• Title/Summary/Keyword: Ceiling unit

Search Result 58, Processing Time 0.03 seconds

A Study on the comparison of Infill Technology between Korea long life Apartment Mock up House and Japan KSI experimental House (국내 장수명 공동주택 Mock-up House와 일본 KSI 실험주택 인필 요소기술 비교 연구)

  • Choi, Young Ho;Kim, Shin;Kim, Sung Wan
    • KIEAE Journal
    • /
    • v.8 no.4
    • /
    • pp.63-69
    • /
    • 2008
  • The thesis is a comparative analysis of Infill Technologies between Korea's long-life Mock-up House, a study driven by 'Durability and Flexibility of Long-life Housing Technology Development' of R&D, and Japan's KSI experimental house, the major example of Japan's long-llfe housing. In terms of the domestic Mock-up House, a system of building the floor first was applied. The floor material of each housing unit required a development of dry heating component that is partially substitutable in order to avoid conflict with the finishing. Also, a development of a floor system that can counteract against the construction inaccuracy was required. In the Case of an outer wall, need to make the wall with the chassis. In the case of ceiling, need to develop the double ceiling system which is good for sound insulation. Also, in comparison to KSI experimental house in Japan, it would require to develop a wiring system of the ceiling which can react to the movement of the wall. Especially, to assure the flexible nature of an internal wall, it would desperately require the research and development of the products related to components and flexible system of mechanical/electrical/communication parts as well as supporting institutionalized system for this development. Furthermore, for KSI experimental house in Japan, it would be necessary to formulate a construction manual as well as a systematic and practical planning guide to invent a new interface rule which will secure simplicity of assembling, dismantling, installation and replacement of architectural components for which research development is quite insignificant at the moment. This effort will have to continue to give a solid direction for better application of such reference manual during construction and development of long life span apartment by public sector as well as private corporations.

Energy Saving Potentials of Dedicated Outdoor Air System in a High-rise Apartment Building (외기전담 시스템 기반 초고층 공동주택 중앙 환기시스템의 에너지 절감효과 분석)

  • Kim, Min-Hwi;Kim, Jin-Hyo;Kwon, Oh-Hyun;Jeong, Jae-Weon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.291-296
    • /
    • 2009
  • This paper investigates the energy saving potentials of a dedicated outdoor air system (DOAS) applied to a highrise apartment building. As for a typical $132-m^2$ apartment unit, two different HVAC systems; centralized DOAS-Ceiling Radiant Cooling Panel and decentralized Energy Recovery Ventilator-Packaged Air Conditioner were installed. Transient behavior and control characteristics of each system were modeled numerically using a commercial equation solver program, and annual cooling coil load and heating load reduction potentials were compared. The research shows that DOAS-Ceiling Radiant Cooling Panel system can reduce the cooling coil load over 21% annually compared with the current Energy Recovery Ventilator-Packaged Air Conditioner pair. In addition, over 40% of annual ventilation heating load can be reduced by use of DOAS.

  • PDF

A Study on the Typology and the Characteristics of the Architectural Zenithal Opening -Focused on the Inflow Methods of the Zenithal Light- (천창의 유형및 특성에 관한 연구 -빛의 유입 방법을 중심으로-)

  • Ryu, Joohi;Kim, Young-Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.8
    • /
    • pp.5619-5626
    • /
    • 2015
  • The zenithal light is the one that is entered down into the interior space or the spaces such as the inner court, through windows high located in the wall or openings of the roof. The aim of this study is to analyze the types of mechanism for the zenithal light by studying some examples related to the zenithal opening, and to investigate those characteristics. One of the most important features is a structural unit of the skylight entering the room. In this study, according to the structural unit, the direct light type, the duct-type and the shade type was distinguished, and each type can be divided into several modified types. Precisely, the direct light type is divided into an unexposed type and an exposed type of the source of light. The duct type is also divided into an intensive duct type and a distributed duct type. The shade type is classified into a ceiling surface shade, a reflections objet shade, a double ceiling shade and a wall shade.

