• Title/Summary/Keyword: Center position

Search Result 3,366, Processing Time 0.041 seconds

Variations of swirl center according to evaluation position in steady flow bench of SI engine

  • Lee, Sukjong;Sung, Jaeyong;Ohm, In Yong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.10
    • /
    • pp.1263-1268
    • /
    • 2014
  • In this study, the variations of swirl center according to evaluating position have been investigated in a steady flow bench of SI engine. For the experiments, two engine heads with different intake valve angles ($11^{\circ}$ and $26^{\circ}$) were tested in the flow bench by varying the evaluating position (1.75~6.0B) and valve lift (2~10 mm). Particle image velocimetry was used to measure the velocity field inside the engine cylinder. The swirl center position is found with a critical point theory and the intensity of turbulence is calculated from PIV velocity data. The results show that the center of swirl is located closer to the center of cylinder and turbulence intensity is lower, when the intake valve angle is the smaller. It is conventional to evaluate the swirl ratio at 1.75B position in the steady flow bench of SI engine. At this position, however, the distance of swirl center from the cylinder center scatters significantly for the variation of valve lift, and the turbulence intensity is much stronger regardless of the valve angle. Thus, to estimate the flow at the end of compression stroke in a real engine from the data in the steady flow experiments, the evaluation position should be moved further downstream more than 4.5B.

Quality Assurance System for Determination of Center Position in X-ray and Proton Irradiation Fields using a Stainless Ball and Imaging Plates in Proton Therapy at PMRC

  • Yasuoka, Kiyoshi;Ishikawa, Satoko
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.189-191
    • /
    • 2002
  • In the proton therapy using a gantry system, periodical verification of iso-center position is very important to assure precision of patient positioning system at any gantry angles in proton treatment. In the gantry system, there are three different types of iso-center; 1) in a geometrical view, 2) in an X-ray beam's eye view, 3) in a proton beam's eye view. Idealistically, they would be an identical point. They could, however, be different points. It may be a source of errors in patient positioning. At PMRC, we have established a system of verification for iso-center positions using a stainless ball of 2-cm in diameter and an imaging plate. This system provides the relation among a center of a patient target position, a center of proton irradiation field, and/or a center of X-ray field in accuracy of 50$\square$m in the 2) and 3) views, as images of a center of the stainless ball and a center of a 100 mm${\times}$100 mm-aperture brass collimator recorded on the imaging plate, which is setup at 1-cm behind the ball. In addition, it provides simultaneously the images of the ball and the collimator on an imaging intensifier (II), which is setup downstream of the proton or X-ray beam. We present a method of quality assurance (QA) for calibration of iso-center position in a rotation gantry system at PMRC and the performance of this system. A proton beam position on the 1$\^$st/ scatterer in the nozzle of the gantry affects less sensitive (reduced by a factor of 1/5) to the results of the iso-center position. The effect is systematically correctable. The effect of the nozzle (or the collimator) position is less than 0.5 mm at the maximum extraction (390 mm).

  • PDF

Development of center position control system for travelling machines using image processing (영상인식을 이용한 이동기기 정 중심확인 시스템 개발)

  • 최일섭;전종학
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1484-1487
    • /
    • 1996
  • An Automatic coking control system was developed to achieved substantial energy and labor savings through the stabilization and optimization of coke oven operation. With the aim of saving energy and labor, the coke department has been advanced automation and systematization. A typical examples of automation is Center Position Control System(CPCS) for coke oven. This system is proved effective in improvement of center position accuracy.

  • PDF

Ground-Platform Sensor Position Optimization Based Hybrid Time Difference of Arrival Method for Airborne Emitter (Hybrid TDOA 알고리즘 기반의 Airborne Emitter 위치탐지를 위한 Ground-Platform 센서의 위치 최적화)

  • Park, Jin-Oh;Lee, Woo-Seok;You, Byung-Sek;Kook, Chan-Ho;Chung, Jae-Woo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.886-893
    • /
    • 2010
  • This paper considers the problem of time difference-of-arrival(TDOA) source localization when the TDOA and angle of arrival(AOA) measurements from an airborne emitter source are subject to ground-platform sensor position. The optimization of sensors' position is a challenging problem and a solution with good localization accuracy has yet to be found. This paper proposes an estimator that can achieve these purposes and provides optimized sensor position for good localization accuracy using the proposed estimator. The developed algorithm and sensor position are then examined under the special case of a single airborne source. The theoretical developments are supported by simulations.

