• Title/Summary/Keyword: Center Loss

Search Result 3,752, Processing Time 0.031 seconds

Long-Term Outcome of Free Rectus Abdominis Musculocutaneous Flap for General Soft-Tissue Reconstruction

  • Park, Jungheum;Son, Daegu;Song, Joongwon
    • Archives of Reconstructive Microsurgery
    • /
    • v.24 no.1
    • /
    • pp.7-12
    • /
    • 2015
  • Purpose: The rectus abdominis musculocutaneous (RAM) flap has contributed to the efficient reconstruction of soft tissue defects. The flap has the advantage of easy dissection, minimal donor site morbidity, and the constant vascular anatomy with long pedicle. Authors used the free RAM flap to reconstruct multi-located soft tissue defects while still considering functionality and aesthetics. We present the long-term outcomes and versatility of free RAM flaps. Materials and Methods: From 1994 to 2004, all patients who underwent soft tissue reconstruction with free RAM flap were reviewed retrospectively. The site of the reconstruction, vessels of anastomosis, type of RAM flap, and outcomes, including flap success rate, hospital stay after flap transfer, conduction of secondary procedure, flap complications, and donor-site complications were analyzed. Results: Twenty-one patients underwent 24 free RAM flaps in site of breast, face, upper extremity and lower extremity. Mean follow-up period was 36.1 months (range, 3~156 months). The overall success rate was 92% with only a loss of 2 flaps. Minor complications related to transferred flaps were necrosis of 2 partial flaps, hematoma formation in 3 cases, and a wound infection in 1 case. Donor site morbidity was not observed. Debulking surgery was performed in 4 patients, and scar revision was performed in 3 patients. Conclusion: Free RAM flap is a workhorse flap for general soft-tissue reconstruction with minimal donor site morbidity with aesthetically good results. Thus, the free RAM flaps are versatile, and sturdy for any sites of soft-tissue where reconstruction could be performed.

Application of trajectory data mining to improve the estimation accuracy of launcher trajectory by telemetry ground system (원격자료수신장비의 발사체궤적 추정정확도 향상을 위한 궤적데이터마이닝의 적용)

  • Lee, Sunghee;Kim, Doo-gyung;Kim, Keun-hyung
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.20 no.5
    • /
    • pp.1-11
    • /
    • 2015
  • This paper is focused on how the trajectory of launch vehicle could be optimally estimated by the quadratic regression of trajectory data mining for the operation of telemetry ground system in NARO space center during real-time. To receive the telemetry data, the telemetry ground system has to track the space launch vehicle without tracking loss, and it is possible by the well-designed algorithm to estimate a flight position in real-time. For this reason, the quadratic regression model instead of interpolation was considered to estimate the exact position data of launch vehicle and the improvement of antenna performance. For analysis, the real trajectory data which had been logged during NARO 1st launch mission were used, the estimation result of launcher current position was analyzed by the mathematical modeling. In conclusion, the algorithm using quadratic regression based on trajectory data mining showed the better performance than previous interpolation algorithm to estimate the next flight position and the antenna driving performance.

A Case Report of MELAS syndrome Improved by Oriental Medicine Treatment (한방치료 후 호전된 MELAS 증후군 증례 1례)

