• Title/Summary/Keyword: Center sampling

Search Result 1,207, Processing Time 0.023 seconds

A Robot End-effector for Biopsy Procedure Automation with Spring-Triggered Biopsy Gun Mechanism (스프링 격발형 생검총 구조를 가진 생검 시술 자동화 로봇 말단장치)

  • Won, Jong-Seok;Moon, Youngjin;Park, Sang Hoon;Choi, Jaesoon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.8
    • /
    • pp.590-596
    • /
    • 2016
  • Biopsy is a typical needle type intervention procedure performed under radiographic image equipment such as computed tomography (CT) and cone-beam CT. This minimal invasive procedure is a simple and effective way for identifying cancerous condition of a suspicious tissue but radiation exposure for the patients and interventional radiologists is a critical problem. In order to overcome such trouble and improve accuracy in targeting of the needle, there have been various attempts using robot technology. Those devices and systems, however, are not for full procedure automation in biopsy without consideration for tissue sampling task. A robotic end-effector of a master-slave tele-operated needle type intervention robot system has been proposed to perform entire biopsy procedure by the authors. However, motorized sampling adopted in the device has different cutting speed from that of biopsy guns used in the conventional way. This paper presents the design of a novel robotic mechanism and protocol for the automation of biopsy procedure using spring-triggered biopsy gun mechanism. An experimental prototype has been successfully fabricated and shown its feasibility of the automated biopsy sequence.

20 GHz Pulse Sampling Oscilloscope Based on Electro-Optic Technique (광-전자파 기반 20 GHz급 펄스 샘플링 오실로스코프)

  • Lee, Dong-Joon;Kang, No-Weon;Lee, Joo-Gwang;Kang, Tae-Weon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.10
    • /
    • pp.927-933
    • /
    • 2011
  • This paper presents an optical sampling technique which can be used to overcome the limited bandwidth of a commercial electronic sampling oscilloscope for pulsed signal measurement. Employing an ultrafast laser with 0.1 ps pulse duration, 20 GHz electromagnetic pulses were generated through a fast photodiode. These pulses were transmitted through a microstrip line and sampled with an optically triggered electro-optic system. Two sampled 20 GHz pulses - measured independently over the transmission line with a non-contacting electro-optic method and conventional electronic one through a coaxial cable - were compared.

Performance Evaluation of Synchronization Method for Reducing the Overall Synchronization Time in Digital Radio Mondiale Receivers

  • Kwon, Ki-Won;Kim, Seong-Jun;Hwang, Jun;Paik, Jong-Ho
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.7 no.8
    • /
    • pp.1860-1875
    • /
    • 2013
  • In this paper, we present a comparative performance evaluation of the sampling frequency synchronization method that eliminates the initial sampling frequency offset (SFO) to reduce the overall synchronization time in Digital Radio Mondiale (DRM) receivers. To satisfy the advanced synchronization performance requirements of DRM receivers, we introduce the conventional DRM synchronization method (Method 1) and another method (Method 2), which does not perform the initial sampling frequency synchronization in the conventional synchronization method (both methods are mentioned later in this paper). To demonstrate the effectiveness of the performance evaluation, analytical expressions for frame detection are derived and simulations are provided. Based on the simulations and numerical analysis, our result shows that Method 2, with a negligible performance loss, is robust to the effects of the initial sampling frequency synchronization even if SFO is present in the DRM signal. In addition, we verify that the inter-cell differential correlation used between reference cells is robust to the effect of the initial SFO.

A RESERCH ON THE BASIS OF QUESTIONNAIRES ABOUT COMMON PEOPLE'S UNDERSTANDING OF THE DENTAL IMPLANT (치과 임프란트에 대한 일반인의 인식도에 관한 설문조사 연구)

  • Kim, Hyun-Woo;Park, Sang-Soo;Kim, Woo-Taek;Cho, Nam-Sung;Park, Yang-Ho;Park, Jun-Woo;Rhee, Gun-Joo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.4
    • /
    • pp.353-357
    • /
    • 2001
  • The techniques of the dental treatment are well known to common people, but the dental implant as one of the treatment options to rehabilitate patient's mouth is little known to them. Taking these situation into consideration, we, writers made actual analyses of statistics by putting into the form of diagrams based on questionnaires. Three hundreds of common people over 20 years old were picked up and we used convenience sampling method which is one of nonprobability sampling methods. Statistics are about these questions. 1. How much common people know about dental implant as a treatment option. 2. How much common people know about the detailed portions of the dental implant for rehabilitaton. 3. How common people got to know the dental implant. We present actual answers of the common people.

