A Study on NOx Removal Efficiency using SNCR Process in the Industrial Waste Incineration Plant (산업폐기물 소각로에서 SNCR공정에 의한 NOx 제거효율에 관한 연구)

  • Ryu Hae-Yeol;Kim Min-Choul;Jung Jong-Hyeon;Lee Gang-Woo;Chung Jin-Do
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.4 s.85
    • /
    • pp.332-339
    • /
    • 2005
  • The environmental regulations in the world has been reinforced and many nations has devoted themselves to the development of cost-effective technology. Selective catalyst reduction(SCR) and selective non-catalyst reduction (SNCR) processes are mainly used to treat nitrogen oxidants generated from fossil-fuel combustion. One of these typical technologies for reduction of do-NOx is SNCR process has increased continuously because of the low cost for building and maintenance. Nevertheless the researches on the application to real scale plant by the reductant like Urea are rarely studied. In this paper, an experimental investigations were performed on the SNCR process in the industrial waste incineration plant. With no reducing agent, the concentration of NOx stayed in around 180 ppm $(O_2\;12\%)$ with the exhausting temperature of $950^{\circ}C$ and changed within the range of 20 ppm to remain relatively consistent. When $10\;wt\%)$ of a solution was added, the efficiency of denitrification reached above $61.4\%$ with the NSR of 2.0 and the exhausting temperature of $950^{\circ}C.$ When the concentration of the urea solution was set to $10\;wt\%$ and the sprinkling to four nozzles, the reaction temperature was reduced to about $50~100^{\circ}C$ with a mixture of $10\;wt\%\;CH_3OH\;and\;5wt\%\;Na_2CO_3$ in $40\;wt\%$ of the solution. The NOx removal efficiency increased to $78.4\%,$ achieving a broader and expansive range of reaction temperatures than the addition of an unmixed pure solution.

Post Occupancy Evaluation of the Central Hospital in Quang Nam Province of Vietnam Funded by Korean ODA (ODA 지원 베트남 중부 꽝남성 종합병원의 거주후 평가)

  • Kwon, Soon Jung;Yu, Yeo Kyoung;Kim, Jihyun;Bang, Seol Ah
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.22 no.1
    • /
    • pp.39-49
    • /
    • 2016
  • Purpose: This is the ex-post evaluation on "the Central General Hospital in Quang Nam Province in Vietnam" funded by Korean ODA. Through this evaluation, this study tries to explore useful ways to improve the effectiveness of Korean ODA projects related to hospital establishment. Methods: Field survey and analysis of questionaire to the staffs and patients of Quang Nam Province General Hospital were conducted twice in 2012 and 2014 after the completion of the Hospital. Two sets of surveys and questionaire outcomes have been comparatively analysed by statistics in order to seek the trend of satisfaction level of hospital users and find out the improvement way in hospital design and construction. Results: The satisfaction level on the hospital was relatively high and that of 2014 is higher than that of 2012. The satisfaction level of the users was recorded in Likert 5 scales. Continuous facility complement and maintenance is considered as the main contributor in increasing the satisfaction level of users. As far as the satisfaction level of outpatient is concerned, that of 2012 was recorded as 3.65 and that of 2014 was 4.05. In case of inpatient, the satisfaction level on the hospital in 2012 was 3.76, and 4.06 in 2014. Implications: In overseas hospital projects, proper hospital project management system including medical service plan, strategic plan, brief, design & construction and maintenance have to be put together effectively and efficiently for the success of the hospital project. At the same time local climate, culture, building material and local code have to be considered in order to build sustainable hospital.