  • Seong, Kee-Moon;Yu, Deok-Seon;Choi, Byoung-Sun;Heo, Rae-Kyong;Jang, Myung-Jun;Lee, In-Yung;Song, Bong-Keun
    • Herbal Formula Science
    • /
    • v.18 no.2
    • /
    • pp.267-277
    • /
    • 2010
  • Objective : Mitochondrial myopathy, encephalopathy, lactic acidosis, and stroke like episodes (MELAS) syndrome is a progressive neurodegenerative disorder. The typical presentation of patients with MELAS syndrome includes features such as mitochondrial encephalomyopathy, lactic acidosis, and stroke like episodes. Other features, such as seizures, diabetes mellitus, hearing loss, cardiac disease, short stature, endocrinopathies, exercise intolerance, and neuropsychiatric dysfunction are clearly part of the disorder. Approximately 80% of patients with the clinical characteristics of MELAS syndrome have a genetic mutation. This progressive disorder is reported to have a high morbidity and mortality. This case report is intended to estimate clinical effects of oriental meedicinal treatment of MELAS syndrome. Methods : A 44 year old female patient diagnosed as MELSA syndrome was treated with general oriental medicinal therapy including acupuncture, moxibustion, cupping, pharmacupunture and herbal medication in 20XX in Wonkwang Medical Center Gwangju. And the changes in symptoms and signs were evaluated as time dependently. Results : Although there is currently no curable treatment and MEALS syndrome is tend to progress, our treatment showed improvement in general weakness, gait disturbance and pain in the patient. Conclusion : Our case report suggests that various oriental medicinal treatment could be effective for improvement of MELAS syndrome and may represent a new potential therapeutic approach to control the disease. It could be applied to improve general condition, prevent relapse, enhance the quality of life and reduce complaints in the patient.

A NOVEL 3D SCAN METHOD TO QUANTIFY TEETH WEAR (3-Dimensional scan을 이용한 치아 마모량 측정 방법에 관한 연구)

  • Kim Seung-June;Choi Dae-Gyun;Kwon Kung-Rock;Lee Seok-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.1
    • /
    • pp.1-10
    • /
    • 2004
  • Statement of problem : Tooth wear is physiological phenomenon. Ninety-seven percent of normal people have tooth wear and about 7% has pathologic teeth wear. If we know the amount of tooth surface loss caused by pathologic tooth wear, we may restore it ideally Purpose : Recently measurement of tooth wear by using 3D scan has been increasing. Therefore, we need to know how accurate 3D scan is. Past accuracy test on 3D scan was about linear change, but as we know that tooth wear is volume change. Thus, the purpose of this study is to know how accurate 3D scan is. Material and Methods : For accuracy test of 3D scanner volume values measured by 3D scanner and micro-balance were compared. For test I, preliminary, 3 ball samples and 3 circular cones were made with pattern resin. For test II, 10 teeth shape rubber samples were used. Results and Conclusion : 1. The result of the accuracy test on 3D scan with 3 ball samples and 3 circular cones made of pattern resin has no significant difference(p<0.05). 2. The result of the accuracy test on 3D scan with 10 samples of tooth shape rubber has no significant difference (p<0.05). As a result, we may concluded the analysis of quantifying tooth wear used by 3D scan is useful in the clinic.

Risk indicators for mucositis and peri-implantitis: results from a practice-based cross-sectional study

  • Rinke, Sven;Nordlohne, Marc;Leha, Andreas;Renvert, Stefan;Schmalz, Gerhard;Ziebolz, Dirk
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.3
    • /
    • pp.183-196
    • /
    • 2020
  • Purpose: This practice-based cross-sectional study aimed to investigate whether common risk indicators for peri-implant diseases were associated with peri-implant mucositis and peri-implantitis in patients undergoing supportive implant therapy (SIT) at least 5 years after implant restoration. Methods: Patients exclusively restored with a single implant type were included. Probing pocket depth (PPD), bleeding on probing (BOP), suppuration, and radiographic bone loss (RBL) were assessed around implants. The case definitions were as follows: peri-implant mucositis: PPD ≥4 mm, BOP, no RBL; and peri-implantitis: PPD ≥5 mm, BOP, RBL ≥3.5 mm. Possible risk indicators were compared between patients with and without mucositis and peri-implantitis using the Fisher exact test and the Wilcoxon rank-sum test, as well as a multiple logistic regression model for variables showing significance (P<0.05). Results: Eighty-four patients with 169 implants (observational period: 5.8±0.86 years) were included. A patient-based prevalence of 52% for peri-implant mucositis and 18% for peri-implantitis was detected. The presence of 3 or more implants (odds ratio [OR], 4.43; 95 confidence interval [CI], 1.36-15.05; P=0.0136) was significantly associated with an increased risk for mucositis. Smoking was significantly associated with an increased risk for peri-implantitis (OR, 5.89; 95% CI, 1.27-24.58; P=0.0231), while the presence of keratinized mucosa around implants was associated with a lower risk for peri-implantitis (OR, 0.05; 95% CI, 0.01-0.25; P<0.001). Conclusions: The number of implants should be considered in strategies to prevent mucositis. Furthermore, smoking and the absence of keratinized mucosa were the strongest risk indicators for peri-implantitis in patients undergoing SIT in the present study.

