• Title/Summary/Keyword: Central venous Catheter

Search Result 93, Processing Time 0.024 seconds

Acute Cardiac Tamponade, Report of 6 Cases (각종 원인에 의한 급성 Cardiac Tamponade: 6례 보고)

  • 조장환;이명진;홍승록
    • Journal of Chest Surgery
    • /
    • v.5 no.2
    • /
    • pp.97-106
    • /
    • 1972
  • We will report 6 cases of cardiac tamponade treated surgically at Severance Hospital during the past 9 years from 1964 to 1972 and reviewed literatures on cardiac tamponade. The age of patients was from 13 years to 45 years old. The male was 4 cases and the female 2 cases. The sites of injury were right atrium; 1 case, right ventricle; 2 cases, right ventricle and coronary artery; 1 case, left atrium; 1 case, and left ventricle; 1 case. 2 cases of cardiac tamponade developed following chest injury, 2 cases following pericardiocentesis,1 case due to continuous bleeding from sutured cardiotomy wound of left atrium following open mitral commissurotomy using cardiopulmonary bypass machine, and 1 case due to traumatic penetration of polyethylene catheter through right ventricle to pericardial sac, introduced via right jugular vein in order to monitor the central venous pressure. Central venous pressure was checked preoperatlvely in 5 cases. In all cases, central venous pressure was rised [the range of central venous pressure was 240 to 330 mmHg]. Immediately after operation,central venous pressure lowered to normal [the range was 80-100 mmHg]. Recently serial gas analysis of arterial blood were checked pre- and post-operatively for the evaluation of hemodynamic change of cardiac tamponade, but our data was not enough for evaluation. It should be studied further.

  • PDF

Ultrasound-guided internal jugular vein catheterization in critically ill pediatric patients

  • Yang, Eu Jeen;Ha, Hyeong Seok;Kong, Young Hwa;Kim, Sun Jun
    • Clinical and Experimental Pediatrics
    • /
    • v.58 no.4
    • /
    • pp.136-141
    • /
    • 2015
  • Purpose: Continuous intravenous access is imperative in emergency situations. Ultrasound-guided internal jugular vein (IJV) catheterization was investigated in critically ill pediatric patients to assess the feasibility of the procedure. Methods: Patients admitted to the pediatric intensive care unit between February 2011 and September 2012 were enrolled in this study. All patients received a central venous catheter from attending house staff under ultrasound guidance. Outcome measures included successful insertion of the catheter, cannulation time, number of cannulation attempts, and number and type of resulting complications. Results: Forty-one central venous catheters (93.2%) were successfully inserted into 44 patients (21 males and 23 females; mean age, $6.54{\pm}1.06$ years). Thirty-three patients (75.0%) had neurological disorders. The right IJV was used for catheter insertion in 34 cases (82.9%). The mean number of cannulation attempts and the mean cannulation time was $1.57{\pm}0.34$ and $14.07{\pm}1.91$ minutes, respectively, the mean catheter dwell time was $14.73{\pm}2.5$ days. Accidental catheter removal was observed in 9 patients (22.0%). Six patients (13.6%) reported complications, the most serious being catheter-related sepsis, which affected 1 patient (2.3%). Other complications included 2 reported cases of catheter malposition (4.6%), and 1 case each of arterial puncture (2.3%), pneumothorax (2.3%), and skin infection (2.3%). Conclusion: The results suggest that ultrasound-guided IJV catheterization can be performed easily and without any serious complications in pediatric patients, even when performed by visiting house staff. Therefore, ultrasound-guided IJV catheterization is strongly recommended for critically ill pediatric patients.

Factors Associated with Central Venous Catheterization in Cancer Patients (암환자의 중심정맥관 삽입 예측요인)

  • Park, Jeong-Yun;Park, Yeon-Hwan
    • Asian Oncology Nursing
    • /
    • v.11 no.1
    • /
    • pp.1-8
    • /
    • 2011
  • Purpose: The purpose of this study was to identify the types of venous access devices (VAD) for cancer patients and investigate the factors related to the insertions of central venous catheter (CVC) in cancer patients. Methods: The subjects were 379 cancer patients. A retrospective review of all patients who were discharged from a cancer unit from November 1st to 21st in 2008 was done using a structured questionnaire. Results: A total of 82 CVC (21.6%) was inserted among 379 patients for administering anticancer therapy. There were statistically significant differences in age, length of stay (LOS), cumulative LOS, medical department, history of CVC insertion, cancer category, and albumin level between patients using peripheral intravenous (IV) catheters and CVC. In addition, factors influencing the use of CVC were LOS (odds ratio [OR]=0.286, confidence interval [CI]=1.043-1.124), history of CVC insertion (OR=3.920, CI=0.128-0.637), albumin level (OR=1.010, CI=1.879-8.179), cumulative LOS (OR=1.010, CI=1.001-1.018), and hematological diseases (OR=4.863, CI=2.162-10.925). Conclusion: We found that central venous catheterization for anticancer therapy was minimal even though CVC was safe and effective device for IV access. It is necessary to develop a strategy to use VADs efficiently and timely for cancer patients.