Changes in Orthostatic Hypotension According to the Levels of Head-up Position during Sleep in Patients with Parkinsonian Disorders (파킨슨증 환자에서 수면 시 두부거상 정도에 따른 기립성 저혈압의 변화)

  • Kim, Sung Reul;Chae, Hyun Sook;Yoon, Mi Jung;Park, Su Young;Jung, Da Hee;Lee, Hyang Hee;Chung, Sun Ju;An, Young Hee;Kim, Kyoung Ok
    • Journal of Korean Clinical Nursing Research
    • /
    • v.17 no.2
    • /
    • pp.275-285
    • /
    • 2011
  • Purpose: Head-up position during sleep is one of the non-pharmacologic interventions for the treatment of orthostatic hypotension. Because the head-up position causes discomfort in many patients, this approach may not be acceptable to all patients. We compared the systolic blood pressure in erect position, orthostatic hypotension, orthostatic disability score, and the improvement rates of orthostatic hypotension between the 20 cm head-up group and the 10 cm head-up group. Methods: A control pre/post-test design was used. Between August 1, 2009 and November 15, 2010, we consecutively enrolled patients who showed orthostatic hypotension in patients with Parkinsonian disorders. Sixty-seven patients were prospectively enrolled and forty-four patients were completed the study. Results: There were no statistically significant differences found in the systolic blood pressure in erect position, orthostatic hypotension, and orthostatic disability scores between the two groups. However, five patients showed improvement in 20 cm head-up group and one patient was showed improvement in 10 cm head-up Group. Conclusion: Orthostatic hypotension is decreased with 20 cm head-up position in some patients with Parkinsonian disorders (p=.034). Further research investigating the relationships between orthostatic hypotension and head-up position are warranted.

Web Guide Process in Cold Rolling Mill : Modeling and PID Controller

  • Ahn, Byoung-Joon;Park, Ju-Yong;Chang, Yu-Shin;Lee, Man-Hyung
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.7
    • /
    • pp.1074-1085
    • /
    • 2004
  • There are many intermediate web guides in cold rolling mills process such as CRM (cold rolling mill), CGL (continuous galvanizing line), EGL (electrical galvanizing line) and so on. The main functions of the web guides are to adjust the center line of the web (strip) to the center line of the steel process. So they are called CPC (center position control). Rapid process speed cause large deviation between the center position of the strip and the process line. Too much deviation is not desirable. So the difference between the center position of the strip and the process line should be compensated. In general, the center position control of the web is obtained by the hydraulic driver and electrical controller. In this paper, we propose modelling and several controller designs for web-guide systems. We model the web and guide by using geometrical relations of the guide ignored the mass and stiffness of the web. To control the systems, we propose PID controllers with their gains tuned by the Ziegler-Nichols method, the H$\_$$\infty$/ controller model-matching method, and the coefficient diagram method (CDM). CDM is modified for high order systems. The results are verified by computer simulations.

The Effects of PNF Patterns on Trunk Muscle Activity According to Position Changes (자세변화에 따른 PNF 패턴이 체간 근육활성에 미치는 영향)

  • Kim, Kyung-Hwan;Youn, Hye-Jin;Park, Sung-Hun;Lim, Jin-Woo
    • PNF and Movement
    • /
    • v.14 no.1
    • /
    • pp.1-6
    • /
    • 2016
  • Purpose: The purpose of this study was to analyze the effects of proprioceptive neuromuscular facilitation (PNF) patterns on electromyography (EMG) activity in the rectus abdominis, internal abdominal oblique, external abdominal oblique, and erector spinae according to position changes. Methods: Ten healthy adults volunteered to participate in the study. The subjects were required to complete exercises that followed two PNF extremity patterns, namely, an upper extremity extension-adduction-internal rotation pattern and a lower extremity flexion-adduction-external rotation pattern. The exercises were applied in the supine, side-lying, and sitting positions. Repeated measure one-way ANOVA and post-hoc Bonferroni correction were used to determine the influence of the patterns on muscle activity for each muscle, and descriptive statistics were then used to determine the local/global muscle ratios. Results: The upper extremity pattern had a significant effect on the rectus abdominis and erector spinae in the supine position, and on the internal oblique and external oblique in the sitting position (p<0.05). The median value for the internal oblique/rectus abdominis showed a high ratio of 2.05, and a high ratio of 1.01 was shown for the internal oblique/external oblique in the sitting position. The lower extremity pattern had a significant effect on the rectus abdominis in the side-lying position and on the internal oblique, external oblique, and erector spinae in the sitting position (p<0.05). The median value for the internal oblique/rectus abdominis showed a high ratio of 2.83 in the sitting position and a high ratio of 1.30 for the internal oblique/external oblique in the side-lying position. Conclusion: The PNF pattern increases local muscle activation in an unstable position. Therefore, when the pattern is used for intervention purposes, trunk stability and varied position changes should be taken into account.