Reconstruction of upper anterior by implant using customized zirconia abutment and all ceramics: a clinical report (맞춤형 지르코니아 지대주와 완전도재관을 이용한 상악 전치부 임플란트 보철 수복)

  • Kim, Ja-Yeong;Seo, Jae-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.1
    • /
    • pp.81-92
    • /
    • 2014
  • It is so hard to obtain optimal anterior esthetics in the implant prosthesis. This is not only because of hard and soft tissue problem such as alveolar bone resorption and interdental papilla loss but also because of prosthetic limitation related to marginal exposure of metal abutment and metal ceramics and low transillumination. In this case, guided soft tissue healing is obtained using a long term provisional restoration with soft and hard tissue augmentation or immediate implantation. Then, this healed tissue is transferred to final master model using a customized impression coping and the implant is restored with a customized zirconia abutment and a all ceramics. This case presents satisfying result esthetically and functionally.

A Phenomenological Approach on the Child-Rearing Experience of Mothers Who Adopted Disabled Children -In Case of Finding Disability after Adoption- (장애아동 입양어머니의 양육경험에 대한 현상학적 연구 -입양 후 장애가 드러난 경우-)

  • Kim, Ka-Duc;You, Jeong-Suk
    • Korean Journal of Social Welfare
    • /
    • v.62 no.1
    • /
    • pp.83-107
    • /
    • 2010
  • This study looked into the inner experience of foster mothers who adopted children under 3 months old and found out they were disabled while they were rearing with Van Manen's hermeneutic phenomenological approach. In-depth interviews were used with six foster mothers who live in Seoul, Gwangju, Gyeongsangnam-do, and Jeollabuk-do. The study resulted in a hermeneutic writing with titled "Love of Mothers Who Want to Make Their Children's Dreams Come True" with six essential themes as follows: 'being at a loss wrapped in a dense fog,' 'venting off the frustration,' 'gratitude amid painfulness,' 'bold confrontation with prejudices,' 'disabled children's return to the center of their moms' life,' and 'expectation for their future life.' As they are disabled, foster mothers want to rear their children with more care and attention to make their children's dreams come true. Seen above, this could be interpreted as mothers' love to a life. For foster mothers, the disability of their adopted children is not a burden but an expectation for a new world. They help the children live by themselves. It shows that every child can have his own home.

  • PDF

A Study on the Electrical and Optical Characteristics of CLN-PZT Ceramics (CLN-PZT 세라믹스의 전기, 광학 특성에 관한 연구)

