• Title/Summary/Keyword: Cellulose mixed ester

Search Result 12, Processing Time 0.026 seconds

The Effect of Water Activation on Chemical Modification of Cellulose and Characterization (Water activation에 기반한 셀룰로오스의 개질 및 특성)

  • Kim, Hae-Ri;Nam, Byeong-Uk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.977-982
    • /
    • 2013
  • Cellulose mixed esters (CME), substituted by various fatty acyl chains, are renewable bio-based polyesters. It has lots of potential due to the biodegradable property. In this study, Alpha cellulose was activated for 2h at $40^{\circ}C$ in deionized water prior to synthesis. Homogeneous esterification of CME was accomplished with water-activated alpha cellulose, various saturated fatty acids and acetic anhydride in lithium chloride/N,N-dimethylacetamide (LiCl/DMAc) medium. CME was obtained after 5 hr at $120^{\circ}C$. The filtrated products were characterized using TGA, FT-IR, 1H-NMR and FE-SEM, and the influence of water activation on the total degree of substitution was investigated.

Optimal filter materials for protist quantification via droplet digital PCR

  • Juhee Min;Kwang Young Kim
    • ALGAE
    • /
    • v.39 no.1
    • /
    • pp.51-56
    • /
    • 2024
  • The use of droplet digital polymerase chain reaction (ddPCR) has greatly improved the quantification of harmful protists, outperforming traditional methods like quantitative PCR. Notably, ddPCR provides enhanced consistency and reproducibility at it resists PCR inhibitors commonly found in environmental DNA samples. This study aimed to determine the most effective filter material for ddPCR protocols by assessing the reproducibility of species-specific gene copy numbers and filtration time across six filter types: cellulose acetate (CA), mixed cellulose ester (MCE), nylon (NY), polycarbonate (PC), polyethersulfone (PES), and polyvinylidene fluoride (PVDF). The study used two species of Chattonella marina complexes as a case study. Filtration rates were slower for NY, PC, and PVDF filters. Moreover, MCE, NY, PES, and PVDF yielded lower DNA amounts than other filters. Importantly, the CA filter exhibited the lowest variance (38-39%) and the highest determination coefficients (R2 = 0.92-0.96), indicating superior performance. These findings suggest that the CA filter is the most suitable for ddPCR quantification of marine protists, offering quick filtration and reliable reproducibility.

A Study on the Durable Press Finishing of Cotton Fiber Treated with Polycarboxylic Acid (폴리카르복시 산 처리 면섬유의 DP가공에 관한 연구)

  • 이찬민;최철민
    • Textile Coloration and Finishing
    • /
    • v.9 no.6
    • /
    • pp.58-67
    • /
    • 1997
  • PTCA(1,2,3-propanetricarboxylic acid) and BTCA(1,2,3-butanetetracarboxylic acid) are selected as new nonformaldehyde agents for ester crosslinking of cotton cellulose to replace the traditional DMDHEU reagent. A goal of this research is to propose unknown ester mechanism of cotton cellulose by PTCA or BTCA using crystal structure model suggested by Meyer and Takahashi. In pursuit of these goals, we have treated 100% cotton broad cloth with PTCA or BTCA and different catalysts. They were used with $NaH_2PO_2,\;NaH_2PO_4,\;Na_2HPO_4,\;NaH_2PO_2,\;Na_3PO_4,$ catalysts to produce nonformaldehyde fabric finishes. Treatments were applied to all cotton fabrics using a pad-dry -cure process. The esterfication of cotton treated with BTCA or PTCA was investigated using Fourier transform infrared(FT-IR) spectra and the breaking strength, abrasion retention and discoloration properties were determined to prove the durable finished fabrics. Patterns with respect to abrasion resistance were more complex. Because PTCA and BTCA add-ons were comparable, the data suggest that the more effective catalysts, $NaH_2PO_2$ and mixed phosphate $NaH_2PO_2/NaH_2PO_4$) are effecting either a great number of crosslinks in the cotton or producing crosslinks that differ in actual structure.

