• Title/Summary/Keyword: Ceiling System

Search Result 353, Processing Time 0.029 seconds

Evaluation of Thermal Comfort in Ceiling Cooling System (천장복사냉방의 온열쾌적성 평가에 관한 연구)

  • Lee, Ju-Youn
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.4
    • /
    • pp.287-293
    • /
    • 2008
  • The purpose of this study was to clarify the effects of air and ceiling temperatures on a type of ceiling cooling system that involves cool water circulation. The experiment is conducted in summer. The subjects (11 young females) are exposed to the following conditions: combinations of air temperatures $(27^{\circ}C,\;29^{\circ}C,\;31^{\circ}C)$ and ceiling temperature of $(22.7^{\circ}C,\;23.7^{\circ}C,\;24.7^{\circ}C)$ in still air and RH 50%. The following results were obtained; the thermal sensation vote is neutral at a mean skin temperature of $34.5^{\circ}C$. The ceiling temperature affected different parts of the body. For example, the forehead, scapula and abdomen produced different skin temperatures. Thermal comfort vote was rated as comfortable at high temperature environment. The satisfaction from the ceiling temperature was valued comfortable zone in this experiment. Mean skin temperature showing higher thermal neutrality temperature than existing studies for floor and wall radiation cooling results.

Localization of Mobile Robots by Full Detection of Ceiling Outlines (천장 외곽선 전체 검출에 의한 모바일 로봇의 위치 인식)

  • Kim, Young-Gyu;Park, Tae-Hyoung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.7
    • /
    • pp.1283-1289
    • /
    • 2016
  • In this paper, we propose a new localization system using ceiling outlines. We acquire the entire ceiling image by using fisheye lens camera, and extract the lines by binarization and segmentation. The optical flow algorithm is then applied to identify the ceiling region from the segmented regions. Finally we obtain the position and orientation of the robot by the center position and momentum of ceiling region. Since we use the fully detected outlines, the accuracy and reliability of the localization system is improved. The experimental result are finally presented to show the effectiveness of the proposed method.

Comparison of the PMV and ADPI according to Adapted Height of Ceiling-type System Air-conditioner in Large space (천정형 정풍량 시스템에어컨의 적용높이에 따른 실내온열환경 특성)

  • Sung, Sang-Chul;Kim, Hyouk-Soon;Chin, Sim-Won;Oh, Myung-Do
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.590-595
    • /
    • 2009
  • PMV and ADPI were numerically investigated in a large space of various ceiling height with air-conditioning systems of two type. The numerical results showed that it is small that the growth of cooling load according to ceiling height rise in a large space without windows. In case of system air-conditioner of duct type embedded in the ceiling, the air mixing effect in indoor is superior to a case installed 4way cassette type in it. For controling thermal comfort at indoor, a system air-conditioner of duct type embedded in the ceiling is little influenced according to ceiling height rise in a large space considered.

  • PDF

Status and Characteristics of Applying a Copayment Ceiling for the Elderly (65세 이상 본인부담 상한 적용 노인의 의료서비스 이용 현황과 특성)

  • Park, Cho-Yeal;Park, Young-Hee
    • The Korean Journal of Health Service Management
    • /
    • v.14 no.1
    • /
    • pp.147-159
    • /
    • 2020
  • Objectives: This study is the human factors and disease factors of the copayment system for the elderly (>65 years old) and to identify does the current status and characteristics of the applied elderly and conducted to provide basic data. Methods: Sample cohort data from the National Health Insurance Corporation database, from the years 2012-2015, were analyzed of 21,772 elderly people over the copayment ceiling. Results: The ratio of those who exceeded the copayment ceiling system rose sharply from progressive rates of 3.39% in 2012, 3.69% in 2013 and 5.03% in 2014, to rates of 37.13% from 2013. Factors identified that affect the instances of being over the copayment ceiling were: age, income group, region, severity, disability, sickness distribution, inpatient days, and outpatient days. Conclusions: The reorganization of the copayment ceiling system in 2014 favored low-income families of the elderly, but in 2015, the proportion of elderly was low (only 5.78%). The government's policies needs to change to allow for the amount of the deductible upper limit for low- and middle- income groups to be further subdivided in order for the elderly to receive more deductibles.

A Study of the Development of a Modular, Lightweight Steel Ceiling System (유닛형 경량철골 천정시스템 개발에 관한 연구)

  • Kim, Hyeyeon;Bae, Sanghwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.5
    • /
    • pp.269-277
    • /
    • 2017
  • This study consists of an analysis of pre-existing ceiling construction systems as well as the development of a replacement unitary, lightweight steel ceiling system and related legal standards. Based on the material conditions and progression of the study, appropriate components were chosen and details were modified by mock-up test. A final study model was evaluated for performance and adaptability based on four parameters (indoor environment, constructability, budget economy, and aesthetics) and compared to the pre-existing ceiling system. As a result of the initial study, a lightweight steel design was created consisting of a reinforced structure with modular bars and entry holes for components. This system was hung directly on the suspension structure. The new design increased lighting and acoustic performance adapted to an indoor environment. Moreover, the speed of construction was increased by approximately 30%, the cost was decreased by approximately 20%, and ceiling aesthetics were improved.

