• 제목/요약/키워드: Central X-ray

검색결과 270건 처리시간 0.023초

슬대퇴관절의 Merchant View에서 중심 X선 위치에 따른 일치각 평가 (Assessment of Congruence Angle according to the Central X-ray in the Merchant View of Patellofemoral Joint)

  • 김현진;주영철;최재호;임우택
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권6호
    • /
    • pp.423-428
    • /
    • 2019
  • The Precise measurement of the knee's Congruence angle is required for diagnosis of patella dislocation. The purpose of this study is to consider the distortion diagram and usefulness about the test of the bilateral side and one side through the evaluating congruence angle from Merchant view of patellofemoral joint to central X-ray. We've evaluated the sulcus angle and Congruence angle following central X-ray's changes when we took Merchant view of patellofemoral joint aimed to right lower limb from human whole body phantom. The subject of the evaluation was classified as normal group and varus group, and the varus group has experimented with External rotation of legs as 15° and 30°. When normal groups result as 0, 7.5, 15 cm, it was measured as 17.25 ± 1.34°, 19.60 ± 1.41°, 20.55 ± 1.77° each. The gap between minimal and maximum angle was 3.3°, and the value was shown as getting bigger when it further away from the centeral X-ray. When Congruence angle in 15° varus group was 0, 7.5, 15 cm, it was each 16.45 ± 1.34°, 17.10 ± 0.99°, 17.80 ± 1.13°. And when Congruence angle in 30° varus group was 0, 7.5, 15 cm, it was measured each 18.35 ± 1.63°, 18.95 ± 1.06°, 19.60 ± 1.41°. The difference between minimum and maximum of angle in 15° varus group and 30° varus group was each 1.35° and 1.25°, the angles have shown as increasing the further away from the center. The patellofemoral joint showed that the congruence angle increases as the further away from Central X-ray, and also it is judged that is possible to change the congruence angle by a degree of varus knee. Thus, accurate measurement of the congruence angle is shown to advantage that methods for examining by split each side at two times than methods for examining both sides at a time. Therefore, it is expected to helpful on the diagnostic side of patella dislocation and subluxation.

DISCOVERY OF VELOCITY INHOMOGENEITIES IN THE COMA, HYDRA, ABELL 2256 CLUSTER OF GALAXIES

  • Kim, Kwang-Tae
    • 천문학논총
    • /
    • 제7권1호
    • /
    • pp.39-50
    • /
    • 1992
  • A velocity inhomogeneity, which is the regional preponderence of either radial or tangential orbits, is searched with the new technique proposed by Kim (1992) for Coma, Hydra I, and Abell 2256 cluster of galaxies. Conspicuous inhomogeneities are found in the Coma and A2256 which X-ray isophotes are indicative for their underlying potentials being ellipitcal in shape, Even in their central regions, zones that are dominated by radial orbits are clearly distinguishable from that of the tangential orbits, and defining the cluster 'equator' as the direction of maximum elongation of the X-ray isophotes, radial orbits dominate along this direction whereas tangential orbits dominate the 'polar' zones. Merger events that are evidenced in X-ray observations occur in the equatorial zones of Coma and A2256, suggesting preponderence of radial orbits in the zones, which is in good agreement with their velocity structures. On the other hand, the inhomogeneity in Hydra I turns out to be insignificant in the central regions and this is just what is expected from a cluster whose X-ray isophotes is nearly circular. The velocity distribution in regions further out, however, shows significant inhomogeneity and this seems to support the previous results that this cluster is likely to have substructures and velocity anisotropy.

  • PDF

구내 방사선발생기의 선량 분포측정을 통한 필름유지기구(XCP-DS FIT)의 피폭선량감소에 대한 유용성 (Utilization-Focused Reduction of Radiation Exposure with XCP-DS FIT Sensor Holder by Measuring Dose of Dental X-ray Generator)