Correlation between the Position of the Pituitary Stalk as Determined by Diffusion Tensor Imaging and Its Location as Determined at the Time of Surgical Resection of Pituitary Adenomas

  • Wang, Fu-yu;Wang, Peng;Yang, Chen-xuan;Zhou, Tao;Jiang, Jin-li;Meng, Xiang-hui
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.4
    • /
    • pp.504-512
    • /
    • 2020
  • Objective : An important factor during pituitary adenoma surgery is to preserve pituitary stalk (PS) as this plays a role in reduction of the risk of postoperative diabetes insipidus. The hypothalamic-hypophyseal tract (HHT) projects through the PS to the posterior pituitary gland. To reconstruct white matter fiber pathways, methods like diffusion tensor imaging (DTI) tractography have been widely used. In this report we attempted to predict the position of PS using DTI tractography and to assess its intraoperative correlation during surgery of pituitary adenomas. Methods : DTI tractography was used to tract the HHT in nine patients before craniotomy for pituitary adenomas. The DTI location of the HHT was compared with the PS position identified at the time of surgery. DTI fiber tracking was carried out in nine patients prior to the planned craniotomy for pituitary adenomas. In one patient, the PS could not be identified during the surgery. In the other eight patients, a comparison was made between the location of the HHT identified by DTI and the position of the PS visualized at the time of surgery. Results : The position of the HHT identified by DTI showed consistency with the intraoperative position of the PS in seven patients (88.9% concordance). Conclusion : This study shows that DTI can identify the position of the HHT and thus the position of the PS with a high degree of reliability.

Analysis of the 500M Short track speed skating starting motion according to the center of gravity position ratio (인체 무게 중심 분할에 따른 500m 숏트트랙 스피드 스케이팅 출발 기술 분석)

  • Back, Jin-Ho;Chung, Nam-Ju;Han, Ki-Hoon;Lee, Yong-Goo;Yoon, Dong-Seob;Lee, Yong-Sik
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.3
    • /
    • pp.199-215
    • /
    • 2003
  • The purpose of this study was to attempt new starting motion and supply present starting motion in the 500M short track speed skating according to the center of gravity position. The center of gravity position ratio was divided starting motion into five(type A : front 80%-back 20%, type B front 70%-back 30%, type C : front 50%-back 50%, type D : front 30%-back 70%, type E : front 20%-back 80%). The three dimension motion analysis with DLT(direct linear transformation) method was executed using two video cameras. The following conclusion was that It was appear that reaction and execution time in starting motion was the most short in type B. It was characteristic that step of skaters was shorten and center of gravity position ratio was not effect to change of the step in each event. It was appear that the displacement of type D and type E were longer than that type A and type B during the starting motion. It was appear that skill types of center of gravity position ratio to the front were lower than that to the back and contract a posture. Observing the above, it was conclusion that skill type B of center of gravity position ratio to the tent was more effect than that to the back. But it is important that these skill type was most used to the competition and estimate the result.

Analysis of the Female 500m Sprint Starting Motion in Short Track Speed Skating (여자 500m 쇼트트랙 스피드 스케이팅의 스타트 기술분석)

  • Back, Jin-Ho;Kwak, Chang-Soo;Chung, Nam-Ju
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.3
    • /
    • pp.285-299
    • /
    • 2004
  • The purpose of this study is to identify female 500m sprint start motion by the center of gravity position in short track speed skating. The center of gravity position ratio was divided into three type(type A front : 80%-back : 20%, type B front : 70%-back 30%, type C front: 50%-back : 50%). Three video cameras were used for 3D motion analysis with DLT method and the results were as follows: The elapsed time in starting motion was appeared that type B was the shortest and type A was the longest. It was appear that the stroke length of type A was longer than that type B and C during starting phase. This result was similar to displacement of center of gravity. It was appeared that skill type of center of gravity position ratio type B' ankle and knee joint angle were lower than that of type A and C. Observing these results it was conclusion that skill type B of center of gravity position ratio was more faster than that of type A and C. But it is important that these skill type needed to verifying more subjects.