Studies on the Analysis of Super Graphic Image and Preference -with Visual Design Element- (슈퍼 그래픽의 이미지와 선호성 분석에 관한 연구 -시각디자인 요 소를 중심으로-)

  • 나성숙
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.20 no.4
    • /
    • pp.54-75
    • /
    • 1993
  • The purpose of this thesis is to suggest objective basic data for the super graphics in the urban landscape through the quantitative visual quality analysis. For this, the image structure of super graphics have been measured mainly by questionnaries and semantic differential scle method and analyzed by the method of factor analysis, means and multiple regression. Degree of visual preference have been measured mainly by questionnaries and likert attitude scale method and finaly these data have been analyzed by using the stepwise method. The data were collected by presenting 12 super graphics photographs-4 each sample pictures from the 3 each selected districts representing typical urban landscape style(central business district, shopping district, apartment complex). Observer groups were categorized as professionals, students, the others. Result of this thesis can be summarized as fallows: 1. From all 12(3${\times}$4) sample super graphics, the value of each semantic differential scale among the observer groups were presented significant group difference. But no significant difference of the S.D. scale value were observed among central business district, shopping district and apartment complex super graphics. 2. For all experimental points, 4 types of factor have been observed. Factors covering the image of super graphics were found to be the evaluation, the intimacy, the potentiality and the tidiness. 3. Main factors of the super graphics image and factors indicating the group variations yielded high significance between areas. 4. The harmony with surrounding environment, the proper selection of super graphics subject yielded high values for all groups. Especially, the good color sense with building was the most important variable determining the degree of visual preference. 5. The urban C.B.D. super graphics obtained 5∼12 ranks of regional visual preference and the shopping district super graphics obtained 2∼11 ranks, and apartment complex super graphics obtained 1∼7 ranks.

  • PDF

Clinical Characteristics of Disability in Patients with Indoor Aire-Related Environmental Intolerance

  • Vuokko, Aki;Karvala, Kirsi;Suojalehto, Hille;Lindholm, Harri;Selinheimo, Sanna;Heinonen-Guzejev, Marja;Leppamaki, Sami;Cederstrom, Sebastian;Hublin, Christer;Tuisku, Katinka;Sainio, Markku
    • Safety and Health at Work
    • /
    • v.10 no.3
    • /
    • pp.362-369
    • /
    • 2019
  • Background: Chronic nonspecific symptoms attributed to indoor nonindustrial work environments are common and may cause disability, but the medical nature of this disability is unclear. The aim was to medically characterize the disability manifested by chronic, recurrent symptoms and restrictions to work participation attributed to low-level indoor pollutants at workplace and whether the condition shares features with idiopathic environmental intolerance. Methods: We investigated 12 patients with indoor aire-related work disability. The examinations included somatic, psychological, and psychiatric evaluations as well as investigations of the autonomic nervous system, cortisol measurements, lung function, and allergy tests. We evaluated well-being, health, disability, insomnia, pain, anxiety, depression, and burnout via questionnaires. Results: The mean symptom history was 10.5 years; for disabling symptoms, 2.7 years. Eleven patients reported reactions triggered mainly by indoor molds, one by fragrances only. Ten reported sensitivity to odorous chemicals, and three, electric devices. Nearly all had co-occurrent somatic and psychiatric diagnoses and signs of pain, insomnia, burnout, and/or elevated sympathetic responses. Avoiding certain environments had led to restrictions in several life areas. On self-assessment scales, disability showed higher severity and anxiety showed lower severity than in physician assessments. Conclusion: No medical cause was found to explain the disability. Findings support that the condition is a form of idiopathic environmental intolerance and belongs to functional somatic syndromes. Instead of endless avoidance, rehabilitation approaches of functional somatic syndromes are applicable.

Assessment of the Historical Variability of Meteorological Drought in Bangladesh (방글라데시의 기상학적 가뭄 변동성 평가)

  • Kamruzzaman, Mohammad;Hwang, Syewoon;Cho, Jaepil;Jang, Min-Won
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.3
    • /
    • pp.77-88
    • /
    • 2019
  • Drought is the recurrent natural disasters which harshly affect agricultural production and society in various parts in Bangladesh. Information on the spatiotemporal variability of drought events plays a vital role to take necessary action towards drought mitigation and sustainable development. This study aims to analyze the spatial and temporal variation of meteorological drought in Bangladesh during 1981-2015 using Effective Drought Index (EDI). Monthly precipitation data for 36 years (1980-2015) were obtained from 27 meteorological stations. Drought frequency (DF) and areal extent of drought were considered to investigate the spatiotemporal structure of drought. The DF analysis showed that the northern, southwestern and central regions of the country are comparatively vulnerable to meteorological drought. The frequency of drought in all categories has considerably increased during the recent five years from 2011 to 2015. Furthermore, the most significant increasing trend of the drought-affected area was found over the central region especially for pre-monsoon (March-May) season during this period while the decreasing trend of the affected area was found within the eastern region during the study period. To prevent and mitigate the damages of drought disasters in Bangladesh, agricultural and government managers should pay more attention to those regional drought events that occur in pre-monsoon season. The outcome of the present study can be used as explanatory data in building the strategies to drought monitoring and mitigation activities in Bangladesh.

