Data Analysis for Structural Design of Pleurotus Eryngii Cultivation Facilities (큰느타리버섯 재배사의 구조설계용 자료 분석)

  • Suh, Won-Myung;Yoon, Yong-Cheol
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.47 no.3
    • /
    • pp.29-37
    • /
    • 2005
  • This study was carried out to file up structural design data for optimizing Pleurotus eryngii growing houses. Design data are including current farm status of Pleurotus eryngii growing houses in the aspect of structural configuration as well as environmental conditions to be controlled and maintained inside. A structural analysis was performed for the on-farm structures as well as some structures modified and suggested through field survey and analysis. The results are summarized as follows. According to the results of status analysis, Pleurotus eryngii growing houses were categorized as arch-roofed simple type and sandwich panel type. Though the size of Pleurotus eryngii cultivation facilities were considerably diverse, the basic dimensions of Pleurotus eryngii cultivation facilities showed relatively similar pattern: more or less of 20m of length, $6.6\~7.0m$ of width, $4.6\~5.0m$ of peak height, $1.2\~1.6m$ of bed width, and 4 layers of bed. In the aspect of spatial use of cultivation facilities, suggested models were shown to be mostly reasonable in the aspect of heating and cooling, micro-meteorological stability, land use efficiency per unit floor area, etc.. Especially, the standard models suggested so far were thought to be not efficient in its surface area and spatial volume per unit floor area as well as its uneffective structural design in the area around ceiling. In the results of structural analysis for the models suggested through this study by using those section frames to be found on farms, the panel type structures of both single span and double span were estimated to be over designed, whereas arch-roofed pipe houses were mostly found to be under-designed.

A Numerical Study on Flow Field near the Roller Conveyor for Flat Panel Display (평면 디스플레이 기판 운송용 롤러 컨베이어 주위의 유동장에 관한 수치해석 연구)

  • Jeon, Hyun-Joo;Kim, Hyoung-Jin;Im, Ik-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.1
    • /
    • pp.6-11
    • /
    • 2009
  • Flow field in a roller conveyor system, induced from the movement of a cassette in which glasses for flat panel display are loaded, is numerically studied in this paper. Contamination on the glass surface by dust particles produced from mechanical friction between roller and cassette is predicted from the analysis results of flow fields. Results show that a large swirl flow is formed under the moving cassette with constant speed. This swirl flow is confined only under the cassette because two main streams from the backward and the fan filter unit on the top ceiling are sufficiently strong. Therefore, it can be said that possibility of the contamination by the particles originated from the friction is relatively low. It is also revealed that flow direction between glass plates is changed according to the speed of the cassette movement due to the shear force of glass plates.

Evaluation of Sound Insulation Performance of a Unit Cabin Mock-up (유니트 캐빈 목업(mock-up)의 차음성능평가)

  • Kim, Hyun-Sil;Kim, Sang-Ryul;Kim, Bong-Ki;Kim, Jae-Seung;Lee, Sung-Hyun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.48 no.1
    • /
    • pp.49-55
    • /
    • 2011
  • Sound insulation performance of a unit cabin mock-up is studied, where two identical rooms simulating cruise ship cabin are installed. STL (Sound Transmission Loss) measurement in the mock-up shows that STL of the partition between rooms is degraded by imperfect door ceiling and gap between wall and floor. It is also observed that gap around lighting and electrical outlet slightly affect the STL in high frequency ranges, since lighting and electrical outlet are supported by mineral wool in the back side due to fire-resistance requirement. Even after all possible gaps are sealed, STL of the partition is found to be lower than that measured in the laboratory by 9 dB. Measurement of SBN (Structure-Borne Noise) reveals that flanking transmission of SBN along the steel deck floor can severely deteriorate STL of the partition. Statistical energy analysis (SEA) of the mock-up confirms importance of the floor SBN control, in which increasing damping is essential to ensure high STL.

