• Title/Summary/Keyword: Center Fast Edge Fast

Search Result 32, Processing Time 0.024 seconds

A Study on the Characteristics of Polishing Pad in STI-CMP Process (STI-CMP 공정에 미치는 연마 패드 특성에 관한 연구)

  • 박성우;박성우;김상용;이우선;장의구
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.54-57
    • /
    • 2001
  • We studied the characteristics of polishing pad, which can apply STI-CMP process for global planarization of multilevel interconnection structure. Also, we investigated the effects of different sets of polishing pad, such as soft and hard pad. As an experimental result, hard pad showed center-fast type, and soft pad showed edge-fast type. Totally, the defect level has shown little difference, however, the counts of scratch was defected less than 2 on JRlll pad. Through the above results, we can select optimum polishing pad, so we can expect the improvements of throughput and devise yield.

  • PDF

Optimization of Double Polishing Pad for STI-CMP Applications (STI-CMP 적용을 위한 이중 연마 패드의 최적화)

  • Park, Seong-U;Seo, Yong-Jin;Kim, Sang-Yong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.7
    • /
    • pp.311-315
    • /
    • 2002
  • Chemical mechanical polishing (CMP) process was required for the global planarization of inter-metal dielectric(IMD), inter-level dielectric (ILD) layers of multi-layer interconnections. In this paper, we studied the characteristics of polishing pad, which can apply shallow trench isolation (STI)-CMP process for global planarization of multi-level interconnection structure. Also, we investigated the effects of different sets of polishing pad, such as soft and hard pad. As an experimental result, hard pad showed center-fast type, and soft pad showed edge-fast type. Totally, the defect level has shown little difference, however, the counts of scratch was detected less than 2 on JR111 pad. Through the above results, we can select optimum polishing pad, so we can expect the improvements of throughput and device yield.

A Fast Pupil Detection Using Geometric Properties of Circular Objects (원형 객체의 기하학적 특성을 이용한 고속 동공 검출)

  • Kwak, Noyoon
    • Journal of Digital Convergence
    • /
    • v.11 no.2
    • /
    • pp.215-220
    • /
    • 2013
  • They are well-known geometric properties of a circle that the perpendicular bisector of a chord passes through the center of a circle, and the intersection of the perpendicular bisectors of any two chords is its center. This paper is related to a fast pupil detection method capable of detecting the center and the radius of a pupil using these geometric properties at high speed when detecting the pupil region for iris segmentation. The proposed method is characterized as rapidly detecting the center and the radius of the pupil, extracting the candidate points of the circle in human eye images using morphological operations, and finding two chords using four points on the circular edge, and taking the intersection of the perpendicular bisectors of these two chords for its center. The proposed method can not only detect the center and the radius of a pupil rapidly but also find partially occluded pupils in human eye images.

A Lightweight Pedestrian Intrusion Detection and Warning Method for Intelligent Traffic Security

  • Yan, Xinyun;He, Zhengran;Huang, Youxiang;Xu, Xiaohu;Wang, Jie;Zhou, Xiaofeng;Wang, Chishe;Lu, Zhiyi
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.12
    • /
    • pp.3904-3922
    • /
    • 2022
  • As a research hotspot, pedestrian detection has a wide range of applications in the field of computer vision in recent years. However, current pedestrian detection methods have problems such as insufficient detection accuracy and large models that are not suitable for large-scale deployment. In view of these problems mentioned above, a lightweight pedestrian detection and early warning method using a new model called you only look once (Yolov5) is proposed in this paper, which utilizing advantages of Yolov5s model to achieve accurate and fast pedestrian recognition. In addition, this paper also optimizes the loss function of the batch normalization (BN) layer. After sparsification, pruning and fine-tuning, got a lot of optimization, the size of the model on the edge of the computing power is lower equipment can be deployed. Finally, from the experimental data presented in this paper, under the training of the road pedestrian dataset that we collected and processed independently, the Yolov5s model has certain advantages in terms of precision and other indicators compared with traditional single shot multiBox detector (SSD) model and fast region-convolutional neural network (Fast R-CNN) model. After pruning and lightweight, the size of training model is greatly reduced without a significant reduction in accuracy, and the final precision reaches 87%, while the model size is reduced to 7,723 KB.

Evaluation of Image Quality by Using a Tungsten Edge Block in a Megavoltage (MV) X-ray Imaging (텅스텐 엣지 블록을 이용하여 Megavoltage (MV) 영상의 질 평가)

  • Min, Jung-Whan;Son, Jin-Hyun;Kim, Ki-Won;Lee, Jung-Woo;Son, Soon-Yong;Back, Geum-Mun;Kim, Jung-Min;Kim, Yeon-Rae;Jung, Jae-Yong;Kim, Sang-Young;Lee, Do-Wan;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.154-161
    • /
    • 2012
  • Digital Radiography (DR) has rapidly developed in megavoltage X-ray imaging (MVI). Thus, a very simple and general quality assurance (QA) method is required. The purpose of this study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS) and the detective quantum efficiency (DQE) for MVI using general QA method and computed radiography (CR) device. We used tungsten edge block with $19{\times}10{\times}1cm^3$ thickness and 6MV energy. For detector, CR-IP (image plate), CR-IP-lead, the CR-IP-back (lanex TM fast back screen), CR-IP-front (lanex TM fast front screen) were used and pre-sampling MTF was calculated. The MTF of CR-IP-front showed the highest value with 1.10 lp/mm although the CR-IP showed the only 0.70 lp/mm. The best NPS was observed in CR-IP front screen. According to the increase in spatial frequency, our results showed that DQE was approximately 1.0 cycles/mm. The present study demonstrates that the QA method with our home-made edge block can be used to evaluate MTF, NPS and DQE for MVI.