A Study on the Chimi of Hwangnyongsa Temple and the Building Condition of Chimi Installed (황룡사 치미와 사용처의 건축조건 연구)

  • Kim, Sookyung
    • Journal of architectural history
    • /
    • v.31 no.6
    • /
    • pp.59-68
    • /
    • 2022
  • This paper is an architectural historical study on Chimi of Hwangnyongsa Temple. In this research, the shape and cross-section of the chimi are reviewed. The results of the study are as follows. The chimi is a form in which the head part facing the maru is omitted, and the upper and lower body are separated. The upper and lower bonds are assembled into a two types of joint throughout the side of the torso, and then bound with an iron strap. Because of the absence of ridge line in the front, and the narrow curved surface which makes the side plate close to the plane, the entire cross-section is triangular, and the rear plate maintains the shape of the chimi. The naerimmaru connected to the side of the chimi has a slope, so it is clear that the chimi was used on the woojingak-jibung(hipped-roof), and the wing part and back of the chimi are erected on the side roof. The height of the yongmaru and chunyeomaru is about the same and the roofing tiles of those are in contact. The roofing tiles of chunyemaru should be cut to fit the angle of the contacting part. The maru is 30 stories high of roofing tiles as a result of the on-board survey. Based on reference on the shape and timing of the production of chimi, the height of chimi, and the maru is believed to have been built before the Unified Silla Period and used in buildings with at least seven-kan frontage. Buildings corresponding to these construction conditions can be seen as Central hall and East hall in Hwangnyongsa temple.

Planning Method of Roof Framing through Inner Building of Changgyeonggung in 19th Century (19세기 창경궁(昌慶宮) 내전(內殿) 전각(殿閣)의 지붕가구(架構) 계획기법(計劃技法)에 관한 연구(硏究))

  • Kim, Ki Deoka;Han, Wook;Kim, Derk Moon
    • Korean Journal of Heritage: History & Science
    • /
    • v.42 no.2
    • /
    • pp.134-153
    • /
    • 2009
  • This study is to examine closely the frame structure of buildings in the royal palace of Josen dynasty, focused on inner buildings of Changgyeonggung(昌慶宮) which is built in 19th century, through considering the member size of main structure and analyzing the slope of a rafter. The plans of a size on main member are as follows ; firstly, a length of the perimeter column was accorded with Gunggwolji(宮闕誌) and the planning size of interior column was shown to a Chon(a Korean inch, 寸) unit. The slope of long common rafter that is formed between the perimeter and interior columns was grasped with limits of a definite value. This is that the perimeter column is trimmed to a Chon unit, as Yeongchunheon(迎春軒), In the roof frame of Korean traditional timber architecture, the slope of rafter, first of all, is to decide the slope of long common rafter and then to decide a height of ridge piece settled whole height of a building. And it is regulated with position and height of a post so as to set up middle rafter. Especially, the slope of long common rafter, it is not to be decide through scale of a building but through a length of the perimeter column and composition of bracket structure. And in case middle rafter, the process of its slope is to devide the central bay on the side of a building into equality, and then to adjust position and length of a post.