Measurement of Thermal Characteristics of Electric Unit for Sancheon High-Speed Railcar (고속열차 산천 전장품 발열특성 측정)

  • Park, Won-Hee;Yun, Su-hwan;Park, Choonsoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.3672-3679
    • /
    • 2015
  • The heat generated by electrical components during train operation was estimated by measuring the wall temperature in a locomotive, as well as the temperature and speed of the air entering from the outside and then returning to the outside. The temperatures of the electrical components and wall surface in a high-speed train were measured using an infrared camera. The heat generated by the electrical components was exhausted to the outside through a duct installed on the ceiling of the high-speed train. Thus, the temperature and speed of this exhaust air were measured, as well as those of the air entering the locomotive from the outside. The temperatures at the surfaces of the electrical components and walls in the locomotive were also measured using an attachment-type temperature sensor. In addition, the measurement results were applied to analyze how the heat characteristics of the electrical components were affected by the train operation.

Cyclic Loading Test and an Analytical Evaluation of the Modular System with Bracket-typed Fully Restrained Moment Connections (브래킷형 완전강접합 모듈러 시스템의 반복가력실험과 해석적 평가)

  • Park, Jae-Seong;Kang, Chang-Hoon;Shon, Su-Deok;Lee, Seung-Jae
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.3
    • /
    • pp.19-28
    • /
    • 2018
  • Key factors that ensure competitiveness of modular unit include consistent high quality and connection condition that ensures high structural performance while minimizing the overall scale of the on-site process. However, it is difficult to evaluate the structural performance of the connection of modular unit, and its structural analysis and design method can be different depending on the connection to its development, which affects the seismic performance of its final design. In particular, securing the seismic performance is the key to designing modular systems of mid-to-high-rise structure. In this paper, therefore, the seismic performance of the modular system with bracket-typed fully restrained moment connections according to stiffness and the shapes of various connection members was evaluated through experimental and analytical methods. To verify the seismic performance, a cyclic loading test of the connection joint of the proposed modular system was conducted. As a result of this study, theoretical values and experimental results were compared with the initial stiffness, hysteresis behavior and maximum bending moment of the modular system. Also, the connection joint was modeled, using the commercial program ANSYS, which was then followed by finite element analysis of the system. According to the results of the experiment, the maximum resisting force of the proposed connection exceeded the theoretical parameters, which indicated that a rigid joint structural performance could be secured. These results almost satisfied the criteria for connection bending strength of special moment frame listed on KBC2016.

Study on Demand Estimation of Agricultural Machinery by Using Logistic Curve Function and Markov Chain Model (로지스틱함수법 및 Markov 전이모형법을 이용한 농업기계의 수요예측에 관한 연구)

  • Yun Y. D.
    • Journal of Biosystems Engineering
    • /
    • v.29 no.5 s.106
    • /
    • pp.441-450
    • /
    • 2004
  • This study was performed to estimate mid and long term demands of a tractor, a rice transplanter, a combine and a grain dryer by using logistic curve function and Markov chain model. Field survey was done to decide some parameters far logistic curve function and Markov chain model. Ceiling values of tractor and combine fer logistic curve function analysis were 209,280 and 85,607 respectively. Based on logistic curve function analysis, total number of tractors increased slightly during the period analysed. New demand for combine was found to be zero. Markov chain analysis was carried out with 2 scenarios. With the scenario 1(rice price $10\%$ down and current supporting policy by government), new demand for tractor was decreased gradually up to 700 unit in the year 2012. For combine, new demand was zero. Regardless of scenarios, the replacement demand was increased slightly after 2003. After then, the replacement demand is decreased after the certain time. Two analysis of logistic owe function and Markov chain model showed the similar trend in increase and decrease for total number of tractors and combines. However, the difference in numbers of tractors and combines between the results from 2 analysis got bigger as the time passed.

Sensibility Evaluation Model Research as to The Three-dimensional Surface Light Source set In The Interior (실내 3D 입체 면광원 조명연출에 관한 감성평가 모형 연구)

  • Lee, Jin-Sook;Park, Ji-Young;Jeong, Chan-Ung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.6
    • /
    • pp.14-26
    • /
    • 2015
  • This study has been conducted so as to analyse user's sensibility on lighting method, correlated color temperature and illumination by composing surface light source, which was projected onto a unit side of interior wall, ceiling and floor. 1) As an analyzed results of the sensibility images, it showed that the "snug & tender" value had got higher when the correlated color temperature got lower. And the "energetic, cheerful" value had got higher when the level of illuminance got lower. Furthermore, the "unusual, unique" showed higher value on the illuminated floor circumstance. Finally, the higher correlated color temperature had been, "energetic, cheerful" value also got higher. 2) As a result of multi-regression analysis, it was found that 3000K and 100lx had the biggest influence on 'snug' image while 5,500K, 500lx had the biggest influence on 'energetic' image. In addition, it was found that the illuminated floor had a big influence on 'unusual' image while 500lx had the biggest influence on 'refined' image.