Actual Condition of Remodeling in Apartment Unit - Grasp of Remodeling elements by Specialists' In-depth Interviews - (아파트 단위주거의 리모델링 실태 - 실무자 심층면접에 의한 리모델링 요소 현황 파악 -)

  • Choi, Yoon-Jung;Shim, Hyun-Suk;Jeong, Youn-Hong
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2007.05a
    • /
    • pp.81-84
    • /
    • 2007
  • The purpose of this study was to grasp actual condition of remodeling elements by specialists' in-depth interviews. The interview has been conducted to interior designer who have a wide experience of apartment remodeling. In-depth interview is a kind of qualitative method in which attention to reply of responses with open-access between interviewer and respondents. According to the results, remodeling elements were generally the renovation of balcony into the livingroom or children room, removal a doorsill, installation of storage furniture, change of lighting fixtures in the all rooms and change equipments of bathroom. Finishing materials were usual used normal wallpaper and normal or low emitting adhesive on ceiling and wall, tempered-flooring on floor, and ceramic tiles on bottom and wall of bath and entrance.

  • PDF

A Study on the noise & vibration properities of Fan Filter Unit and evaluation of effect to Clean Room (Fan Filter Unit 소음ㆍ진동 특성과 청정실에 미치는 영향성 평가에 관한 연구)

  • 백재호;손성완
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.778-784
    • /
    • 2002
  • FFU are used increasingly by the microeleceronics industry to provide clean recirculating air for the fabrication of integrated circuits and laminar flow air. There may be several hundred ffu in a large cleanroom, covering 100% of the ceiling area. Hence, there is of often knowledge in the inside and outside of the country the flu give rise to noise & vibration trouble to microelectronics industry. Noise & Vibration control for satisfication about noise & vibration criteria in TFT-LCD factory cleanroom be in need of exact noise & vibration data of accurence from utility & equipment that can be exert a bad influence upon cleanroom. In this pater, hence we found out noise and vibration properities of ffu by using experimental method. And, we performed noise & vibration analysis about noise it vibration level in cleanroom using semiempirical method for quantative approach about noise & vibration level in cleanroom.

  • PDF

An Experimental Study on Thermal and Environmental Characteristics of Various Heating Systems in the Residential House (주거용 건물의 난방 방식별 열적성능 및 실내환경 특성 평가를 위한 실험적 연구)

  • Lee, Choong-Kook;Cho, Sung-Hwan
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.121-128
    • /
    • 2005
  • This is about experimental comparison study between convective heating and radiation heating system to use the design criteria for residential house. Experiment was done in EC(environment chamber) under simultaneous outdoor condition for 4 kinds of heating system such as CRHP(Ceiling Radiant Heating Panel), BEHC( Bottom Electric Heating Coil Mat), EFCU( Electric Fan Coil Unit) and CEHU( Convective Electric Heating Unit). Result show that CRHP ,which is radiation heating system, can consume more 23% energy than convective heating system when it is operated by dry bulb temperature but can save 1 ${\sim}$ 10% when operated by glove temperature and 27% when operated by MRT.

  • PDF

Object Localization in Sensor Network using the Infrared Light based Sector and Inertial Measurement Unit Information (적외선기반 구역정보와 관성항법장치정보를 이용한 센서 네트워크 환경에서의 물체위치 추정)