  • PDF

The Study of Critical Indicators Development for Establishing Patient Classification System in the ER (응급실의 환자분류체계 확립을 위한 결정지표 개발 연구)

  • Seong, Young-Hee;Seong, Il-Sun;Lee, Seung-Ja;Kim, Jeong-Ha;Moon, Yu-Jeong;Choe, Yeong-Mi;Lee, Jee-Hyang
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.12 no.3
    • /
    • pp.444-453
    • /
    • 2006
  • Purpose: The purpose of the study was to identify critical indicators for the development of efficient patient classification system in a emergency room. Method: This study involved following five steps. Step 1. Selection of the lists direct nursing services in the ER. Step 2. Measurement of the time of direct nursing services from Aug. 31st to Nov. 30th, 2005. Step 3. Classification of the patients according to the nursing care time. Step 4. The determination the critical indicators for different patient classes. Result: Determinate indicators were as follow: 3 items in the first group (vital sign checking, IV route starting, blood sampling), 3 items in the second group (vital sign checking, fluid infusion, blood sampling), 9 items in the third group (I/O checking, $O_{2}$ inhalation, suction, fluid infusion, IV bolus, Central catheter preparation & management, blood sampling, intubation preparation & management, postmortem management), 7 items in the fourth group (EKG monitoring, BP monitoring, $O_{2}$ inhalation, fluid infusion, using the specific drugs, CPR, postmortem management). Conclusion: This study can help future studies which measure nursing services standard time or assigns value to emergency nursing services.

  • PDF

Calibration and Uncertainty Analysis of Sample-Time Error on High Jitter of Samplers

  • Cho, Chihyun;Lee, Joo-Gwang;Kang, Tae-Weon;Kang, No-Weon
    • Journal of electromagnetic engineering and science
    • /
    • v.18 no.3
    • /
    • pp.169-174
    • /
    • 2018
  • In this paper, we propose an estimation method using multiple in-phase and quadrature (IQ) signals of different frequencies to evaluate the sample-time errors in the sampling oscilloscope. The estimator is implemented by ODRPACK, and a novel iteration scheme is applied to achieve fast convergence without any prior information. Monte-Carlo simulation is conducted to confirm the proposed method. It clearly shows that the multiple IQ approach achieves more accurate results compared to the conventional method. Finally, the criteria for the frequency selection and the signal capture time are investigated.

A PWM Method for Single-Phase 3-Level High Power Rectifiers (단상 3레벨 대용량 정류기의 PWM방법)

  • Cho, S.J.;Song, J.H.;Kim, Y.D.;Choy, I;Yoo, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.1937-1939
    • /
    • 1998
  • This paper presents a simple switching method to generate a PWM pattern mostly relevant to signle-phase three-level PWM rectifier. The adopted PWM switching pattern is performed in a manner similar to the space vector PWM method, which is popularly used in the three-phase rectifier and inverter. A set of possible voltages has been selected so that an equation with a time integral considered within a sampling period should be satisfied every sampling time. The simulation result shows that the proposed control scheme is good in some performance criteria such as unity power factor, low harmonic distortion of input current, dynamic response and voltage balancing of two series-connected DC capacitors.

  • PDF

Evaluation of Badge-Type Diffusive Sampler Performance for Measuring Indoor Formaldehyde

  • Yim, Bongbeen;Lee, Kyusung;Kim, Jooin;Hong, Hyunsu;Kim, Suntae
    • Environmental Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.123-128
    • /
    • 2013
  • The purposes of this study were to determine the efficiency of using a badge-type diffusive sampler to measure formaldehyde concentrations indoors, and to evaluate the uncertainty associated with the use of data from a diffusive sampler. A diffusive sampler using 2,4-dinitrophenylhydrazine (DNPH) reagent was found to be a suitable tool for measuring the formaldehyde concentration in an indoor environment. The agreement between results of the diffusive sampler and DNPH cartridge were good, showing a correlation coefficient of 0.996. The sampling rate for the diffusive sampler was calculated to be 1.428 L $hr^{-1}$, with a standard deviation of 0.084 L $hr^{-1}$. It was found through analysis that the uncertainty associated with the sampling rate and the mass of the formaldehyde transported into the diffusive sampler by diffusion was the dominant contributor to the total.

Does Different Performance of Sampling Gears (Cast Net versus Gill Net) Bring the Inappropriate Estimation of Freshwater Fish in a Large River?

  • Kim, Jeong-Hui;Park, Sang-Hyeon;Baek, Seung-Ho;Jang, Min-Ho;Lee, Hae-Jin;Yoon, Ju-Duk
    • Korean Journal of Ecology and Environment
    • /
    • v.53 no.2
    • /
    • pp.156-164
    • /
    • 2020
  • The accurate estimation of fish assemblages is highly dependent on the sampling gear used for sampling. We used data from 15 sampling sites along the Nakdong River, which is a large river in South Korea, to identify differences in assemblages and sizes of freshwater fishes collected with either cast nets or gill nets, the two most commonly used sampling gear in South Korea. The two gears differed in the fish assemblages they captured, with more species caught by gill nets. Further, due to its tighter mesh size, the cast net caught significantly smaller fishes than the gill nets(independent t-test, p<0.05). We found the cast net to be appropriate for species that inhabit shallow (less than 2 m) and open water, but inappropriate for deep water, habitats with plant beds, and nocturnal species. Thus, cast net sampling is not efficient in a large river environment, and a combination of sampling methods is more suitable for understanding fish assemblages in such habitats. In general, appropriate selection of fishing methods to specific habitats is necessary to improve data quality and minimize the misrepresentation of environmental conditions.