Cluster exploration of water pipe leak and complaints surveillance using a spatio-temporal statistical analysis (스캔통계량 분석을 통한 상수도 누수 및 수질 민원 발생 클러스터 탐색)

  • Juwon Lee;Eunju Kim;Sookhyun Nam;Tae-Mun Hwang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.5
    • /
    • pp.261-269
    • /
    • 2023
  • In light of recent social concerns related to issues such as water supply pipe deterioration leading to problems like leaks and degraded water quality, the significance of maintenance efforts to enhance water source quality and ensure a stable water supply has grown substantially. In this study, scan statistic was applied to analyze water quality complaints and water leakage accidents from 2015 to 2021 to present a reasonable method to identify areas requiring improvement in water management. SaTScan, a spatio-temporal statistical analysis program, and ArcGIS were used for spatial information analysis, and clusters with high relative risk (RR) were determined using the maximum log-likelihood ratio, relative risk, and Monte Carlo hypothesis test for I city, the target area. Specifically, in the case of water quality complaints, the analysis results were compared by distinguishing cases occurring before and after the onset of "red water." The period between 2015 and 2019 revealed that preceding the occurrence of red water, the leak cluster at location L2 posed a significantly higher risk (RR: 2.45) than other regions. As for water quality complaints, cluster C2 exhibited a notably elevated RR (RR: 2.21) and appeared concentrated in areas D and S, respectively. On the other hand, post-red water incidents of water quality complaints were predominantly concentrated in area S. The analysis found that the locations of complaint clusters were similar to those of red water incidents. Of these, cluster C7 exhibited a substantial RR of 4.58, signifying more than a twofold increase compared to pre-incident levels. A kernel density map analysis was performed using GIS to identify priority areas for waterworks management based on the central location of clusters and complaint cluster RR data.

The Evaluation of Regional Innovation and Innovative Cluster Policies in Korea (참여정부 지역혁신 및 혁신클러스터 정책 추진의 평가와 과제)

  • Lee, Chul-Woo
    • Journal of the Economic Geographical Society of Korea
    • /
    • v.10 no.4
    • /
    • pp.377-393
    • /
    • 2007
  • National balanced development and regional innovation have been one of the most important national agendas under the Participatory Government. National balanced development gives a central focus on realizing self-sustaining localization which is based on regional innovation. The core policy goal is to build competitive regional innovation system and innovative clusters in the regions of the country. In this vein, this paper aims to evaluate the present government's policies of regional innovation and innovative cluster. It needs to point out that the regional innovation and cluster policies show some critical problems. Firstly, the policy-making process is based on the top-down approach rather than the bottom-up one. Secondly, regional innovation policies, in many cases, expose the redundancy of similar policies and a lack of linkages between similar policies. Thirdly, the regional innovation policies are too much social infrastructure building-centered, even though the basic principle of regional innovation policy should be based on building superstructure such as networking and social capital.

  • PDF

Development of a Joint University Campus as a Key Element in the Regional Innovation System in Sejong Tech Valley, South Korea

  • Lee, Seo-Jeong;Lee, Eung-Hyun;Oh, Deog-Seong
    • World Technopolis Review
    • /
    • v.6 no.2
    • /
    • pp.148-158
    • /
    • 2017
  • Sejong City, which has been chosen as a new administrative capital of South Korea, has completed the first phase of its development plan with the construction of the facilities needed to accommodate central administrative organizations and the required accompanying population. Now, it is undergoing the second phase of development with a focus on strengthening the region's innovation capacity to catalyze endogenous development. The strategy for phase II is to establish a regional innovation system including building necessary infrastructure and attracting innovation agents such as universities, businesses, and research institutes. The first step for this is developing a research complex, tentatively named Tech Valley, that includes universities, research institutes, and businesses, and building infrastructure comprising a science complex, a knowledge industry center, and support facilities. Phase II of the city's development initiative includes the establishment of a joint university campus, which is to serve as a center to promote cooperation among industry actors, universities, and research institutes. The concept of a joint campus has been drawn from a need to enhance capacity for innovation and specialization in the region's industries and to maximize synergy among participating universities through the sharing of research equipment, facilities, and programs. The joint campus is expected to play a key role in creating an innovation system in the region by enhancing research capacity for strategic industries, cultivating highly skilled human resources, and leading industry-academia-research cooperation. In order to ensure the sustainable development of the new city, there is a growing need to have a main player in place that could lead the region's economic development. The joint campus will propel industrial specialization and serve as a catalyst to attract competent universities to the region. This paper will examine the concept, major functions, and the establishment and operation of the joint campus.