow against a rearguider as a scroll of centrifugal fan. Numerical analyses are carried out for cross-flow fan including the impeller, the rearguider and the stabilizer. Numerical domains are discretized by hexahedral cells. Three-dimensional, unsteady governing equations are solved using FVM, SIMPLE algorithm, sliding grid system and standard k-$\epsilon$ turbulence model.

  • PDF

자동차 HVAC용 Blower Unit 내부 유동장의 PIV 계측 (PIV Measurement of Flow Inside of HVAC Blower Unit)

  • 지호성;김보람;이상준
    • 한국자동차공학회논문집
    • /
    • 제15권5호
    • /
    • pp.165-173
    • /
    • 2007
  • Flow characteristics inside a blower unit of an automotive HVAC module were investigated experimentally using a high-resolution PIV technique. The PIV system consists of a 2-head Nd:YAG laser, a high-resolution CCD camera, optics and a synchronizer. The prototype siroco-fan with forward-curved blades was operated under the same condition of real car. The scroll casing was made transparently for capturing clear flow images. The time-averaged velocity fields were measured in three cross sections. Flow is accelerated with going toward the outer wall of scroll due to centrifugal force and large pressure gradient formed in the region between the fan and the outer casing wall. The presence of the cut-off region and diffusing duct of fan outlet influences largely the flow structure inside the blower unit.

Measurements of Minute Unsteady Pressure on Three-Dimensional Fan with Arbitrary Axis Direction

  • Hirata, Katsuya;Fuchi, Takuya;Onishi, Yusuke;Takushima, Akira;Sato, Seiji;Funaki, Jiro
    • International Journal of Fluid Machinery and Systems
    • /
    • 제3권1호
    • /
    • pp.1-10
    • /
    • 2010
  • The present study is a fundamental approach to develop the measuring technology for minute fluctuating pressures on the three-dimensional blade surfaces of the fan which rotates with an arbitrary rotation-axis direction. In this situation, we are required to correct the centrifugal-force effect, the gravitational-force effect and the other leading-error effects for accurate measurements of the minute pressures. The working fluid is air. A pressure transducer rotating with an arbitrary attitude is closely sealed by a twofold shroud system. The rotational motion with an arbitrary attitude is produced by fixing the pressure transducer to the cantilever which is connected to a motor-driven disc of 500mm in diameter and 5mm in thickness. As a result, we have quantitatively determined main governing effects upon the non-effective component of the pressure-transducer signal.