  • PDF

Comprehensive Review of Endotoxin Level Reported in Metalworking Operations (금속 가공유 취급 공정에서 엔도톡신 발생 및 노출 특성 고찰)

  • Park, Dong-Uk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.4
    • /
    • pp.405-415
    • /
    • 2014
  • Objectives: The aim of this study is to comprehensively summarize endotoxin levels reported in operations using metalworking fluids(MWFs). Methods: An extensive literature review was conducted of studies reporting endotoxin levels in processes using metalworking fluids. Keyword search terms included 'metalworking fluids', 'machining fluids', 'metalworking operation', 'machining operation' and 'endotoxin', which were used in combination. Results: A total of ten manuscripts were found to report on airborne endotoxin levels from metalworking operations in the automobile industry. Polycarbonate(PC), polyvinyl chloride(PVC) and mixed cellulose ester(MCE) were used to collect airborne endotoxin. Limulus Amebocyte Lysate was mainly used to quantify endotoxin amount. The levels of airborne endotoxin reviewed varied considerably, ranging from < $4EU/m^3$ to $790EU/m^3$, which was found to be far lower than those from cotton and potato processing plants, sawmills, and poultry farms. Several studies assumed that exposure to endotoxin could be a causative agent of respiratory diseases. Conclusions: Inhalation endotoxin exposure levels reported from metalworking operations were found to be lower than those from industries handling organic materials, even though it could be considered as a possible cause for several respiratory diseases.

Effects of the Feeding Platycodon grandiflorum and Codonopsis Ianceolata on the Fatty Acid Composition of Serum and Liver in Rats (도라지 및 더덕 첨가식이가 흰쥐의 혈청 및 간장의 지방산 조성에 미치는 영향)

  • 김소영;김한수;김성희;김희숙;서인숙;정승용
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.22 no.5
    • /
    • pp.524-530
    • /
    • 1993
  • This study was designed to observe the effects of the feeding Platycodon grandiflorum, Codonopsis Ianceolata, perilla oil and safflower oil on the fatty acid composition in serum and liver of dietary hypercholesterolemic rats. Experimental groups mixed with 5% cellulose +10% lard (group 1, control group), 2% cholestyraemine +10% lard (group 2), 5% C. ianceolata+ 10% perilla oil (group 3), 5% P. grandiflorum+10% perilla oil (group 4), 5% C. ianceolata+10% safflower oil (group 5) and 5% P. grandiflorum+10% safflower oil (group 6) were administered to the male rats of the Sprague Dawley for 3 weeks. In the fatty arid compositions of serum total fatty arid, phospholipid, triglyceride and cholesteryl ester, the linoleic acid content was most in the PUFA and it was major fatty acid. Particularly, the other components except the phospholipid fraction in serum lipids were influenced by the fatty acid composition of the test lipids from the fact that linoleic acid content was remarkably more in the groups 5 and 6. In the fatty arid compositions of liver total fatty acid, phospholipid, triglyceride and cholesteryl ester, the linoleic acid content was more in the PUFA and so it was major fatty acid. Particularly, the arachidonic and eicosapentaenoic acid contents of phospholipid fraction in liver lipids were rather more. from the above research, fatty arid composition of serum and liver lipid components were influenced by the fatty acid composition of the test lipids from the fact that linoleic acid takes up the highest percentage.

  • PDF

Accuracy and Precision of Microwave Oven Digestion/Atomic Absorption Spectrophotometry for Analyzing Airborne Chromium Collected on MCE Filter in Plating Operation (도금공정 크롬시료 분석을 위한 Microwave Oven Digestion/Atomic Absorption Spectrophotometry 방법의 정확도 및 정밀도 평가)

