Journal of the Korea Institute of Information and Communication Engineering
/
v.13
no.8
/
pp.1587-1592
/
2009
RFID is Playing a central role in ubiquitous technology according with the advent of the ubiquitous era, and the development of an RFID reader is also emerging as an important technical development field. In this paper, we developed a hardware system which is able to make use of the 13.56MHz RFID infrastructure being used as a transportation card, a credit card, and so on as well as the 125KHz RFID infrastructure being used in security company, and which is applicable to a location identification, an entrance and exit control, and security control over the TCP/IP communication. The existing local RFID methods have some problems which bottlenecks such as administrative problems, technical problems, and so force frequently occur because a casual server is placed and operated in a company. Hence, in this paper we developed an RFID multi reader which is connected to a central administrable server over the TCP/IP in order to solve these problems, and we make it be possible to keep an security control and be easy to install, transfer and administrate RFID infrastructures.
In this paper, a power flow control of PV hybrid module system with ESS is proposed. Photovoltaic(PV) hybrid module system is consist of individual converter, central inverter, and energy storage system(ESS). Because PV power can be changed in particular hours and environment condition, the power management control for ESS is required. In this paper, the power flow control method for PV hybrid module system with ESS is proposed. The validity of proposed control method is verified by simulations and theoretical analysis.
It is important for national safety that tank lorry or bulk lorry which is carrying toxic gas or explosive materials should be monitored during the maneuvering from starting point to destination as well as vehicle or tank status. Therefore, we propose a safety monitoring system for tank lorry to check driving condition and the vehicle status. We studied the integration of central control system with in-vehicle computer system connected with various sensors for monitoring through a communication network.
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
/
v.24
no.10
/
pp.58-66
/
2010
This paper shows an implementation and management result of wireless networks based security light control system, which performs a great role in protection of pedestrians and prevention of crime. Conventional security light units have severe limits in confirmation and inspection of security light unit failure, like wilful damage by someone or failure by influence of other equipment or failure by spontaneous heat-increase, and so on. In addition, local government offices are responsible for maintenance of security light units and as a matter of fact, most of civil complaints are about security light units. It is an obvious that the existing security light maintenance system reaches the limit and the security light maintenance problem is a difficulty of local government. Therefore, efficient security light control system is needed, which enables central control and intelligent maintenance. Moreover, the system has to be easy to control and has to be stable. In this study, wireless sensor network based security light control system is implemented, which is independent of programming language and platform, and which is simple to control and extend the system. The proven protocols, HTTP and SOAP, are utilized in order to improve the system reliability. This paper shows the excellence of our proposed system by implementing and operating it in real environment.
A power line communications, power, the outgoing line is a means of communication. DC 12 volt power lines in the system over the 2-wire control signals with the power to send the cargo configuration, and, in the basement living space, temperature, humidity, dust, CO2 sensors, and through the cooperation of the real-time detection and valves of the appropriate amount of wind, fan was designed to control. By the system's ability to communicate and control the room temperature or the status of amount of wind sent to the central system to transmit and receive signals to the center of the future, the ability to control the company said. In addition, the system HMI (Human Machine Interface) terminal by the direct control and if necessary personal portable devices to communicate with the living conditions of the underground environment in the best state that the purpose is to build.
Journal of Institute of Control, Robotics and Systems
/
v.11
no.8
/
pp.733-739
/
2005
Device Description that is described as C-based DDL(Device Description Language) should be provided for the control system to use the progressive function of field device in the distributed control system. DD expresses field device function itself and parameter. DD is used to set a necessary function far a control strategy in the central control system. DD technology which was adopted as international standard IEC 61804-Part 2 is being used in PROFIBUS, Foundation Fieldbus and HART. However, the DD is dependent to the fieldbus and it doesn't have a suitable form in the industrial Ethernet. This paper presents the possibility of a change from EDD(Electronic Device Description) and GSD(General Slave Data) used for integrating field devices to XDD(XML for Device Description) and verifies it's effectiveness. Also, this paper presents research assignment on the XML application in the distributional system from now on by examining the possibility of Ethernet`s development in the industrial area.
International conference on construction engineering and project management
/
2007.03a
/
pp.440-449
/
2007
This paper describes the efforts in developing several versions of bridge management system (BMS) in Taiwan. There were several versions of stand-alone BMS developed in Taiwan prior to the Ji-Ji earthquake that occurred in year 1999. Since many bridges were seriously damaged by this earthquake, the Ministry of Transportation and Communication determined to develop a nationwide BMS to have a better by control on the status of bridge maintenance. Implemented in year 2000, the Taiwan Bridge Management system (T-BMS) is now the dominating and mandatory system used by all the government agencies that are responsible for bridge maintenance. Having more then 25,000 bridges in its inventory, T-BMS has thousands of logins per month to update data in the relevant database. The experiences and difficulties of using such a nationwide bridge management system are discussed. Finally, future plans for BMS development are also proposed in this paper.
Su, Yang-Jin;Lee, Jae-Pil;Park, Cheon-O;Lee, Deok-Gyu;Chang, Hang-Bae
Journal of Korea Multimedia Society
/
v.13
no.8
/
pp.1212-1220
/
2010
The technologies of domestic user programs are not enough to convert address convert information, which was collected via port redirection server, to user traffic. Generally traffic redirection technology is a special purpose technology for I/O traffic via network device. L4 switch needs various additional costs and devices to achieve this special purpose. To solve this problem, there appears need for a central management of control and monitoring by centralizing traffic at one position regardless of network structure and it is necessary to realize redirection function of switch at network layer. Therefore this study offer development of traffic central control system through protocol redirection of client-side.
Vehicle platooning in automated connected vehicle systems is an efficient transportation operation model that not only significantly reduces computational load and networking overhead of the central system but also improves traffic flow. For efficient platoon group management, it is important to maintain the platoon group size appropriately and to control the merge request of a new vehicle and other group member vehicle. In this paper, we present a merger control scheme that accepts or rejects merge requests based on the current group size and the priority of vehicles. The proposed method was analyzed and validated through mathematical models based on Markov chains. Performance evaluation shows that the proposed scheme properly manages the load of the central system.
Proceedings of the Korea Society for Simulation Conference
/
2004.05a
/
pp.109-117
/
2004
In this paper, we consider the aortic sinus baroreceptor, which is the most representative baroreceptor sensing the variance of pressure in the cardiovascular system, and propose heart activity control model to observe the effect of delay time in heart period and stroke volume under the regulation of baroreflex in the aortic sinus. The proposed heart activity baroreflex regulation model contains electric circuit sub-model. We constituted the time delay sub-model to observe sensitivity of heart activity baroreflex regulation model by using the variable value to represent the control signal transmission time from the output of baroreflex regulation model to efferent nerve through central nervous system. The simulation object of this model is to observe variability of the cardiovascular system by variable value in time delay sub-model. As simulation results, we observe three patterns of the cardiovascular system variability by the time delay, First, if the time delay over 2.5 second, aortic pressure and stroke volume and heart rate is observed nonperiodically and observed. Finally, if time delay under 0.1 second, then heart rate and aortic pressure-heart rate trajectory is maintained in stable state.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.