Joint installation of ceiling facilities in the subway system (지하철 천장시설물 공동설치 방안)

  • Lee, Pil-Sin
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1953-1959
    • /
    • 2011
  • Subway stations have a characteristic that the facilities in the ceiling should be checked, replaced and expanded frequently. The new installation of supports (steel anchors) for new facilities and workers moving-around in the ceiling result in the damage in the ceiling finish material and concrete structure which also result in construction cost increase. In addition, the noise, vibration and dust generated during the work harm the station environment. There are civil complaints on these which give difficulty to ceiling works. Accordingly, this study suggests a ceiling frame construction method that considers the convenience, economy and efficiency of ceiling work by improving the support installation method for facilities in ceiling.

  • PDF

Global Localization Based on Ceiling Image Map (천장 영상지도 기반의 전역 위치추정)

  • Heo, Hwan;Song, Jae-Bok
    • The Journal of Korea Robotics Society
    • /
    • v.9 no.3
    • /
    • pp.170-177
    • /
    • 2014
  • This paper proposes a novel upward-looking camera-based global localization using a ceiling image map. The ceiling images obtained through the SLAM process are integrated into the ceiling image map using a particle filter. Global localization is performed by matching the ceiling image map with the current ceiling image using SURF keypoint correspondences. The robot pose is then estimated by the coordinate transformation from the ceiling image map to the global coordinate system. A series of experiments show that the proposed method is robust in real environments.

An Experimental Study on the Improvement Floor Impact Sound Insulation by Ceiling Structure in Apartment Houses (천장구조를 이용한 공동주택 바닥충격음 차단성능 개선에 관한 실험적 연구)

  • Baek, Eun-Sun
    • KIEAE Journal
    • /
    • v.7 no.1
    • /
    • pp.95-100
    • /
    • 2007
  • In apartment houses, said to be similar to a typical housing form, every household share the walls and floors. Many problems inevitably accompany such as an arrangement, as noise and vibration are shared among households. When investigating the percentage of apartment resident's dissatisfaction with housing environments, discontent due to noise ranks the highest. Among many different kinds of noises, noise such as floor crashing sounds show the highest indication rate in the residents' comparison of discontent. Therefore, it is the practice of insulating against noises such as floor crashing sounds that improves the apartment house environments. The factors influencing the floor impact sound insulation include floor finishing materials, shock absorbing floors (slabs included), and ceiling structures. The ceilings of the apartment houses, currently built in Korea, are set up with lower parts of slabs and paper finishing, or with double floors for protecting against floor impact sounds in order to improve the sound insulating performance. The most common the method of ceiling structure construction consists of 'wood boarded frames +Gypsum boards + ceiling papers', which is called the wood boarded frame method. This study aimed to measures and evaluates floor impact sound insulation by which the ceiling space are widened according to suppression system is added in apartment house ceiling structure.

The Experiment on The Efficiency of Heating System for Improving Farm Houses (농촌주택 개량을 위한 난방 효율 시험)

  • 이회만;최예환
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.16 no.2
    • /
    • pp.3395-3409
    • /
    • 1974
  • The purpose of this study is to test and compare the efficiency of heating-system for materials and construction of the wall, ceiling and window in soil brick house, cement house and boulder house respectively, in order to construct ideal farm houses in rural area. The results obtained were as follows: 1. In heat conservation due to construction of walls the thermal efficiency of cement brick house was equivalent to 66.3% of that of soil brick house, and boulder house 60.3% 2. In the case of ceiling, the thermal efficiency of paper ceiling was amounted to 84.2% of that of the composite ceiling (thickness 6mm veneer+thickness. l0m chaffs), and the common ceiling putting on soil above the ceiling, 76% of the composite while the efficiency of the ceiling putting on chaffs above them was 15.8% higher than that of the paper. 3. In the case of improving the window, the double type was 12% higher than. the efficiency of single type. 4. The warming velocity of conventional house was slower but the velocity of radiation was quicker than that of experimental one. It was thought to be due to unscietific constructions of the room bottom, fire inlet and chimney, 5. The temperature gradient line was not dependad upon the amount of throwing into fuel in the rural farm house. 6. It was concluded that the final thermal efficiency of the conventional farm house was 10.6% lower than that of experimental farm house.

  • PDF

Localization of a Mobile Robot Using Multiple Ceiling Lights (여러 개의 조명등을 이용한 이동 로봇의 위치 추정)

  • Han, Yeon-Ju;Park, Tae-Hyoung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.4
    • /
    • pp.379-384
    • /
    • 2013
  • We propose a new global positioning method for the indoor mobile robots. The multiple indoor lights fixed in ceiling are used as the landmarks of positioning system. The ceiling images are acquired by the fisheye lens camera mounted on the moving robot. The position and orientation of the lights are extracted by binarization and labeling techniques. Also the boundary lines between ceiling and walls are extracted to identify the order of each light. The robot position is then calculated from the extracted position and known position of the lights. The proposed system can increase the accuracy and reduce the computation time comparing with the other positioning methods using natural landmark. Experimental results are presented to show the performance of the method.