  • Lee, Byung-Kyu;Lee, Ji-Tae;Shin, Yong-Chul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.1
    • /
    • pp.48-55
    • /
    • 2001
  • The purpose of this study was to evaluate the analytical accuracy and precision of microwave oven digestion/atomi absorption spectrophotometry (AAS) for analyzing airborne chromium collected on mixed cellulose ester membrane (M filter from the work environment, and to compare the accuracy and the precision with those of the National Institute for Occupational Safety and Health (NIOSH) Method #7024 hot plate digestion/AAS method. For this study, field air sample pairs were collected from a electroplating process, and spiked samples in a laboratory were prepared and using these samples. Two digestion methods were comp; and evaluated in terms of recovery rate and bias as indices of accuracy and coefficient of variation as a index of precision. The results and conclusions are as follows. In spiked samples, the accuracies (% mean recoveries) of hot plate/AAS and microwave oven/AAS method were 97.19%, 97.1%, respectively, and the precisions (pooled respectively, and the precisions (pooled coefficient of variance, $CV_{pooled}$) 6.93% and 3.88%, respectively. The biases of hot plate ani microwave oven methods were 4.56 - 14.7% and 2.22 - 7.42% respectively. There was no statistically significant difference between hot plate and microwave oven methods recovery rates of spiked samples (p>0,05). Also, no statistically significant difference was shown among the concentrations of air samples determined by two method (p>0.05). In conclusion, microwave oven/AAS method h excellent accuracy and precision, and advantages such as time-saving and simple procedure in comparison with the classical NIOSH method. Therefore, this method can be use widely to analyze airborne chromium collected on MCE filter from the work environments.

  • PDF

A Study on Filtration Efficiency of Several Dust Masks for Stainless Steel arc Welding fume (방진마스크의 Stainless steel arc 용접흄 여과효율에 관한 연구)

  • Song, Kyung-Seuk;Kwon, Yong-Shick;Han, Kuy-Tae;Chung, Kyu-Hyuck;Lee, Yong-Mook;Yu, Il-Je
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.1
    • /
    • pp.42-47
    • /
    • 2001
  • The purpose of this study was to investigate for filtration efficiency of several dust masks, comparing with filtration efficiency certified by KOSHA(Korea Occupational Safety & Health Agency), and to require of the right use of protective respirators. Using a welding fume generator and chamber, several dust masks, which were widely used in the workplaces in korea, were tested for their filtering efficiency for stainless steel arc welding fume. The filtration efficiency testing system consisted of a welding fume generator, a chamber and a filtration unit. The filtration unit was made of a mask which was inserted into the sampling cassette and another sampling cassette, which contained mixed cellulose ester filter paper. These two cassettes were connected with tubing. Stainless steel arc welding fume generator was delivered into an chamber. The welding fume in the chamber was passed into the filtration unit with flow rate of 30 liter/min. The welding fume filtration efficiency was evaluated by gravimetric measurement. Metal concentrations in the welding fume before and after filtration were measured with inductive coupling plasma analyzer. Following results were obtained: Filtration efficiency of welding fume for common hygienic mask was 63.82% and the average efficiencies for A, B, C, D, E, F and G masks were 94.62%, 96.58%, 83.20%, 82.76%, 77.25%, 86.55% and 93.22%, respectively. Our results indicate that dust masks used widely in the welding workplaces in korea are not proper for protecting worker's health and then the use of fume mask should be required.

  • PDF

Evaluation of Accuracy and Precision of Analysis of Metals with Polyvinyl Chloride Membrane Filters (PVC 여과지를 이용한 금속 분석방법에 대한 정확도와 정밀도 평가)

  • Byun, Seong-Uk;Choi, Sangjun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.1
    • /
    • pp.48-57
    • /
    • 2016
  • Objectives: This study was conducted to evaluate the accuracy and precision of airborne metal analysis using polyvinyl chloride(PVC) membrane filter by pretreatment methods. Methods: A total of 75 spiked PVC samples for Cr, Fe and Mn ranged from 6 ug/sample to 40 ug/sample were used to evaluate recovery rates for three pretreatment methods: acid extraction, hot plate ashing and microwave digestion. For Mn, an additional 75 spiked mixed cellulose ester(MCE) membrane filters were analysed to compare the recovery rates of PVC samples. All samples were analysed with an inductively coupled plasma optical emission spectrometer(ICP-OES) and manganese samples were additionally analyzed by atomic absorption spectrometer(AAS). Results: The overall mean recovery rates of PVC samples for Cr, Fe and Mn were 90% or higher regardless of pretreatment methods, but there were statistically significant differences in recovery rates for Cr(p<0.05) and Mn(p<0.01) samples by pretreatment methods. The biases and the coefficient variations of PVC samples for three metals pretreated with three kinds of pretreatment methods ranged from 1.7% to 4.7% and from 1.6% to 6.5%, respectively. The manganese PVC samples pretreated by microwave digestion and analyzed with ICP-OES had the lowest bias at 1.9% and also showed lower bias than the bias for MCE samples, 2.7%. Conclusions: In order to accurately analyze the metals sampled with PVC membrane filters, microwave digestion and ICP-OES can be recommended.

