• 제목/요약/키워드: Cell-based sensor

검색결과 185건 처리시간 0.023초

세포대사 기능 분석을 위한 광학센서 기반 용존산소와 pH 측정 시스템의 제작 및 특성 분석 (Characteristics and Fabrication of Dissolved Oxygen and pH Measurement System based on the Optical Sensor for Analysis of Cell Metabolic Functions)

  • 장지운;황인숙;이종목;이선민;강소라;김영미;김나영
    • 센서학회지
    • /
    • 제25권1호
    • /
    • pp.51-56
    • /
    • 2016
  • This study evaluates the performance of an optical sensor and measurement system (CMA-24) which can analyze the fluctuation of dissolved oxygen and pH simultaneously. In the optical sensor system, the fluorescent materials, Rudpp and HPTS which are sensitive to dissolved oxygen and pH, respectively, are coated on the bottom of a 24-well -plate by the sol-gel technology. The detection times of the emission light of the oxygen sensor were $4,186{\pm}13.90{\mu}s$ and $4,452{\pm}36.68{\mu}s$ for the dissolved oxygen of 17% $O_2$ and 7.6% $O_2$, respectively. On the other hand, the detection times of the pH sensor were $6,699.43{\pm}14.64{\mu}s$, $6,722.24{\pm}6.21{\mu}s$, and $6,748.52{\pm}2.63{\mu}s$ using pH 6, 7, and 8, respectively. When we determined cellular respiration levels of C2C12 myocytes with CMA-24, $O_2$/pH measurement system, the ratio of the uncoupled to coupled OCR (oxygen consumption rate) was 1.41. The results mean that this CMA-24 system shows almost the same sensitiveness as the commercial system.

Soft Computing을 이용한 배열 센서 시스템의 제어 성능 개선 (Improvement of Control Performance of Array-Sensor System Using Soft Computing)

  • 나승유;안명국
    • 센서학회지
    • /
    • 제12권2호
    • /
    • pp.79-87
    • /
    • 2003
  • 본 논문에서는 비선형 특성을 갖는 센서 배열을 사용하는 시스템에서, 센서 배열에 soft computing을 이용하여 선형적인 특성을 얻고, 배열의 특성을 이용하여 외란의 영향을 감소시켜 시스템의 성능을 향상시키는 방법을 제안한다. 대표적인 예로 배열에 사용된 광전도 센서인 CdS는 단일 CdS 셀 조차도 비선형적인 특성을 갖고 있기 때문에 비선형 특성을 소속 함수로 표현하는 퍼지 변수를 사용한다. 배열로 사용되는 센서에 각 단일 센서의 소속 함수와 특성을 이용하는 퍼지 논리를 적용하여 전체적으로 선형화된 센서 특성을 얻는다. 각 센서의 비선형적 요소를 표현하는 소속함수의 파라미터들에 유전 알고리즘을 사용하여 최적화 된 선형 특성을 얻어 시스템의 성능을 향상시킬 수 있다. 또한 보정을 위한 센서를 추가하지 않고 센서 배열의 특성을 이용하여 광전도 센서가 민감한 영향을 받는 외란을 보정하여 시스템의 외란 제거 성능을 향상시킬 수 있다. CdS 센서 배열의 자체 비선형성 뿐만 아니라 입력되는 물체의 그림자는 경계가 뚜렷하지 않고 흐릿하므로 퍼지 논리를 이용하는 방법이 거리측정과 외부 광원에 의한 외란에 대해 향상된 결과를 보인다. 제안된 방법을 적용한 센서 배열을 자기부상(Magnetic Levitation System)에서 볼의 거리 측정에 적용하여 성능을 검증한다.