Perforation of azygos vein and right-sided hydrothorax caused by peripherally inserted central catheter in extremely low birth weight infant (초극소 저출생 체중아에서 중심 정맥 도관술로 발생한 홀정맥 파열과 우측 흉수증 1례)

  • Ha, Kee Soo;Shin, Jung Yeon;Hwang, Mi Jung;Choi, Young Ok;Shin, Dong Han;Jang, Gi Young;Choi, Byung Min;Yoo, Kee Hwan;Hong, Young Sook;Son, Chang Sung
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.8
    • /
    • pp.902-905
    • /
    • 2006
  • We report a case in which routine chest roentgenograms of an 840 g infant led to the belief that the peripherally inserted central catheter (PICC) was appropriately positioned within the superior vena cava when, in actuality, it was within the azygous arch. Although many cases of pleural effusions have been reported to be caused by a central venous catheter, a right-sided hydrothorax caused by azygous vein rupture from the use of a PICC is an extremely rare complication. Sudden changes in the condition of a preterm infant with PICC should raise the suspicion of a catheter-related problem.

Two-Year Hospital-Wide Surveillance of Central Line-Associated Bloodstream Infections in a Korean Hospital

  • Seo, Hye Kyung;Hwang, Joo-Hee;Shin, Myoung Jin;Kim, Su young;Song, Kyoung-Ho;Kim, Eu Suk;Kim, Hong Bin
    • Journal of Korean Medical Science
    • /
    • v.33 no.45
    • /
    • pp.280.1-280.9
    • /
    • 2018
  • Background: Surveillance and interventions of central line-associated bloodstream infections (CLABSIs) had mainly been targeted in intensive care units (ICUs). Central lines are increasingly used outside ICUs. Therefore, we performed a hospital-wide survey of CLABSIs to evaluate the current status and develop strategies to reduce CLBASI rates. Methods: All hospitalized patients with central venous catheters (CVCs) were screened for CLABSIs from January 2014 through December 2015 at a 1,328 bed tertiary care teaching hospital in Korea using an electronic data-collecting system. Clinical information including type of CVC was collected. CLABSI rates were calculated using the definitions of the National Health and Safety Network after excluding mucosal barrier injury laboratory-confirmed bloodstream infection (BSI). Results: A total of 154 CLABSIs were identified, of which 72 (46.8%) occurred in general wards and 82 (53.2%) in ICUs (0.81 and 2.71 per 1,000 catheter days), respectively. Nontunneled CVCs were most common (68.6%) among 70 CLABSI events diagnosed within one week of their maintenance. On the other hand, tunneled CVCs and peripherally inserted central catheters (PICCs) were more common (60.5%) among 114 CLABSI events diagnosed more than a week after maintenance. Whereas the majority (72.2%) of CLABSIs in ICUs were associated with non-tunneled CVCs, tunneled CVCs (38.9%) and PICCs (36.8%) were more common in general wards. Conclusion: CLABSIs are less common in general wards than in ICUs, but they are more often associated with long-term indwelling catheters. Therefore, interventions to prevent CLABSIs should be tailored according to the type of ward and type of catheter.

Imaging of Umbilical Venous Catheter-Related Hepatic Complications in Neonates (신생아의 제대 정맥 카테터와 관련된 간 합병증의 영상 소견)

  • Min Ju Kim;So-Young Yoo;Tae Yeon Jeon;Ji Hye Kim;Yu Jin Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.3
    • /
    • pp.586-595
    • /
    • 2023
  • An umbilical venous catheter (UVC) is commonly placed for central venous access in preterm or critically ill full-term neonates to provide total parenteral nutrition (TPN) and medication. However, UVCs can result in complications, including infection, portal vein thrombosis, and hepatic tissue injury. The inadvertent administration of hypertonic fluid through a malpositioned UVC can also cause hepatic parenchymal damage with mass-like fluid collection that simulates a tumorous condition during imaging. Ultrasonography and radiographic examinations play an essential role in detecting UVC-related complications. This pictorial essay aims to present the imaging findings of UVC-related hepatic complications in neonates.