  • 이경희
    • 한국방사선학회논문지
    • /
    • 제6권6호
    • /
    • pp.465-471
    • /
    • 2012
  • 본 연구에서는 ALOKA PDM-117(X-ray 측정용 선량계)선량계를 이용하여 구내방사선 촬영기에서 발생하는 방사선에 대하여 거리의 변화에 따른 선량분포를 3차원으로 측정하였다. 구내 방사선촬영에 있어서 XCP 필름 유지기구(XCP-DS FIT)를 사용하여 영상을 얻는 경우 방사선의 선량 분포는 변할 수 있고 이것은 방사선영상과 환자피폭에 영향을 미치게 된다. 따라서 위치에 따른 선량을 표준화하여 XCP 필름 유지기구 사용 유무에 따른 선량과의 관계를 알아볼 필요성이 있다. 본 연구에서는 측정된 3차원 선량분포를 통하여 등각촬영시 얻을 수 있는 최적의 영상과 동일한 선량을 얻기 위한 조사시간과 거리와의 관계 및 선량분포의 모서리 퍼짐 현상에 대한 결과를 정량적으로 측정하였다. 거리가 증가함에 따라 중심 선량은 감소하였지만 조사통 가장자리 부분의 방사선 퍼짐은 증가하는 경향을 보였다. 이것은 XCP 필름 유지기구를 사용하는 경우에 선속 가장자리 부분에서 방사선의 선량이 퍼지는 경향을 보이기 때문이므로 환자의 병소이외의 부분에 대한 피폭에 주의를 기울여야 함을 정량적으로 확인 하였다. 본 연구의 결과는 품질 좋은 치아영상을 얻고, 환자의 피폭선량을 줄이는데 매우 유용하게 사용되어 질 수 있을 것으로 사료된다.

기류방출형 연X선 조사에 의한 정전기 제거 장치에 관한 연구 (A Study on the Removal of Electrostatic using Transmitted Ions Generated Soft X-ray with Compressed Air)

  • 귄승열;이동훈;최재욱;서민석
    • 한국안전학회지
    • /
    • 제25권1호
    • /
    • pp.27-31
    • /
    • 2010
  • It is a well known fact that the LCD and Semiconductor Devices are a central part of IT industry which is important in the present and the future. But the biggest problem of Semiconductor and LCD manufacturing is maintaining a cleaning room environment. For this reason, the soft X-ray type Ionizer was used as the electrostatic reducer device, which protects damage of the product against electrostatic discharge in the manufacturing process. Therefore it is a essential important factor during Semiconductor and LCD production process. But the soft X-ray has a intrinsic problem with harmful to human being in case of soft X-ray exposure. That's reason we have the research to solve above problem and made an apparatus that it was covered with shielding structure to protect X-ray radiation to outside. And besides, it has a possibility to eliminate the charged electrostatic in the narrow space through the slot for Ion emissions with dual soft X-ray sources on the both side. It is also not make the particles from itself when it has been operated.

A Novel Approach to Enhance Dual-Energy X-Ray Images Using Region of Interest and Discrete Wavelet Transform

  • Ullah, Burhan;Khan, Aurangzeb;Fahad, Muhammad;Alam, Mahmood;Noor, Allah;Saleem, Umar;Kamran, Muhammad
    • Journal of Information Processing Systems
    • /
    • 제18권3호
    • /
    • pp.319-331
    • /
    • 2022
  • The capability to examine an X-ray image is so far a challenging task. In this work, we suggest a practical and novel algorithm based on image fusion to inspect the issues such as background noise, blurriness, or sharpness, which curbs the quality of dual-energy X-ray images. The current technology exercised for the examination of bags and baggage is "X-ray"; however, the results of the incumbent technology used show blurred and low contrast level images. This paper aims to improve the quality of X-ray images for a clearer vision of illegitimate or volatile substances. A dataset of 40 images was taken for the experiment, but for clarity, the results of only 13 images have been shown. The results were evaluated using MSE and PSNR metrics, where the average PSNR value of the proposed system compared to single X-ray images was increased by 19.3%, and the MSE value decreased by 17.3%. The results show that the proposed framework will help discern threats and the entire scanning process.

이동형 방사선 차폐장치의 성능평가에 관한 연구 (A Study on the Performance Evaluation of Portable Radiation Shielding Apparatus)

  • 구본열;한상현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권4호
    • /
    • pp.289-295
    • /
    • 2018
  • When using a mobile X-ray unit, primary radiation creates medical images and secondary radiation scatters in many directions, which reduces image quality and causes exposure to patients, care givers and medical personnel. The purpose of this study was to develop a radiation shielding system for effectively shielding secondary radiation and evaluate its effectiveness. Using a mobile X-ray unit, spatial dose according to presence of human equivalent phantom and spatial dose using the developed shielding device were measured, and the phantom at 80 cm equidistance from center of X-ray was compared with spatial dose according to use of a shield. Measurements were taken at intervals of 10 cm every $30^{\circ}$ from the head direction($-90^{\circ}$) to the body direction($+90^{\circ}$). In the spatial dose measurement with and without the phantom, when the human equivalent Phantom was used, the spatial dose was increased by 40% in all directions from 40 cm to 100 cm from the central X-ray, and about 88% of the space dose was reduced when using the developed shields with the phantom. The equidistance dose at 80 cm from the central X-ray was increased by 39% from $5.1{\pm}0.26{\mu}Gy$ to $7.1{\pm}0.15{\mu}Gy$ when the human equivalent phantom was used, and when phantom was used and shielding was used, the spatial dose was reduced by about 90% from $7.1{\pm}0.15{\mu}Gy$ to $0.7{\pm}0.07{\mu}Gy$. The spatial dose of natural radiation was measured to be about $0.2{\pm}0.04{\mu}Gy$ when using the developed shielding with Phantom at a distance of 1 m or more. It is expected that by using the developed shielding system, it will be possible to effectively reduce secondary radiation dose received in all directions and to ensure safe imaging.

