• Title/Summary/Keyword: Cell Area

Search Result 3,125, Processing Time 0.035 seconds

Development of Large-area Plasma Sources for Solar Cell and Display Panel Device Manufacturing

  • Seo, Sang-Hun;Lee, Yun-Seong;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.148-148
    • /
    • 2011
  • Recently, there have been many research activities to develop the large-area plasma source, which is able to generate the high-density plasma with relatively good uniformity, for the plasma processing in the thin-film solar cell and display panel industries. The large-area CCP sources have been applied to the PECVD process as well as the etching. Especially, the PECVD processes for the depositions of various films such as a-Si:H, ${\mu}c$-Si:H, Si3N4, and SiO2 take a significant portion of processes. In order to achieve higher deposition rate (DR), good uniformity in large-area reactor, and good film quality (low defect density, high film strength, etc.), the application of VHF (>40 MHz) CCP is indispensible. However, the electromagnetic wave effect in the VHF CCP becomes an issue to resolve for the achievement of good uniformity of plasma and film. Here, we propose a new electrode as part of a method to resolve the standing wave effect in the large-area VHF CCP. The electrode is split up a series of strip-type electrodes and the strip-type electrodes and the ground ones are arranged by turns. The standing wave effect in the longitudinal direction of the strip-type electrode is reduced by using the multi-feeding method of VHF power and the uniformity in the transverse direction of the electrodes is achieved by controlling the gas flow and the gap length between the powered electrodes and the substrate. Also, we provide the process results for the growths of the a-Si:H and the ${\mu}c$-Si:H films. The high DR (2.4 nm/s for a-Si:H film and 1.5 nm/s for the ${\mu}c$-Si:H film), the controllable crystallinity (~70%) for the ${\mu}c$-Si:H film, and the relatively good uniformity (1% for a-Si:H film and 7% for the ${\mu}c$-Si:H film) can be obtained at the high frequency of 40 MHz in the large-area discharge (280 mm${\times}$540 mm). Finally, we will discuss the issues in expanding the multi-electrode to the 8G class large-area plasma processing (2.2 m${\times}$2.4 m) and in improving the process efficiency.

  • PDF

A Study on Gas-Liquid Interfacial Areas with the Stirrer Spends for A$CO_2$bsorption in Agitated Vessel (평면 교반조에서의 $CO_2$ 기체흡수에서 교반속도에 따른 기-액 계면 면적에 관한 연구)

  • 박문기;문영수
    • Journal of Environmental Science International
    • /
    • v.3 no.4
    • /
    • pp.403-408
    • /
    • 1994
  • Catalytic slurry reactors, in which a solid maintained in the rom of fine particles suspended in a liquid, are frequently used in chemical and biochemical and industries. In these processes the particle loading is normally low so that the effects of particles on the liquid-film mass transfer coefacent and the gas-liquid interface area are assumed to be negligible. But it is known from the works, amongst others, that the finely powdered activated carbon can increase the gas-liquid mass transfer significantly in surface-aerated reactors. The stirred cell (13.2cm inside diameter) contained four baffles and at the stirring speeds range of 80 ∼ 300ppm, the gas-liquid interfacial area could be considered as that of the cross section of the vessel (that is, 130.1cm2). When the stirrer speeds were increased, the effective interfacial area was slightly higher than the geometric area and was obtained experimentally from the Danckwerts plots. Key Words : gas-liquid interfacial area, Duckwert's Plot stirred dell. mass transfer coefficient.

  • PDF

Effects of age and gender on spatial orientation of human corpus callosum in healthy Koreans

  • Hwang, Seung-Jun;Park, Chan;Hong, Hea-Nam;Ryu, Ji-Yeon;Park, In-Sung;Rhyu, Im-Joo
    • Animal cells and systems
    • /
    • v.15 no.4
    • /
    • pp.274-278
    • /
    • 2011
  • The changes in the corpus callosum (CC) with age and gender remain largely subject to dispute, which might come from the different strategies for analyzing the size and shape of CC. We have investigated this issue by measuring some variables reflecting the spatial orientation of CC on magnetic resonance imaging in Koreans, which minimize individual variances in the brain. The subjects were composed of young adults in their twenties (51 male, 59 female) and elderly adults in their sixties and seventies (60 male, 71 female). The total area of CC, length and height of CC, the central angle and the four angles suggested by Oka et al. were measured. The whole area and the central angle of CC were not significantly affected by age and gender. The height and length of CC were significantly greater in elderly people. The angle connecting genu, upper notch of pons and splenium was significantly larger in the elderly group. Furthermore, all four angles were significantly different between male and female subjects. These results confirm that the spatial orientation of CC is influenced by age and gender.