  • Kang, Won-Koo
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.799-801
    • /
    • 1988
  • This paper was studied on the effects of Ca-La-Nb substitution and Zr/Ti ratio variation to Pb(Zr, Ti)$O_3$ system on structural, electrical, optical and sound level characteristics in order to develope the piezoelectric and electrooptic ceramic devices. Also the specimens were prepared by the two stage sintering technique. The molecular formular was X($CaO{\cdot}1/4La_{2}O_{3}{\cdot}1/4Nb_{2}O_{5}){\cdot}(1-X)Pb(Zr_{Y}Ti_{1-Y})O_{3}$(x=100X, y=100Y), and the variation of x was $6{\sim}12$, y was 60${\sim}$49 and second stage sintering time was 20${\sim}$40 hours. The experimental results obtained from this study are as follows : 1. The density was decreased, the grain size was increased according to increase of Ca-La-Nb substitution. 2. The crystal structure was rhombohedral in composition 6/60/40, and the crystal structure was tetragonal and cubic according to increase of Ca-La-Nb substitution. 3. The Ca substitution of PZT system enhanced the sintering property. The Pb site vacancy resulting from the substitution of La-Nb increased the dielectrical constant, the piezoelectric charge constant, the dielectric loss and decreased the coercive field. 4. The resistivity of PZT system which has the P type conduction mechanism increased according to substitution of La-Nb because of the substituent acting as donor. 5. The PZT ceramics varied from ferroelectric substance according to increase of Ca-La-Nb substituent. The coercive field and saturation remanent polarization decreased, and at last straight line according to increase of La-Nb substitution. 6. The amount of Ca-La-Nb substitution to improve the light transmittance of speciment was 10 mol%, the Zr/Ti ratio was 49/51, and the second stage sintering time was 40 hours. 7. According to Ca-La-Nb substitution, the specimens was to be transparent. The 7.5/51/49 specimen was suitable for transparent sound vibrator because it had 58% light transmittance (thick 0.2[mm], wave length 700[mm]) and 48% electromechanical coupling factor.

  • PDF

A "GAP-Model" based Framework for Online VVoIP QoE Measurement

  • Calyam, Prasad;Ekici, Eylem;Lee, Chang-Gun;Haffner, Mark;Howes, Nathan
    • Journal of Communications and Networks
    • /
    • v.9 no.4
    • /
    • pp.446-456
    • /
    • 2007
  • Increased access to broadband networks has led to a fast-growing demand for voice and video over IP(VVoIP) applications such as Internet telephony(VoIP), videoconferencing, and IP television(IPTV). For pro-active troubleshooting of VVoIP performance bottlenecks that manifest to end-users as performance impairments such as video frame freezing and voice dropouts, network operators cannot rely on actual end-users to report their subjective quality of experience(QoE). Hence, automated and objective techniques that provide real-time or online VVoIP QoE estimates are vital. Objective techniques developed to-date estimate VVoIP QoE by performing frame-to-frame peak-signal-to-noise ratio(PSNR) comparisons of the original video sequence and the reconstructed video sequence obtained from the sender-side and receiver-side, respectively. Since processing such video sequences is time consuming and computationally intensive, existing objective techniques cannot provide online VVoIP QoE. In this paper, we present a novel framework that can provide online estimates of VVoIP QoE on network paths without end-user involvement and without requiring any video sequences. The framework features the "GAP-model", which is an offline model of QoE expressed as a function of measurable network factors such as bandwidth, delay, jitter, and loss. Using the GAP-model, our online framework can produce VVoIP QoE estimates in terms of "Good", "Acceptable", or "Poor"(GAP) grades of perceptual quality solely from the online measured network conditions.

Design of 4-Pole Low Noise Active Bandpass Filter Improving Amplitude Flatness of Passband (통과대역 평탄도를 개선한 4단 저잡음 능동 대역통과 여파기 설계)

  • 방인대;전영훈;이재룡;윤상원
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.6
    • /
    • pp.590-598
    • /
    • 2004
  • An active capacitance circuit which employs series feedback network for the implement of negative resistance and low noise operation is analyzed in depth and its application to low noise active RF BPF's is discussed. Whereas many authors reported a lot of circuits that embody negative resistance circuit most of them have concerns for the equivalent resistance and reactance value at the center frequency. In this case, it could be possible to face a problem that the negative resistance circuit becomes unstable, or have poor flatness in passband because of insufficient forecast for the negative resistance values as the frequency goes higher or lower. In this paper, we extracted the exact equivalent values of this circuit and analyzed the RF characteristics with the varying the values of active devices and feedback circuits and presented the method that the flatness of passband can be improved. We have designed a 4-pole active BPF, which has the bandwidth of 60 ㎒, 0.67 ㏈ insertion loss, 0.3 ㏈ ripple, and noise figure of 3.0 ㏈ at 1.99 ㎓ band.