Acute mediastinitis secondary to delayed vascular injury by a central venous catheter and total parenteral nutrition

  • Byeon, Gyeong-Jo;Kim, Eun-Jung;Yoon, Ji-Young;Yoon, Seok-Hyun;Woo, Mi-Na;Kim, Cheul-Hong
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.15 no.1
    • /
    • pp.31-34
    • /
    • 2015
  • Vascular injury caused by a central venous catheter (CVC) has been reported to be a rare complication, especially delayed vascular injury due to CVC has a few cases and it can be fatal because of delayed recognition and more serious complications. A 59-year-old woman with no available medical history was admitted for treatment of ovarian cancer. For the surgery, a triple-lumen CVC was placed through the left subclavian vein. Parenteral nutrition through the CVC was used for postoperative nutritional management in the first postoperative day. On the sixth postoperative day (POD), the patient suddenly complained of dyspnea. The CT revealed bilateral pleural effusion and irregular soft tissue density and air bubble in anterior mediastinum suggesting migration of the distal portion of the CVC into the anterior mediastium. In the intensive care unit (ICU) bilateral thoracentesis and percutaneous drainage were performed. She was discharged from the ICU in 3 days later and transferred to the general ward. This case emphasizes the possibility of the delayed vascular injury related to CVC and some strategies for prevention of vascular injury.

Two Cases of Fractured and Embolized Implanted Central Venous Chemoports in Lung Cancer (폐암환자에서 발생한 피하매몰 중심정맥포트 골절 및 색전증 2예)

  • Ju, Jin Yung;Cho, Jae Yeong;Lim, Jung Hwan;Cho, Gye Jung;Chae, Dong Ryeol;Oh, In Jae;Kim, Kyu Sik;Kim, Yu Il;Lim, Sung Chul;Kim, Young Chul;Song, Sang Yoon;Na, Kook Ju;Kim, Yun Hyun;Kim, Jae Kyu
    • Tuberculosis and Respiratory Diseases
    • /
    • v.63 no.5
    • /
    • pp.449-453
    • /
    • 2007
  • Totally implanted central venous access devices for chemotherapy (chemoport) are being used increasingly in lung cancer patients. Vascular catheters are associated with various complications including infection, thrombosis as well as spontaneous fractures and embolization of the catheter, which is known as 'pinch-off syndrome'. 'Pinch-off syndrome' refers to the compression of a subclavian central venous catheter between the clavicle and first rib resulting in an intermittent or permanent obstruction, which can lead to tears, transection, or embolization. We report two cases of fractured and embolized implanted subclavian venous catheters in which the fragments were removed percutaneously. A 62-year-old man presented with back pain with a duration of a few weeks. The chest radiograph revealed complete transsection and embolization of the catheter into the right atrium. In addition, a 47-year-old woman with a chemoport had a grade 3 pinch-off sign in a chest radiograph demonstrating complete transsection and embolization of the catheter into the pulmonary artery. Both cases were managed by retrieving the embolized distal fragment percutaneously and removing the proximal section of the catheter.

In vitro Retention of Antimicrobial Activity of Ciprofloxacin-incorporated Central Venous Catheters

  • Jeon, Sung-Min;Kim, Mal-Nam
    • Biomedical Science Letters
    • /
    • v.13 no.3
    • /
    • pp.175-182
    • /
    • 2007
  • In vitro ciprofloxacin (CFX)-release study and bioassay using microorganisms were performed to estimate the retention of the antimicrobial activity of the CFX-incorporated central venous catheters (CFX-CVCs). The release experiments were carried out under the optional CFX-release conditions to mimic the in vivo environment. The release of CFX experienced an initial burst followed by a slow and steady matrix-diffusion controlled release. The 1.0CP (polyurethane catheter containing 1.0% (w/w) of CFX) under dynamic condition showed a near zero-order CFX release profile, which is beneficial for the long-tenn antimicrobial activity. The modified Kirby-Bauer method was performed employing S. aureus and E. coli to evaluate the retention of antimicrobial activity of the catheters retrieved from the release experiments. The 1.0CP showed the long-term antimicrobial activity (${\geq}\;21$ days) against both S. aureus and E. coli. These results indicate that 1.0CP is useful as a long-tenn indwelling CVC.

  • PDF

Antibacterial Activity of Ciprofloxacin-incorporated Central Venous Catheters and its Mechanism Against Planktonic Bacterial Cells

  • Jeon, Sung-Min;Kim, Mal-Nam
    • Biomedical Science Letters
    • /
    • v.15 no.1
    • /
    • pp.73-80
    • /
    • 2009
  • Bloodstream infections (BSI) are caused by planktonic microorganisms, sometimes leading to serious infections such as bacteremia and sepsis. BSI occurs more frequently to the patients wearing the central venous catheter (CVC). The ciprofloxacin-incorporated CVC (CFX-CVC) has been reported previously to possess antimicrobial activity. In this study, the antibacterial activity of CFX-CVC and its mechanism against planktonic BSI cells were explored by using the shake flask test and by examining the release rate of 260 nm-absorbing substances from the bacterial cells indicative of the membrane damage of the bacterial cells. CFX-CVC reduced more than 99.9% of the viable planktonic BSI cells demonstrating its potent antibacterial activity. It provoked bacteriolysis causing leakage of a large amount of 260 nm-absorbing materials from the planktonic bacterial cells like S. aureus and E. coli. These results provide evidence that the antibacterial activity of CFX-CVC came from the inhibition of the stability of the planktonic bacterial cells.

  • PDF