  • Lee, Min-Young;Lee, Soo-Yong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.12
    • /
    • pp.1167-1175
    • /
    • 2010
  • This paper presents the use of the inertial measurement unit information and the infrared sector information for getting the position of an object. Travel distance is usually calculated from the double integration of the accelerometer output with respect to time; however, the accumulated errors due to the drift are inevitable. The orientation change of the accelerometer also causes error because the gravity is added to the measured acceleration. Unless three axis orientations are completely identified, the accelerometer alone does not provide correct acceleration for estimating the travel distance. We propose a way of minimizing the error due to the change of the orientation. In order to reduce the accumulated error, the infrared sector information is fused with the inertial measurement unit information. Infrared sector information has highly deterministic characteristics, different from RFID. By putting several infrared emitters on the ceiling, the floor is divided into many different sectors and each sector is set to have a unique identification. Infrared light based sector information tells the sector the object is in, but the size of the uncertainty is too large if only the sector information is used. This paper presents an algorithm which combines both the inertial measurement unit information and the sector information so that the size of the uncertainty becomes smaller. It also introduces a framework which can be used with other types of the artificial landmarks. The characteristics of the developed infrared light based sector and the proposed algorithm are verified from the experiments.

A Case Study of Space Utilization on Compact Houses in Japan to build Compact-but-effective Houses in Korea (강소주택 실효성 논의를 위한 일본 소형주택 공간 활용 사례 분석)

  • Seo, Min-Woo;Han, Young-Ho
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.1
    • /
    • pp.148-158
    • /
    • 2012
  • The objective of this study is to find a possible application of small space utilization of GangSo Housing, so called compact-but-effective housing, through analyzing that of Japanese small housing. We analyze openness of view and flexibility of spaces divided by the physical and architectural aspects as first component and the psychological and interior space aspects as second component. The results showed that Japanese small houses have various unit plan compared to uniformity of Korean houses. Openness of view in Japanese small housing is accomplished by letting in light from the outside using position and shape of the window, looking more spacious using courtyard, void spaces, or sliding door hanging from the ceiling, and creating deception of view using floor-wall plan and appropriate materials. Flexibility of spaces is achieved by combination of first and second components, multipurpose of space and furniture, and variety of storage methods. It is necessary to improve spatial efficiency with consideration of volume-metric planing rather than flat-plane and develop various unit plans to meet residents' needs and demands on compact-but-effective houses.

  • PDF

The Kitchen furniture design Based on Stored items of Cooking Area in 40-pyung type apartment Houses (40평형 아파트 식생활용품 수납실태에 따른 부엌가구디자인)

  • Kim, Gi-In;Kim, Sun-Joong;Kwon, Myung-Hee
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.04a
    • /
    • pp.304-309
    • /
    • 2009
  • The purpose of this study is to develop kitchen furniture design for 40-pyung apartment Houses based on stored item of Cooking, Eating and Utility Area. The research data is gotten at a field study of stored items of Cooking, Eating and Utility Area and depth interview. The results of this study were as follows; 1)The kitchen furniture the preparation unit and the sink, the kitchen table, the heating unit and the service table, arranged at the tall storage. 2)The total bulk considered and holding volume ($2.7m^3$) with ground clearance (40%) planned with about $4.21m^3$. 3)Assumed at height and 162cm did a lower part height with 860mm and the upper depth 340mm, did with 700mm where raises. the storage the ceiling which raises will select and considered and with 2200mm did. 4)Arrangement of the kitchen the kitchen form which is an open type (L/DK or L.D.K) arranged many in forms of letter.

  • PDF

Flow Analysis around the Roller Conveyor in a Clean Room (클린룸 내 롤러 컨베이어 운송장치 주위의 유동해석)

  • Jeon, Hyun-Joo;Park, Chan-Woo;Im, Ik-Tae
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1507-1512
    • /
    • 2009
  • Flow field in a roller conveyor system, induced from the movement of a cassette in which glasses for flat panel display are loaded, is numerically studied in this paper. Contamination on the glass surface by dust particles produced from mechanical friction between roller and cassette is predicted from the analysis results of flow fields. Results show that a large swirl flow is formed under the moving cassette with constant speed. This swirl flow is confined only under the cassette because two main streams from the backward and the fan filter unit on the top ceiling are sufficiently strong. Therefore, it can be said that possibility of the contamination by the particles originated from the friction is relatively low. It is also revealed that flow direction between glass plates is changed according to the speed of the cassette movement due to the shear force of glass plates.

  • PDF