흉부촬영(胸部撮影)에 있어 환자자세(患者姿勢)에 관(關)한 영향(影響) (Roentgenological Evaluation of Radiographic position of the Chest)

  • 신귀순;김영환;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제2권1호
    • /
    • pp.59-69
    • /
    • 1979
  • For the clearer visualization of the lung apices in the routine chest P-A view, we have analysed the films at the different positions and different directions of the central X-ray beams. The brief results are as the follows. 1. Best visualization of the lung apices are made with the following position of the patient and central ray. Central ray is directed to the median sagittal plane at the level of the 5th thoracic vertebra with the palms of the hands placing at the greater trochanteric area of the both femurs. 2. The position of the sterno-clavicular joint shows no alteration between the radiographs with the central beam to the film center and to the 5th thoracic vertebra, and position of the hands at the greater trochanters or iliac crests. 3. No relationship exists between the center of the film and the position of the hand. The central beam is projected more inferiorly when the beam is centered to the film center than to the 5th thoracic vertebra. 4. The scapulae are rotated sufficiently anteriorly and more inferiorly, with placing the palms at the greater trochanters, directing central ray to the 5th thoracic vertebra, and with close contact the lung apices to the cassette.

  • PDF

국내 X-선 촬영술에 있어서 실패의 원인분석에 관한 연구 (THE STUDY OF TECHNICAL FAILURE OF INTRAORAL ROENTGENOGRAPHY)

  • 강용상
    • 치과방사선
    • /
    • 제7권1호
    • /
    • pp.27-30
    • /
    • 1977
  • To insure accuracy in dental roentgenographs, it is important that the patient's head position and angulation of the x-ray tube. In 1907 Cieszynski applied the rule of isometry to dental radiography and established that in the production of an accurate image of a tooth, the central ray must be porjected perpendicularly to a plane bisecting angle formed by the longitudinal axis of the tooth and the film plane. Proper exposure of the film is a part of the production of a good dental radiograph, and correct processing also makes an essential contribution to the quality of the radiograph. The author analysed the failure of exposure and processing results, and recommended followings. 1. The patient head must be positioned that occlusal plane are parallel with the horizontal floor. 2. Central ray must be projected to the objective tooth and supporting structure and projected as perpendicularly to tooth axis and film surface as possible. 3. In processing, the temperature of the solution and the processing time must be correct.

  • PDF

X-ray micro-CT 이미지 내 패임 및 동심원상 화상결함 제거를 위한 이미지 보정 기법 (Image Calibration Techniques for Removing Cupping and Ring Artifacts in X-ray Micro-CT Images)

  • 정연종;윤태섭;김광염;주진현
    • 한국지반공학회논문집
    • /
    • 제27권11호
    • /
    • pp.93-101
    • /
    • 2011
  • X-ray micro-CT를 이용한 지반재료 내부 미세구조 및 공극구조의 정밀한 이미지 처리는 종종 이미지 내에 원천적으로 포함되는 화상결함으로 인해 제약된다. 본 논문에서는 X-ray micro-CT 이미지에 가장 일반적으로 나타나는 화상결함인 패임(영상 외곽과 중심부의 명암 차이) 및 동심원상(영상 중심으로부터 방사방향으로 연속적으로 나타나는 원)을 제거할 수 있는 이미지 보정 기법을 제시한다. 결함 제거는 좌표 변환법, 정규화 및 2차원 푸리에 변환에 의한 저역 통과 필터링 기법의 순차적 적용을 통해 이루어진다. 이미지 처리 기법의 효과를 다공성 현무암의 CT 이미지에서 화상결함들을 제거하고 이진화 후 적층하여 3차원 공극 구조를 추출하는 과정을 통해 설명하였다. 패임 및 동심원상 결함을 제거한 이미지와 원본 이미지의 비교 결과 결함 제거는 대상 재료 공극률의 과대평가를 방지할 수 있으며, 따라서 화상결함의 적절한 보정은 X-ray CT의 지반재료 적용 시 필수적인 과정으로 판단된다.