• Title/Summary/Keyword: Central fatigue

Search Result 113, Processing Time 0.025 seconds

Comparison with Threshold Limit Value (TLV) of Menthol Cigarettes between Expert and Consumer Panel

  • Lee Seung-Yong;Lee Whan-Woo;Kim Young-Hoh
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.28 no.1
    • /
    • pp.58-66
    • /
    • 2006
  • Threshold limit value (TLV) test between expert and consumer panel was conducted about absolute, recognition and difference threshold respectively. And we tried to suggest appropriate and minimum acceptable menthol concentration level by consumer panel. Determination of threshold value was based on ASTM E 679-79 method by forced-choice ascending concentration series. In addition, a semi-ascending paired difference method was referred to conduct test. The group threshold value was determined as the value of geometric mean individual threshold. The smokers were dividend by two groups, trained and consumer panel. Trained panel was selected according to sensitivity to menthol discrimination. Consumer panel wasrecruited in proportion as population ratios including female smokers. They were all over twenty years old volunteers and summed up thirty four persons. In terms of sensor evaluation, overall difference test with seven-category scale by both trained and consumer panelists were done. On judging correct or incorrect answer, two by three cut-off levels applied to. Every test was conducted with two sessions, before smoking and during smoking period. And, only two samples served each paneI per test with regard to sensory fatigue and reliable results. All tests were replicated, and in total 32 times per panelist. In conclusion, the recognition threshold about consumer and expert panel was 358 ppm/cig. and 276 ppm/cig. in separately. Besides, absolute and difference thresholds were obtained also. And, we conduct difference threshold test with two different ways, upward and downward. And, The results of each method were 246, 195 ppm/cig., 1414, 1336 ppm/cig. and 1047, 972 ppm/cig.

Fatigue Durability Evaluation of Refraction Expansion Joints (굴절형 신축이음장치의 피로내구성 평가)

  • Na, Jun-Su;Lee, Ta;Han, Eui-Seok;Sung, Won-Kyu;Lee, Jong-Suk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.10-15
    • /
    • 2017
  • The refraction expansion joints have been newly developed by complementing the problems of shock, noise, replaceability, displacement in the direction perpendicular to bridge, vertical difference, which are problems of existing expansion joints. The Refraction expansion joints are characterized by continuous surfaces with small impact and low noise. The behavior of the Refraction expansion joints performs the bridge expansion behavior by rotation of the link. In the rotational behavior of the link, the bolt is the central axis of the behavior. Therefore, it can be said that the durability of the bolt is very important. However, the theoretical and experimental verification of the bolt durability of the Refraction expansion joint is lacking. In this paper, to verify the fatigue durability of the bolt, test specimens with a 300 mm Refraction expansion joint were fabricated. A strain gauge dedicated to the bolt was installed inside the manufactured test specimen bolt. The test method was applied in accordance with KS F 4425. The fatigue durability of the bolts assembled inside the diaphragm expansion joint was confirmed by the repeated fatigue test of 2,000,000 cycles.

Experimental study on ductile crack initiation in compact section steel columns

  • Luo, Xiaoqun;Ge, Hanbin;Ohashi, Masatoshi
    • Steel and Composite Structures
    • /
    • v.13 no.4
    • /
    • pp.383-396
    • /
    • 2012
  • In order to develop a verification method for extremely low cycle fatigue (ELCF) of steel structures, the initiation mechanism of ductile cracks is investigated in the present study, which is the first step of brittle fracture, occurred in steel bridge piers with thick-walled sections. For this purpose, a total of six steel columns with small width-thickness ratios were tested under cyclic loading. It is found that ductile cracks occurred at the column base in all the specimens regardless of cyclic loading histories subjected. Moreover, strain history near the crack initiation location is illustrated and an index of energy dissipation amount is proposed to evaluate deformation capacity of structures.

바이오센서

  • 홍승홍
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.2
    • /
    • pp.109-111
    • /
    • 1989
  • An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients.