High Security FeRAM-Based EPC C1G2 UHF (860 MHz-960 MHz) Passive RFID Tag Chip

  • Kang, Hee-Bok;Hong, Suk-Kyoung;Song, Yong-Wook;Sung, Man-Young;Choi, Bok-Gil;Chung, Jin-Yong;Lee, Jong-Wook
    • ETRI Journal
    • /
    • v.30 no.6
    • /
    • pp.826-832
    • /
    • 2008
  • The metal-ferroelectric-metal (MFM) capacitor in the ferroelectric random access memory (FeRAM) embedded RFID chip is used in both the memory cell region and the peripheral analog and digital circuit area for capacitance parameter control. The capacitance value of the MFM capacitor is about 30 times larger than that of conventional capacitors, such as the poly-insulator-poly (PIP) capacitor and the metal-insulator-metal (MIM) capacitor. An MFM capacitor directly stacked over the analog and memory circuit region can share the layout area with the circuit region; thus, the chip size can be reduced by about 60%. The energy transformation efficiency using the MFM scheme is higher than that of the PIP scheme in RFID chips. The radio frequency operational signal properties using circuits with MFM capacitors are almost the same as or better than with PIP, MIM, and MOS capacitors. For the default value specification requirement, the default set cell is designed with an additional dummy cell.

  • PDF

A Study on the Estimation of Steel Corrosion in Concrete Exposed under the Environment of Seawater (해양환경하에 방치한 콘크리트중의 철근의 부식 추정에 대한 연구)

  • 문한영;김성수;류재석
    • Magazine of the Korea Concrete Institute
    • /
    • v.6 no.2
    • /
    • pp.129-137
    • /
    • 1994
  • This study was performed for the purpose of obtaining the fundamental data to establish the criterion of concrete deterioration and presuming steel corrosion of concrete structures under the environment of seawater. Steel embedded concrete specimens were exposed in seawater for 1year. The soluble chloride content in concrete, corrosion potential and steel corrosion were considered. The results show that soluble chloride content in concrete was decreased with lower water-cement ratio and with mineral admixtures. Half-cell potential is reduced with steel corrosion. Corrosion area ratio is correlative with half-cell potential.

Geometrically Inhomogeneous Random Configuration Effects of Pt/C Catalysts on Catalyst Utilization in PEM Fuel Cells (연료전지 촉매층 내 촉매활성도에 대한 탄소지지 백금 촉매의 기하학적 비등방성 효과에 관한 연구)

  • Shin, Seungho;Kim, Ah-Reum;Jung, Hye-Mi;Um, Sukkee
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.10
    • /
    • pp.955-965
    • /
    • 2014
  • Transport phenomena of reactant and product are directly linked to intrinsic inhomogeneous random configurations of catalyst layer (CL) that consist of ionomer, carbon-supported catalyst (Pt/C), and pores. Hence, electrochemically active surface area (ECSA) of Pt/C is dominated by geometrical morphology of mass transport path. Undoubtedly these ECSAs are key factor of total fuel cell efficiency. In this study, non-deterministic micro-scale CLs were randomly generated by Monte Carlo method and implemented with the percolation process. To ensure valid inference about Pt/C catalyst utilization, 600 samples were chosen as the number of necessary samples with 95% confidence level. Statistic results of 600 samples generated under particular condition (20vol% Pt/C, 30vol% ionomer, 50vol% pore, and 20nm particle diameter) reveal only 18.2%~81.0% of Pt/C can construct ECSAs with mean value of 53.8%. This study indicates that the catalyst utilization in fuel cell CLs cannot be identical notwithstanding the same design condition.

New Approach to Two-wheeler Detection using Correlation Coefficient based on Histogram of Oriented Gradients

  • Lee, Yeunghak;Shim, Jaechang
    • Journal of Multimedia Information System
    • /
    • v.3 no.4
    • /
    • pp.119-128
    • /
    • 2016
  • This study aims to suggest a new algorithm for detecting two-wheelers on road that have various shapes according to the viewing angle for vision based intelligent vehicles. This article describes a new approach to two-wheelers detection algorithm riding on people based on modified Histogram of Oriented Gradients (HOG) using correlation coefficient (CC). The CC between two local area variables, in which one is the person riding a bike and other is its background, can represent correlation relation. First, we extract edge vectors using HOG which includes gradient information and differential magnitude as cell based. And then, the value, which is calculated by the CC between the area of each cell and one of two-wheelers, can be extracted as the weighting factor in process for normalizing the modified HOG cell. This paper applied the Adaboost algorithm to make a strong classification from weak classification. In this experiment, we can get the result that the detection rate of the proposed method is higher than that of the traditional method.