스마트 센서 기술 융합을 통한 망 생존성 강화에 관한 연구 (A Study on the Enhancement of Network Survivability through Smart Sensor Technologies Convergence)

  • 양정모;김정호
    • 디지털융복합연구
    • /
    • 제14권8호
    • /
    • pp.269-276
    • /
    • 2016
  • 재난망용 LTE(Long Term Evolution)는 자가망을 기본으로 구축하고 일부 상용망 시설을 활용함으로써 비용을 절감하는 방향으로 구축되고 있다. 하지만, LTE 망은 기지국, 교환기 등 정보통신 기반시설 붕괴 시 망 생존성과, 폐쇄된 건물 내부 또는 지하구간 등 음영지역에서의 통신 커버리지가 취약하다는 한계가 있다. 본 연구에서는 기존에 활용하고 있는 검증된 기술들의 융합을 통해 망 생존성 기술을 제공하는 방안을 도출하였다. IoT시대의 도래에 따라, 사물과 환경 속에 내재된 스마트 센서는 컴퓨팅 파워와 네트워킹 모듈을 포함하여 망 생존성 구현을 위해 매우 유용한 기반을 제공한다. 본 연구에서는, 이러한 스마트센서의 특성을 기반으로 스몰셀 기술과 무선 네트워크 커버리지 확장기술을 융합함으로써 망 생존성을 효과적으로 구현하기 위한 USN(Ubiquitous Sensor Network) 싱크노드 아키텍처를 기획하였다. 사물과 환경 속에 내재된 컴퓨팅 파워는 재난재해 발생 시 유용한 자원으로 활용될 수 있을 것으로 기대된다.

Design of a 25 mW 16 frame/s 10-bit Low Power CMOS Image Sensor for Mobile Appliances

  • Kim, Dae-Yun;Song, Min-Kyu
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제11권2호
    • /
    • pp.104-110
    • /
    • 2011
  • A CMOS Image Sensor (CIS) mounted on mobile appliances requires low power consumption due to limitations of the battery life cycle. In order to reduce the power consumption of CIS, we propose novel power reduction techniques such as a data flip-flop circuit with leakage current elimination and a low power single slope analog-to-digital (A/D) converter with a sleep-mode comparator. Based on 0.13 ${\mu}m$ CMOS process, the chip satisfies QVGA resolution (320 ${\times}$ 240 pixels) that the cell pitch is 2.25 um and the structure is a 4-Tr active pixel sensor. From the experimental results, the performance of the CIS has a 10-b resolution, the operating speed of the CIS is 16 frame/s, and the power dissipation is 25 mW at a 3.3 V(analog)/1.8 V(digital) power supply. When we compare the proposed CIS with conventional ones, the power consumption was reduced by approximately 22% in the sleep mode, and 20% in the active mode.

A Possible Application of the PD Detection Technique Using Electro-Optic Pockels Cell With Nonlinear Characteristic Analysis on the PD signals

  • Kang, Won-Jong;Lim, Yun-Sok;Chang, Young-Moo;Koo, Ja-Yoon
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제11C권2호
    • /
    • pp.6-11
    • /
    • 2001
  • Abstract- In this paper, a new Partial Discharge (PD) detection using Pockels cell was proposed and considerable apparent chaotic characteristics were discussed. For this purpose, PD was generated from needle-plane electrode in air and detecte by optical measuring system using Pockels cell, based on Mach-Zehner interferometer, consisting of He-Ne laser, single mode optical fiber, 50/50 beam splitter and photo detector. In addition, the presence of chaos of the PD signals has been investigated by examining their means of qualitative and quantitative information. For the former, return map and 3-dimensional strange attractor have been drawn in order to investigate the presence of chaotic characteristics relevant to PD signals, detected through CT and Peckels sensor respectively, in the normalized time series. The presence of strange attractor indicates the existence of fractal structures in it's phase space. For the latter, several dimension values of strange attractor were verified sequentially. Throughout this paper, it is likely that the chaotic characteristics regarding the PD signals under air are verified.

연속 기체흐름계 및 일시 기체흐름계에서의 고체 전해질 $CO_2$ 가스센서의 열역학적 분석 (Thermodynamic Analysis of Solid Electrolyte $CO_2$ Sensor in Continuous and Discontinuous Flow Systems)

