• Title/Summary/Keyword: Center Error

Search Result 2,542, Processing Time 0.035 seconds

An Analysis of Human Factor and Error for Human Error of the Semiconductor Industry (반도체 산업에서의 인적오류에 대한 인적요인과 과오에 대한 분석)

  • Yun, Yong-Gu;Park, Beom
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2007.04a
    • /
    • pp.113-123
    • /
    • 2007
  • Through so that accident of semiconductor industry deduces unsafe factor of the person center on unsafe behaviour that incident history and questionnaire and I made starting point that extract very important factor. It served as a momentum that make up base that analyzes factors that happen based on factor that extract factor cause classification for the first factor, the second factor and the third factor and presents model of human error. Factor for whole defines factor component for human factor and to cause analysis 1 stage in human factor and step that wish to do access of problem and it do analysis cause of data of 1 step. Also, see significant difference that analyzes interrelation between leading persons about human mistake in semiconductor industry and connect interrelation of mistake by this. Continuously, dictionary road map to human error theoretical background to basis traditional accidental cause model and modern accident cause model and leading persons. I wish to present model and new model in semiconductor industry by backbone that leading persons of existing scholars who present model of existent human error deduce relation. Finally, I wish to deduce backbone of model of pre-suppression about accident leading person of the person center.

  • PDF

A STUDY OF ESTIMATION GROUND SURFACE TEMPERATURE BY TIME-SHIFT PROCESSING

  • Yano, Koji;KAJIWARA, Koji;HONDA, Yoshiaki;Moriyama, Masao
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.798-800
    • /
    • 2003
  • The time shift processing of ground measured surface temperature with the meteorological variables has no evaluated function. We introduce new evaluating function. To use this evaluating function, the algorithm of time-shift processing will be able to be reliable and get error-bar for all moving measured point's data. We will finally obtain the area averaged surface temperature by land observation.

  • PDF

Evaluation of the Intensity Predictability of the Numerical Models for Typhoons in 2013 (2013년 태풍에 대한 수치모델들의 강도 예측성 평가)

  • Kim, Ji-Seon;Lee, Woojeong;Kang, KiRyong;Byun, Kun-Young;Kim, Jiyoung;Yun, Won-Tae
    • Atmosphere
    • /
    • v.24 no.3
    • /
    • pp.419-432
    • /
    • 2014
  • An assessment of typhoon intensity predictability of numerical models was conducted to develop the typhoon intensity forecast guidance comparing with the RSMC-Tokyo best track data. Root mean square error, box plot analysis and time series of wind speed comparison were performed to evaluate the each model error level. One of noticeable fact is that all models have a trend of error increase as typhoon becomes stronger and the Global Forecast System showed the best performance among the models. In the detailed analysis in two typhoon cases [Danas (1324) and Haiyan (1330)], GFS showed good performance in maximum wind speed and intensity trend in the best track, however it could not simulate well the rapid intensity increasing period. On the other hand, ECMWF and Hurricane-WRF overestimated the typhoon intensity but simulated track trend well.

The Effect of Communication Distance and Number of Peripheral on Data Error Rate When Transmitting Medical Data Based on Bluetooth Low Energy (저 전력 블루투스 기반으로 의료데이터 전송 시 통신 거리와 연동 장치의 수가 데이터 손실률에 미치는 영향)

  • Park, Young-Sang;Son, ByeongJin;Son, Jaebum;Lee, Hoyul;Jeong, Yoosoo;Song, Chanho;Jung, Euisung
    • Journal of Biomedical Engineering Research
    • /
    • v.42 no.6
    • /
    • pp.259-267
    • /
    • 2021
  • Recently, the market for personal health care and medical devices based on Bluetooth Low Energy(BLE) has grown rapidly. BLE is being used in various medical data communication devices based on low power consumption and universal compatibility. However, since data errors occurring in the transmission of medical data can lead to medical accidents, it is necessary to analyze the causes of errors and study methods to reduce data error. In this paper, the minimum communication speed to be used in medical devices was set to at least 800 byte/sec based on the wireless electrocardiography regulations of the Ministry of Food and Drug Safety. And the data loss rate was tested when data was transmitted at a speed higher than 800 byte/sec. The factors that cause communication data error were classified, and the relationship between each factor and the data error rate was analyzed through experiments. When there were two or more activated peripherals connected to the central, data error occurred due to channel hopping and bottleneck, and the data error rate increased in proportion to the communication distance and the number of activated peripherals. Through this experiment, when the BLE is used in a medical device that intermittently transmits biosignal data, the risk of a medical accident is predicted to be low if the number of peripherals is 3 or less. But, it was determined that BLE would not be suitable for the development of a biosignal measuring device that must be continuously transmitted in real time, such as an electrocardiogram.