  • PDF

Rotatory Vertebral Artery Syndrome in Foramen Magnum Stenosis (대공협착에서 발생한 회전척추동맥증후군)

  • Jung, Ileok;Jung, Jin-Man;Park, Moon Ho
    • Research in Vestibular Science
    • /
    • v.17 no.4
    • /
    • pp.167-169
    • /
    • 2018
  • Rotatory vertebral artery syndrome (RVAS) is characterized by recurrent attacks of vertigo, nystagmus, and syncope induced by compression of the vertebral artery during head rotation. A 60-year-old man with atlas vertebrae fracture presented recurrent attacks of positional vertigo. Left-beat, upbeat and count clock-wise torsional nystagmus occurred after lying down and bilateral head roll (HR) showing no latency or fatigue. Magnetic resonance imaging revealed foramen magnum stenosis (FMS) and dominancy of right vertebral artery (VA). The flow of the right VA on transcranial Doppler decreased significantly during left HR. The slower the velocity was, the more the nystagmus was aggravated. RVAS can be evoked by FMS causing compression of the VA. And the nystagmus might be aggravated according to the blood flow insufficiency.

Dynamic response of cable-stayed bridges subjected to sudden failure of stays - the 2D problem

  • Raftoyiannis, I.G.;Konstantakopoulos, T.G.;Michaltsos, G.T.
    • Coupled systems mechanics
    • /
    • v.3 no.4
    • /
    • pp.345-365
    • /
    • 2014
  • A significant problem met in engineering practice when designing cable-stayed bridges is the failure of cables. Many different factors can lead to sudden failure of cables, such as corrosion, continuous friction or abrasion, progressive and extended crevice created by fatigue and finally an explosion caused by sabotage or accident, are some of the causes that can lead to the sudden failure of one or more cables. This paper deals with the sudden failure of cables in a special form of cable-stayed bridges with a single line of cables anchored at the central axis of the deck's cross-section. The analysis is carried out by the modal superposition technique where an analytical method developed by the authors in a previous work has been employed.

Improvement of Fatigue Life with Local Reinforcement for Offshore Topside Module during Marine Transportation (해양플랫폼 탑사이드 모듈의 해상 운송 시 국부 보강을 통한 피로 수명 개선에 관한 연구)

  • Jang, Ho-Yun;Seo, Kwang-Cheol;Park, Joo-Shin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.2
    • /
    • pp.387-393
    • /
    • 2021
  • In this study, finite element analysis was performed to evaluate a method of increasing the fatigue life of the pipe connection structure commonly used in the topside structure of offshore platforms. MSC Patran/Nastran, a commercial analysis program, was used, and the critical structural model was selected from the global analysis. To realize the stress concentration phenomenon according to the load, modeling using 8-node solid elements was implemented. The main loads were considered to be two lateral loads and a tensile load on a diagonal pipe. To check the hotspot stress at the main location, a 0.01 mm dummy shell element was applied. After calculating the main stress at the 0.5-t and 1.5-t locations, the stress generated in the weld was estimated through extrapolation. In some sections, this stress was observed to be below the fatigue life that should be satisfied, and reinforcement was required. For reinforcement, a bracket was added to reduce the stress concentration factor where the fatigue life was insufficient without changing the thickness or diameter of the previously designed pipe. Regarding the tensile load, the stress in the bracket toe increased by 23 %, whereas the stress inside and outside of the pipe, which was a problem, decreased by approximately 8 %. Regarding the flexural load, the stress at the bracket toe increased by 3 %, whereas the stress inside and outside of the pipe, which was also a problem, decreased by approximately 48 %. Owing to the new bracket reinforcement, the stress in the bracket toe increased, but the S-N curve itself was better than that of the pipe joint, so it was not a significant problem. The improvement method of fatigue life is expected to be useful; it can efficiently increase the fatigue life while minimizing changes to the initial design.