Eosinophilic Granuloma Presenting as an Epidural Hematoma and Cyst

  • Lee, Young-Suk;Kwon, Jeong-Taik;Park, Yong-Sook
    • Journal of Korean Neurosurgical Society
    • /
    • v.43 no.6
    • /
    • pp.304-306
    • /
    • 2008
  • Langerhans' cell histiocytosis (LCH) is a rare immunologic disorder characterized by histiocyte proliferation in multiple organ systems. Eosinophilic granuloma, a benign bone lesion, represents a focal form of LCH. We experienced a case of Langerhans' cell histiocytosis in a patient who presented with intracranial epidural hematoma and cyst on the midline of the frontal skull. A 10-year-old boy presented with a rapidly growing large scalp mass on the midline frontal area after mild head trauma. The scalp mass was painless and immobile. Plain skull x-ray showed a punched-out bone lesion. Computed tomography and magnetic resonance imaging showed a non-enhancing osteolytic lesion presenting with an epidural hematoma and cyst on the midline of the frontal skull. The lesion of the skull was completely resected and the patient's recovery was uneventful. The acute presentation of a solitary eosinophilic granuloma of skull with an epidural hematoma has been described in only five cases in the literature and we report the first case of LCH presenting as an intracranial epidural hematoma on frontal area.

Long-term Environmental Changes: Interpretations from a Marine Benthic Ecologist's Perspective (II) -Eutrophication and Substratum Properties

  • Yoo Jae-Won;Hong Jae-Sang;Lee Jae June
    • Fisheries and Aquatic Sciences
    • /
    • v.2 no.2
    • /
    • pp.210-217
    • /
    • 1999
  • Chemical oxygen demand (COD), phytoplankton cell number and chlorophyll-a concentration (Chl-a), sediment mean grain size and ignition loss were studied to determine their temporal trends in the study area. Historical data of COD, cell number and Chl-a were gathered from the late 1960s or early 1980s to 1997, and trends in temporal domain were obtained from a simple regression. Sediments for grain size and ignition loss (as organic contents in sediments) were sampled from the Chokchon macrotidal flat bimonthly from September 1990 to November 1996, and were analyzed using the decomposition method of time series analysis. In general, the first three data showed increasing trends based on regression analysis. The trends of sediment grain size fluctuated in a neutral pathway while those of ignition loss yielded no increasing pattern. In contrast with the suggestions from Ahn and Choi (1998) who reported a coarsening variation in sediment grain size to be a cause of the directional and remarkable changes of macrofaunal communities in this area, we could not find such a corresponding variation pattern from our samples. In diagnosing eutrophication, a paradoxical phenomenon was encountered between the trends in water column (COD, cell number and Chl-a) and sediment (ignition loss) data. In this paper, we inferred the possible processes that produce the discrepancy. Some explanations and biological responses to eutrophication were predicted and discussed.

  • PDF

The Intrinsic Safety Evaluation of Solar Photovoltaic Cell (태양전지셀의 본질안전 방폭성능 평가)

  • Lee, Chun-Ha;Jee, Seung-Wook;Kim, Si-Kuk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.7
    • /
    • pp.49-54
    • /
    • 2011
  • Now the world will regulate the CO2 emission due to environmental issues. For an alternative plan photovoltaic system is watched. So, photovoltaic system is trend of big city and it is mandatory for renovation of construction. Oil & gas filling station existed in city is suitable to found the photovoltaic system. But the general photovoltaic system in oil & gas filling station is difficult to found because it is classified into hazardous area. This paper evaluates intrinsic safety evaluation of solar cell for making basic data to found for the photovoltaic system on hazardous area. The intrinsic safety characteristic is evaluated by short-circuit ignition test using IEC type spark ignition test apparatus and temperature rising test. The result of short-circuit ignition test, propane-air mixture gas is exploded on condition that 4 solar cells(9[V], 90[mA]) are connected serially under insolation 800[W/$m^2$]. So, if a larger solar module will be used at oil & gas filling station than we were tested, it needs explosion proof. As the result of rising temperature test, the temperature rising due to short circuit is not so much, but when the temperature rises due to radiant heat, it demands careful consideration for environmental influence.