An efficient adaptive finite element method based on EBE-PCG iterative solver for LEFM analysis

  • Hearunyakij, Manat;Phongthanapanich, Sutthisak
    • Structural Engineering and Mechanics
    • /
    • v.83 no.3
    • /
    • pp.353-361
    • /
    • 2022
  • Linear Elastic Fracture Mechanics (LEFM) has been developed by applying stress analysis to determine the stress intensity factor (SIF, K). The finite element method (FEM) is widely used as a standard tool for evaluating the SIF for various crack configurations. The prediction accuracy can be achieved by applying an adaptive Delaunay triangulation combined with a FEM. The solution can be solved using either direct or iterative solvers. This work adopts the element-by-element preconditioned conjugate gradient (EBE-PCG) iterative solver into an adaptive FEM to solve the solution to heal problem size constraints that exist when direct solution techniques are applied. It can avoid the formation of a global stiffness matrix of a finite element model. Several numerical experiments reveal that the present method is simple, fast, and efficient compared to conventional sparse direct solvers. The optimum convergence criterion for two-dimensional LEFM analysis is studied. In this paper, four sample problems of a two-edge cracked plate, a center cracked plate, a single-edge cracked plate, and a compact tension specimen is used to evaluate the accuracy of the prediction of the SIF values. Finally, the efficiency of the present iterative solver is summarized by comparing the computational time for all cases.

Effect of Residual Stress in Al5083 TIG Weld Region on Fatigue Crack Propagation Behavior (Al5083재 TIG용접부의 잔류응력이 피로균열전파거동에 미치는 효과)

  • Lee, Ouk-Sub;Park, Chan-Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.23 no.6 s.165
    • /
    • pp.943-951
    • /
    • 1999
  • The welded structure unnecessarily remains residual stress due to the very high heating of local region and lastly cooling. The residual stress sometimes causes fracture initiation of welded structures. In this paper, distribution and magnitude of tensile and compressive residual stresses in the TIG(Tungsten Inert Gas) welded aluminum alloy such as Al5083-H112 are measured by using the hole-drilling method. Furthermore, the effects of residual stresses in the TIG welded aluminum CCT(Center Crack Tension) and SEN(Single Edge Notched) Specimens on the fatigue crack propagation behavior are analyzed. The fatigue cracks initiated at residual stresses region are influnced by tensile and compressive residual stresses. However, the effects are found to be released fast for both cases according to the cyclic loads and extension of crack length.

Differential Demodulation of GMSK in Rayleigh fading Channels

  • Choi, Joong-Ho;Han, Young-Yeul
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.16 no.2
    • /
    • pp.137-144
    • /
    • 1991
  • A new demodulation scheeme for differentially encoded GMSK signal is introduced and described. In the proposed differential detection method, the signal is sampled at the center of the time slot, at which the effect of the intersymbol interference is relatively smaller than the edge of the time slot. The proposed differential detector takes this adbantate. The error rate performance of the differential detector has been numerically calculated in the fast fading encountered in the land mobile radio channels. A comparison of performance with the differential detector for MSK signal is given. Finally the possibility of improving performance employing nonredudant error correction is studied.

  • PDF

Monitoring of anesthetic depth with q-EEG (quantitative EEG) in TIVA (total intravenous anesthesia) and VIMA (volatile induction/maintenance anesthesia) (완전정맥마취와 휘발성유도/유지마취에서 정량적 뇌파를 이용한 마취심도의 감시)

  • Lee, Soo-Han;Noh, Gyu-Jeong;Chung, Byung-Hyun
    • Korean Journal of Veterinary Research
    • /
    • v.46 no.1
    • /
    • pp.47-55
    • /
    • 2006
  • To evaluate method for monitoring anesthetic depth with quantitative electroencephalography (q-EEG), we recorded processed EEG (raw EEG) and pain score till 100 minutes in beagle dogs anesthetized for 60 minutes with propofol (n = 5, PRO group), isoflurane (n = 5, ISO group) and propofol-ketaminefentanyl (n = 5, PFK group). Raw EEG was converted into 95% spectral edge frequency (SEF) by fast Fourier transformation (FFT) method. We investigated anesthetic depth by comparing relationship (Pearson's correlation) between q-EEG (95% SEF) and pain score. Pearson's correlation coefficients are +0.2372 (p = 0.0494, PRO group), +0.79506 (p < 0.001, ISO group) and +0.49903 (p = 0.0039, PFK group).

Free Vibration Analysis of Axisymmetrical Circular Plate by Using Differential Transformation Method (미분변환법을 이용한 축대칭 원판의 자유 진동 해석)

  • Shin, Young-Jae;Yun, Jong-Hak;Jy, Young-Chel;Kim, Jun-Nyen;Ferdinand, T.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.604-607
    • /
    • 2005
  • The free vibration of solid circular plates has been studied using the differential transformation method(DTM). The effects such as mass at edge and elastic restraints have been considered. In order to avoid the singularity problem at the solid circular center two regularity conditions were applied with respect to the number of circumferential nodal line. The non-dimensional natural frequencies of the general circular plates were obtained for various boundary conditions. The results obtained by this method were compared with previous works. DTM showed fast convergency, accuracy, efficiency and validity in solving vibration problem of general circular plates.

  • PDF