Determination of Airborne Fiber Size and Concentration in RCF Manufacturing and Processing Factories (세라믹 섬유 제조 및 가공 공정에서 발생된 공기중 섬유의 농도 및 크기 분포)

  • 신용철
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.4
    • /
    • pp.21-28
    • /
    • 2000
  • Various man-made mineral fibers(MMMF) including refractory ceramic fiber(RCF) have been used widely in industries as insulation materials. The effect of fibrous dust on human health depends on fiber size, concentration (exposure level), and durability in biological system. Therefore, these parameters should be determined to evaluate accurately the potential risk of fibers on human health. The purpose of this study was to characterize the size of airborne fiber and the workers' exposure to airborne fibers in refractory ceramic fiber manufacturing and processing factories. Airborne fibers were collected on 25-mm mixed cellulose ester membrane filters at personal breathing zones, and analyzed by A and B counting rules of the National Institute for Occupational Safety and Health(NIOSH) Method # 7400. The average ratios of the fiber density by B rule to the fiber density by A rule was 0.84. This result indicates that the proportion of respirable fibers (<3 ${\mu}{\textrm}{m}$ diameter) in air samples was high. The average diameter and length of airborne fibers were 1.05${\mu}{\textrm}{m}$ and 35${\mu}{\textrm}{m}$, respectively. The average fiber concentrations (GM) of all personal samples was 0.26f/cc, and the average concentration was highest at blanket cutting and packing processes. The fifty seven percent of personal air samples was exceeded the proposed American Conference of Governmental Industrial Hygienists(ACGIH) Threshold Limit Value(TLV), i.e. 0.2 f/cc. It was concluded that the RCF industrial workers had the higher potential health risk due to small fiber diameter, long fiber length, and high exposure level to the airborne fibers.

  • PDF

A Study on Metal Concentrations in the Air of Metal Products Manufacturing Industry (금속제품 제조 산업장내 공기중 금속농도에 관한 연구)

  • Kang, Yong Seon;Kim, Se Dong;Ku, Tae Hyeong;Yoon, Hyeong Ryeol;Moon, Deog Hwan;Han, Yong Soo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.2
    • /
    • pp.249-264
    • /
    • 1996
  • This study was conducted for the purpose of obtaining the fundamental data on improvement of working environment and contributing to health improvement of workers who dealed with metal by assessing the metal concentration in air of industries located in Chang-Won Industrial Complex. Authors measured the concentration of metals(Al, Cd, Cr, Cu, Mn, Ni, Pb, Sn and Zn) is the air to 25 working processes of 73 industries by flame atomic absorption spectrometry from February to December 1994. Personal air sampler was used for air sampling with mixed cellulose-ester membrane filter. The results were as follows : 1. The geometric means(range) of metal concentration; 1) Al: $0.1505mg/m^3$ ($0.0147-18.6100mg/m^3$) 2) Cd: $0.0077mg/m^3$ ($0.0003-7.0710mg/m^3$) 3) Cr: $0.0163mg/m^3$ ($0.0013-1.1510mg/m^3$) 4) Cu: $0.0097mg/m^3$ ($0.0009-0.4950mg/m^3$) 5) Mn: $0.0412mg/m^3$ ($0.0006-4.7877mg/m^3$) 6) Ni: $0.0088mg/m^3$ ($0.0001-1.0170mg/m^3$) 7) Pb: $0.0152mg/m^3$ ($0.0015-0.4499mg/m^3$) 8) Sn: $0.0486mg/m^3$ ($0.0037-0.1500mg/m^3$) 9) Zn: $0.1911mg/m^3$ ($0.0122-8.2920mg/m^3$) 2. The geometric mean of lead exceeded TWA in assembling process of other general purpose machinery not elsewhere classified products manufacturing industries.

  • PDF