Comparison of dose-variation in skin due to Set-up error in case of radiation therapy for left breast using Volumetric Modulated Arc Therapy(VMAT) (좌측 유방에 대한 용적 변조 회전 방사선 치료 시 자세 오차로 인한 피부 선량)

  • Kwon, Yongjae;Park, Ryeunghwang;Kim, Seyoung;Jung, Dongmin;Baek, Jonggeol;Cho, Jeonghee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.55-62
    • /
    • 2021
  • Purpose: This study aims to contribute to the reduction of complications of breast cancer radiation therapy by analyzing skin dose differences due to Set-up error. Materials and Method: Pseudo breast was produced using a 3D printer, applied to the phantom, and images were acquired through CT. Treatment plan was carried out that the PTV, which contains 95% of the prescription dose, could be more than 95% of the volume, so that Dmax did not exceed 107% of the prescription dose. The Set-up error was evaluated by applying ±1mm/±3mm/±5mm to the X-axis, Y-axis, and Z-axis. Results: The dose-variation in skin due to Set-up error was approximately 106% to 123% compared to prescription dose, and the highest dose in skin was 49.24 Gy at 5mm Set-up error in the lateral direction of the X-axis. More than 107% of the prescription dose was the widest at 6.87 cc in skin lateral. Conclusions: If a Set-up error occurs during left breast cancer VMAT, a great difference in skin dose was shown in the lateral direction of the X-axis. If more effort is made to align the X-axis of the breast treated during CBCT registration, the dose-variation of skin will be reduced.

Volumetric Error Compensation of a 3-Axis Horizontal Machining Center in the Post-processor (후처리기에 의한 3축 수평머시닝센터의 체적오차보정)

  • 양승한;권성환
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.3
    • /
    • pp.28-34
    • /
    • 1999
  • The objective of this study is to estimate and to compensate far the volumetric error of a workpiece influenced by the geometric error of a machine tool. In this paper, the volumetric error is defined and the error synthesis model is presented. Then, the volumetric error of workpiece is calculated and compared through the simulation, and a new tool-path is generated to compensate for the error in the post-processor of CAM system using the error synthesis model. By this method, the error is compensated without modification or replacement of a machine tool being in use.

  • PDF

Fingerprint Images Registration Method by Recursive Ridge Mapping (점진적 융선 정합을 통한 지문 영상 정렬 방법)

  • Choi, Kyoung-Taek;Choi, Hee-Seung;Kim, Jai-Hie
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.1007-1010
    • /
    • 2005
  • This paper presents a fingerprint image registration method. In the fingerprint system, the insufficiency of mutual information between a template and a query fingerprint is one of major factors to deteriorate recognition performance. To overcome this problem, we need to register multiple impressions and integrate their information. Our method matches the ridges from multiple impressions recursively and then registers the impressions to minimize the registration error calculated from the Distance map. Our method use regularized TPS model as the transformation model to compensate for the plastic deformation. We compare our method with 3 prior arts (ICP, Distance Map, Ross's method). Our registration error and its' variance is the smallest and also the average registration error is below 3 pixels.

  • PDF

Touchpad for Force and Location Sensing

  • Kim, Dong-Ki;Kim, Jong-Ho;Kwon, Hyun-Joon;Kwon, Young-Ha
    • ETRI Journal
    • /
    • v.32 no.5
    • /
    • pp.722-728
    • /
    • 2010
  • This paper presents the design and fabrication model of a touchpad based on a contact-resistance-type force sensor. The touchpad works as a touch input device, which can sense contact location and contact force simultaneously. The touchpad is 40 mm wide and 40 mm long. The touchpad is fabricated by using a simple screen printing technique. The contact location is evaluated by the calibration setup, which has a load cell and three-axis stages. The location error is approximately 4 mm with respect to x-axis and y-axis directions. The force response of the fabricated touchpad is obtained at three points by loading and unloading of the probe. The touchpad can detect loads from 0 N to 2 N. The touchpad shows a hysteresis error rate of about 11% and uniformity error rate of about 3%.

Torque and Force Measurement of a Prototype HAU Reaction Wheel and the Effect of Disturbance on the Attitude Stability of Spacecraft

  • Oh, Hwa-Suk;Kwon, Jae-Wook;Lee, Hyunwoo;Nam, Myung-Ryong;Park, Dong-Jo
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.743-751
    • /
    • 2001
  • A Prototype reaction wheel, named the Hankuk Aviation University (HAU) reaction wheel, has been developed for KAISTSAT satellite series. Torque and force disturbances are inherent in reaction wheels, and thus the force and torque characteristics should be examined for every newly developed reaction wheel. The torque and force disturbance noises in the prototype HAU reaction wheel are measured with a torque-measuring table developed for the present study. A new measuring procedure based on a simple principle is applied for the measurements. The frequency characteristics of the torque and force noises are analyzed by examining the power spectral density. The effect of the torque noise on the attitude stability is also examined through numerical simulations with a single-axis attitude model. The noise-induced attitude error and jitter and found to be well below the specified error limits for the KAISTSAT satellite series.

  • PDF

High Precision Path Generation of an LCD Glass-Handling Robot

  • Cho, Phil-Joo;Kim, Hyo-Gyu;Kim, Dong-Il
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2311-2318
    • /
    • 2005
  • Progress in the LCD industries has been very rapid. Therefore, their manufacturing lines require larger LCD glass-handling robots and more precise path control of the robots. In this paper, we present two practical advanced algorithms for high-precision path generation of an LCD glass-handling robot. One is high-precision path interpolation for continuous motion, which connects several single motions and is a reliable solution for a short robot cycle time. We demonstrate that the proposed algorithm can reduce path error by approximately 91% compared with existing algorithms without increasing cycle time. The second is real-time static deflection compensation, which can optimally compensate the static deflection of the handling robot without any additional sensors, measurement instruments or mechanical axes. This reduces vertical path error to approximately 60% of the existing system error. All of these algorithms have been commercialized and applied to a seventh-generation LCD glass-handling robot.

  • PDF