Investigations on Lighting Environment of Living Room and Lighting Use According to the Behavior in Large Apartment Houses (대형 공동주택 거실 조명환경과 행위별 조명사용에 관한 조사연구)

  • Kim, Hyun-Ji;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.3
    • /
    • pp.1-8
    • /
    • 2012
  • This study investigated current status of lighting environment, residents' awareness of lighting and lighting use according to behavior in the living room of apartment to determine current lighting trends and their related problems. The living rooms of newly-built apartment units(133~165[$m^2$] and larger than 166[$m^2$] within the past five years) were examined. The results are summarized as follows. 1. Resident satisfaction with current living room lighting was the highest in 'illumination' and the lowest was 'energy savings' regardless of the size of living room. 2. This kind of ceiling lighting layout, 133~165[$m^2$] unit used central lighting and larger than 166[$m^2$] units used central lighting and cove lighting. Regarding light sources, 133~165[$m^2$] linear FL, halogen, larger than 166[$m^2$] bulb-type FL are widely used. LED are now being found in the living room corridor and kitchen walls of newly-built apartment houses. 3. Watching TV and reading books were commonly behaved in the living room. Conversations between family, having desserts, resting, housekeeping, and entertaining were usually done weekdays, while having desserts and conversations between family were done weekends. Use of lighting as main behaviors is properly and differently required due to the distinct uses of lighting as residents' behaviors or their life style.

A Study on the Adaptable Long Life Multi-dwelling Housing Design in Korea (융통성을 고려한 장수명 공동주택 디자인에 관한 연구)

  • Kim, Jin-Hee
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.6 s.59
    • /
    • pp.172-177
    • /
    • 2006
  • Most of the Korean multi-dwelling houses have less than 20 years of lifespan. Because the environmental issues such as energy consumption, limited resources, and demolition waste problems became been more and more critical, we now need to focus on long lasting and adaptable buildings. Korean wall bearing apartment buildings are constructed with site cast concrete for core, exterior, and interior together with pipes varied, so when the buildings are old and life style of the users changes, it is difficult to maintain and renovate these buildings. In this study, to resolve the problems described above, two types of Korean long life multi-dwelling housing models which represent improved durability and adaptability responding user's needs and life style changes were proposed with various methods as follows: Either column and beam structure or flat slab structure was used to utilize space better. To make maintenance easier and renovation economical for both public space and each unit, plumbing pipes, ducts, and conduits were clustered at the cores and public corridors with access doors and light weight partitions with steel studs and raised floors or above-ceiling spaces were used in lieu of site cast concrete walls and floor slabs with varied pipes.

UV Immune System of Personalized Space (개별공간의 자외선 살균 시스템)

  • Jeong, Ky-Bum;Choi, Sang-Gon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.1
    • /
    • pp.63-70
    • /
    • 2009
  • The air sterilization systems are investigated experimentally in this paper. The goal is to reduce bacteria, mold and viruses in office air by using a UV sterilizer installed inside a partition panel and wall-mounted unit. These systems allow occupants to turn the system on/off and to control the incoming air speed and direction. The partition air sterilization system conditions and sterilizes the air, and then delivers the clean air into the personal task area through the partition panels, which are connected to the pressurized under-floor plenum. Room air exits through the return grills mounted on the ceiling. The wall-mounted air sterilization system sterilizes the air, and then delivers the clean air to the personal task area from the wall. In this study a full-size experimental environment is established to investigate the immunization performance of these air sterilization systems. A typical office space scale is used in this study in order to find an optimal system to achieve a sterilized healthy micro-environment. Multiple system parameters, including volume flow rate and velocity of supplied air, were regulated during the experiments. The more air contact these air sterilization systems had, the better disinfection performance. Over 90% of eradication ratios were obtained by these two air sterilization systems. The results indicate that these systems can efficiently disinfect office air contamination.