Fatigue resistance, debonding force, and failure type of fiber-reinforced composite, polyethylene ribbon-reinforced, and braided stainless steel wire lingual retainers in vitro

  • Foek, Dave Lie Sam;Yetkiner, Enver;Ozcan, Mutlu
    • The korean journal of orthodontics
    • /
    • v.43 no.4
    • /
    • pp.186-192
    • /
    • 2013
  • Objective: To analyze the fatigue resistance, debonding force, and failure type of fiber-reinforced composite, polyethylene ribbon-reinforced, and braided stainless steel wire lingual retainers in vitro. Methods: Roots of human mandibular central incisors were covered with silicone, mimicking the periodontal ligament, and embedded in polymethylmethacrylate. The specimens (N = 50), with two teeth each, were randomly divided into five groups (n = 10/group) according to the retainer materials: (1) Interlig (E-glass), (2) everStick Ortho (E-glass), (3) DentaPreg Splint (S2-glass), (4) Ribbond (polyethylene), and (5) Quad Cat wire (stainless steel). After the recommended adhesive procedures, the retainers were bonded to the teeth by using flowable composite resin (Tetric Flow). The teeth were subjected to 10,00,000 cyclic loads (8 Hz, 3 - 100 N, $45^{\circ}$ angle, under $37{\pm}3^{\circ}C$ water) at their incisoproximal contact, and debonding forces were measured with a universal testing machine (1 mm/min crosshead speed). Failure sites were examined under a stereomicroscope (${\times}40$ magnification). Data were analyzed by one-way analysis of variance. Results: All the specimens survived the cyclic loading. Their mean debonding forces were not significantly different (p > 0.05). The DentaPreg Splint group (80%) showed the highest incidence of complete adhesive debonding, followed by the Interlig group (60%). The everStick Ortho group (80%) presented predominantly partial adhesive debonding. The Quad Cat wire group (50%) presented overlying composite detachment. Conclusions: Cyclic loading did not cause debonding. The retainers presented similar debonding forces but different failure types. Braided stainless steel wire retainers presented the most repairable failure type.

The Effect of Insulating Material on WLCSP Reliability with Various Solder Ball Layout (솔더볼 배치에 따른 절연층 재료가 WLCSP 신뢰성에 미치는 영향)

  • Kim, Jong-Hoon;Yang, Seung-Taek;Suh, Min-Suk;Chung, Qwan-Ho;Hong, Joon-Ki;Byun, Kwang-Yoo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.13 no.4
    • /
    • pp.1-7
    • /
    • 2006
  • A major failure mode for wafer level chip size package (WLCSP) is thermo-mechanical fatigue of solder joints. The mechanical strains and stresses generated by the coefficient of thermal expansion (CTE) mismatch between the die and printed circuit board (PCB) are usually the driving force for fatigue crack initiation and propagation to failure. In a WLCSP process peripheral or central bond pads from the die are redistributed into an area away using an insulating polymer layer and a redistribution metal layer, and the insulating polymer layer affects solder joints reliability by absorption of stresses generated by CTE mismatch. In this study, several insulating polymer materials were applied to WLCSP to investigate the effect of insulating material. It was found that the effect of property of insulating material on WLCSP reliability was altered with a solder ball layout of package.

  • PDF

Occurrence of Cognitive and Neurological Symptoms in Norwegian Dentists

  • Hilt, Bjorn;Svendsen, Kristin;Syversen, Tore;Aas, Oddfrid;Qvenild, Torgunn
    • Safety and Health at Work
    • /
    • v.2 no.2
    • /
    • pp.176-182
    • /
    • 2011
  • Objectives: Previous investigations have presented some evidence of late cognitive effects in dental personnel exposed to metallic mercury. We wanted to examine if Norwegian dentists have an increased prevalence of symptoms consistent with neurological and/or cognitive malfunction. Methods: The study group consisted of 406 dentists from central Norway and 217 controls from the general population, all under the age of 70. They had responded to a standardised postal questionnaire (Euroquest) inquiring about seven symptoms in regard to neurology, psychosomatics, memory, concentration, mood, sleep disturbances, and fatigue. A score was calculated for each symptom based on 4 to 15 single questions scored on a scale from 1 (seldom or never) to 4 (very often). Results: The dentists and controls had a participation rate of 57.2 % and 42.9 % respectively. The dentists reported no more cognitive symptoms than the controls, with low average symptom scores from 1.16 for neurological symptoms in males to 1.73 for fatigue in females. Corresponding figures for the controls were 1.22 and 1.77. There were a total of 1.2 % of the dentists and 1.8 % of the controls who reported having three or more of the seven symptoms "often" or more frequently. Conclusion: Norwegian dentists do not report more cognitive and neurological symptoms than controls from the general population.