  • 최순돈
    • 센서학회지
    • /
    • 제7권5호
    • /
    • pp.319-326
    • /
    • 1998
  • 연속 기체흐름계에서 감지막으로 $Na_2CO_3$$MCO_3$ ($M=Cs_2,K_2,Li_2,Ca$)를 입힌 $Na^+$ 이온 전해질 센서가 $CO_2$ 가스를 감지할 때 anode반응을 도출하였다. 흔히 사용되는 전기화학 센서에 대해 일반적으로 알려진 전체 전극반응인 $MCO_3=MO+CO_2$ 반응은 위의 $Na^+$이온 전해질 센서에는 적합한 반응이 아니었다. 따라서 anode 반응은 전체cell 내의 ionic balance를 유지하기 위해 전해질과 감지막 계면에 이온교환반응을 첨가시킴으로써 도출할 수 있었으며 anode반응은 $Na_2CO_3$ 및 감지막의 금속($M^{++}$) 이온이 포함된 산화물이 참가하는 반응임을 알 수 있었다. 이와 같이 도출된 전극반응으로부터 구한 EMF와 일시 기체흐름계에서의 출력 EMF와의 차이를 아울러 검토하였다. 이러한 출력에서의 차이는 $CO_2$$O_2$의 분압과 분위기가스와 전극물질과의 비가역반응에 기인됨을 알았다.

  • PDF

복수개의 로보트와 다중센서를 이용한 정밀조립용 로보트 시스템 개발에 관한 연구 (Development of high precision multi arms robot system consist of two robot arms and multi sensors)

  • 임미섭;조영조;이준수;박정민;김광배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 A
    • /
    • pp.422-424
    • /
    • 1992
  • In this paper, we are designed a hierachical system controller and builed a robot system for high precision assembly consisting in multi-arms and multi-sensor. For the control of a multi-arms robot system, the robot system are consisted of cell controller, station controller and device. The Operating System of a cell controller is VxWorks for real-time multi-processing. Using by C-language, we are proposed a multi-arms robot control language based a RCCL, and this control language is partially implemented and tested in multi-robot control system.

  • PDF

Contractile Force Measurements of Cardiac Myocytes Using a Micro-manipulation System

  • Park Suk-Ho;Ryu Seok-Kyu;Ryu Seok-Chang;Kim Deok-Ho;Kim Byung-Kyu
    • Journal of Mechanical Science and Technology
    • /
    • 제20권5호
    • /
    • pp.668-674
    • /
    • 2006
  • In order to develop a cell based robot, we present a micro-mechanical force measurement system for the biological muscle actuators, which utilize glucose as a power source. The proposed measurement system is composed of a micro-manipulator, a force transducer with a glass probe, a signal processor, an inverted microscope and video recording system. Using this measurement system, the contractile force and frequency of the cardiac myocytes were measured in real time and the magnitudes of the contractile force of each cardiac myocyte under different conditions were compared. From the quantitative experimental results, we could estimate that the force of cardiac myocytes is about $20\sim40{\mu}N$, and show that there are differences between the control cells and the micro-patterned cells.

포켈스 효과를 이용한 불평등 전계 측정 (A possible application of the nonuniform electric field measurement using Pockets effect)

  • 강원종;임윤석;최재옥;장용무;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.513-515
    • /
    • 2000
  • In this paper, new Partial Discharge (PD) detection technique using Pockels-cell was proposed. For this purpose, PD was generated from needle-plane electrode in air and detected by optical measuring system using Pockets cell, based on Mach-Zehnder interferometer, consisting of He-Ne laser, single mode optical fiber, 50/50 beam splitter and photo detector. We show the characteristic of the proto-type sensor for the corona discharge.

  • PDF

식물-미생물전기화학 기반의 미활용 에너지 회수 기초 연구 (Basic Study for Harvesting Unused Energy based on Plant-Microbial Electrochemical Technology)

  • 유재철;신춘환
    • 한국환경과학회지
    • /
    • 제28권2호
    • /
    • pp.219-224
    • /
    • 2019
  • In this study, we evaluated the energy production from plant-microbial fuel cells using representative indoor plants, such as Scindapsus aureus and Clatha minor. The maximum power density of microbial fuel cell (MFC) using S. aureus ($3.36mW/m^2$) was about 2 times higher than that of the MFC using C. minor ($1.43mW/m^2$). It was confirmed that energy recovery is possible using plant-MFCs without fuel. However, further research is needed to improve the performance of plant-MFCs. Nevertheless, plant-MFCs have proved their potential as a novel energy source to overcome the limitations of the conventional renewable energy sources such as wind power and solar cells, and could be employed to a power source for the sensor in charge of the fourth industrial revolution.